Electric Utility Network Foundation 5.1

Contents

Introduction
The data dictionary includes a description of the elements in the Electric Utility Network Foundation 5.1. It will help you understand what elements are used to create the utility network and provide a description of what they are.

Data Design Annotations

DataDesignNotes

Class Details
DatasetType ShapeType Alias Has Attachment
FEATURE_CLASS ANNOTATION Data Design Notes False
Fields
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
featureid FeatureID LONG True
zorder ZOrder LONG True
annotationclassid AnnotationClassID LONG True
element Element BLOB True
symbolid SymbolID LONG True
status Status SHORT AnnotationStatus True
textstring TextString TEXT (2000) True
fontname FontName TEXT (255) True
fontstyle FontStyle TEXT (255) True
fontsize FontSize DOUBLE True
underline Underline SHORT BooleanSymbolValue True
verticalalignment VerticalAlignment SHORT VerticalAlignment True
horizontalalignment HorizontalAlignment SHORT HorizontalAlignment True
xoffset XOffset DOUBLE True
yoffset YOffset DOUBLE True
angle Angle DOUBLE True
fontleading FontLeading DOUBLE True
wordspacing WordSpacing DOUBLE True
characterwidth CharacterWidth DOUBLE True
characterspacing CharacterSpacing DOUBLE True
flipangle FlipAngle DOUBLE True
override Override LONG True
notes Notes TEXT (1000) True
created_user created_user TEXT (255) True
created_date created_date DATE True
last_edited_user last_edited_user TEXT (255) True
last_edited_date last_edited_date DATE True
shape SHAPE GEOMETRY True
shape_length SHAPE_Length DOUBLE True
shape_area SHAPE_Area DOUBLE True
FeatureClass

AdditionalStructureLines

Class Details
DatasetType ShapeType Alias Has Attachment
FEATURE_CLASS SIMPLE AdditionalStructureLines False
Fields
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG 108 False
assettype Asset type SHORT 0 False
associationstatus Association status SHORT 0 False
subnetworkname Subnetwork name TEXT (2000) Unknown False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
diameter Diameter/Width DOUBLE True
materialcode Material SHORT True
distance Depth/Height DOUBLE True
labeltext Labeling String TEXT (256) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
measuredlength Measured Length DOUBLE True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status_Combined False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
designtype Type SHORT True
diameter_metric Diameter/Width DOUBLE True
created_user created_user TEXT (255) True
created_date created_date DATE True
last_edited_user last_edited_user TEXT (255) True
last_edited_date last_edited_date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape Shape GEOMETRY True
shape_length Shape_Length DOUBLE True
Subtypes
Code Name Description
108 Electric Station
110 Wire Linear Support
145 Wire Linear Crossarm
146 Wire Linear Pole
Subtype: Electric Station
Name Alias Type Default Value Domain Nullable Description
Subtype: Wire Linear Support
Name Alias Type Default Value Domain Nullable Description
Subtype: Wire Linear Crossarm
Name Alias Type Default Value Domain Nullable Description
Subtype: Wire Linear Pole
Name Alias Type Default Value Domain Nullable Description

ServiceTerritory

The networks service territory that represents the operational area of the utility.
Class Details
DatasetType ShapeType Alias Has Attachment
FEATURE_CLASS SIMPLE ServiceTerritory False
Fields
Name Alias Type Default Value Domain Nullable Description
objectid objectid OID False
companyname Company Name TEXT (50) True
globalid GlobalID GUID False
districtname District Name TEXT (50) True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
shape shape GEOMETRY True
shape_length Shape_Length DOUBLE True
shape_area Shape_Area DOUBLE True
Table

JointUse

These are related records to poles, with records of equipment that does not below to the utility.
Class Details
DatasetType ShapeType Alias Has Attachment
TABLE Joint Use True
Fields
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
poleid Pole Number TEXT (50) True
type Type SHORT 0.0 True
height Height DOUBLE True
daterecorded Date Recorded DATE True
poleglobalid Pole Reference GUID True
illegattach Illegally Attached? SHORT Yes_No True
overlashed Overlashed? SHORT Yes_No True
owner Owner SHORT True
globalid GlobalID GUID False
last_edited_date last_edited_date DATE True
created_user created_user TEXT (255) True
created_date created_date DATE True
last_edited_user last_edited_user TEXT (255) True
Subtypes
Code Name Description
0 Unknown Unknown Joint Use information
1 Cable Joint Use cable information
2 Fiber Joint Use fiber cable information
3 Telecommunication Joint Use telecommunications cable information
Subtype: Unknown
Unknown Joint Use information
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
poleid Pole Number TEXT (50) True
type Type SHORT True
height Height DOUBLE True
daterecorded Date Recorded DATE True
poleglobalid Pole Reference GUID True
illegattach Illegally Attached? SHORT Yes_No True
overlashed Overlashed? SHORT Yes_No True
owner Owner SHORT True
globalid GlobalID GUID False
last_edited_date Last Edited Date DATE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
Subtype: Cable
Joint Use cable information
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
poleid Pole Number TEXT (50) True
type Type SHORT True
height Height DOUBLE True
daterecorded Date Recorded DATE True
poleglobalid Pole Reference GUID True
illegattach Illegally Attached? SHORT Yes_No True
overlashed Overlashed? SHORT Yes_No True
owner Owner SHORT Joint_Use_Cable_Owner True
globalid GlobalID GUID False
last_edited_date Last Edited Date DATE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
Subtype: Fiber
Joint Use fiber cable information
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
poleid Pole Number TEXT (50) True
type Type SHORT True
height Height DOUBLE True
daterecorded Date Recorded DATE True
poleglobalid Pole Reference GUID True
illegattach Illegally Attached? SHORT Yes_No True
overlashed Overlashed? SHORT Yes_No True
owner Owner SHORT Joint_Use_Fiber_Owner True
globalid GlobalID GUID False
last_edited_date Last Edited Date DATE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
Subtype: Telecommunication
Joint Use telecommunications cable information
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
poleid Pole Number TEXT (50) True
type Type SHORT True
height Height DOUBLE True
daterecorded Date Recorded DATE True
poleglobalid Pole Reference GUID True
illegattach Illegally Attached? SHORT Yes_No True
overlashed Overlashed? SHORT Yes_No True
owner Owner SHORT Joint_Use_Telecom_Owner True
globalid GlobalID GUID False
last_edited_date Last Edited Date DATE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
Utility Network Domain Classes

ElectricAssembly

The Assembly feature class represents complex point features which contain other devices and lines. Like device features, assembly features are compact features but they differ in that assemblies contain other significant devices. Assemblies are useful to show a single symbol on the map yet model the internal features and their connections. Assemblies can contain devices, lines, and junctions. You can view the internal features of an assembly on the map or in the diagram view.
Class Details
DatasetType ShapeType Alias Has Attachment
FEATURE_CLASS SIMPLE ElectricAssembly True
Fields
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG 0 False
assettype Asset type SHORT 0 False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
configuration Load Breaking SHORT True
powerunits Load LONG True
configuration1 Gang Operated, High Side to Low Side Phase Shift, High Side to Low Side Voltage Shift Range, Maximum Current, Series or Shunt SHORT True
configuration2 High Side to Tertiary Phase Shift, Number of Taps, Phase Operable SHORT True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
ctprimaryratio Primary CT Ratio DOUBLE True
electricunits ElectricUnits LONG True
electricunits2 ElectricUnits2 LONG True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status_Combined False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT Electric_Grid_Level True
gridlevelsource Grid Level Source SHORT Electric_Grid_Level True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
primarytosecondaryvectorgroup Primary to Secondary Winding Vector Group SHORT Electric_Winding_Vector_Group True
primarytotertiaryvectorygroup Primary to Tertiary Winding Vector Group SHORT Electric_Winding_Vector_Group True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtypes
Code Name Description
0 Unknown The Unknown asset group in the ElectricAssembly feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it.
30 Electric Grounding Equipment A collection of equipment used in Electric Grounding Equipment.
31 High Voltage Bay A collection of equipment used in High Voltage Bay
32 Medium Voltage Bay A collection of equipment used in Medium Voltage Bay
33 Low Voltage Bay A collection of equipment used in Low Voltage Bay
1 High Voltage AC Power Factor Correcting Bank A collection of High Voltage AC equipment which is used for power factor correcting purposes. This can include switches, fuses, controllers, and any other equipment used in conjunction with power factor correcting.
2 High Voltage DC Power Factor Correcting Bank A collection of High Voltage DC equipment which is used for power factor correcting purposes. This can include switches, fuses, controllers, and any other equipment used in conjunction with power factor correcting.
24 High Voltage Contoller A Collection of devices used to control High Voltage electric equipment
3 High Voltage Service Bank A collection of equipment used for High Voltage services.
4 High Voltage Switch Bank A collection of equipment used for High Voltage switches.
5 High Voltage Transformer Bank High Voltage Transformer banks are containers used to contain or group electric Transformer equipment and other associated equipment. This feature would be a single symbol on the map that would contain all the individual equipment.
12 Medium Voltage Arrester Bank A collection of equipment used for medium Voltage arresters.
13 Medium Voltage Connector Bank A collection of equipment used for medium Voltage connectors, like flying taps.
25 Medium Voltage Controller A Collection of devices used to control Medium Voltage electric equipment
14 Medium Voltage Fuse Bank A collection of equipment used for medium Voltage fuses.
15 Medium Voltage Power Factor Correcting Bank A collection of Medium Voltage equipment which is used for power factor correcting purposes. This can include switches, fuses, controllers, and any other equipment used in conjunction with power factor correcting.
16 Medium Voltage Regulator Bank A collection of equipment used for medium Voltage regulation.
17 Medium Voltage Service Bank A collection of equipment used for medium Voltage service, like a primary meter.
18 Medium Voltage Switch Bank A collection of equipment used for medium Voltage switches.
19 Medium Voltage Transformer Bank A collection of equipment used for medium Voltage transformers.
20 Medium Voltage Line Monitor and Relay Bank A collection of equipment used for medium Voltage Line Monitors and Relays.
21 Medium Voltage Recloser Bank A collection of equipment used for medium Voltage reclosesrs.
22 Medium Voltage Sectionalizer Bank A collection of equipment used for medium Voltage sectionalizers.
6 Low Voltage Arrester Bank A collection of equipment used for low Voltage arresters.
7 Low Voltage Connector Bank A collection of equipment used for low Voltage connectors, like flying taps.
26 Low Voltage Controller A Collection of devices used to control Low Voltage electric equipment
9 Low Voltage Fuse Bank A collection of individual low voltage fuses, typically used in low voltage mesh systems.
10 Low Voltage Service Bank A collection of low voltage service points at the same general location, used where the user would not want to see a large number of points at smaller scales.
11 Low Voltage Switch Bank A collection of equipment used for low Voltage switches.
8 Low Voltage Transformer Bank A Collection of equipment used for low Voltage transformers.
Subtype: Unknown
The Unknown asset group in the ElectricAssembly feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 UtilityNetwork_5_UnknownAssetType False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT Asset_Manager True
gridlevel Grid Level SHORT True
gridlevelsource Grid Level Source SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Unknown: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Electric Grounding Equipment
A collection of equipment used in Electric Grounding Equipment.
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_Assembly_Electric_Grounding_Equipment False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT Electric_Grid_Level True
gridlevelsource Grid Level Source SHORT Electric_Grid_Level True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Electric Grounding Equipment: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Electric Grounding Equipment. Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
30 Grounding Equipment A collection of grounding equipment used in the grounding system Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Bay
A collection of equipment used in High Voltage Bay
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_Assembly_High_Voltage_Bay False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT Electric_Grid_Level True
gridlevelsource Grid Level Source SHORT Electric_Grid_Level True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: High Voltage Bay: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A collection of high Voltage unknown equipment typically found in a station Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
91 Capacitor A collection of equipment used to connect Capacitors to a high voltage system Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
92 Regulator A collection of Voltage Regulating equipment used in the high voltage system Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
93 Switch A collection of High Voltage switching equipment typically found in a station Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
94 Transformer A collection of high Voltage transformer equipment typically found in a station Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
95 Metering A collection of equipment used to connect meters to a high voltage system Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Bay
A collection of equipment used in Medium Voltage Bay
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_Assembly_Medium_Voltage_Bay False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT Electric_Grid_Level True
gridlevelsource Grid Level Source SHORT Electric_Grid_Level True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Medium Voltage Bay: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A collection of Medium Voltage unknown equipment typically found in a station Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
91 Capacitor A collection of equipment used to connect Capacitors to a medium voltage system Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
92 Regulator A collection of Voltage Regulating equipment used in the medium voltage system Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
93 Switch A collection of Medium Voltage switching equipment typically found in a station Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
94 Transformer A collection of Medium Voltage transformer equipment typically found in a station Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
95 Metering A collection of equipment used to connect meters to a medium voltage system Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Bay
A collection of equipment used in Low Voltage Bay
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_Assembly_Low_Voltage_Bay False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT Electric_Grid_Level True
gridlevelsource Grid Level Source SHORT Electric_Grid_Level True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Low Voltage Bay: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A collection of low Voltage unknown equipment typically found in a station Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
91 Capacitor A collection of equipment used to connect Capacitors to a low voltage system Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
92 Regulator A collection of Voltage Regulating equipment used in the low voltage system Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
93 Switch A collection of Low Voltage switching equipment typically found in a station Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
94 Transformer A collection of low Voltage transformer equipment typically found in a station Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
95 Metering A collection of equipment used to connect meters to a low voltage system Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage AC Power Factor Correcting Bank
A collection of High Voltage AC equipment which is used for power factor correcting purposes. This can include switches, fuses, controllers, and any other equipment used in conjunction with power factor correcting.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Assembly_High_Voltage_AC_Power_Factor_Correcting_Bank False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
powerunits kVAR LONG Electric_High_Voltage_KVAR True
configuration1 Series or Shunt SHORT Electric_Capacitor_Line_Configuration True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT True
gridlevelsource Grid Level Source SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: High Voltage AC Power Factor Correcting Bank: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A container for equipment used in a unknown type of Shunt Capacitor bank in the high voltage AC power system Single terminal ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
1 Series A container for equipment used in a Series Capacitor bank in the high voltage AC power system Single terminal ['E:Bank', 'E:Reactive Power'] CONTAINER DO_NOT_SPLIT END_VERTEX
2 Shunt A container for equipment used in a Shunt Capacitor bank in the high voltage AC power system Single terminal ['E:Bank', 'E:Reactive Power'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage DC Power Factor Correcting Bank
A collection of High Voltage DC equipment which is used for power factor correcting purposes. This can include switches, fuses, controllers, and any other equipment used in conjunction with power factor correcting.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Assembly_High_Voltage_DC_Power_Factor_Correcting_Bank False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
powerunits kVAR LONG Electric_High_Voltage_KVAR True
configuration1 Series or Shunt SHORT Electric_Capacitor_Line_Configuration True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT True
gridlevelsource Grid Level Source SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: High Voltage DC Power Factor Correcting Bank: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A container of equipment associated with a unknown capacitor configuration used in the high voltage DC system Single terminal ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
1 Series A container of equipment associated with a series capacitor used in the high voltage DC system Single terminal ['E:Bank', 'E:Voltage Regulation'] CONTAINER DO_NOT_SPLIT END_VERTEX
2 Shunt A container of equipment associated with a shunt capacitor used in the high voltage DC system Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Contoller
A Collection of devices used to control High Voltage electric equipment
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_Assembly_High_Voltage_Controller False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT Electric_Grid_Level True
gridlevelsource Grid Level Source SHORT Electric_Grid_Level True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: High Voltage Contoller: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A device used to control unknown equipment types in the high voltage system Single terminal ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
24 Station A device used to control a electrical equipment in a station in the high voltage system Single terminal ['E:Bank', 'E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Service Bank
A collection of equipment used for High Voltage services.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Assembly_High_Voltage_Service_Bank False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
powerunits Bank Load in kW LONG Electric_High_Voltage_Load_Watts True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT True
gridlevelsource Grid Level Source SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: High Voltage Service Bank: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A container of unknown customer types in the high voltage system Single terminal ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
41 Industrial Customer A container for high voltage equipment used in industrial service points. Single terminal ['E:Bank', 'E:Load - Customer'] CONTAINER DO_NOT_SPLIT END_VERTEX
42 Utility Customer A container for high voltage equipment used in utility service points. Single terminal ['E:Bank', 'E:Load - Customer'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Switch Bank
A collection of equipment used for High Voltage switches.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Assembly_High_Voltage_Switch_Bank False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
configuration Load Breaking SHORT True
powerunits Maximum Breaking Amps LONG Electric_High_Voltage_Maximum_Interrupting_Current True
configuration1 Maximum Current SHORT Electric_High_Voltage_Maximum_Emergency_Current True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT True
gridlevelsource Grid Level Source SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: High Voltage Switch Bank: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A container of equipment associated with a switch in the high voltage system Single terminal ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
61 AC Circuit Breaker A container of equipment associated with a circuit breaker in the high voltage AC system Single terminal ['E:Bank', 'E:Switch', 'E:Switch - Reclosing'] CONTAINER DO_NOT_SPLIT END_VERTEX
62 AC Line Disconnect A container of aerial equipment associated with a disconnect switch in the high voltage AC system Single terminal ['E:Bank', 'E:Switch', 'E:Switch - Disconnect'] CONTAINER DO_NOT_SPLIT END_VERTEX
63 AC Station Disconnect A container of station located equipment associated with a disconnect switch in the high voltage AC system Single terminal ['E:Bank', 'E:Station', 'E:Switch', 'E:Switch - Disconnect'] CONTAINER DO_NOT_SPLIT END_VERTEX
64 DC Circuit Breaker A container of equipment associated with a circuit breaker in the high voltage DC system Single terminal ['E:Bank', 'E:Switch'] CONTAINER DO_NOT_SPLIT END_VERTEX
65 DC Line Disconnect A container of aerial equipment associated with a disconnect switch in the high voltage DC system Single terminal ['E:Bank', 'E:Switch', 'E:Switch - Disconnect'] CONTAINER DO_NOT_SPLIT END_VERTEX
66 DC Station Load Break A container of station located equipment associated with a load breaking switch in the high voltage DC system Single terminal ['E:Bank', 'E:Station', 'E:Switch', 'E:Switch - Load Break'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Transformer Bank
High Voltage Transformer banks are containers used to contain or group electric Transformer equipment and other associated equipment. This feature would be a single symbol on the map that would contain all the individual equipment.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Assembly_High_Voltage_Transformer_Bank False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
powerunits Bank mVA LONG Electric_High_Voltage_Transformer_VA True
configuration1 High Side to Low Side Phase Shift SHORT Electric_Transformer_Phase_Shift True
configuration2 High Side to Tertiary Phase Shift SHORT Electric_Transformer_Phase_Shift True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
ctprimaryratio Primary CT Ratio DOUBLE True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT True
gridlevelsource Grid Level Source SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
primarytosecondaryvectorgroup Primary to Secondary Winding Vector Group SHORT Electric_Winding_Vector_Group True
primarytotertiaryvectorygroup Primary to Tertiary Winding Vector Group SHORT Electric_Winding_Vector_Group True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: High Voltage Transformer Bank: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown High Voltage Transformer Bank Single terminal ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
81 AC Power A container for high voltage equipment used for AC Power Transformers. Single terminal ['E:Bank', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
82 DC Power A container for high voltage equipment used for DC Power Transformers. Single terminal ['E:Bank', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Arrester Bank
A collection of equipment used for medium Voltage arresters.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Assembly_Medium_Voltage_Arrester_Bank False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT True
gridlevelsource Grid Level Source SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Medium Voltage Arrester Bank: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A container for medium voltage equipment of unknown arresters where no other equipment is used. Single terminal ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
201 Indoor Arrester Bank A container for medium voltage equipment used for indoor arresters where no other equipment is used. Single terminal ['E:Bank', 'E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
202 Line Arrester Bank A container for medium voltage equipment used for line arresters where no other equipment is used. Single terminal ['E:Bank', 'E:Cable - Overhead'] CONTAINER DO_NOT_SPLIT END_VERTEX
203 Station Arrester Bank A container for medium voltage equipment used for station arresters where no other equipment is used. Single terminal ['E:Bank', 'E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Connector Bank
A collection of equipment used for medium Voltage connectors, like flying taps.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Assembly_Medium_Voltage_Connector_Bank False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT True
gridlevelsource Grid Level Source SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Medium Voltage Connector Bank: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Medium Voltage Connector Bank Single terminal ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
360 Flying Tap A container for medium voltage equipment used for taps placed mid span, not close to a pole. Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Controller
A Collection of devices used to control Medium Voltage electric equipment
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_Assembly_Medium_Voltage_Controller False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT Electric_Grid_Level True
gridlevelsource Grid Level Source SHORT Electric_Grid_Level True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Medium Voltage Controller: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Medium Voltage Controller. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
24 Station A collection of control equipment found in a station used to control medium voltage equipment Single terminal ['E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Fuse Bank
A collection of equipment used for medium Voltage fuses.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Assembly_Medium_Voltage_Fuse_Bank False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
powerunits Maximum Amps LONG Electric_Medium_Voltage_Maximum_Continuous_Current True
configuration1 Maximum Current SHORT Electric_Medium_Voltage_Maximum_Emergency_Current True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT True
gridlevelsource Grid Level Source SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Medium Voltage Fuse Bank: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A container for equipment associated with a unknown type of fuse bank used in the medium voltage system Single terminal ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
221 Overhead Disconnect Fuse Holder A container for equipment associated with a overhead fuse bank that can also be used as disconnect switches in the medium voltage system Single terminal ['E:Bank', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Disconnect'] CONTAINER DO_NOT_SPLIT END_VERTEX
222 Overhead Load Break Fuse Holder A container for equipment associated with a overhead fuse bank that can also be used as load breaking switches in the medium voltage system Single terminal ['E:Bank', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Load Break'] CONTAINER DO_NOT_SPLIT END_VERTEX
223 Pad Mounted Disconnect A container for equipment associated with a pad mounted fuse bank that can also be used as disconnect switches in the medium voltage system Single terminal ['E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Disconnect'] CONTAINER DO_NOT_SPLIT END_VERTEX
224 Pad Mounted Load Break A container for equipment associated with a pad mounted fuse bank that can also be used as load breaking switches in the medium voltage system Single terminal ['E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Load Break'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Power Factor Correcting Bank
A collection of Medium Voltage equipment which is used for power factor correcting purposes. This can include switches, fuses, controllers, and any other equipment used in conjunction with power factor correcting.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Assembly_Medium_Voltage_Power_Factor_Correcting_Bank False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
powerunits kVAR LONG Electric_Medium_Voltage_VAR True
configuration1 Series or Shunt SHORT Electric_Capacitor_Line_Configuration True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT True
gridlevelsource Grid Level Source SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Medium Voltage Power Factor Correcting Bank: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A container of equipment associated with a unknown power factor correcting equipment used in the medium voltage system Single terminal ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
241 Mobile Capacitor A container of equipment associated with a mobile capacitor used in the medium voltage system Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
242 Overhead Capacitor A container of equipment associated with a overhead capacitor used in the medium voltage system Single terminal ['E:Bank', 'E:Cable - Overhead'] CONTAINER DO_NOT_SPLIT END_VERTEX
243 Overhead Harmonic Filter A container of equipment associated with a overhead harmonic filter used in the medium voltage system Single terminal ['E:Bank', 'E:Cable - Overhead'] CONTAINER DO_NOT_SPLIT END_VERTEX
244 Pad Mounted Capacitor A container of equipment associated with a pad mounted capacitor used in the medium voltage system Single terminal ['E:Bank', 'E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
245 Pad Mounted Harmonic Filter A container of equipment associated with a pad mounted harmonic filter used in the medium voltage system Single terminal ['E:Bank', 'E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Regulator Bank
A collection of equipment used for medium Voltage regulation.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Assembly_Medium_Voltage_Regulator_Bank False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
powerunits Bank kVA LONG Electric_Medium_Voltage_Regulator_VA True
configuration1 High Side to Low Side Voltage Shift Range SHORT Electric_Transformer_Phase_Shift True
configuration2 Number of Taps SHORT Electric_Transformer_Phase_Shift True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
ctprimaryratio Primary CT Ratio DOUBLE True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT True
gridlevelsource Grid Level Source SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
primarytosecondaryvectorgroup Primary To Secondary Winding Vector Group SHORT Electric_Winding_Vector_Group True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Medium Voltage Regulator Bank: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A container of equipment used in an unknown type of regulator in the medium voltage system Single terminal ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
261 Overhead Single Phase Regulator A container of pole mounted equipment used in a single phase regulator in the medium voltage system Single terminal ['E:Bank', 'E:Cable - Overhead'] CONTAINER DO_NOT_SPLIT END_VERTEX
262 Overhead Single Phase Regulator Delta A container of pole mounted equipment used in a single phase regulator in a delta configuration in the medium voltage system Single terminal ['E:Bank', 'E:Cable - Overhead'] CONTAINER DO_NOT_SPLIT END_VERTEX
264 Overhead Single Phase Regulator Wye A container of pole mounted equipment used in a single phase regulator in a wye configuration in the medium voltage system Single terminal ['E:Bank', 'E:Cable - Overhead'] CONTAINER DO_NOT_SPLIT END_VERTEX
265 Overhead Three Phase Regulator A container of pole mounted equipment used in a three phase regulator in the medium voltage system Single terminal ['E:Bank', 'E:Cable - Overhead'] CONTAINER DO_NOT_SPLIT END_VERTEX
266 Overhead Three Phase Regulator Delta A container of pole mounted equipment used in a three phase regulator in a delta configuration in the medium voltage system Single terminal ['E:Bank', 'E:Cable - Overhead'] CONTAINER DO_NOT_SPLIT END_VERTEX
267 Overhead Three Phase Regulator Open Delta A container of pole mounted equipment used in a three phase regulator in a open delta configuration in the medium voltage system Single terminal ['E:Bank', 'E:Cable - Overhead'] CONTAINER DO_NOT_SPLIT END_VERTEX
268 Overhead Three Phase Regulator Wye A container of pole mounted equipment used in a three phase regulator in a wye configuration in the medium voltage system Single terminal ['E:Bank', 'E:Cable - Overhead'] CONTAINER DO_NOT_SPLIT END_VERTEX
269 Pad Mounted Single Phase Regulator A container of pad mounted equipment used in a single phase regulator in the medium voltage system Single terminal ['E:Bank', 'E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
270 Pad Mounted Three Phase Regulator A container of pad mounted equipment used in a three phase regulator in the medium voltage system Single terminal ['E:Bank', 'E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
271 Pad Mounted Three Phase Regulator Delta A container of pad mounted equipment used in a single phase regulator in a delta configuration in the medium voltage system Single terminal ['E:Bank', 'E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
272 Pad Mounted Three Phase Regulator Wye A container of pad mounted equipment used in a single phase regulator in a wye configuration in the medium voltage system Single terminal ['E:Bank', 'E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Service Bank
A collection of equipment used for medium Voltage service, like a primary meter.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Assembly_Medium_Voltage_Service_Bank False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
powerunits Bank Load LONG True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT True
gridlevelsource Grid Level Source SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Medium Voltage Service Bank: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A container for medium voltage equipment used for serving unknown customer types Single terminal ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
281 PM Commercial Customer A container for medium voltage equipment used for commercial customer services. Single terminal ['E:Bank', 'E:Load - Commercial', 'E:Load - Customer'] CONTAINER DO_NOT_SPLIT END_VERTEX
282 PM Industrial Customer A container for medium voltage equipment used for industrial customer services. Single terminal ['E:Bank', 'E:Load - Customer'] CONTAINER DO_NOT_SPLIT END_VERTEX
283 Primary Meter A container for medium voltage equipment used for primary meters. Single terminal ['E:Bank', 'E:Load - Customer', 'E:Load - Industrial'] CONTAINER DO_NOT_SPLIT END_VERTEX
284 Residential A container for medium voltage equipment used for residential service locations. Single terminal ['E:Bank', 'E:Load - Customer'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Switch Bank
A collection of equipment used for medium Voltage switches.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Assembly_Medium_Voltage_Switch_Bank False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
configuration Load Breaking SHORT Yes_No True
powerunits Bank Load in kW LONG Electric_Medium_Voltage_Maximum_Continuous_Current True
configuration1 Gang Operated SHORT Yes_No True
configuration2 Phase Operable SHORT Yes_No True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT True
gridlevelsource Grid Level Source SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Medium Voltage Switch Bank: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A container of equipment associated with a switch in the medium voltage system Single terminal ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
301 Overhead Disconnect Switch A container of pole mounted equipment associated with a disconnect switch in the medium voltage system Single terminal ['E:Bank', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Disconnect'] CONTAINER DO_NOT_SPLIT END_VERTEX
302 Overhead Load Break Switch A container of pole mounted equipment associated with a load breaking switch in the medium voltage system Single terminal ['E:Bank', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Load Break'] CONTAINER DO_NOT_SPLIT END_VERTEX
305 Station Disconnect Switch A container of station located equipment associated with a disconnect switch in the medium voltage system Single terminal ['E:Bank', 'E:Station', 'E:Switch', 'E:Switch - Disconnect'] CONTAINER DO_NOT_SPLIT END_VERTEX
306 Station Load Break Switch A container of station located equipment associated with a load breaking switch in the medium voltage system Single terminal ['E:Bank', 'E:Station', 'E:Switch', 'E:Switch - Load Break'] CONTAINER DO_NOT_SPLIT END_VERTEX
309 Pad Mounted Switch A container of pad mounted equipment associated with a switch in the medium voltage system Single terminal ['E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Disconnect'] CONTAINER DO_NOT_SPLIT END_VERTEX
310 Overhead Jumper A container of pole mounted jumpers in the medium voltage system Single terminal ['E:Bank', 'E:Cable - Overhead'] CONTAINER DO_NOT_SPLIT END_VERTEX
311 Underground Switch A container of surface or vault located equipment associated with a switch in the medium voltage system Single terminal ['E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Disconnect'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Transformer Bank
A collection of equipment used for medium Voltage transformers.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Assembly_Medium_Voltage_Transformer_Bank False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
powerunits Bank kVA LONG Electric_Medium_Voltage_Transformer_VA True
configuration1 High Side to Low Side Phase Shift SHORT Electric_Transformer_Phase_Shift True
configuration2 High Side to Tertiary Phase Shift SHORT Electric_Transformer_Phase_Shift True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
ctprimaryratio Primary CT Ratio DOUBLE True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT True
gridlevelsource Grid Level Source SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
primarytosecondaryvectorgroup Primary to Secondary Winding Vector Group SHORT Electric_Winding_Vector_Group True
primarytotertiaryvectorygroup Primary To Tertiary Winding Vector Group SHORT Electric_Winding_Vector_Group True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Medium Voltage Transformer Bank: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Medium Voltage Transformer Bank Single terminal ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
321 Overhead Single Phase A container for medium voltage equipment used for pole mounted single phase transformers. Single terminal ['E:Bank', 'E:Cable - Overhead', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
322 Overhead Three Phase A container for medium voltage equipment used for pole mounted three phase transformers. Single terminal ['E:Bank', 'E:Cable - Overhead', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
323 Overhead Three Phase Delta A container for medium voltage equipment used for pole mounted three phase delta transformers and associated equipment. Single terminal ['E:Bank', 'E:Cable - Overhead', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
324 Overhead Open Delta A container for medium voltage equipment used for pole mounted three phase transformers configured in Open Delta. Single terminal ['E:Bank', 'E:Cable - Overhead', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
325 Overhead Open Wye A container for medium voltage equipment used for pole mounted three phase transformers configured in Open Wye. Single terminal ['E:Bank', 'E:Cable - Overhead', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
326 Overhead Three Phase Wye A container for medium voltage equipment used for pole mounted three phase transformers - Wye. Single terminal ['E:Bank', 'E:Cable - Overhead', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
327 Overhead Single Phase Step A collection of equipment used for a overhead transformer used to step voltage up or down on a single phase Single terminal ['E:Bank', 'E:Cable - Overhead', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
328 Overhead Three Phase Step A container of equipment used in a Overhead Three Phase Step Transformer Single terminal ['E:Bank', 'E:Cable - Overhead', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
329 Overhead Three Phase Step Delta A collection of equipment used for a overhead three phase step transformer in a delta configuration Single terminal ['E:Bank', 'E:Cable - Overhead', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
330 Overhead Three Phase Step Wye A collection of equipment used for a overhead three phase step transformer in a wye configuration Single terminal ['E:Bank', 'E:Cable - Overhead', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
331 Overhead Three Phase Step Open Delta A collection of equipment used for a overhead three phase step transformer in a open delta configuration Single terminal ['E:Bank', 'E:Cable - Overhead', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
332 Overhead Three Phase Step Open Wye A collection of equipment used for a overhead three phase step transformer in a open wye configuration Single terminal ['E:Bank', 'E:Cable - Overhead', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
333 Pad Mounted Single Phase A container for medium voltage equipment used for pad mounted single phase transformer. Single terminal ['E:Bank', 'E:Cable - Underground', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
334 Pad Mounted Three Phase A container for medium voltage equipment used for pad mounted three phase transformer. Single terminal ['E:Bank', 'E:Cable - Underground', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
335 Pad Mounted Three Phase Delta A container for medium voltage equipment used for pad mounted three phase delta transformer and associated equipment. Single terminal ['E:Bank', 'E:Cable - Underground', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
336 Pad Mounted Three Phase Wye A container for medium voltage equipment used for pad mounted three phase wye transformer and associated equipment. Single terminal ['E:Bank', 'E:Cable - Underground', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
337 Pad Mounted Single Phase Step A container of equipment associated with a Pad Mounted Single Phase Step transformer Single terminal ['E:Bank', 'E:Cable - Underground', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
338 Pad Mounted Three Phase Step A container of equipment associated with a Pad Mounted Three Phase Step Transformer Single terminal ['E:Bank', 'E:Cable - Underground', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
339 Pad Mounted Three Phase Step Delta A collection of equipment used in a Surface mounted Three Phase Step Transformer, connected in a Delta configuration Single terminal ['E:Bank', 'E:Cable - Underground', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
340 Pad Mounted Three Phase Step Wye A collection of equipment used in a Surface mounted Three Phase Step Transformer, connected in a Wye configuration Single terminal ['E:Bank', 'E:Cable - Underground', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
341 Pad Mounted Open Delta A container for medium voltage equipment used for pad mounted three phase open delta step transformer. Single terminal ['E:Bank', 'E:Cable - Underground', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
342 Pad Mounted Open Wye A container for medium voltage equipment used for pad mounted three phase open wye step transformer. Single terminal ['E:Bank', 'E:Cable - Underground', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
343 Submersible Single Phase A container for medium voltage equipment used for single phase transformer with two terminals that can be submerged. Single terminal ['E:Bank', 'E:Cable - Submersible', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
344 Submersible Three Phase A container for medium voltage equipment used for three phase transformer with two terminals that can be that can be used in locations prone to flooding Single terminal ['E:Bank', 'E:Cable - Submersible', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
345 Network A container for medium voltage equipment used for network transformer. Single terminal ['E:Bank', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Line Monitor and Relay Bank
A collection of equipment used for medium Voltage Line Monitors and Relays.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Assembly_Medium_Voltage_Line_Monitor_and_Relay_Bank False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT True
gridlevelsource Grid Level Source SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Medium Voltage Line Monitor and Relay Bank: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Medium Voltage Line Monitor and Relay Bank. Single terminal ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
290 Fault Indicator Bank A container for medium voltage Fault Indicators. Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
291 Instrument Transformer Bank A container for medium voltage Instrument Transformers. Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
292 Programmable Logic Unit Bank A container for medium voltage Programmable Logic Controllers. Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
293 Remote Transmission Unit Bank A container for medium voltage Remote Transmission Units. Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
294 SCADA Load Monitor Bank A container for medium voltage SCADA Monitoring equipment. Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
295 Relay Bank A container for medium voltage Relaying equipment. Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Recloser Bank
A collection of equipment used for medium Voltage reclosesrs.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Assembly_Medium_Voltage_Recloser_Bank False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
configuration Load Breaking SHORT True
configuration2 Phase Operable SHORT True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT True
gridlevelsource Grid Level Source SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Medium Voltage Recloser Bank: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Medium Voltage Recloser Bank. Single terminal ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
303 Overhead Recloser A container for medium voltage equipment used for pole mounted recloser and associated equipment. Single terminal ['E:Bank', 'E:Cable - Overhead', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Reclosing'] CONTAINER DO_NOT_SPLIT END_VERTEX
307 Pad Mounted Recloser A container for medium voltage equipment used for pad mounted recloser and associated equipment. Single terminal ['E:Bank', 'E:Cable - Underground', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Reclosing'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Sectionalizer Bank
A collection of equipment used for medium Voltage sectionalizers.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Assembly_Medium_Voltage_Sectionalizer_Bank False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
configuration2 Phase Operable SHORT True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT True
gridlevelsource Grid Level Source SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Medium Voltage Sectionalizer Bank: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Medium Voltage Sectionalizer Bank. Single terminal ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
304 Overhead Sectionalizer A container for medium voltage equipment used for pole mounted sectionalizer and associated equipment Single terminal ['E:Bank', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
308 Pad Mounted Sectionalizer A container for medium voltage equipment used for pad mounted sectionalizer and associated equipment. Single terminal ['E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Arrester Bank
A collection of equipment used for low Voltage arresters.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Assembly_Low_Voltage_Arrester_Bank False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT True
gridlevelsource Grid Level Source SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Low Voltage Arrester Bank: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A container for low voltage equipment of unknown arresters where no other equipment is used. Single terminal ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
101 Indoor Arrester Bank A container for low voltage equipment used for indoor arresters where no other equipment exists. Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
102 Line Arrester Bank A container for low voltage equipment used for line arresters where no other equipment exists. Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
103 Station Arrester Bank A container for low voltage equipment used for station arresters where no other equipment exists. Single terminal ['E:Bank', 'E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Connector Bank
A collection of equipment used for low Voltage connectors, like flying taps.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Assembly_Low_Voltage_Connector_Bank False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT True
gridlevelsource Grid Level Source SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Low Voltage Connector Bank: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Low Voltage Connector Bank Single terminal ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
360 Flying Tap A container for low voltage equipment used for taps placed mid span, not close to a pole. Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Controller
A Collection of devices used to control Low Voltage electric equipment
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_Assembly_Low_Voltage_Controller False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT Electric_Grid_Level True
gridlevelsource Grid Level Source SHORT Electric_Grid_Level True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Low Voltage Controller: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Low Voltage Controller. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
24 Station A collection of control equipment found in a station used to control low voltage equipment Single terminal ['E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Fuse Bank
A collection of individual low voltage fuses, typically used in low voltage mesh systems.
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_Assembly_Low_Voltage_Fuse_Bank False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
powerunits Maximum Amps LONG True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT True
gridlevelsource Grid Level Source SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Low Voltage Fuse Bank: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A container for equipment associated with a unknown type of fuse bank used in the low voltage system Single terminal ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
121 AC Fuse A container for equipment associated with a AC Fuse bank in the low voltage system Single terminal ['E:Bank', 'E:Protective'] CONTAINER DO_NOT_SPLIT END_VERTEX
122 DC Fuse A container for equipment associated with a DC Fuse bank in the low voltage system Single terminal ['E:Bank', 'E:Protective'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Service Bank
A collection of low voltage service points at the same general location, used where the user would not want to see a large number of points at smaller scales.
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_Assembly_Low_Voltage_Service_Bank False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
powerunits Bank Load LONG True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT True
gridlevelsource Grid Level Source SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Low Voltage Service Bank: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A container of unknown customer types in the low voltage system Single terminal ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
41 Industrial Customer A container for low voltage equipment used to serve industrial customers. Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
42 Utility Customer A container for low voltage equipment used for utility customers. Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
161 Commercial A container for low voltage equipment used for commercial services. Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
284 Residential A container for low voltage equipment used for residential services. Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Switch Bank
A collection of equipment used for low Voltage switches.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Assembly_Low_Voltage_Switch_Bank False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
configuration Load Breaking SHORT True
powerunits Maximum Breaking Amps LONG Electric_Low_Voltage_Maximum_Continuous_Current True
configuration1 Gang Operated SHORT Electric_Low_Voltage_Maximum_Emergency_Current True
configuration2 Phase Operable SHORT True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT True
gridlevelsource Grid Level Source SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Low Voltage Switch Bank: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A container of equipment associated with a switch in the low voltage system Single terminal ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
181 Overhead AC Disconnect A container of pole mounted equipment associated with a disconnect switch in the low voltage AC system Single terminal ['E:Bank', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Disconnect'] CONTAINER DO_NOT_SPLIT END_VERTEX
182 Overhead AC Load Break A container of pole mounted equipment associated with a load breaking switch in the low voltage AC system Single terminal ['E:Bank', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Load Break'] CONTAINER DO_NOT_SPLIT END_VERTEX
183 Overhead DC Disconnect A container of pole mounted equipment associated with a disconnect switch in the low voltage DC system Single terminal ['E:Bank', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Disconnect'] CONTAINER DO_NOT_SPLIT END_VERTEX
184 Overhead DC Load Break A container of pole mounted equipment associated with a load breaking switch in the low voltage DC system Single terminal ['E:Bank', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Load Break'] CONTAINER DO_NOT_SPLIT END_VERTEX
185 Underground AC Disconnect A container of surface or vault located equipment associated with a disconnect switch in the low voltage AC system Single terminal ['E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Disconnect'] CONTAINER DO_NOT_SPLIT END_VERTEX
186 Underground AC Load Break A container of surface or vault located equipment associated with a load breaking switch in the low voltage AC system Single terminal ['E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Load Break'] CONTAINER DO_NOT_SPLIT END_VERTEX
187 Underground DC Disconnect A container of surface or vault located equipment associated with a disconnect switch in the low voltage DC system Single terminal ['E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Disconnect'] CONTAINER DO_NOT_SPLIT END_VERTEX
188 Underground DC Load Break A container of surface or vault located equipment associated with a load breaking switch in the low voltage DC system Single terminal ['E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Load Break'] CONTAINER DO_NOT_SPLIT END_VERTEX
189 Indoor AC Disconnect A container of indoor located equipment associated with a disconnect switch in the low voltage AC system Single terminal ['E:Bank', 'E:Switch', 'E:Switch - Disconnect'] CONTAINER DO_NOT_SPLIT END_VERTEX
190 Indoor AC Load Break A container of indoor located equipment associated with a load breaking switch in the low voltage AC system Single terminal ['E:Bank', 'E:Switch', 'E:Switch - Load Break'] CONTAINER DO_NOT_SPLIT END_VERTEX
191 Indoor DC Disconnect A container of indoor located equipment associated with a disconnect switch in the low voltage DC system Single terminal ['E:Bank', 'E:Switch', 'E:Switch - Disconnect'] CONTAINER DO_NOT_SPLIT END_VERTEX
192 Indoor DC Load Break A container of indoor located equipment associated with a load breaking switch in the low voltage DC system Single terminal ['E:Bank', 'E:Switch', 'E:Switch - Load Break'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Transformer Bank
A Collection of equipment used for low Voltage transformers.
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_Assembly_Low_Voltage_Transformer_Bank False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
powerunits Bank kVA LONG True
devicecount Contained Count SHORT True
normaloperatingstatus Bank Status TEXT (255) True
ctprimaryratio Primary CT Ratio DOUBLE True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
notes General Notes TEXT (2000) True
maintby Maintained By SHORT 1 Asset_Manager True
gridlevel Grid Level SHORT Electric_Grid_Level True
gridlevelsource Grid Level Source SHORT Electric_Grid_Level True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
primarytosecondaryvectorgroup Primary to Secondary Winding Vector Group SHORT Electric_Winding_Vector_Group True
primarytotertiaryvectorygroup Primary To Tertiary Winding Vector Group SHORT Electric_Winding_Vector_Group True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Low Voltage Transformer Bank: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Low Voltage Transformer Bank. Single terminal ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
8 Transformer Bank A collection of Low Voltage transformers used together to create three phase power Single terminal ['E:Bank', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX

ElectricDevice

The Device feature class represents features through which your utility resource flows and devices can affect your resource in several ways. Devices can optionally have terminals when there are distinct entry points to the device. Devices can be connected to other devices, junctions, and lines. Devices can be contained within assemblies.
Class Details
DatasetType ShapeType Alias Has Attachment
FEATURE_CLASS SIMPLE ElectricDevice True
Fields
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG 0 False
assettype Asset type SHORT 0 False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname Subnetwork name TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT Electric_Operating_Status True
normaloperatingstatus Normal Operating Status SHORT Electric_Operating_Status True
winteroperatingstatus Winter Operating Status SHORT Electric_Operating_Status True
summeroperatingstatus Summer Operating Status SHORT Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Attribution_All False
phasechange Phase Change SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT 0 Electric_Phase_Attribution_All False
phasesenergized Phases Energized SHORT 0 Electric_Phase_Attribution_All True
phasessubstituted Phases Substituted LONG Electric_Medium_Voltage_Phase_Substitution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT 3 Electric_Medium_Low_Voltage_Number_Of_Phases True
designtype Design Type SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration_Transformer_Regulator True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondaryvoltagelinetoline Secondary Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondarygrounding Secondary Winding Grounding SHORT Electric_Ground_Configuration_Transformer_Regulator True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
tertiarygrounding Tertiary Winding Grounding SHORT Electric_Ground_Configuration_Transformer_Regulator True
maxvoltage Maximum Voltage LONG 0 Electric_Combined_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG 0 ELectric_Combined_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status_Combined False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance Sequence Impedance -X0 DOUBLE True
x1r1impedance Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Peak Load LONG True
offpeakload Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
upperrange Upper Tempature Range - Operating DOUBLE True
upperrangemetric Upper Tempature Range - Operating (Metric) DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
lowerrangemetric Lower Tempature Range - Operating (Metric) DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT Yes_No True
p2sphaseshift Phase Shift/Phase Angle SHORT Electric_Phase_Shift True
p2tphaseshift Primary to Tertiary Phase Shift SHORT Electric_Phase_Shift True
timedelay Trip Time Delay SHORT Electric_Trip_Delay_Range True
tripcount Lockout Trip Count SHORT Electric_Trip_Count True
tapmaxchange Tap Maximum Change SHORT Electric_Tap_Change_Percent True
optype Operational Type SHORT True
maximumpower Maximum Power LONG True
minimumpower Min Power LONG True
ratedpower Rated Power LONG True
loadtapchangepercent Load Tap Change (%) SHORT Electric_Tap_Change_Percent True
noloadloss No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
primarytosecondaryvectorgroup Primary to Secondary Winding Vector Group SHORT Electric_Winding_Vector_Group True
primarytotertiaryvectorygroup Primary to Tertiary Winding Vector Group SHORT Electric_Winding_Vector_Group True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT Electric_Device_Operation True
operatingmechanism Equipment Field Operating Mechanism SHORT Electric_Device_OperatingMechanism True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT Yes_No_Simple True
isriser Is Riser SHORT Yes_No_Simple True
hasarrester Has Arrester SHORT Yes_No_Simple True
isvalidloop Participates in a valid loop SHORT Yes_No_Simple True
withstandrating WithstandRating LONG Electric_BIL_Combined True
validationstatus Validation status SHORT 6 True
Subtypes
Code Name Description
0 Unknown The Unknown asset group in the ElectricDevice feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it.
1 Ground Ground junctions represent locations where electrical grounding occurs.
3 High Voltage Control Unit A electronic controller used to control the state of equipment used in high voltage systems, such as switches.
4 High Voltage Generation A generation facility, such as a group or a single turbine, used in the generation of high volume watts.
43 High Voltage Fuse A device used to protect the system from over current conditions, such as faults.
5 High Voltage Line Monitor and Relay Line monitors are frequently used in conjunction with SCADA systems to monitor system conditions.
6 High Voltage Power Conversion A device used to convert power type from AC to DC or DC to AC.
7 High Voltage Power Factor Correcting A device used in the correction of the power factor of AC energy.
8 High Voltage Regulator Voltage Regulator devices represent a device that is used in the regulation of voltage on the electric line. It can be a single or polyphase device.
9 High Voltage Service A service location or load point used in the delivery of high voltage power, frequently thought of as a meter location.
10 High Voltage Switch A switch used to control the flow of energy.
11 High Voltage Transformer Transformer devices represent a single electrical transformer. These devices can be by phase or polyphase.
61 High Voltage Line Hardware
48 High Voltage Transformer Winding
26 Medium Voltage Circuit Breaker A type of switch used as a network controller or start of a circuit or feeder.
27 Medium Voltage Control Unit A electronic controller used to control the state of equipment used in medium voltage systems, such as switches.
28 Medium Voltage Elbow A device that can be opened, like a switch, but is used to connect underground cables to bushings on pad mounted or underground equipment, such as transformers. Since they can be opened, they can have similar operational behavior as to a switch.
29 Medium Voltage Fuse A device used to protect the system from over current conditions, such as faults.
30 Medium Voltage Generation A generation facility, such as a group or a single turbine, used in the generation of medium volumes of watts, such as solar farms .
31 Medium Voltage Line Monitor and Relay Line monitors are frequently used in conjunction with SCADA systems to monitor system conditions.
32 Medium Voltage Motor and Pump Pumps and motors, typically used for waste water or storm water management, considered a critical asset during major outage events.
33 Medium Voltage Power Conversion A device used to convert power type from AC to DC or DC to AC.
34 Medium Voltage Power Factor Correcting A device used in the correction of the power factor of AC energy.
35 Medium Voltage Regulator Voltage Regulator devices represent a device that is used in the regulation of voltage on the electric line. It can be a single or polyphase device.
36 Medium Voltage Service A service location or load point used in the delivery of medium voltage power, frequently thought of as a primary meter.
41 Medium Voltage Recloser A self reclosing switch
42 Medium Voltage Sectionalizer A sectionlizing switch
37 Medium Voltage Switch A switch used to control the flow of energy.
38 Medium Voltage Transformer Transformer devices represent a single electrical transformer. These devices can be by phase or polyphase.
62 Medium Voltage Line Hardware
47 Medium Voltage Transformer Winding
40 Low Voltage Circuit Breaker A circuit breaker used on low voltage equipment, typically inside of a low voltage station
13 Low Voltage Control Unit A electronic controller used to control the state of equipment used in low voltage systems, such as switches.
14 Low Voltage Fuse A device used to protect the system from over current conditions, such as faults.
15 Low Voltage Generation Generation devices typically located at a customer residence, like rooftop solar.
16 Low Voltage Lighting A device used for lighting such as a streetlight or flood light.
17 Low Voltage Line Monitor and Relay Line monitors are frequently used in conjunction with SCADA systems to monitor system conditions.
18 Low Voltage Motor A motor, typically used in industrial operations.
19 Low Voltage Network Protection A device used to prevent energy from flowing in one direction. Typically used in mesh network systems.
20 Low Voltage Power Conversion A device used to convert power type from AC to DC or DC to AC.
21 Low Voltage Power Factor Correcting A device used in the correction of the power factor of AC energy.
22 Low Voltage Service A service location or load point used in the delivery of low voltage power, frequently thought of as a meter location.
23 Low Voltage Switch A switch used to control the flow of energy.
24 Low Voltage Transformer Transformer devices represent a single electrical transformer. These devices can be by phase or polyphase.
44 Low Voltage Wire Connector A non-operable device used to connect and disconnect electrical wires
45 Low Voltage Regulator Voltage Regulator devices represent a device that is used in the regulation of voltage on the electric line.
46 Low Voltage Transformer Winding
Subtype: Unknown
The Unknown asset group in the ElectricDevice feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 UtilityNetwork_5_UnknownAssetType False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
normaloperatingstatus Bank Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Attribution_All False
phasechange Phase Change SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT 0 Electric_Phase_Attribution_All False
phasesenergized Phases Energized SHORT 0 Electric_Phase_Attribution_All True
secondarygrounding Secondary Winding Grounding SHORT Electric_Ground_Configuration True
tertiarygrounding Tertiary Winding Grounding SHORT Electric_Ground_Configuration True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
district District TEXT (255) True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT Asset_Owner True
maintby Maintained By SHORT Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT True
Subtype: Unknown: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Points of unknown type, typically only used during data migration. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Ground
Ground junctions represent locations where electrical grounding occurs.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Ground False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Attribution_All False
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT 0 Electric_Phase_Attribution_All False
phasesenergized Phases Energized SHORT 0 Electric_Phase_Attribution_All True
designtype Ground Type SHORT Electric_Ground_Type True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
primarygroundimpedance Ground Impedance DOUBLE Electric_Impedance_Range True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
optype Material SHORT Electric_Ground_Material True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT True
Subtype: Ground: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Ground Unknown type of Ground Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
31 Bound Single terminal ['Asset Location', 'E:Bank', 'E:Ground'] CONTAINER DO_NOT_SPLIT END_VERTEX
32 Rod Single terminal ['Asset Location', 'E:Bank', 'E:Ground'] CONTAINER DO_NOT_SPLIT END_VERTEX
33 Voltage Grid Single terminal ['Asset Location', 'E:Bank', 'E:Ground'] CONTAINER DO_NOT_SPLIT END_VERTEX
34 Stray Voltage Isolator Single terminal ['Asset Location', 'E:Bank', 'E:Ground'] CONTAINER DO_NOT_SPLIT END_VERTEX
35 Grounding Switch Single terminal ['Asset Location', 'E:Bank', 'E:Ground'] CONTAINER DO_NOT_SPLIT END_VERTEX
36 Cross Bond Single terminal ['Asset Location', 'E:Bank', 'E:Ground'] CONTAINER DO_NOT_SPLIT END_VERTEX
37 Ground Plate Single terminal ['Asset Location', 'E:Bank', 'E:Ground'] CONTAINER DO_NOT_SPLIT END_VERTEX
38 Ground Joint Single terminal ['Asset Location', 'E:Bank', 'E:Ground'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Control Unit
A electronic controller used to control the state of equipment used in high voltage systems, such as switches.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_High_Voltage_Control_Unit False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_High_Voltage_Number_of_Phases True
designtype Closing Type SHORT Electric_Closing_Mode True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_High_Voltage_Nominal_Voltage True
secondaryvoltagelinetoline Closing Phase Offset (Volts) LONG Electric_Voltage_Offset True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
remotecontrollerindicator Remote Control Indicator SHORT Yes_No True
tripmode Single Phase Trip and Lockout SHORT Electric_Trip_Type True
peakload Max Reactive Power LONG Electric_Maximum_Voltage_Change True
offpeakload Min Reactive Power LONG Electric_Maximum_Voltage_Change True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
upperrange Upper Tempature Range - Operating DOUBLE Electric_Temperature_F True
upperrangemetric Upper Tempature Range - Operating (Metric) DOUBLE Electric_Temperature_C True
lowerrange Lower Tempature Range - Operating DOUBLE Electric_Temperature_F True
lowerrangemetric Lower Tempature Range - Operating (Metric) DOUBLE Electric_Temperature_C True
reversetrip Reverse Trip SHORT Yes_No True
p2sphaseshift Closing Phase Angle SHORT Electric_Phase_Whole_Degrees_Positive True
p2tphaseshift Master Angle SHORT Electric_Phase_Whole_Degrees_Positive True
timedelay Trip Time Delay SHORT Electric_Trip_Delay_Range True
tripcount Lockout Trip Count SHORT Electric_Trip_Count True
tapmaxchange Tap Maximum Change SHORT Electric_Short_Percent_Range True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG Electric_Winding_Ratio_Long True
starthour Start Hour of Operation SHORT Electric_Hour True
stophour Stop Hour of Operation SHORT Electric_Hour True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT True
Subtype: High Voltage Control Unit: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Control Unit Unknown type of High Voltage Control Unit. Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
41 Capacitor HV A device used to control a capacitor in the high voltage system Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
42 Switch and Breaker HV A controller used with high voltage switches and breakers. Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
43 Voltage Regulator HV A device used to control a regulator in the high voltage system Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Generation
A generation facility, such as a group or a single turbine, used in the generation of high volume watts.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_High_Voltage_Generation False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_High_Voltage_Number_of_Phases True
designtype Fuel Type SHORT Electric_Generator_Control_Type True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
z0psimpedance Sequence Impedance -Z0ps DOUBLE Electric_Impedance_Range True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE Electric_Impedance_Range True
z1psimpedance Sequence Impedance -Z1ps DOUBLE Electric_Impedance_Range True
x0r0impedance Sequence Impedance -X0/R0pm DOUBLE Electric_Impedance_Range True
x1r1impedance Sequence Impedance -X1/R1 DOUBLE Electric_Impedance_Range True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE Electric_Impedance_Range True
primarygroundimpedance Ground Impedance Rg DOUBLE Electric_Impedance_Range True
gridsidecouplinginductance Primary Grounding Impedance Reactance DOUBLE Electric_Impedance_Range True
remotecontrollerindicator Remote Control Indicator SHORT Yes_No True
equipmentype ANSI Group SHORT Electric_Generation_ANSI_Group_Code True
tapsandpoles Number of Poles SHORT Electric_Generation_Pole_Count True
peakload Max Reactive Power LONG Electric_High_Voltage_Generate_Watts True
offpeakload Min Reactive Power LONG Electric_High_Voltage_Generate_Watts True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
primarygroundimpedance2 Ground Impedance Xg DOUBLE Electric_Impedance_Range True
p2sphaseshift Initial Phase Angle SHORT Electric_Phase_Whole_Degrees True
optype Fuel Type SHORT Electric_Fuel_Type True
maximumpower Maximum Power LONG Electric_High_Voltage_Generate_Watts True
minimumpower Reactive Generation LONG Electric_High_Voltage_Generate_Watts True
ratedpower Rated Power LONG Electric_High_Voltage_Generate_Watts True
powerfactor Power Factor DOUBLE Electric_Power_Factor_Range True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: High Voltage Generation: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Generation Unknown type of High Voltage Generation. Single terminal ['Asset Location', 'E:Bank', 'E:Generation'] CONTAINER DO_NOT_SPLIT END_VERTEX
61 Battery HV A high wattage Battery. Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Generation', 'E:Generation - Storage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
62 Biomass HV A high Wattage Biomass Generator. Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Generation', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
63 Coal HV A high Wattage Generator using Coal. Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Generation', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
64 Gas Turbine HV A high Wattage Generator using Gas Turbine. Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Generation', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
65 Geothermal HV A high Wattage Generator using Geothermal energy. Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Generation', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
66 Hydro HV A high Wattage Generator using Hydro. Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Generation', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
67 Nuclear HV A high Wattage Generator using Nuclear. Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Generation', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
68 Photovoltaic Solar HV A high Wattage Generator using Photovoltaic solar. Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Generation', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
69 Thermal Solar HV A high Wattage Generator using Thermal solar. Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Generation', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
70 Wind HV A high Wattage Generator using Wind. Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Generation', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
71 AC Wave HV A Ocean Wave Generation station providing power to the high voltage system Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Generation', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
72 Generator HV A high voltage energy storage device frequently installed at residences. Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Generation'] CONTAINER DO_NOT_SPLIT END_VERTEX
73 Interconnect HV Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Generation', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Fuse
A device used to protect the system from over current conditions, such as faults.
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_Device_High_Voltage_Fuse False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT 0 Electric_Operating_Status True
normaloperatingstatus Normal Status SHORT 0 Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT 0 Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT 0 Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_High_Voltage_Number_of_Phases True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_High_Voltage_Nominal_Voltage True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
tripcount Lockout Trip Count SHORT Electric_Trip_Count True
optype Fuse Link Type SHORT True
maximumpower Continuous Amps Rating LONG Electric_High_Voltage_Maximum_Current True
minimumpower Interrupting Current LONG Electric_High_Voltage_Maximum_Continuous_Current True
ratedpower Max Interrupting Current LONG Electric_High_Voltage_Maximum_Interrupting_Current True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
isriser Is Riser SHORT Yes_No_Simple True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: High Voltage Fuse: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Fuse Unknown type of High Voltage Fuse. Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
581 AC Station Disconnect Fuse HV An AC Fuse found in a station that is also used as a disconnect switch Circuit Breaker ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
582 AC Station Load Break Fuse HV An AC Fuse found in a station that is also used as a disconnect switch Circuit Breaker ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Station', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
583 AC Load Break Disconnect Fuse HV A AC Fuse that can break load and be used as a Disconnect Simple Switch ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
584 AC Load Break Fuse HV - Controller A AC Fuse that can break load Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
585 AC Disconnect Fuse HV - Controller A AC Fuse used as a Disconnect device that is also a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
586 AC Load Break Disconnect Fuse HV - Controller A AC Fuse that can break load and be used as a Disconnect, also a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Line Monitor and Relay
Line monitors are frequently used in conjunction with SCADA systems to monitor system conditions.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_High_Voltage_Line_Monitor_and_Relay False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_High_Voltage_Number_of_Phases True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_High_Voltage_Nominal_Voltage True
secondaryvoltagelinetoline Closing Phase Offset (Volts) LONG Electric_Phase_Angle_Offset_Range True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
remotecontrollerindicator Remote Control Indicator SHORT Yes_No True
equipmentype Type of Data SHORT Electric_RTU_Data_Type True
tripmode Single Phase Trip and Lockout SHORT Electric_Trip_Type True
peakload Max Reactive Power LONG Electric_Maximum_Voltage_Change True
offpeakload Min Reactive Power LONG Electric_Maximum_Voltage_Change True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
reversetrip Reverse Trip SHORT Yes_No True
p2sphaseshift Closing Phase Angle SHORT Electric_Phase_Whole_Degrees_Positive True
p2tphaseshift Master Angle SHORT Electric_Phase_Whole_Degrees_Positive True
timedelay Trip Time Delay SHORT Electric_Trip_Delay_Range True
tripcount Lockout Trip Count SHORT Electric_Trip_Count True
tapmaxchange Tap Maximum Change SHORT Electric_Short_Percent_Range True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG Electric_Winding_Ratio_Long True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: High Voltage Line Monitor and Relay: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Line Monitor and Relay Unknown type of High Voltage Line Monitor and Relay. Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
80 Fault Indicator HV A Fault indicator used in high voltage systems. Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
81 Instrument Transformer HV An Instrument Transformer used in high voltage systems. Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
82 Load Monitor HV A load monitoring sensor used in high voltage systems. Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
83 Relay HV A relay used in high voltage systems. Relay ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Power Conversion
A device used to convert power type from AC to DC or DC to AC.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_High_Voltage_Power_Conversion False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_High_Voltage_Number_of_Phases True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Rated AC Voltage LONG Electric_High_Voltage_Nominal_Voltage True
secondaryvoltagelinetoline Rated DC Voltage LONG Electric_High_Voltage_DC_Voltage True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
primarygroundimpedance Primary Ground Impedance (ohms) DOUBLE Electric_Device_Resistance_Range True
gridsidecouplinginductance Grid Side Coupling Inductance (ohms) DOUBLE Electric_Device_Resistance_Range True
peakload Peak Generation LONG Electric_High_Voltage_Load_Watts True
offpeakload Normal Generation LONG Electric_High_Voltage_Load_Watts True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
minimumpower DC Input Power LONG Electric_High_Voltage_Generate_Watts True
ratedpower AC Output Power LONG Electric_High_Voltage_Generate_Watts True
powerfactor Power Factor DOUBLE True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: High Voltage Power Conversion: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Power Conversion A device that converts power of unknown type in the high voltage system Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
101 Inverter HV A device that converts input energy from DC to output energy of AC in the high voltage system Inverter ['Asset Location', 'E:Bank', 'E:Power Conversion'] CONTAINER DO_NOT_SPLIT END_VERTEX
102 Rectifier HV A device that converts input energy from AC to output energy of DC in the high voltage system Rectifier ['Asset Location', 'E:Bank', 'E:Power Conversion'] CONTAINER DO_NOT_SPLIT END_VERTEX
103 Bidirectional HV A power conversion device used to convert AC to DC or DC to AC in the high voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Power Conversion'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Power Factor Correcting
A device used in the correction of the power factor of AC energy.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_High_Voltage_Power_Factor_Correcting False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_High_Voltage_Number_of_Phases True
designtype Series or Shunt SHORT Electric_Power_Factor_Correcting_Type True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_High_Voltage_Nominal_Voltage True
secondaryvoltagelinetoline Rated Current LONG Electric_High_Voltage_Maximum_Current True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
primarygroundimpedance Primary Ground Impedance (ohms) DOUBLE Electric_Device_Resistance_Range True
gridsidecouplinginductance Grid Side Coupling Inductance (ohms) DOUBLE Electric_Device_Resistance_Range True
remotecontrollerindicator Remote Control Indicator SHORT Yes_No True
equipmentype Type SHORT Electric_Capacitory_Type True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
upperrange Upper Tempature Range - Operating DOUBLE Electric_Temperature_F True
upperrangemetric Upper Tempature Range - Operating (Metric) DOUBLE Electric_Temperature_C True
lowerrange Lower Tempature Range - Operating DOUBLE Electric_Temperature_F True
lowerrangemetric Lower Tempature Range - Operating (Metric) DOUBLE Electric_Temperature_C True
optype Control Type SHORT Electric_PF_Control_Type True
maximumpower Maximum kVAR LONG Electric_High_Voltage_KVAR True
ratedpower Rated kVAR LONG Electric_High_Voltage_KVAR True
noloadloss Losses LONG Electric_High_Voltage_Load_Loss True
starthour Start Hour of Operation SHORT Electric_Hour True
stophour Stop Hour of Operation SHORT Electric_Hour True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: High Voltage Power Factor Correcting: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Power Factor Correcting A power factor correcting device of unknown type in the high voltage system Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
121 AC Capacitor HV A capacitor used in the AC high voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Reactive Power'] CONTAINER DO_NOT_SPLIT END_VERTEX
122 AC Wave Trap HV A Wave Trap used for Power Line Communications in high voltage systems. Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
123 AC Reactor HV A reactor used in the AC high voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Reactive Power'] CONTAINER DO_NOT_SPLIT END_VERTEX
124 DC Capacitor HV A capacitor used in the DC high voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Reactive Power'] CONTAINER DO_NOT_SPLIT END_VERTEX
125 DC Reactor HV A reactor used in the DC high voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Reactive Power'] CONTAINER DO_NOT_SPLIT END_VERTEX
126 Synchronous Condenser HV Rectifier ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Regulator
Voltage Regulator devices represent a device that is used in the regulation of voltage on the electric line. It can be a single or polyphase device.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_High_Voltage_Regulator False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_High_Voltage_Number_of_Phases True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_High_Voltage_Nominal_Voltage True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE Electric_Tap_Maximum_Change True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE Electric_Load_Tap_Bandwidth True
maximumboost Maximum Voltage Boost DOUBLE Electric_Buck_Boost_Rate True
z0psimpedance Sequence Impedance -Z0ps DOUBLE Electric_Impedance_Range True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE Electric_Impedance_Range True
z1psimpedance Sequence Impedance -Z1ps DOUBLE Electric_Impedance_Range True
x0r0impedance Sequence Impedance -X0/R0pm DOUBLE Electric_Impedance_Range True
x1r1impedance Sequence Impedance -X1/R1 DOUBLE Electric_Impedance_Range True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE Electric_Impedance_Range True
primarygroundimpedance Primary Ground Impedance (ohms) DOUBLE Electric_Impedance_Range True
gridsidecouplinginductance Primary Grounding Impedance Reactance DOUBLE Electric_Impedance_Range True
remotecontrollerindicator Remote Control Indicator SHORT Yes_No True
equipmentype Insulation Type SHORT True
tapsandpoles Number of Taps SHORT Electric_Taps_Range True
directional Bi Directional SHORT Yes_No True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
primarygroundimpedance2 Primary Ground Impedance Xg (ohms) DOUBLE Electric_Impedance_Range True
reversetrip Reverse Trip SHORT Yes_No True
timedelay Trip Time Delay SHORT Electric_Trip_Delay_Range True
tripcount Lockout Trip Count SHORT Electric_Trip_Count True
tapmaxchange Tap Maximum Change SHORT Electric_Tap_Change_Percent True
optype Operational Type SHORT Electric_Regulator_Operation_Type True
maximumpower Maximum kVA LONG Electric_High_Voltage_Regulator_VA True
ratedpower Rated kVA LONG Electric_High_Voltage_Regulator_VA True
loadtapchangepercent Load Tap Change (%) SHORT Electric_Tap_Change_Percent True
noloadloss No Load Loss LONG Electric_High_Voltage_Load_Loss True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG Electric_Winding_Ratio_Long True
maximumbuck Maximum Buck DOUBLE Electric_Regulator_Maximum_Buck_Boost True
buckbandwidth Buck Bandwidth SHORT Electric_Voltage_Bandwidth True
loadtapchangerupperbandwidth Load Tap Changer Upper Bandwidth DOUBLE Electric_Tap_Maximum_Change True
loadtapchangerminimumchange Load Tap Changer Minimum Change DOUBLE Electric_Tap_Maximum_Change True
starthour Start Hour of Operation SHORT Electric_Hour True
stophour Stop Hour of Operation SHORT Electric_Hour True
powerfactor Power Factor DOUBLE Electric_Power_Factor_Range True
coolingtype Cooling Type SHORT Electric_Transformer_Cooling True
inparallel inparallel SHORT Yes_No True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
primarytosecondaryvectorgroup Primary to Secondary Winding Vector Group SHORT Electric_Winding_Vector_Group True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: High Voltage Regulator: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Regulator A voltage regulating device used in the high voltage system Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
171 AC Single Phase HV An Single Phase Voltage Regulator used in High Voltage AC system Voltage Regulator ['Asset Location', 'E:Bank', 'E:Voltage Regulation'] CONTAINER DO_NOT_SPLIT END_VERTEX
172 AC Three Phase HV A three phase voltage regulator used in the high voltage AC system Voltage Regulator ['Asset Location', 'E:Bank', 'E:Voltage Regulation'] CONTAINER DO_NOT_SPLIT END_VERTEX
173 DC Regulator HV An Voltage Regulator used in High Voltage DC system Voltage Regulator ['Asset Location', 'E:Bank', 'E:Voltage Regulation'] CONTAINER DO_NOT_SPLIT END_VERTEX
174 Frequency Converter HV Voltage Regulator ['Asset Location', 'E:Bank', 'E:Voltage Regulation'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Service
A service location or load point used in the delivery of high voltage power, frequently thought of as a meter location.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_High_Voltage_Service False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_High_Voltage_Number_of_Phases True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_High_Voltage_Nominal_Voltage True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
remotecontrollerindicator Remote Control Indicator SHORT Yes_No True
peakload Peak Load LONG Electric_High_Voltage_Service_Load_kW True
offpeakload Off Peak Load LONG Electric_High_Voltage_Service_Load_kW True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
noloadloss No Load Loss LONG Electric_High_Voltage_Load_Loss True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT Yes_No_Simple True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: High Voltage Service: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Service A unknown type of service metering point in the high voltage system Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
161 AC Metering HV A metering device used in the high voltage AC system Single terminal ['Asset Location', 'E:Bank', 'E:Load', 'E:Load - Commercial', 'E:Load - Customer', 'E:Load - Industrial'] CONTAINER DO_NOT_SPLIT END_VERTEX
162 DC Metering HV A metering device used in the high voltage DC system Single terminal ['Asset Location', 'E:Bank', 'E:Load', 'E:Load - Commercial', 'E:Load - Customer', 'E:Load - Industrial'] CONTAINER DO_NOT_SPLIT END_VERTEX
163 High Voltage Premise HV A service location of a customer connected to the high voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Load', 'E:Load - Commercial', 'E:Load - Customer'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Switch
A switch used to control the flow of energy.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_High_Voltage_Switch False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT 0 Electric_Operating_Status True
normaloperatingstatus Normal Status SHORT 0 Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT 0 Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT 0 Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_High_Voltage_Number_of_Phases True
manufacturer Manufacturer SHORT Electric_Device_Switch_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_High_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
remotecontrollerindicator Remote Control Indicator SHORT Yes_No True
tripmode Single Phase Trip and Lockout SHORT Yes_No True
directional Reversible SHORT Yes_No True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
reversetrip Reverse Trip SHORT Yes_No True
timedelay Trip Time Delay SHORT Electric_Trip_Delay_Range True
tripcount Lockout Trip Count SHORT Electric_Trip_Count True
maximumpower Continuous Amps Rating LONG Electric_High_Voltage_Switch_Interrupting_Amps True
minimumpower Maximum Interrupting Current LONG Electric_High_Voltage_Switch_Interrupting_Amps True
ratedpower Rated Current LONG Electric_High_Voltage_Switch_Continuous_Amps True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT Electric_Device_Operation True
operatingmechanism Equipment Field Operating Mechanism SHORT Electric_Device_OperatingMechanism True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
isriser Is Riser SHORT Yes_No_Simple True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: High Voltage Switch: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Switch A unknown switch type used in the high voltage system Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
181 AC Circuit Breaker HV A circuit break used in the high voltage AC system Circuit Breaker ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
182 AC Disconnect HV A disconnect switch used in the high voltage AC system Simple Switch ['Asset Location', 'E:Bank', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
183 AC Switchgear HV An mechanical switch gear used in the high voltage AC system Simple Switch ['Asset Location', 'E:Bank', 'E:Switch', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
184 DC Circuit Breaker HV A circuit breaker device used to dynamically control the flow of energy in a high voltage substation using DC energy. Circuit Breaker ['Asset Location', 'E:Bank', 'E:Protective', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
185 DC Disconnect HV A disconnecting switch used in the high voltage DC system Simple Switch ['Asset Location', 'E:Bank', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
186 DC Switchgear HV A mechanical switchgear used in the high voltage DC system Simple Switch ['Asset Location', 'E:Bank', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
187 AC Bus Tie Breaker HV A switch used to connect busbar in a station in the high voltage AC system Simple Switch ['Asset Location', 'E:Bank', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
188 DC Bus Tie Breaker HV A switch used to connect busbar in a station in the high voltage DC system Simple Switch ['Asset Location', 'E:Bank', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
189 AC Disconnect - Grounded HV A disconnect switch that can be grounded when open used in the high voltage AC system Simple Switch ['Asset Location', 'E:Bank', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
190 AC Recloser HV A mechanical self closing switch used in the high voltage AC system Simple Switch ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
191 AC Circuit Breaker HV - Controller A circuit break used in the high voltage AC system that can also be a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
192 AC Station Load Break Disconnect HV A station located load breaking or disconnecting switch used in the high voltage AC system Circuit Breaker ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
193 AC Station Load Break Disconnect HV - Controller A station located load breaking or disconnecting switch used in the high voltage AC system that can also be used as a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
194 DC Circuit Breaker HV - Controller A circuit breaker device used to dynamically control the flow of energy in a high voltage substation using DC energy, also used as a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
195 AC Disconnect HV - Controller A disconnect switch used in the high voltage AC system that can also be used as a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
196 AC Grounding HV A switch, that when opened can provide ground protection used in the high voltage AC system Ground Switch ['Asset Location', 'E:Bank', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
197 AC Thyristor HV Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Protective', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
198 DC Thyristor HV Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Protective', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
199 AC Transfer Switch HV T-Blade Switch ['Asset Location', 'E:Bank', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Transformer
Transformer devices represent a single electrical transformer. These devices can be by phase or polyphase.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_High_Voltage_Transformer False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_High_Voltage_Number_of_Phases True
designtype Cooling Type SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Primary Nominal Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Primary Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondaryvoltagelinetoline Secondary Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondarygrounding Secondary Winding Grounding SHORT Electric_Ground_Configuration_Transformer_Regulator True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
tertiarygrounding Tertiary Winding Grounding SHORT Electric_Ground_Configuration_Transformer_Regulator True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE Electric_Tap_Maximum_Change True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE Electric_Load_Tap_Bandwidth True
maximumboost Maximum Voltage Boost DOUBLE Electric_Buck_Boost_Rate True
z0psimpedance Sequence Impedance -Z0ps DOUBLE Electric_Impedance_Range True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE Electric_Impedance_Range True
z1psimpedance Sequence Impedance -Z1ps DOUBLE Electric_Impedance_Range True
x0r0impedance Sequence Impedance -X0/R0pm DOUBLE Electric_Impedance_Range True
x1r1impedance Sequence Impedance -X1/R1 DOUBLE Electric_Impedance_Range True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE Electric_Impedance_Range True
primarygroundimpedance Primary Ground Impedance Rg DOUBLE Electric_Impedance_Range True
gridsidecouplinginductance Primary Grounding Impedance Reactance DOUBLE Electric_Impedance_Range True
equipmentype Insulation Type SHORT Electric_XFR_Type True
tapsandpoles Number of Taps SHORT Electric_Taps_Range True
peakload Peak Load LONG Electric_High_Voltage_Load_Watts True
offpeakload Off Peak Load LONG Electric_High_Voltage_Load_Watts True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
primarygroundimpedance2 Primary Ground Impedance Xg DOUBLE Electric_Impedance_Range True
p2sphaseshift Primary to Secondary Phase Shift SHORT Electric_Phase_Shift True
p2tphaseshift Primary to Tertiary Phase Shift SHORT Electric_Phase_Shift True
tapmaxchange Tap Maximum Change SHORT Electric_Tap_Change_Percent True
optype Operational Type SHORT Electric_XFR_Type True
maximumpower Maximum kVA LONG Electric_High_Voltage_Transformer_VA True
ratedpower Rated kVA LONG Electric_High_Voltage_Transformer_VA True
loadtapchangepercent loadtapchangepercent SHORT Electric_Tap_Change_Percent True
noloadloss No Load Loss LONG Electric_High_Voltage_Load_Loss True
secondarygroundimpedance Secondary Ground Impedance Resistance DOUBLE Electric_Impedance_Range True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG Electric_Winding_Ratio_Long True
secondarygroundimpedance2 Secondary Ground Impedance Reactance DOUBLE Electric_Impedance_Range True
loadtapchangerupperbandwidth LTC - Upper Bandwidth DOUBLE Electric_Load_Tap_Bandwidth True
loadtapchangerminimumchange LTC - Minimum Range DOUBLE Electric_Tap_Maximum_Change True
powerfactor Power Factor DOUBLE Electric_Power_Factor_Range True
coolingtype Cooling Type SHORT Electric_Transformer_Cooling True
inparallel inparallel SHORT Yes_No True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
primarytosecondaryvectorgroup Primary to Secondary Winding Vector Group SHORT Electric_Winding_Vector_Group True
primarytotertiaryvectorygroup Primary to Tertiary Winding Vector Group SHORT Electric_Winding_Vector_Group True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: High Voltage Transformer: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Transformer A transformer of unknown type used in the high voltage system Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
201 AC Single Phase - HV->MV An AC Single Phase Power Transformer converting from High Voltage to Medium Voltage Two Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Transformer - Power', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
202 AC Three Phase - HV->MV An AC Three Phase Power Transformer converting from high voltage to medium voltage Two Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Transformer - Power', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
203 DC Power - HV->HV A voltage transformer used inside a substation to change the voltage for DC energy in the high voltage system Two Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Transformer - Power', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
204 Grounding Transformer - HV->MV A specialized transformer for changing the system grounding between the high and medium voltage systems Two Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
205 Station - HV->MV A station located transformer used to convert power from high voltage to medium voltage Two Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Station', 'E:Transformer - Power', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
206 Station Three Winding - HV->HV-HV A three winding transformer that converts an incoming high voltage current to two different output high voltages Three Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Station', 'E:Transformer - Power', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
207 Station Three Winding - HV->HV-MV A three winding transformer that converts an incoming high voltage current to two different voltages, one high and one medium Three Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Station', 'E:Transformer - Power', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
208 Phase Control - HV->HV A transformer that is used to step down the voltage to power the control devices of a circuit or machine in the high voltage system Two Winding ['Asset Location', 'E:Bank', 'E:Load'] CONTAINER DO_NOT_SPLIT END_VERTEX
209 Station Three Winding - HV->HV-LV A three winding transformer that converts an incoming high voltage current to two different voltages, one high and one low Three Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Station', 'E:Transformer - Power', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
210 Station Step Up - MV->HV A transformer used to increase the voltage from medium Voltage levels to high Voltage levels that can be a subnetwork controller Two Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Station', 'E:Transformer - Power', 'E:Transformer - Step', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
211 Station Step - HV->HV A station located transformer used to convert power from high voltage to a different high voltage Two Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Station', 'E:Transformer - Power', 'E:Transformer - Step', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
212 Station Three Winding - HV->MV-MV Three Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Station', 'E:Transformer - Power', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
213 Station Three Winding - HV->MV-LV Three Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Station', 'E:Transformer - Power', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Line Hardware
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_Device_High_Voltage_Line_Hardware False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname Subnetwork name TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Attribution_All False
phasechange Phase Change SHORT True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT 0 Electric_Phase_Attribution_All False
phasesenergized Phases Energized SHORT 0 Electric_Phase_Attribution_All True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Design Type SHORT Electric_Cable_Hardware_Type True
manufacturer Manufacturer SHORT True
grounding Grounding SHORT True
nominalvoltage Nominal Voltage (L-L) LONG True
nominalvoltagelg Nominal Voltage (L-G) LONG True
secondaryvoltagelinetoline Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Grounding SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Grounding SHORT True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance Sequence Impedance -X0 DOUBLE True
x1r1impedance Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
directional Bi Directional/Reversible SHORT True
peakload Peak Load LONG True
offpeakload Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
upperrange Upper Tempature Range - Operating DOUBLE True
upperrangemetric Upper Tempature Range - Operating (Metric) DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
lowerrangemetric Lower Tempature Range - Operating (Metric) DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Tap Maximum Change SHORT True
optype Operational Type SHORT True
maximumpower Maximum Power LONG True
minimumpower Min Power LONG True
ratedpower Rated Power LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user created_user TEXT (255) True
created_date created_date DATE True
last_edited_user last_edited_user TEXT (255) True
last_edited_date last_edited_date DATE True
primarytosecondaryvectorgroup Primary to Secondary Winding Vector Group SHORT True
primarytotertiaryvectorygroup Primary to Tertiary Winding Vector Group SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT True
Subtype: High Voltage Line Hardware: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Line Hardware Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
834 Damper Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
836 Spacer Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
837 Aerial Marker Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
838 Buried Cable Marker Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
839 Submerged Cable Marker Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
840 Overhead Water Crossing Marker Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
841 Airflow Spoiler Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
842 Bird Diverter Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
843 Line Weight Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Transformer Winding
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_Device_High_Voltage_Transformer_Winding False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname Subnetwork name TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
normaloperatingstatus Normal Operating Status SHORT True
winteroperatingstatus Winter Operating Status SHORT True
summeroperatingstatus Summer Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG Electric_Medium_Voltage_Phase_Substitution True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Design Type SHORT True
manufacturer Manufacturer SHORT True
grounding Grounding SHORT True
secondaryvoltagelinetoline Voltage (L-L) LONG Electric_High_Voltage_Nominal_Voltage True
secondaryvoltagelinetoground Voltage (L-G) LONG True
secondarygrounding Grounding SHORT Electric_Ground_Configuration True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance Sequence Impedance -X0 DOUBLE True
x1r1impedance Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
directional Bi Directional/Reversible SHORT True
peakload Peak Load LONG True
offpeakload Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
upperrange Upper Tempature Range - Operating DOUBLE True
upperrangemetric Upper Tempature Range - Operating (Metric) DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
lowerrangemetric Lower Tempature Range - Operating (Metric) DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Tap Maximum Change SHORT True
optype Operational Type SHORT True
maximumpower Maximum Power LONG True
minimumpower Min Power LONG True
ratedpower Rated Power LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user created_user TEXT (255) True
created_date created_date DATE True
last_edited_user last_edited_user TEXT (255) True
last_edited_date last_edited_date DATE True
primarytosecondaryvectorgroup Primary to Secondary Winding Vector Group SHORT True
primarytotertiaryvectorygroup Primary to Tertiary Winding Vector Group SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT True
Subtype: High Voltage Transformer Winding: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Transformer Winding Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
871 AC Transformer Winding HV Transformer Winding ['Asset Location', 'E:Bank', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
872 DC Transformer Winding HV Transformer Winding ['Asset Location', 'E:Bank', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Circuit Breaker
A type of switch used as a network controller or start of a circuit or feeder.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Medium_Voltage_Circuit_Breaker False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT 0 Electric_Operating_Status True
normaloperatingstatus Normal Status SHORT 0 Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT 0 Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT 0 Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG Electric_Medium_Voltage_Phase_Substitution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
gridsidecouplinginductance Source Equivalent Impedance DOUBLE Electric_Impedance_Range True
remotecontrollerindicator Remote Control Indicator SHORT Electric_Remoted_Controlled True
tripmode Single Phase Trip and Lockout SHORT Electric_Trip_Type True
directional Reversible SHORT Yes_No True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
reversetrip Reverse Trip SHORT Yes_No True
p2sphaseshift A Phase Angle SHORT Electric_Phase_Whole_Degrees True
timedelay Trip Time Delay SHORT Electric_Trip_Delay_Range True
tripcount Lockout Trip Count SHORT Electric_Trip_Count True
optype Breaking Medium SHORT Electric_Switch_Breaking_Medium True
maximumpower Continuous Amps Rating LONG Electric_Medium_Voltage_Circuit_Breaker_Interrupting_Amps True
minimumpower Interrupting Current LONG Electric_Medium_Voltage_Circuit_Breaker_Interrupting_Amps True
ratedpower Rated Current LONG Electric_Medium_Voltage_Circuit_Breaker_Continuous_Amps True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT Electric_Device_Operation True
operatingmechanism Equipment Field Operating Mechanism SHORT Electric_Device_OperatingMechanism True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Medium Voltage Circuit Breaker: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Circuit Breaker a mechanical switching device of unknown type in the medium voltage system Circuit Breaker Directional ['E:Bank', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
501 Isolator Switch MV mechanical switch that is used in electric circuits and devices with the main function of effectively isolating two different parts in the medium voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
502 Single Phase Circuit Breaker MV A mechanical switching device used on a single phase in the medium voltage system Circuit Breaker ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Station', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
503 Three Phase Circuit Breaker MV A mechanical switching device used on a three phases in the medium voltage system Circuit Breaker ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Station', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
512 Single Phase Circuit Breaker MV - Controller A mechanical switching device used on a single phase in the medium voltage system that can also be a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Reclosing', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
513 Three Phase Circuit Breaker MV - Controller A mechanical switching device used on a three phases in the medium voltage system that can also be a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Reclosing', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
515 Network Protector MV A specialized switch that disconnects the circuit from the main system when power starts flows in the reverse direction in the medium voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Switch - Circuit Breaker', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Control Unit
A electronic controller used to control the state of equipment used in medium voltage systems, such as switches.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Medium_Voltage_Control_Unit False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
designtype Closing Type SHORT Electric_Closing_Mode True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts) LONG Electric_Voltage_Offset True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
remotecontrollerindicator Remote Control Indicator SHORT Electric_Remoted_Controlled True
tripmode Single Phase Trip and Lockout SHORT Electric_Trip_Type True
peakload Max Reactive Power LONG Electric_Maximum_Voltage_Change True
offpeakload Min Reactive Power LONG Electric_Maximum_Voltage_Change True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
upperrange Upper Tempature Range - Operating DOUBLE Electric_Temperature_F True
upperrangemetric Upper Tempature Range - Operating (Metric) DOUBLE Electric_Temperature_C True
lowerrange Lower Tempature Range - Operating DOUBLE Electric_Temperature_F True
lowerrangemetric Lower Tempature Range - Operating (Metric) DOUBLE Electric_Temperature_C True
reversetrip Reverse Trip SHORT Yes_No True
p2sphaseshift Closing Phase Angle SHORT Electric_Phase_Whole_Degrees_Positive True
p2tphaseshift Master Angle SHORT Electric_Phase_Whole_Degrees_Positive True
timedelay Trip Time Delay SHORT Electric_Trip_Delay_Range True
tripcount Lockout Trip Count SHORT Electric_Trip_Count True
tapmaxchange Over Current % Rated SHORT Electric_Short_Percent_Range True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG Electric_Winding_Ratio_Long True
starthour Start Hour of Operation SHORT Electric_Hour True
stophour Stop Hour of Operation SHORT Electric_Hour True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT True
Subtype: Medium Voltage Control Unit: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Control Unit A device used to control unknown equipment types in the medium voltage system Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
521 Capacitor MV A device used to control a capacitor in the medium voltage system Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
522 Circuit Breaker MV A device used to control a circuit breaker in the medium voltage system Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
523 Recloser MV A device used to control a recloser in the medium voltage system Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
524 Transfer Switch Controller MV A device used to control a transfer switch in the medium voltage system Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
525 Regulator MV A device used to control a regulator in the medium voltage system Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Elbow
A device that can be opened, like a switch, but is used to connect underground cables to bushings on pad mounted or underground equipment, such as transformers. Since they can be opened, they can have similar operational behavior as to a switch.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Medium_Voltage_Elbow False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT 0 Electric_Operating_Status True
normaloperatingstatus Normal Status SHORT 0 Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT 0 Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT 0 Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG Electric_Medium_Voltage_Phase_Substitution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maximumpower Continuous Amps Rating LONG Electric_Medium_Voltage_Fuse_Continuous_Amps True
minimumpower Interrupting Current LONG Electric_Medium_Voltage_Fuse_Interrupting_Amps True
ratedpower Rated Current LONG Electric_Medium_Voltage_Fuse_Continuous_Amps True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Medium Voltage Elbow: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Elbow Medium Voltage Elbow Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
2 AC Underground Single terminal ['Asset Location'] CONTAINER DO_NOT_SPLIT END_VERTEX
5 AC Underground Bank Circuit Breaker ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
541 Load Break Feedthru MV A medium voltage underground load break feedthru. Circuit Breaker ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
542 Load Break Junction MV A medium voltage underground load break junction. Circuit Breaker ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
543 Single Phase Dead Break MV A medium voltage single phase dead break elbow. Circuit Breaker ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
544 Single Phase Load Break MV A medium voltage single phase load break elbow. Circuit Breaker ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
545 Three Phase Dead Break MV A medium voltage three phase dead break elbow. Circuit Breaker ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
546 Three Phase Load Break MV A medium voltage three phase load break elbow. Circuit Breaker ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Fuse
A device used to protect the system from over current conditions, such as faults.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Medium_Voltage_Fuse False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT 0 Electric_Operating_Status True
normaloperatingstatus Normal Status SHORT 0 Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT 0 Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT 0 Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG Electric_Medium_Voltage_Phase_Substitution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
designtype Fuse Type SHORT Electric_Medium_Voltage_Fuse_Rating True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
optype Fuse Element Type SHORT Electric_Medium_Voltage_Fuse_Type True
maximumpower Continuous Amps Rating LONG Electric_Medium_Voltage_Fuse_Continuous_Amps True
minimumpower Interrupting Current LONG Electric_Medium_Voltage_Fuse_Interrupting_Amps True
ratedpower Rated Current LONG Electric_Medium_Voltage_Fuse_Continuous_Amps True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT Electric_Device_Operation True
operatingmechanism Equipment Field Operating Mechanism SHORT Electric_Device_OperatingMechanism True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
isriser Is Riser SHORT Yes_No_Simple True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Medium Voltage Fuse: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Fuse Medium Voltage Fuse Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
1 AC Overhead Single terminal ['Asset Location'] CONTAINER DO_NOT_SPLIT END_VERTEX
2 AC Underground Single terminal ['Asset Location', 'E:Switch'] CONTAINER DO_NOT_SPLIT END_VERTEX
3 AC Station Single terminal ['Asset Location', 'E:Station', 'E:Switch'] CONTAINER DO_NOT_SPLIT END_VERTEX
4 AC Overhead Bank Simple Switch ['Asset Location', 'E:Bank', 'E:Switch'] CONTAINER DO_NOT_SPLIT END_VERTEX
5 AC Underground Bank Simple Switch ['Asset Location', 'E:Bank', 'E:Switch'] CONTAINER DO_NOT_SPLIT END_VERTEX
6 AC Station Bank Circuit Breaker ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch'] CONTAINER DO_NOT_SPLIT END_VERTEX
561 Bayonet Fuse MV A medium voltage bayonet fuse used in underground equipment. Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
562 Fault Limiter Fuse MV A medium voltage fault limiting device. Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
563 Indoor Fuse MV A medium voltage fuse for confined areas. Simple Switch ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
564 Overhead Cutout Disconnect Fuse MV A medium voltage overhead disconnect cutout fuse holder. Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
565 Overhead Cutout Load Break Fuse MV A medium voltage overhead load breaking cutout fuse holder. Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
566 Overhead Cutout Sectionalizer Fuse MV A medium voltage overhead load breaking cutout with a sectionalizer. Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'E:Switch - Sectionalizing'] CONTAINER DO_NOT_SPLIT END_VERTEX
567 Overhead Cutout Solid Blade Fuse MV An Overhead cutout that contains a solid copper blade. One per phase. Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
568 Cabinet Fuse MV A Fuse used in pad mounted equipment. One per phase. Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
569 Underground Fuse MV A underground fuse holder. Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
570 Underground Disconnect Fuse MV A underground disconnect fuse holder. Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
571 Underground Load Break Fuse MV A underground load breaking fuse holder. Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
572 Overhead Cutout Load Break Disconnect Fuse MV A overhead cutout used to house a fuse that can also be used as a disconnect switch in the medium voltage system Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
573 Overhead Cutout Load Break Fuse MV - Controller A medium voltage overhead load breaking cutout fuse holder, also used as a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
574 Overhead Cutout Disconnect Fuse MV - Controller A medium voltage overhead disconnect cutout fuse holder, also used as a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
575 Overhead Cutout Load Break Disconnect Fuse MV - Controller A overhead cutout used to house a fuse that can also be used as a disconnect switch in the medium voltage system that can be used as a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Generation
A generation facility, such as a group or a single turbine, used in the generation of medium volumes of watts, such as solar farms .
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Medium_Voltage_Generation False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
designtype Fuel Type SHORT Electric_Generator_Control_Type True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
secondarygrounding Secondary Winding Grounding SHORT True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
z0psimpedance Sequence Impedance -Z0ps DOUBLE Electric_Impedance_Range True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE Electric_Impedance_Range True
z1psimpedance Sequence Impedance -Z1ps DOUBLE Electric_Impedance_Range True
x0r0impedance Sequence Impedance -X0/R0pm DOUBLE Electric_Impedance_Range True
x1r1impedance Sequence Impedance -X1/R1 DOUBLE Electric_Impedance_Range True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE Electric_Impedance_Range True
primarygroundimpedance Ground Impedance DOUBLE Electric_Impedance_Range True
gridsidecouplinginductance Primary Grounding Impedance Reactance DOUBLE Electric_Impedance_Range True
remotecontrollerindicator Remote Control Indicator SHORT Electric_Remoted_Controlled True
equipmentype ANSI Group SHORT Electric_Generation_ANSI_Group_Code True
tapsandpoles Number of Poles SHORT Electric_Generation_Pole_Count True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
optype Fuel Type SHORT Electric_Fuel_Type True
powerfactor Power Factor DOUBLE Electric_Power_Factor_Range True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
primarytotertiaryvectorygroup Primary to Tertiary Winding Vector Group SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Medium Voltage Generation: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Generation Unknown type of Medium Voltage Generation. Single terminal ['Asset Location', 'E:Bank', 'E:Generation'] CONTAINER DO_NOT_SPLIT END_VERTEX
110 AC Wave MV A Ocean Wave Generation station providing power to the medium voltage system Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Generation', 'E:Generation - Distributed'] CONTAINER DO_NOT_SPLIT END_VERTEX
111 Battery MV A medium wattage Battery. Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Generation', 'E:Generation - Distributed', 'E:Generation - Storage'] CONTAINER DO_NOT_SPLIT END_VERTEX
112 Biomass MV A power generation device connected to the medium voltage system that uses biomass as fuel Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Generation', 'E:Generation - Distributed'] CONTAINER DO_NOT_SPLIT END_VERTEX
113 Generator MV A medium voltage energy storage device frequently installed at residences. Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Generation', 'E:Generation - Distributed'] CONTAINER DO_NOT_SPLIT END_VERTEX
114 Gas Turbine MV A medium Wattage Generator using Gas Turbine. Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Generation', 'E:Generation - Distributed'] CONTAINER DO_NOT_SPLIT END_VERTEX
115 Geothermal MV A medium Wattage Generator using Geothermal energy. Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Generation', 'E:Generation - Distributed'] CONTAINER DO_NOT_SPLIT END_VERTEX
116 Hydro MV A medium Wattage Generator using Hydro. Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Generation', 'E:Generation - Distributed'] CONTAINER DO_NOT_SPLIT END_VERTEX
117 Wind MV A medium wattage Generator using Wind. Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Generation', 'E:Generation - Distributed'] CONTAINER DO_NOT_SPLIT END_VERTEX
118 Photovoltaic Solar MV A medium\ Wattage Generator using Photovoltaic solar. Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Generation', 'E:Generation - Distributed'] CONTAINER DO_NOT_SPLIT END_VERTEX
119 Thermal Solar MV A medium wattage Generator using Thermal solar. Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Generation', 'E:Generation - Distributed'] CONTAINER DO_NOT_SPLIT END_VERTEX
120 Interconnect MV Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Generation', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Line Monitor and Relay
Line monitors are frequently used in conjunction with SCADA systems to monitor system conditions.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Medium_Voltage_Line_Monitor_and_Relay False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts) LONG Electric_Voltage_Offset True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
remotecontrollerindicator Remote Control Indicator SHORT Electric_Remoted_Controlled True
equipmentype Type of Data SHORT Electric_RTU_Data_Type True
tripmode Single Phase Trip and Lockout SHORT Electric_Trip_Type True
tapsandpoles tapsandpoles SHORT True
peakload Max Reactive Power LONG Electric_Maximum_Voltage_Change True
offpeakload Min Reactive Power LONG Electric_Maximum_Voltage_Change True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
reversetrip Reverse Trip SHORT Yes_No True
p2sphaseshift Closing Phase Angle SHORT Electric_Phase_Whole_Degrees_Positive True
p2tphaseshift Master Angle SHORT Electric_Phase_Whole_Degrees_Positive True
timedelay Trip Time Delay SHORT Electric_Trip_Delay_Range True
tripcount Lockout Trip Count SHORT Electric_Trip_Count True
tapmaxchange Tap Maximum Change SHORT Electric_Short_Percent_Range True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG Electric_Winding_Ratio_Long True
powerfactor Power Factor DOUBLE Electric_Power_Factor_Range True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Medium Voltage Line Monitor and Relay: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Line Monitor and Relay Unknown type of Medium Voltage Line Monitor and Relay. Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
601 Fault Indicator MV A Fault indicator used in medium voltage systems. Single terminal ['Asset Location', 'E:Bank', 'Subnetwork Tap'] CONTAINER DO_NOT_SPLIT END_VERTEX
602 Instrument Transformer MV An Instrument Transformer used in medium voltage systems. Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
603 Programmable Logic Unit MV A SCADA device used to control equipment. Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
604 Remote Terminal Unit MV A SCADA device used to communicate and possibly control equipment. Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
605 SCADA Load Monitor MV A load monitoring sensor used in medium voltage systems. Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
606 SCADA Weather Station MV A weather station used in the medium voltage stations. Single terminal ['Asset Location', 'E:Bank', 'E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
607 Relay MV A relay used in medium voltage systems. Relay ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Motor and Pump
Pumps and motors, typically used for waste water or storm water management, considered a critical asset during major outage events.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Medium_Voltage_Motor_and_Pump False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
designtype Motor Type SHORT Electric_Motor_Type True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
z0psimpedance Sequence Impedance -Z0ps DOUBLE Electric_Impedance_Range True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE Electric_Impedance_Range True
z1psimpedance Sequence Impedance -Z1ps DOUBLE Electric_Impedance_Range True
x0r0impedance Sequence Impedance -X0/R0pm DOUBLE Electric_Impedance_Range True
x1r1impedance Sequence Impedance -X1/R1 DOUBLE Electric_Impedance_Range True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE Electric_Impedance_Range True
primarygroundimpedance Impedance Xg DOUBLE Electric_Impedance_Range True
gridsidecouplinginductance Primary Grounding Impedance Reactance DOUBLE Electric_Impedance_Range True
remotecontrollerindicator Remote Control Indicator SHORT Electric_Remoted_Controlled True
equipmentype ANSI Group SHORT Electric_Generation_ANSI_Group_Code True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
primarygroundimpedance2 Impedance Rg DOUBLE Electric_Impedance_Range True
reversetrip Reverse Trip SHORT True
optype Assistance SHORT Electric_Motor_Assistance_Type True
ratedpower Rated Power LONG Electric_Low_Voltage_Transformer_VA True
powerfactor Power Factor DOUBLE Electric_Power_Factor_Range True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Medium Voltage Motor and Pump: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Motor and Pump Medium Voltage Motor and Pump Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
621 Single Phase Motor MV A medium voltage single phase motor. Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
622 Single Phase Pump MV A medium voltage single phase pump and motor. Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
623 Three Phase Motor MV A medium voltage three phase motor. Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
624 Three Phase Pump MV A medium voltage three phase pump and motor. Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Power Conversion
A device used to convert power type from AC to DC or DC to AC.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Medium_Voltage_Power_Conversion False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
secondaryvoltagelinetoline Rated DC Voltage LONG Electric_DC_Low_Voltage_Nominal_Voltage True
secondarygrounding Secondary Winding Grounding SHORT True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
primarygroundimpedance Primary Ground Impedance (ohms) DOUBLE Electric_Device_Resistance_Range True
gridsidecouplinginductance Grid Side Coupling Inductance (ohms) DOUBLE Electric_Device_Resistance_Range True
remotecontrollerindicator Remote Control Indicator SHORT Electric_Remoted_Controlled True
peakload Peak Generation LONG Electric_Medium_Voltage_Load_Watts True
offpeakload Normal Generation LONG Electric_Medium_Voltage_Load_Watts True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maximumpower Maximum Power LONG Electric_Medium_Voltage_Load_Watts True
minimumpower DC Input Power LONG Electric_Medium_Voltage_Load_Watts True
ratedpower AC Output Power LONG Electric_Medium_Voltage_Load_Watts True
powerfactor Power Factor DOUBLE Electric_Power_Factor_Range True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Medium Voltage Power Conversion: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Power Conversion A device that converts power of unknown type in the medium voltage system Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
641 Single Phase Inverter MV A device that converts input energy from DC to output energy of AC in the medium voltage system Inverter ['Asset Location', 'E:Bank', 'E:Power Conversion'] CONTAINER DO_NOT_SPLIT END_VERTEX
642 Single Phase Rectifier MV A device that converts input energy from AC to output energy of DC in the medium voltage system Rectifier ['Asset Location', 'E:Bank', 'E:Power Conversion'] CONTAINER DO_NOT_SPLIT END_VERTEX
643 Three Phase Inverter MV A device that converts input energy from DC to output energy of AC Three Phase in the medium voltage system Inverter ['Asset Location', 'E:Bank', 'E:Power Conversion'] CONTAINER DO_NOT_SPLIT END_VERTEX
644 Three Phase Rectifier MV A device that converts input energy from three phase AC to output energy of DC in the medium voltage system Rectifier ['Asset Location', 'E:Bank', 'E:Power Conversion'] CONTAINER DO_NOT_SPLIT END_VERTEX
645 Single Phase Bidirectional MV A power conversion device used to convert AC to DC or DC to AC in the medium voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Power Conversion'] CONTAINER DO_NOT_SPLIT END_VERTEX
646 Three Phase Bidirectional MV A power conversion device used to convert three phase AC to DC or DC to AC three phase in the medium voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Power Conversion'] CONTAINER DO_NOT_SPLIT END_VERTEX
647 Wave Trap MV Equipment used to prevent high frequency carrier signals of power line communication to unwanted destinations, medium voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Power Conversion'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Power Factor Correcting
A device used in the correction of the power factor of AC energy.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Medium_Voltage_Power_Factor_Correcting False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
designtype Series or Shunt SHORT Electric_Configuration_Type True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
remotecontrollerindicator Remote Control Indicator SHORT Electric_Remoted_Controlled True
equipmentype Type SHORT Electric_Capacitory_Type True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
upperrange Upper Tempature Range - Operating DOUBLE Electric_Temperature_F True
upperrangemetric Upper Tempature Range - Operating (Metric) DOUBLE Electric_Temperature_C True
lowerrange Lower Tempature Range - Operating DOUBLE Electric_Temperature_F True
lowerrangemetric Lower Tempature Range - Operating (Metric) DOUBLE Electric_Temperature_C True
optype Control Type SHORT Electric_PF_Control_Type True
maximumpower Maximum KVAR LONG Electric_Medium_Voltage_KVAR True
ratedpower Rated kVAR LONG Electric_Medium_Voltage_KVAR True
noloadloss Losses LONG Electric_Medium_Voltage_Load_Loss True
starthour Start Hour of Operation SHORT Electric_Hour True
stophour Stop Hour of Operation SHORT Electric_Hour True
powerfactor Power Factor DOUBLE Electric_Power_Factor_Range True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Medium Voltage Power Factor Correcting: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Power Factor Correcting A power factor correcting device of unknown type in the medium voltage system Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
1 AC Overhead Single terminal ['Asset Location', 'E:Reactive Power'] CONTAINER DO_NOT_SPLIT END_VERTEX
2 AC Underground Single terminal ['Asset Location', 'E:Reactive Power'] CONTAINER DO_NOT_SPLIT END_VERTEX
3 AC Station Single terminal ['Asset Location', 'E:Reactive Power', 'E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
4 AC Overhead Bank Single terminal ['Asset Location', 'E:Bank', 'E:Reactive Power'] CONTAINER DO_NOT_SPLIT END_VERTEX
5 AC Underground Bank Single terminal ['Asset Location', 'E:Bank', 'E:Reactive Power'] CONTAINER DO_NOT_SPLIT END_VERTEX
6 AC Station Bank Single terminal ['Asset Location', 'E:Bank', 'E:Reactive Power', 'E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
661 Mobile Capacitor MV A capacitor mounted on a trailer used in the medium voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Reactive Power'] CONTAINER DO_NOT_SPLIT END_VERTEX
664 Overhead Single Phase Capacitor MV A pole mounted single phase capacitor used in the medium voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Reactive Power'] CONTAINER DO_NOT_SPLIT END_VERTEX
665 Overhead Three Phase Capacitor MV A pole mounted three phase capacitor used in the medium voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Reactive Power'] CONTAINER DO_NOT_SPLIT END_VERTEX
666 Overhead Harmonic Filter MV A pole mounted harmonic filter used in the medium voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Cable - Overhead'] CONTAINER DO_NOT_SPLIT END_VERTEX
667 Overhead Reactor MV A pole mounted reactor used in the medium voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Reactive Power'] CONTAINER DO_NOT_SPLIT END_VERTEX
668 Pad Mounted Single Phase Capacitor MV A pad mounted single phase capacitor used in the medium voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Reactive Power'] CONTAINER DO_NOT_SPLIT END_VERTEX
669 Pad Mounted Three Phase Capacitor MV A pad mounted three phase capacitor used in the medium voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Reactive Power'] CONTAINER DO_NOT_SPLIT END_VERTEX
671 Mobile Harmonic Filter MV A harmonic filter mounted on a trailer used in the medium voltage system Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
672 Mobile Reactor MV A reactor mounted on a trailer used in the medium voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Reactive Power'] CONTAINER DO_NOT_SPLIT END_VERTEX
673 Pad Mounted Harmonic Filter MV A pad mounted harmonic filter used in the medium voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Reactive Power'] CONTAINER DO_NOT_SPLIT END_VERTEX
674 Pad Mounted Reactor MV A pad mounted reactor used in the medium voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Reactive Power'] CONTAINER DO_NOT_SPLIT END_VERTEX
675 Station Capacitor MV A capacitor used in the medium voltage system found in a station Single terminal ['Asset Location', 'E:Bank', 'E:Reactive Power', 'E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
676 Station Harmonic Filter MV A harmonic filter used in the medium voltage system found in a station Single terminal ['Asset Location', 'E:Bank', 'E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
677 Station Reactor MV A reactor used in the medium voltage system found in a station Single terminal ['Asset Location', 'E:Bank', 'E:Reactive Power', 'E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
678 Synchronous Condenser MV Rectifier ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Regulator
Voltage Regulator devices represent a device that is used in the regulation of voltage on the electric line. It can be a single or polyphase device.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Medium_Voltage_Regulator False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE Electric_Tap_Maximum_Change True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE Electric_Load_Tap_Bandwidth True
maximumboost Maximum Voltage Boost DOUBLE Electric_Buck_Boost_Rate True
z0psimpedance Sequence Impedance -Z0ps DOUBLE Electric_Impedance_Range True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE Electric_Impedance_Range True
z1psimpedance Sequence Impedance -Z1ps DOUBLE Electric_Impedance_Range True
x0r0impedance Sequence Impedance -X0/R0pm DOUBLE Electric_Impedance_Range True
x1r1impedance Sequence Impedance -X1/R1 DOUBLE Electric_Impedance_Range True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE Electric_Impedance_Range True
primarygroundimpedance Primary Ground Impedance Rg (ohms) DOUBLE Electric_Impedance_Range True
gridsidecouplinginductance Grid Side Coupling Inductance (ohms) DOUBLE Electric_Impedance_Range True
remotecontrollerindicator Remote Control Indicator SHORT Electric_Remoted_Controlled True
equipmentype Insulation Type SHORT Electric_XFR_Type True
tapsandpoles Number of Taps SHORT Electric_Taps_Range True
directional Bi Directional SHORT Yes_No True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
primarygroundimpedance2 Primary Ground Impedance Xg (ohms) DOUBLE Electric_Impedance_Range True
reversetrip Reverse Trip SHORT Yes_No True
timedelay Trip Time Delay SHORT Electric_Trip_Delay_Range True
tripcount Lockout Trip Count SHORT Electric_Trip_Count True
tapmaxchange Tap Maximum Change SHORT Electric_Taps_Range True
optype Operational Type SHORT Electric_Regulator_Operation_Type True
maximumpower Maximum kVA LONG Electric_Medium_Voltage_Regulator_VA True
ratedpower Rated kVA LONG Electric_Medium_Voltage_Regulator_VA True
loadtapchangepercent Load Tap Change (%) SHORT Electric_Tap_Change_Percent True
noloadloss No Load Loss LONG Electric_Medium_Voltage_Load_Loss True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG Electric_Winding_Ratio_Long True
maximumbuck Maximum Buck DOUBLE Electric_Regulator_Maximum_Buck_Boost True
buckbandwidth Buck Bandwidth SHORT Electric_Voltage_Bandwidth True
loadtapchangerupperbandwidth Load Tap Changer Upper Bandwidth DOUBLE Electric_Load_Tap_Bandwidth True
loadtapchangerminimumchange Load Tap Changer Minimum Change DOUBLE Electric_Load_Tap_Bandwidth True
starthour Start Hour of Operation SHORT Electric_Hour True
stophour Stop Hour of Operation SHORT Electric_Hour True
coolingtype Cooling Type SHORT Electric_Transformer_Cooling True
inparallel inparallel SHORT Yes_No True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
primarytosecondaryvectorgroup Primary to Secondary Winding Vector Group SHORT Electric_Winding_Vector_Group True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Medium Voltage Regulator: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Regulator A voltage regulating device used in the medium voltage system Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
1 AC Overhead Single terminal ['Asset Location', 'E:Voltage Regulation'] CONTAINER DO_NOT_SPLIT END_VERTEX
2 AC Underground Single terminal ['Asset Location', 'E:Voltage Regulation'] CONTAINER DO_NOT_SPLIT END_VERTEX
3 AC Station Single terminal ['Asset Location', 'E:Station', 'E:Voltage Regulation'] NONE DO_NOT_SPLIT END_VERTEX
4 AC Overhead Bank Voltage Regulator ['Asset Location', 'E:Bank', 'E:Voltage Regulation'] CONTAINER DO_NOT_SPLIT END_VERTEX
5 AC Underground Bank Voltage Regulator ['Asset Location', 'E:Bank', 'E:Voltage Regulation'] CONTAINER DO_NOT_SPLIT END_VERTEX
6 AC Station Bank Simple Switch ['Asset Location', 'E:Bank', 'E:Station', 'E:Voltage Regulation'] CONTAINER DO_NOT_SPLIT END_VERTEX
681 Overhead Single Phase VR MV An single phase pole mounted voltage regulator used in high voltage AC system Voltage Regulator ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Voltage Regulation'] CONTAINER DO_NOT_SPLIT END_VERTEX
683 Overhead Three Phase VR MV An three phase pole mounted voltage regulator used in high voltage AC system Voltage Regulator ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Voltage Regulation'] CONTAINER DO_NOT_SPLIT END_VERTEX
685 Pad Mounted Single Phase VR MV An single phase pad mounted voltage regulator used in high voltage AC system Voltage Regulator ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Voltage Regulation'] CONTAINER DO_NOT_SPLIT END_VERTEX
687 Pad Mounted Three Phase VR MV An three phase pad mounted voltage regulator used in high voltage AC system Voltage Regulator ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Voltage Regulation'] CONTAINER DO_NOT_SPLIT END_VERTEX
688 Frequency Converter MV A device that converts a current with one frequency to a current with another frequency in the medium voltage AC system Voltage Regulator ['Asset Location', 'E:Bank', 'E:Voltage Regulation'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Service
A service location or load point used in the delivery of medium voltage power, frequently thought of as a primary meter.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Medium_Voltage_Service False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
remotecontrollerindicator Remote Control Indicator SHORT Yes_No True
peakload Peak Load LONG Electric_Medium_Voltage_Load_Watts True
offpeakload Off Peak Load LONG Electric_Medium_Voltage_Load_Watts True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
ratedpower Rated Power LONG Electric_Medium_Voltage_Load_Watts True
noloadloss No Load Loss LONG Electric_Medium_Voltage_Load_Loss True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG Electric_Winding_Ratio_Long True
powerfactor Power Factor DOUBLE True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT Yes_No_Simple True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Medium Voltage Service: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Service A unknown type of service metering point in the medium voltage system Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
701 Primary Meter - Industrial Customer MV A metering device used for a industrial customer in the medium voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Load', 'E:Load - Commercial', 'E:Load - Customer', 'E:Load - Industrial'] CONTAINER DO_NOT_SPLIT END_VERTEX
702 Primary Meter - Utility Customer MV A metering device used for a utility customer in the medium voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Load', 'E:Load - Commercial', 'E:Load - Customer', 'E:Load - Utility'] CONTAINER DO_NOT_SPLIT END_VERTEX
703 Primary Meter Circuit Source MV A metering device used for a utility customer in the medium voltage system that is also a subnetwork controller Circuit Breaker ['Asset Location', 'E:Bank', 'E:Load', 'E:Load - Commercial', 'E:Load - Customer'] CONTAINER DO_NOT_SPLIT END_VERTEX
704 Medium Voltage Premise MV A service location of a customer connected to the medium voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Load - Commercial', 'E:Load - Customer'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Recloser
A self reclosing switch
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Medium_Voltage_Recloser False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT 0 Electric_Operating_Status True
normaloperatingstatus Normal Status SHORT 0 Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT 0 Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT 0 Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG Electric_Medium_Voltage_Phase_Substitution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
remotecontrollerindicator Remote Control Indicator SHORT Electric_Remoted_Controlled True
tripmode Single Phase Trip and Lockout SHORT True
directional Reversible SHORT Yes_No True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
reversetrip Reverse Trip SHORT Yes_No True
timedelay Trip Time Delay SHORT Electric_Trip_Delay_Range True
tripcount Lockout Trip Count SHORT Electric_Trip_Count True
maximumpower Continuous Amps Rating LONG Electric_Medium_Voltage_Recloser_Interrupting_Amps True
minimumpower Interrupting Current LONG Electric_Medium_Voltage_Recloser_Interrupting_Amps True
ratedpower Rated Current LONG Electric_Medium_Voltage_Recloser_Continuous_Amps True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT Electric_Device_Operation True
operatingmechanism Equipment Field Operating Mechanism SHORT Electric_Device_OperatingMechanism True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
isriser Is Riser SHORT Yes_No_Simple True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Medium Voltage Recloser: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Recloser Medium Voltage Recloser Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
1 AC Overhead Single terminal ['Asset Location', 'E:Switch', 'E:Switch - Reclosing', 'E:Switch - Sectionalizing'] CONTAINER DO_NOT_SPLIT END_VERTEX
2 AC Underground Single terminal ['Asset Location', 'E:Switch', 'E:Switch - Reclosing', 'E:Switch - Sectionalizing'] CONTAINER DO_NOT_SPLIT END_VERTEX
4 AC Overhead Bank Simple Switch ['Asset Location', 'E:Bank', 'E:Switch', 'E:Switch - Reclosing', 'E:Switch - Sectionalizing'] CONTAINER DO_NOT_SPLIT END_VERTEX
5 AC Underground Bank Simple Switch ['Asset Location', 'E:Bank', 'E:Switch', 'E:Switch - Reclosing', 'E:Switch - Sectionalizing'] CONTAINER DO_NOT_SPLIT END_VERTEX
730 Overhead Single Phase Recloser MV A medium voltage single phase reclosing switch. Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
734 Overhead Three Phase Recloser MV - Controller A medium voltage three phase reclosing switch where all three phases are operated the same way at all times, also used as a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Reclosing', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
738 Pad Mounted Three Phase Recloser MV - Controller A medium voltage three phase reclosing switch where all three phases are operated the same way at all times, also used as a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Reclosing', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
744 Overhead Three Phase Recloser MV A medium voltage three phase reclosing switch where all three phases are operated the same way at all times. Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
747 Pad Mounted Single Phase Recloser MV A medium voltage single phase reclosing switch. Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
748 Pad Mounted Three Phase Recloser MV A medium voltage three phase reclosing switch where all three phases are operated the same way at all times. Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Sectionalizer
A sectionlizing switch
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Medium_Voltage_Sectionalizer False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT 0 Electric_Operating_Status True
normaloperatingstatus Normal Status SHORT 0 Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT 0 Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT 0 Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG Electric_Medium_Voltage_Phase_Substitution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
remotecontrollerindicator Remote Control Indicator SHORT Electric_Remoted_Controlled True
tripmode Single Phase Trip and Lockout SHORT True
directional Reversible SHORT Yes_No True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
primarygroundimpedance2 Primary Ground Impedance Xg (ohms) DOUBLE True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT Electric_Device_Operation True
operatingmechanism Equipment Field Operating Mechanism SHORT Electric_Device_OperatingMechanism True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
isriser Is Riser SHORT Yes_No_Simple True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Medium Voltage Sectionalizer: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Sectionalizer Medium Voltage Sectionalizer Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
1 AC Overhead Single terminal ['Asset Location', 'E:Switch', 'E:Switch - Section Devices', 'E:Switch - Sectionalizing'] CONTAINER DO_NOT_SPLIT END_VERTEX
2 AC Underground Single terminal ['Asset Location', 'E:Switch', 'E:Switch - Section Devices', 'E:Switch - Sectionalizing'] CONTAINER DO_NOT_SPLIT END_VERTEX
4 AC Overhead Bank Simple Switch ['Asset Location', 'E:Bank', 'E:Switch', 'E:Switch - Section Devices', 'E:Switch - Sectionalizing'] CONTAINER DO_NOT_SPLIT END_VERTEX
5 AC Underground Bank Simple Switch ['Asset Location', 'E:Bank', 'E:Switch', 'E:Switch - Section Devices', 'E:Switch - Sectionalizing'] CONTAINER DO_NOT_SPLIT END_VERTEX
731 Overhead Single Phase Sectionalizer MV A medium voltage single phase overhead sectionalizing switch. Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Sectionalizing'] CONTAINER DO_NOT_SPLIT END_VERTEX
745 Overhead Three Phase Sectionalizer MV A medium voltage three phase overhead sectionalizing switch where all three phases are operated the same way at all times. Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Section Devices', 'E:Switch - Sectionalizing'] CONTAINER DO_NOT_SPLIT END_VERTEX
749 Pad Mounted Single Phase Sectionalizer MV A medium voltage single phase sectionalizing switch used in a cabinet. Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Sectionalizing'] CONTAINER DO_NOT_SPLIT END_VERTEX
750 Pad Mounted Three Phase Sectionalizer MV A medium voltage three phase sectionalizing switch used in a cabinet. Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Section Devices', 'E:Switch - Sectionalizing'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Switch
A switch used to control the flow of energy.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Medium_Voltage_Switch False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT 0 Electric_Operating_Status True
normaloperatingstatus Normal Status SHORT 0 Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT 0 Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT 0 Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG Electric_Medium_Voltage_Phase_Substitution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
manufacturer Manufacturer SHORT Electric_Device_Switch_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
remotecontrollerindicator Remote Control Indicator SHORT Electric_Remoted_Controlled True
tripmode Single Phase Trip and Lockout SHORT Electric_Trip_Type True
directional Reversible SHORT Yes_No True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
reversetrip Reverse Trip SHORT Yes_No True
timedelay Trip Time Delay SHORT Electric_Trip_Delay_Range True
tripcount Lockout Trip Count SHORT Electric_Trip_Count True
optype Breaking Medium SHORT Electric_Switch_Breaking_Medium True
maximumpower Continuous Amps Rating LONG Electric_Medium_Voltage_Switch_Interrupting_Amps True
minimumpower Interrupting Current LONG Electric_Medium_Voltage_Switch_Interrupting_Amps True
ratedpower Rated Current LONG Electric_Medium_Voltage_Switch_Continuous_Amps True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT Electric_Device_Operation True
operatingmechanism Equipment Field Operating Mechanism SHORT Electric_Device_OperatingMechanism True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
isriser Is Riser SHORT Yes_No_Simple True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Medium Voltage Switch: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Switch A unknown switch type used in the medium voltage system Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
1 AC Overhead Single terminal ['Asset Location', 'E:Switch'] CONTAINER DO_NOT_SPLIT END_VERTEX
2 AC Underground Single terminal ['Asset Location', 'E:Switch'] CONTAINER DO_NOT_SPLIT END_VERTEX
3 AC Station Single terminal ['Asset Location', 'E:Station', 'E:Switch'] CONTAINER DO_NOT_SPLIT END_VERTEX
4 AC Overhead Bank Simple Switch ['Asset Location', 'E:Bank', 'E:Switch'] CONTAINER DO_NOT_SPLIT END_VERTEX
5 AC Underground Bank Simple Switch ['Asset Location', 'E:Bank', 'E:Switch'] CONTAINER DO_NOT_SPLIT END_VERTEX
6 AC Station Bank Circuit Breaker ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch'] CONTAINER DO_NOT_SPLIT END_VERTEX
721 Cabinet Bypass MV A medium voltage cabinet bypass switch. Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
722 Cabinet Switch MV A medium voltage cabinet switch. Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
723 Cabinet Switch - Grounded MV A medium voltage Grounding cabinet switch. Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
724 Overhead Bypass MV A mechanical switch that can change between three connections used in the medium voltage system Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
725 Overhead Grounding Switch MV An aerial mounted grounding switch in the medium voltage system Ground Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
726 Overhead Jumper MV An aerial mounted jumper in the medium voltage system Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
727 Station Grounding MV A grounding switch located in a station in the medium voltage system that can also be a subnetwork controller Ground Switch ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
728 Overhead Single Phase Disconnect MV An aerial mounted single phase disconnecting switch in the medium voltage system Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
729 Overhead Single Phase Load Break MV An aerial mounted single phase load breaking switch in the medium voltage system Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
732 Overhead Three Phase Disconnect MV An aerial mounted three phase disconnecting switch in the medium voltage system where all three phases are operated the same way Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
733 Overhead Three Phase Load Break MV An aerial mounted three phase load breaking switch in the medium voltage system where all three phases are operated the same way Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
746 Pad Mounted Fault Interrupter MV A pad mounted switch designed to break faults safely in the medium voltage system Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Protective', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
751 Station Single Phase Disconnect MV A single phase disconnect switch located in a station in the medium voltage system Circuit Breaker ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
752 Station Disconnect MV A disconnecting switch located in a station in the medium voltage system Circuit Breaker ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
753 T Blade MV A multipositional three phase switch typically used a pad mounted switch cabinet in the medium voltage system T-Blade Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
754 V Blade MV A multipositional three phase switch typically used a pad mounted switch cabinet in the medium voltage system V-Blade Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
755 Underground Single Phase Disconnect MV A single phase disconnecting switch in the underground portion of the medium voltage system Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
758 Underground Single Phase Load Break MV A single phase load breaking switch in the underground portion of the medium voltage system Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
759 Underground Three Phase Disconnect MV A three phase disconnecting switch in the underground portion of the medium voltage system Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
760 Underground Three Phase Load Break MV A three phase load breaking switch in the underground portion of the medium voltage system Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
761 Underground Transfer Switch MV A three phase switch that can switch between sources in the underground portion of the medium voltage system Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
765 Bus Tie Breaker MV A switch used to connect busbar in a station in the medium voltage system Circuit Breaker ['Asset Location', 'E:Bank', 'E:Switch', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
766 Station Load Break MV A load breaking switch located in a station in the medium voltage system Circuit Breaker ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
768 Station Disconnect - Grounded MV A disconnecting switch that when open is provides paths to ground located in a station in the medium voltage system Circuit Breaker ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
769 Station Load Break Disconnect MV A disconnect and load breaking switch located in a station in the medium voltage system Circuit Breaker ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
770 Station Disconnect MV - Controller A disconnecting switch located in a station in the medium voltage system that can also be a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
771 Station Load Break MV - Controller A load breaking switch located in a station in the medium voltage system that can also be a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
772 Station Load Break Disconnect MV - Controller A disconnect and load breaking switch located in a station in the medium voltage system that can also be a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Transformer
Transformer devices represent a single electrical transformer. These devices can be by phase or polyphase.
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Medium_Voltage_Transformer False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Primary Nominal Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Primary Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondaryvoltagelinetoline Secondary Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondarygrounding Secondary Winding Grounding SHORT Electric_Ground_Configuration_Transformer_Regulator True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
tertiarygrounding Tertiary Winding Grounding SHORT Electric_Ground_Configuration_Transformer_Regulator True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE Electric_Tap_Maximum_Change True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE Electric_Load_Tap_Bandwidth True
maximumboost Maximum Voltage Boost DOUBLE Electric_Buck_Boost_Rate True
z0psimpedance Sequence Impedance -Z0ps DOUBLE Electric_Impedance_Range True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE Electric_Impedance_Range True
z1psimpedance Sequence Impedance -Z1ps DOUBLE Electric_Impedance_Range True
x0r0impedance Sequence Impedance -X0/R0pm DOUBLE Electric_Impedance_Range True
x1r1impedance Sequence Impedance -X1/R1 DOUBLE Electric_Impedance_Range True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE Electric_Impedance_Range True
primarygroundimpedance Primary Ground Impedance (ohms) DOUBLE Electric_Impedance_Range True
gridsidecouplinginductance Grid Side Coupling Inductance (ohms) DOUBLE Electric_Impedance_Range True
remotecontrollerindicator Remote Control Indicator SHORT Yes_No True
equipmentype Insulation Type SHORT Electric_XFR_Type True
tapsandpoles Number of Taps SHORT Electric_Taps_Range True
peakload Peak Load LONG Electric_Medium_Voltage_Load_Watts True
offpeakload Off Peak Load LONG Electric_Medium_Voltage_Load_Watts True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
primarygroundimpedance2 Primary Ground Impedance Xg (ohms) DOUBLE Electric_Impedance_Range True
p2sphaseshift Primary to Secondary Phase Shift SHORT Electric_Phase_Shift True
p2tphaseshift Primary to Tertiary Phase Shift SHORT Electric_Phase_Shift True
maximumpower Maximum kVA LONG Electric_Medium_Voltage_Transformer_VA True
ratedpower Rated kVA LONG Electric_Medium_Voltage_Transformer_VA True
loadtapchangepercent Load Tap Change (%) SHORT Electric_Tap_Change_Percent True
noloadloss No Load Loss LONG Electric_Medium_Voltage_Load_Loss True
secondarygroundimpedance Secondary Ground Impedance Rg DOUBLE Electric_Impedance_Range True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG Electric_Winding_Ratio_Long True
secondarygroundimpedance2 Secondary Ground Impedance Xg DOUBLE Electric_Impedance_Range True
coolingtype Cooling Type SHORT Electric_Transformer_Cooling True
inparallel inparallel SHORT Yes_No True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
primarytosecondaryvectorgroup Primary to Secondary Winding Vector Group SHORT Electric_Winding_Vector_Group True
primarytotertiaryvectorygroup Primary to Tertiary Winding Vector Group SHORT Electric_Winding_Vector_Group True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
isriser Is Riser SHORT Yes_No_Simple True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Medium Voltage Transformer: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Transformer A transformer of unknown type used in the medium voltage system Two Winding ['E:Bank', 'E:Load'] CONTAINER DO_NOT_SPLIT END_VERTEX
781 Grounding Transformer - MV->MV A specialized transformer for changing the system grounding between the medium voltage system Two Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
782 Mobile Single Phase - MV->LV A trailer mounted single phase voltage transformer that converts from medium voltage to low voltage Two Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Transformer - Distribution', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
783 Mobile Three Phase - MV->LV A trailer mounted three phase voltage transformer that converts from medium voltage to low voltage Two Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Transformer - Distribution', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
784 Network - MV->LV A transformer used to feed underground low voltage mesh networks that allow energy to flow in only one direction from the medium voltage system Two Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Station', 'E:Transformer - Distribution', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
785 Overhead Single Phase - MV->LV A pole mounted single phase transformer used to convert power from medium voltage to low voltage Two Winding ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Load', 'E:Transformer - Distribution', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
786 Station - MV->LV A station located transformer used to convert power from medium voltage to low voltage Two Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Station', 'E:Transformer - Distribution', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
787 Station Three Winding - MV->LV-LV A three winding transformer that converts an incoming medium voltage current to two different voltages, both low voltages Three Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Station', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
788 Overhead Three Phase - MV->LV A pole mounted three phase transformer used to convert power from medium voltage to low voltage Two Winding ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Load', 'E:Transformer - Distribution', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
789 Pad Mounted Single Phase - MV->LV A pad mounted single phase transformer used to convert power from medium voltage to low voltage Two Winding ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Distribution', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
790 Station Three Winding - MV->MV-LV A three winding transformer that converts an incoming medium voltage current to two different voltages, one high and one medium Three Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Station', 'E:Transformer - Distribution', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
792 Pad Mounted Three Phase - MV->LV A pad mounted three phase transformer used to convert power from medium voltage to low voltage Two Winding ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Distribution', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
793 Submersible Single Phase - MV->LV A medium voltage submersible single phase transformer. Two Winding ['Asset Location', 'E:Bank', 'E:Cable - Submersible', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Distribution', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
794 Submersible Three Phase - MV->LV A medium voltage to low voltage three phase transformer that can be used in locations prone to flooding Two Winding ['Asset Location', 'E:Bank', 'E:Cable - Submersible', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Distribution', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
795 Overhead Open Delta - MV->LV A single feature representing pole mounted three phase open delta transformer that converts power from medium voltage to low voltage Two Winding ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Load', 'E:Transformer - Distribution', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
796 Overhead Open Wye - MV->LV A single feature representing pole mounted three phase open wye transformer that converts power from medium voltage to low voltage Two Winding ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Load', 'E:Transformer - Distribution', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
797 Pad Mounted Open Delta - MV->LV A pad mounted three phase transformer using two single phase delta transformers to convert power from medium voltage to low voltage Two Winding ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Distribution', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
798 Pad Mounted Open Wye - MV->LV A pad mounted three phase transformer using two single phase wye transformers to convert power from medium voltage to low voltage Two Winding ['Asset Functional', 'Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Distribution', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
801 Overhead Single Phase Step - MV<->MV A pole mounted single phase transformer used to convert power from medium voltage to a different medium voltage Two Winding Bidirectional ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
802 Overhead Three Phase Step - MV<->MV A pole mounted three phase transformer used to convert power from medium voltage to a different medium voltage Two Winding Bidirectional ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
803 Overhead Single Phase Step - MV->MV A pole mounted single phase transformer used to convert power from medium voltage to a different medium voltage that can also be used as a subnetwork controller Two Winding ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
804 Overhead Three Phase Step - MV->MV A pole mounted three phase transformer used to convert power from medium voltage to a different medium voltage that can also be used as a subnetwork controller Two Winding ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
805 Pad Mounted Single Phase Step - MV<->MV A pad mounted single phase transformer used to convert power from medium voltage to a different medium voltage Two Winding Bidirectional ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
806 Pad Mounted Three Phase Step - MV<->MV A pad mounted three phase transformer used to convert power from medium voltage to a different medium voltage Two Winding Bidirectional ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
807 Pad Mounted Single Phase Step - MV->MV A pad mounted single phase transformer used to convert power from medium voltage to a different medium voltage that can also be used as a subnetwork controller Two Winding ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
808 Pad Mounted Three Phase Step - MV->MV A pad mounted three phase transformer used to convert power from medium voltage to a different medium voltage that can also be used as a subnetwork controller Two Winding ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
809 Submersible Single Phase Step - MV<->MV A medium voltage single phase transformer used to increase or decrease voltage within the medium voltage range that uses a bidirectional terminal configuration that can be used in locations prone to flooding Two Winding Bidirectional ['Asset Location', 'E:Bank', 'E:Cable - Submersible', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
810 Submersible Three Phase Step - MV<->MV A medium voltage three phase transformer used to step up or down the voltage to a different medium voltage level that can be used in locations prone to flooding using a utility network bidirectional terminal configuration Two Winding Bidirectional ['Asset Location', 'E:Bank', 'E:Cable - Submersible', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
811 Submersible Single Phase Step - MV->MV A medium voltage single phase transformer used to increase or decrease voltage within the medium voltage range that uses a directional terminal configuration that can be used in locations prone to flooding Two Winding ['Asset Location', 'E:Bank', 'E:Cable - Submersible', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
812 Submersible Three Phase Step - MV->MV A medium voltage three phase transformer used to step up or down the voltage to a different medium voltage level that can be used in locations prone to flooding using a utility network directional terminal configuration Two Winding ['Asset Location', 'E:Bank', 'E:Cable - Submersible', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
813 Station Step - MV->MV A station located transformer used to convert power from medium voltage to a different medium voltage that can also be used as a subnetwork controller Two Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Station', 'E:Transformer - Step', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
814 Station Step - MV<->MV A station located transformer used to convert power from medium voltage to a different medium voltage Two Winding Bidirectional ['Asset Location', 'E:Bank', 'E:Load', 'E:Station', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
815 Station Step Three Winding - MV->MV-MV A three winding transformer that converts an incoming medium voltage current to two different output medium voltages Three Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Station', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
816 Overhead Three Phase Step Up - LV->MV A pole mounted three phase transformer used to convert power from low voltage to medium voltage that can also be used as a subnetwork controller Two Winding ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
817 Overhead Three Phase Step Up - LV<->MV A pole mounted three phase transformer used to convert power from low voltage to medium voltage Two Winding Bidirectional ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
818 Station Step Up - LV->MV A transformer used to increase the voltage from Low Voltage levels to Medium Voltage levels that can be a subnetwork controller Two Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Station', 'E:Transformer - Step', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
819 Station Step Up - LV<->MV A transformer used to increase the voltage from Low Voltage levels to Medium Voltage levels Two Winding Bidirectional ['Asset Location', 'E:Bank', 'E:Load', 'E:Station', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
820 Pad Mounted Three Phase Step Up - LV->MV A pad mounted single phase transformer used to convert power from low voltage to medium voltage Two Winding ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
821 Pad Mounted Three Phase Step Up - LV<->MV A pad mounted single phase transformer used to convert power from low voltage to medium voltage Two Winding Bidirectional ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
822 Overhead Single Phase Step Up - LV->MV Two Winding ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
823 Overhead Single Phase Step Up - LV<->MV Two Winding Bidirectional ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
824 Pad Mounted Single Phase Step Up - LV->MV Two Winding ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
825 Pad Mounted Single Phase Step Up - LV<->MV Two Winding Bidirectional ['E:Bank'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Line Hardware
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_Device_Medium_Voltage_Line_Hardware False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname Subnetwork name TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Attribution_All False
phasechange Phase Change SHORT True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT 0 Electric_Phase_Attribution_All False
phasesenergized Phases Energized SHORT 0 Electric_Phase_Attribution_All True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Design Type SHORT Electric_Cable_Hardware_Type True
manufacturer Manufacturer SHORT True
grounding Grounding SHORT True
nominalvoltage Nominal Voltage (L-L) LONG True
nominalvoltagelg Nominal Voltage (L-G) LONG True
secondaryvoltagelinetoline Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Grounding SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Grounding SHORT True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance Sequence Impedance -X0 DOUBLE True
x1r1impedance Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
directional Bi Directional/Reversible SHORT True
peakload Peak Load LONG True
offpeakload Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
upperrange Upper Tempature Range - Operating DOUBLE True
upperrangemetric Upper Tempature Range - Operating (Metric) DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
lowerrangemetric Lower Tempature Range - Operating (Metric) DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Tap Maximum Change SHORT True
optype Operational Type SHORT True
maximumpower Maximum Power LONG True
minimumpower Min Power LONG True
ratedpower Rated Power LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user created_user TEXT (255) True
created_date created_date DATE True
last_edited_user last_edited_user TEXT (255) True
last_edited_date last_edited_date DATE True
primarytosecondaryvectorgroup Primary to Secondary Winding Vector Group SHORT True
primarytotertiaryvectorygroup Primary to Tertiary Winding Vector Group SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT True
Subtype: Medium Voltage Line Hardware: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
834 Damper Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
836 Spacer Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
837 Aerial Marker Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
838 Buried Cable Marker Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
839 Submerged Cable Marker Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
840 Overhead Water Crossing Marker Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
841 Airflow Spoiler Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
842 Bird Diverter Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
843 Line Weight Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Transformer Winding
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_Device_Medium_Voltage_Transformer_Winding False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname Subnetwork name TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
normaloperatingstatus Normal Operating Status SHORT True
winteroperatingstatus Winter Operating Status SHORT True
summeroperatingstatus Summer Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG Electric_Medium_Voltage_Phase_Substitution True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Design Type SHORT True
manufacturer Manufacturer SHORT True
secondaryvoltagelinetoline Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
secondaryvoltagelinetoground Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
secondarygrounding Grounding SHORT Electric_Ground_Configuration True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance Sequence Impedance -X0 DOUBLE True
x1r1impedance Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
directional Bi Directional/Reversible SHORT True
peakload Peak Load LONG True
offpeakload Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
upperrange Upper Tempature Range - Operating DOUBLE True
upperrangemetric Upper Tempature Range - Operating (Metric) DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
lowerrangemetric Lower Tempature Range - Operating (Metric) DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT Electric_Phase_Shift True
p2tphaseshift Primary to Tertiary Phase Shift SHORT Electric_Phase_Shift True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Tap Maximum Change SHORT True
optype Operational Type SHORT True
maximumpower Maximum Power LONG True
minimumpower Min Power LONG True
ratedpower Rated Power LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user created_user TEXT (255) True
created_date created_date DATE True
last_edited_user last_edited_user TEXT (255) True
last_edited_date last_edited_date DATE True
primarytosecondaryvectorgroup Primary to Secondary Winding Vector Group SHORT True
primarytotertiaryvectorygroup Primary to Tertiary Winding Vector Group SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT True
Subtype: Medium Voltage Transformer Winding: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Transformer Winding Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
873 Transformer Winding MV Transformer Winding ['Asset Location', 'E:Bank', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Circuit Breaker
A circuit breaker used on low voltage equipment, typically inside of a low voltage station
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Low_Voltage_Circuit_Breaker False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT 0 Electric_Operating_Status True
normaloperatingstatus Normal Status SHORT 0 Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT 0 Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT 0 Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG Electric_Low_Voltage_Phase_Substitution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
remotecontrollerindicator Remote Control Indicator SHORT Yes_No True
tripmode Single Phase Trip and Lockout SHORT Electric_Trip_Type True
directional Reversible SHORT Yes_No True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
reversetrip Reverse Trip SHORT Yes_No True
timedelay Trip Time Delay SHORT Electric_Trip_Delay_Range True
tripcount Lockout Trip Count SHORT Electric_Trip_Count True
optype Operational Type SHORT Electric_Switch_Breaking_Medium True
maximumpower Continuous Amps Rating LONG Electric_Low_Voltage_Circuit_Breaker_Interrupting_Amps True
minimumpower Interrupting Current LONG Electric_Low_Voltage_Circuit_Breaker_Interrupting_Amps True
ratedpower Rated Current LONG Electric_Low_Voltage_Circuit_Breaker_Continuous_Amps True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Low Voltage Circuit Breaker: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Circuit Breaker a mechanical switching device of unknown type in the low voltage system Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
1 AC Overhead Single terminal ['Asset Location', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Reclosing'] CONTAINER DO_NOT_SPLIT END_VERTEX
2 AC Underground Single terminal ['Asset Location', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Reclosing'] CONTAINER DO_NOT_SPLIT END_VERTEX
3 AC Station Single terminal ['Asset Location', 'E:Station', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Reclosing'] CONTAINER DO_NOT_SPLIT END_VERTEX
4 AC Overhead Bank Circuit Breaker ['Asset Location', 'E:Bank', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Reclosing'] CONTAINER DO_NOT_SPLIT END_VERTEX
5 AC Underground Bank Circuit Breaker ['Asset Location', 'E:Bank', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Reclosing'] CONTAINER DO_NOT_SPLIT END_VERTEX
6 AC Station Bank Circuit Breaker ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Reclosing'] CONTAINER DO_NOT_SPLIT END_VERTEX
11 DC Overhead Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
12 DC Underground Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
13 DC Station Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
14 DC Overhead Bank Circuit Breaker ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
15 DC Underground Bank Circuit Breaker ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
16 DC Station Bank Circuit Breaker ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
471 AC Circuit Breaker LV A mechanical switching device used in the low voltage AC system Circuit Breaker ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
472 DC Circuit Breaker LV A mechanical switching device used in the low voltage DC system Circuit Breaker ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
473 AC Circuit Breaker LV - Controller A mechanical switching device used in the low voltage AC system that can also be a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
474 DC Circuit Breaker LV - Controller A mechanical switching device used in the low voltage DC system that can also be a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Control Unit
A electronic controller used to control the state of equipment used in low voltage systems, such as switches.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Low_Voltage_Control_Unit False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
designtype Closing Type SHORT Electric_Closing_Mode True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts) LONG Electric_Voltage_Offset True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
remotecontrollerindicator Remote Control Indicator SHORT Yes_No True
tripmode Single Phase Trip and Lockout SHORT Electric_Trip_Type True
peakload Max Reactive Power LONG Electric_Maximum_Voltage_Change True
offpeakload Min Reactive Power LONG Electric_Maximum_Voltage_Change True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
upperrange Upper Tempature Range - Operating DOUBLE Electric_Temperature_F True
upperrangemetric Upper Tempature Range - Operating (Metric) DOUBLE Electric_Temperature_C True
lowerrange Lower Tempature Range - Operating DOUBLE Electric_Temperature_F True
lowerrangemetric Lower Tempature Range - Operating (Metric) DOUBLE Electric_Temperature_C True
reversetrip Reverse Trip SHORT Yes_No True
p2sphaseshift Closing Phase Angle SHORT Electric_Phase_Whole_Degrees_Positive True
p2tphaseshift Master Angle SHORT Electric_Phase_Whole_Degrees_Positive True
timedelay Trip Time Delay SHORT Electric_Trip_Delay_Range True
tripcount Lockout Trip Count SHORT Electric_Trip_Count True
tapmaxchange Over Current % Rated SHORT Electric_Short_Percent_Range True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG Electric_Winding_Ratio_Long True
starthour Start Hour of Operation SHORT Electric_Hour True
stophour Stop Hour of Operation SHORT Electric_Hour True
powerfactor Power Factor DOUBLE Electric_Power_Factor_Range True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Low Voltage Control Unit: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Control Unit A device used to control unknown equipment types in the low voltage system Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
241 Control Unit LV A device used to control a electrical equipment in the low voltage system Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Fuse
A device used to protect the system from over current conditions, such as faults.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Low_Voltage_Fuse False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT 0 Electric_Operating_Status True
normaloperatingstatus Normal Status SHORT 0 Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT 0 Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT 0 Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG Electric_Low_Voltage_Phase_Substitution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
designtype Fuse Type SHORT Electric_Low_Voltage_Fuse_Type True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
optype Fuse Link Type SHORT Electric_Low_Voltage_Fuse_Link_Type True
maximumpower Continuous Amps Rating LONG Electric_Low_Voltage_Fuse_Continuous_Amps True
minimumpower Interrupting Current LONG Electric_Low_Voltage_Fuse_Interrupting_Amps True
ratedpower Rated Current LONG Electric_Low_Voltage_Fuse_Continuous_Amps True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT Electric_Device_Operation True
operatingmechanism Equipment Field Operating Mechanism SHORT Electric_Device_OperatingMechanism True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
isriser Is Riser SHORT Yes_No_Simple True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Low Voltage Fuse: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Fuse Low Voltage Fuse Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
1 AC Overhead Single terminal ['Asset Location', 'E:Switch'] CONTAINER DO_NOT_SPLIT END_VERTEX
2 AC Underground Single terminal ['Asset Location', 'E:Switch'] CONTAINER DO_NOT_SPLIT END_VERTEX
3 AC Station Single terminal ['Asset Location', 'E:Station', 'E:Switch'] CONTAINER DO_NOT_SPLIT END_VERTEX
4 AC Overhead Bank Simple Switch ['Asset Location', 'E:Bank', 'E:Switch'] CONTAINER DO_NOT_SPLIT END_VERTEX
5 AC Underground Bank Simple Switch ['Asset Location', 'E:Bank', 'E:Switch'] CONTAINER DO_NOT_SPLIT END_VERTEX
6 AC Station Bank Simple Switch ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch'] CONTAINER DO_NOT_SPLIT END_VERTEX
11 DC Overhead Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
12 DC Underground Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
13 DC Station Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
14 DC Overhead Bank Simple Switch ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
15 DC Underground Bank Simple Switch ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
16 DC Station Bank Simple Switch ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
259 Service Fuse Load Break LV Circuit Breaker ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
260 Service Fuse Disconnect LV Circuit Breaker ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
261 AC Overhead Fuse LV An AC overhead fuse Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
262 AC Underground Fuse LV An AC underground conductor that represents some number of physical cables. Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
263 DC Overhead Fuse LV A DC overhead conductor that represents some number of physical cables. Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
264 DC Underground Fuse LV A DC underground conductor that represents some number of physical cables. Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
265 AC Overhead Load Break Fuse LV An AC Overhead Fuse used as a load breaking switch Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
266 AC Overhead Fuse LV - Controller An AC overhead fuse used as a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
267 AC Underground Load Break Fuse LV A fuse that can be used as a load breaking switch used in the underground part of a low voltage system Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
268 AC Underground Fuse LV - Controller An AC underground conductor that represents some number of physical cables, also used as a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
269 DC Overhead Fuse LV - Controller A DC overhead conductor that represents some number of physical cables, also used as a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
270 DC Underground Fuse LV - Controller A DC underground conductor that represents some number of physical cables, also used as a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
271 AC Overhead Cutout Load Break Disconnect Fuse LV An AC overhead fuse also used as a disconnect and Load breaking switch Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
272 AC Overhead Cutout Load Break Fuse LV - Controller An AC overhead fuse also used as a Load breaking switch and as a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
273 AC Overhead Cutout Disconnect Fuse LV - Controller An AC overhead fuse also used as a disconnect switch with and as a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
274 AC Overhead Cutout Load Break Fuse LV An AC overhead fuse also used as a Load breaking switch Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
275 Station Disconnect Fuse LV A fuse found in a station that can also be used as a disconnect switch in the low voltage system Circuit Breaker ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
276 Station Load Break Fuse LV A fuse found in a station that can also be used as a load breaking switch in the low voltage system Circuit Breaker ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Station', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
277 Station Load Break Disconnect Fuse LV A fuse found in a station that can also be used as a disconnect or load breaking switch in the low voltage system Circuit Breaker ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
278 Station Disconnect Fuse LV - Controller A fuse found in a station that can also be used as a disconnect switch in the low voltage system and can be a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
279 Station Load Break Fuse LV - Controller A fuse found in a station that can also be used as a load breaking switch in the low voltage system and is a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Station', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
280 Station Load Break Disconnect Fuse LV - Controller A fuse found in a station that can also be used as a disconnect or load breaking switch in the low voltage system and can be a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Protective', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Generation
Generation devices typically located at a customer residence, like rooftop solar.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Low_Voltage_Generation False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
designtype Fuel Type SHORT Electric_Generator_Control_Type True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
z0psimpedance Sequence Impedance -Z0ps DOUBLE Electric_Impedance_Range True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE Electric_Impedance_Range True
z1psimpedance Sequence Impedance -Z1ps DOUBLE Electric_Impedance_Range True
x0r0impedance Sequence Impedance -X0/R0pm DOUBLE Electric_Impedance_Range True
x1r1impedance Sequence Impedance -X1/R1 DOUBLE Electric_Impedance_Range True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE Electric_Impedance_Range True
primarygroundimpedance Ground Impedance DOUBLE Electric_Impedance_Range True
gridsidecouplinginductance Primary Grounding Impedance Reactance DOUBLE Electric_Impedance_Range True
remotecontrollerindicator Remote Control Indicator SHORT Yes_No True
equipmentype ANSI Group SHORT Electric_Generation_ANSI_Group_Code True
tapsandpoles Number of Poles SHORT Electric_Generation_Pole_Count True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
optype Fuel Type SHORT Electric_Fuel_Type True
maximumpower Max Load (Watts) LONG Electric_Low_Voltage_Transformer_VA True
ratedpower Rated Load (Watts) LONG Electric_Low_Voltage_Transformer_VA True
powerfactor Power Factor DOUBLE Electric_Power_Factor_Range True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Low Voltage Generation: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Generation Unknown type of Low Voltage Generation. Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
281 Battery LV A low wattage Battery. Single terminal ['Asset Location', 'E:Bank', 'E:Generation', 'E:Generation - Distributed', 'E:Generation - Storage'] CONTAINER DO_NOT_SPLIT END_VERTEX
283 Generator LV A low voltage energy storage device frequently installed at residences. Single terminal ['Asset Location', 'E:Bank', 'E:Generation', 'E:Generation - Distributed'] CONTAINER DO_NOT_SPLIT END_VERTEX
284 Residential Photovoltaic Solar LV A low Wattage Photovoltaic solar. Single terminal ['Asset Location', 'E:Bank', 'E:Generation', 'E:Generation - Distributed'] CONTAINER DO_NOT_SPLIT END_VERTEX
285 Wind Turbine LV A low Wattage Windmill. Single terminal ['Asset Location', 'E:Bank', 'E:Generation', 'E:Generation - Distributed'] CONTAINER DO_NOT_SPLIT END_VERTEX
286 AC Wave LV A Ocean Wave Generation station providing power to the low voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Generation', 'E:Generation - Distributed'] CONTAINER DO_NOT_SPLIT END_VERTEX
428 Car Charger LV A Car Charge connected to the Low Voltage system that is also used to provide power to the low voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Generation', 'E:Generation - Distributed', 'E:Generation - Storage'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Lighting
A device used for lighting such as a streetlight or flood light.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Low_Voltage_Lighting False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
designtype Light Type SHORT Electric_Light_Housing_Type True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
remotecontrollerindicator Remote Control Indicator SHORT Yes_No True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
optype Bulb Type SHORT Electric_Low_Voltage_Street_Bulb_Type True
ratedpower Light Watts LONG True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Low Voltage Lighting: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Lighting A light of unknown type connected to the low voltage system Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
301 Floodlight LV A flood light connected to the low voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Lighting', 'E:Load'] CONTAINER DO_NOT_SPLIT END_VERTEX
302 Streetlight LV A street light connected to the low voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Lighting', 'E:Load'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Line Monitor and Relay
Line monitors are frequently used in conjunction with SCADA systems to monitor system conditions.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Low_Voltage_Line_Monitor_and_Relay False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts) LONG Electric_Voltage_Offset True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
remotecontrollerindicator Remote Control Indicator SHORT Yes_No True
equipmentype Type of Data SHORT Electric_RTU_Data_Type True
tripmode Single Phase Trip and Lockout SHORT Electric_Trip_Type True
peakload Max Reactive Power LONG Electric_Maximum_Voltage_Change True
offpeakload Min Reactive Power LONG Electric_Maximum_Voltage_Change True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
reversetrip Reverse Trip SHORT Yes_No True
p2sphaseshift Closing Phase Angle SHORT Electric_Phase_Whole_Degrees_Positive True
p2tphaseshift Master Angle SHORT Electric_Phase_Whole_Degrees_Positive True
timedelay Trip Time Delay SHORT Electric_Trip_Delay_Range True
tripcount Lockout Trip Count SHORT Electric_Trip_Count True
tapmaxchange Tap Maximum Change SHORT Electric_Short_Percent_Range True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG Electric_Winding_Ratio_Long True
powerfactor Power Factor DOUBLE Electric_Power_Factor_Range True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Low Voltage Line Monitor and Relay: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Line Monitor and Relay Unknown type of Low Voltage Line Monitor and Relay. Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
321 Fault Indicator LV A Fault indicator used in low voltage systems. Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
322 Load Monitor LV A load monitoring sensor used in low voltage systems. Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
323 Relay LV A relay used in low voltage systems. Relay ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
324 Instrument Transformer LV A specific type of transformer used in monitoring Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Motor
A motor, typically used in industrial operations.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Low_Voltage_Motor False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
designtype Motor Type SHORT Electric_Motor_Type True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
z0psimpedance Sequence Impedance -Z0ps DOUBLE Electric_Impedance_Range True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE Electric_Impedance_Range True
z1psimpedance Sequence Impedance -Z1ps DOUBLE Electric_Impedance_Range True
x0r0impedance Sequence Impedance -X0/R0pm DOUBLE Electric_Impedance_Range True
x1r1impedance Sequence Impedance -X1/R1 DOUBLE Electric_Impedance_Range True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE Electric_Impedance_Range True
primarygroundimpedance Ground Impedance Xg DOUBLE Electric_Impedance_Range True
gridsidecouplinginductance Primary Grounding Impedance Reactance DOUBLE Electric_Impedance_Range True
equipmentype ANSI Group SHORT Electric_Generation_ANSI_Group_Code True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
primarygroundimpedance2 Ground Impedance Rg DOUBLE Electric_Impedance_Range True
optype Assistance SHORT Electric_Motor_Assistance_Type True
ratedpower Rated Power LONG Electric_Low_Voltage_Transformer_VA True
maximumbuck Stator or Rotor Impedance DOUBLE True
powerfactor Power Factor DOUBLE Electric_Power_Factor_Range True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Low Voltage Motor: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Motor Low Voltage Motor Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
341 Single Phase Motor LV A low Voltage single phase motor. Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
342 Three Phase Motor LV A low Voltage three phase motor. Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
343 DC Motor LV A monitor that runs on Direct Current Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Network Protection
A device used to prevent energy from flowing in one direction. Typically used in mesh network systems.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Low_Voltage_Network_Protection False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT 0 Electric_Operating_Status True
normaloperatingstatus Normal Status SHORT 0 Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT 0 Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT 0 Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG Electric_Low_Voltage_Phase_Substitution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
remotecontrollerindicator Remote Control Indicator SHORT Yes_No True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
reversetrip Reverse Trip SHORT Yes_No True
timedelay Trip Time Delay SHORT Electric_Trip_Delay_Range True
tripcount Lockout Trip Count SHORT Electric_Trip_Count True
maximumpower Continuous Amps Rating LONG Electric_Low_Voltage_Fuse_Continuous_Amps True
minimumpower Interrupting Current LONG Electric_Low_Voltage_Fuse_Interrupting_Amps True
ratedpower Rated Current LONG Electric_Low_Voltage_Fuse_Continuous_Amps True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG Electric_Winding_Ratio_Long True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT Electric_Device_Operation True
operatingmechanism Equipment Field Operating Mechanism SHORT Electric_Device_OperatingMechanism True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Low Voltage Network Protection: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Network Protector Low Voltage Network Protection Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
361 Network Protector LV A low voltage device like a circuit breaker but also prevents energy flow in one direction. Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Protective', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Power Conversion
A device used to convert power type from AC to DC or DC to AC.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Low_Voltage_Power_Conversion False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
secondaryvoltagelinetoline Rated DC Voltage LONG Electric_DC_Low_Voltage_Nominal_Voltage True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
primarygroundimpedance Primary Ground Impedance (ohms) DOUBLE Electric_Device_Resistance_Range True
gridsidecouplinginductance Grid Side Coupling Inductance (ohms) DOUBLE Electric_Device_Resistance_Range True
remotecontrollerindicator Remote Control Indicator SHORT Yes_No True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maximumpower Max Load (Watts) LONG Electric_Low_Voltage_Transformer_VA True
ratedpower Rated Power LONG Electric_Low_Voltage_Transformer_VA True
powerfactor Power Factor DOUBLE Electric_Power_Factor_Range True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Low Voltage Power Conversion: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Power Conversion A device that converts power of unknown type in the low voltage system Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
381 Single Phase Inverter LV A device that converts input energy from DC to output energy of AC in the low voltage system Inverter ['Asset Location', 'E:Bank', 'E:Power Conversion'] CONTAINER DO_NOT_SPLIT END_VERTEX
382 Single Phase Rectifier LV A device that converts input energy from AC to output energy of DC in the low voltage system Rectifier ['Asset Location', 'E:Bank', 'E:Power Conversion'] CONTAINER DO_NOT_SPLIT END_VERTEX
383 Three Phase Inverter LV A device that converts input energy from DC to output energy of AC Three Phase in the low voltage system Inverter ['Asset Location', 'E:Bank', 'E:Power Conversion'] CONTAINER DO_NOT_SPLIT END_VERTEX
384 Three Phase Rectifier LV A device that converts input energy from three phase AC to output energy of DC in the low voltage system Rectifier ['Asset Location', 'E:Bank', 'E:Power Conversion'] CONTAINER DO_NOT_SPLIT END_VERTEX
386 Single Phase Bidirectional LV A power conversion device used to convert AC to DC or DC to AC in the low voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Power Conversion'] CONTAINER DO_NOT_SPLIT END_VERTEX
387 Three Phase Bidirectional LV A power conversion device used to convert three phase AC to DC or DC to AC three phase in the low voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Power Conversion'] CONTAINER DO_NOT_SPLIT END_VERTEX
390 Wave Trap LV Equipment used to prevent high frequency carrier signals of power line communication to unwanted destinations, low voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Power Conversion'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Power Factor Correcting
A device used in the correction of the power factor of AC energy.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Low_Voltage_Power_Factor_Correcting False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
designtype Series or Shunt SHORT Electric_Configuration_Type True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
gridsidecouplinginductance Grid Side Coupling Inductance (ohms) DOUBLE Electric_Device_Resistance_Range True
remotecontrollerindicator Remote Control Indicator SHORT Yes_No True
equipmentype Type SHORT Electric_Capacitory_Type True
tripmode Single Phase Trip and Lockout SHORT Yes_No True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
upperrange Upper Tempature Range - Operating DOUBLE Electric_Temperature_F True
upperrangemetric Upper Tempature Range - Operating (Metric) DOUBLE Electric_Temperature_C True
lowerrange Lower Tempature Range - Operating DOUBLE Electric_Temperature_F True
lowerrangemetric Lower Tempature Range - Operating (Metric) DOUBLE Electric_Temperature_C True
optype Control Type SHORT Electric_PF_Control_Type True
maximumpower Maximum kVAR LONG Electric_Low_Voltage_KVAR True
ratedpower Rated kVAR LONG Electric_Low_Voltage_KVAR True
starthour Start Hour of Operation SHORT Electric_Hour True
stophour Stop Hour of Operation SHORT Electric_Hour True
powerfactor Power Factor DOUBLE Electric_Power_Factor_Range True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Low Voltage Power Factor Correcting: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Power Factor Correcting A power factor correcting device of unknown type in the low voltage system Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
1 AC Overhead Single terminal ['Asset Location'] CONTAINER DO_NOT_SPLIT END_VERTEX
2 AC Underground Single terminal ['Asset Location'] CONTAINER DO_NOT_SPLIT END_VERTEX
3 AC Station Single terminal ['Asset Location', 'E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
4 AC Overhead Bank Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
5 AC Underground Bank Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
6 AC Station Bank Single terminal ['Asset Location', 'E:Bank', 'E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
11 DC Overhead Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
12 DC Underground Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
13 DC Station Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
401 Mobile Harmonic Filter LV A harmonic filter mounted on a trailer used in the low voltage system Single terminal ['Asset Location', 'E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
402 Mobile Reactor LV A reactor mounted on a trailer used in the low voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Reactive Power'] CONTAINER DO_NOT_SPLIT END_VERTEX
403 Overhead Capacitor LV A pole mounted capacitor used in the low voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Reactive Power'] CONTAINER DO_NOT_SPLIT END_VERTEX
404 Overhead Harmonic Filter LV A pole mounted harmonic filter used in the low voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Cable - Overhead'] CONTAINER DO_NOT_SPLIT END_VERTEX
405 Overhead Reactor LV A pole mounted reactor used in the low voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Reactive Power'] CONTAINER DO_NOT_SPLIT END_VERTEX
406 Pad Mounted Capacitor LV A pad mounted capacitor used in the low voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Reactive Power'] CONTAINER DO_NOT_SPLIT END_VERTEX
407 Pad Mounted Harmonic Filter LV A pad mounted harmonic filter used in the low voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
408 Pad Mounted Reactor LV A pad mounted reactor used in the low voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Reactive Power'] CONTAINER DO_NOT_SPLIT END_VERTEX
409 Station Capacitor LV A capacitor used in the low voltage system found in a station Single terminal ['Asset Location', 'E:Bank', 'E:Reactive Power', 'E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
410 Station Harmonic Filter LV A harmonic filter used in the low voltage system found in a station Single terminal ['Asset Location', 'E:Bank', 'E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
411 Station Reactor LV A reactor used in the low voltage system found in a station Single terminal ['Asset Location', 'E:Bank', 'E:Reactive Power', 'E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Service
A service location or load point used in the delivery of low voltage power, frequently thought of as a meter location.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Low_Voltage_Service False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
remotecontrollerindicator Remote Control Indicator SHORT Yes_No True
peakload Peak Load LONG Electric_Low_Voltage_Load_Watts True
offpeakload Off Peak Load LONG Electric_Low_Voltage_Load_Watts True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
ratedpower Rated Load (Watts) LONG Electric_Low_Voltage_Load_Watts True
noloadloss No Load Loss LONG Electric_Low_Voltage_Load_Loss True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG Electric_Winding_Ratio_Long True
powerfactor Power Factor DOUBLE Electric_Power_Factor_Range True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT Yes_No_Simple True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Low Voltage Service: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Service A unknown type of service metering point in the low voltage system Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
421 Single Phase Commercial LV A single phase metering device used for a commercial customer in the low voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Load', 'E:Load - Commercial', 'E:Load - Customer'] CONTAINER DO_NOT_SPLIT END_VERTEX
422 Single Phase Residential LV A single phase metering device used for a residential customer in the low voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Load', 'E:Load - Customer', 'E:Load - Residential'] CONTAINER DO_NOT_SPLIT END_VERTEX
423 Three Phase Commercial LV A three phase metering device used for a commercial customer in the low voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Load', 'E:Load - Commercial', 'E:Load - Customer'] CONTAINER DO_NOT_SPLIT END_VERTEX
424 Three Phase Residential LV A three phase metering device used for a residential customer in the low voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Load', 'E:Load - Customer', 'E:Load - Residential'] CONTAINER DO_NOT_SPLIT END_VERTEX
425 Unmetered Load LV A point representing load not associated with a customer in the low voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Load', 'E:Load - Customer'] CONTAINER DO_NOT_SPLIT END_VERTEX
426 DC Commercial LV A low voltage commercial service receiving Direct Current. Single terminal ['Asset Location', 'E:Bank', 'E:Load', 'E:Load - Commercial', 'E:Load - Customer'] CONTAINER DO_NOT_SPLIT END_VERTEX
427 Low Voltage Premise LV A service location of a customer connected to the low voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Load', 'E:Load - Customer', 'E:Load - Residential'] CONTAINER DO_NOT_SPLIT END_VERTEX
428 Car Charger LV A Car Charge connected to the Low Voltage system Single terminal ['Asset Location', 'E:Bank', 'E:Load', 'E:Load - Customer', 'E:Load - Residential'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Switch
A switch used to control the flow of energy.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Low_Voltage_Switch False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT 0 Electric_Operating_Status True
normaloperatingstatus Normal Status SHORT 0 Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT 0 Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT 0 Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG Electric_Low_Voltage_Phase_Substitution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
manufacturer Manufacturer SHORT Electric_Device_Switch_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
remotecontrollerindicator Remote Control Indicator SHORT Yes_No True
tripmode Single Phase Trip and Lockout SHORT Electric_Trip_Type True
directional Reversible SHORT Yes_No True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
reversetrip Reverse Trip SHORT Yes_No True
timedelay Trip Time Delay SHORT Electric_Trip_Delay_Range True
tripcount Lockout Trip Count SHORT Electric_Trip_Count True
optype Operational Type SHORT Electric_Switch_Breaking_Medium True
maximumpower Continuous Amps Rating LONG Electric_Low_Voltage_Switch_Interrupting_Amps True
minimumpower Interrupting Current LONG Electric_Low_Voltage_Switch_Interrupting_Amps True
ratedpower Rated Current LONG Electric_Low_Voltage_Switch_Continuous_Amps True
inparallel inparallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT Electric_Device_Operation True
operatingmechanism Equipment Field Operating Mechanism SHORT Electric_Device_OperatingMechanism True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
isriser Is Riser SHORT Yes_No_Simple True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Low Voltage Switch: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Switch A unknown switch type used in the low voltage system Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
1 AC Overhead Single terminal ['Asset Location', 'E:Switch'] CONTAINER DO_NOT_SPLIT END_VERTEX
2 AC Underground Single terminal ['Asset Location', 'E:Switch'] CONTAINER DO_NOT_SPLIT END_VERTEX
3 AC Station Single terminal ['Asset Location', 'E:Station', 'E:Switch'] CONTAINER DO_NOT_SPLIT END_VERTEX
4 AC Overhead Bank Simple Switch ['Asset Location', 'E:Bank', 'E:Switch'] CONTAINER DO_NOT_SPLIT END_VERTEX
5 AC Underground Bank Simple Switch ['Asset Location', 'E:Bank', 'E:Switch'] CONTAINER DO_NOT_SPLIT END_VERTEX
6 AC Station Bank Circuit Breaker ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch'] CONTAINER DO_NOT_SPLIT END_VERTEX
11 DC Overhead Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
12 DC Underground Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
13 DC Station Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
14 DC Overhead Bank Simple Switch ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
15 DC Underground Bank Simple Switch ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
16 DC Station Bank Circuit Breaker ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
431 AC Station Disconnect LV A station located disconnecting switch used in the low voltage AC system Circuit Breaker ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
432 AC Station Load Break LV A station located load breaking switch used in the low voltage AC system Circuit Breaker ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
433 AC Station Load Break Disconnect LV A station located load breaking or disconnecting switch used in the low voltage AC system Circuit Breaker ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
434 AC Station Disconnect LV - Controller A station located disconnecting switch used in the low voltage AC system that can also be used as a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
435 AC Station Load Break LV - Controller A station located load breaking switch used in the low voltage AC system that can also be used as a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
436 AC Station Load Break Disconnect LV - Controller A station located load breaking or disconnecting switch used in the low voltage AC system that can also be used as a subnetwork controller Circuit Breaker Directional ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
441 Overhead AC Load Break LV An aerial mounted load breaking switch in the low voltage AC system Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
442 Overhead AC Disconnect LV An aerial mounted disconnecting switch in the low voltage AC system Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
443 Overhead DC Load Break LV An aerial mounted load breaking switch in the low voltage DC system Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
444 Overhead DC Disconnect LV An aerial mounted disconnecting switch in the low voltage DC system Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
445 Underground AC Load Break LV A load breaking switch in the underground portion of the low voltage AC system Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
446 Underground AC Disconnect LV A disconnecting switch in the underground portion of the low voltage AC system Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
447 Underground DC Load Break LV A load breaking switch in the underground portion of the low voltage DC system Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
448 Underground DC Disconnect LV A disconnecting switch in the underground portion of the low voltage DC system Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
449 Indoor AC Load Break LV A load breaking switch located in an indoor location, such as a building or vault, in the low voltage AC system Simple Switch ['Asset Location', 'E:Bank', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
450 Indoor AC Disconnect LV A disconnecting switch located in an indoor location, such as a building or vault, in the low voltage AC system Simple Switch ['Asset Location', 'E:Bank', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
451 Indoor DC Load Break LV A load breaking switch located in an indoor location, such as a building or vault, in the low voltage DC system Simple Switch ['Asset Location', 'E:Bank', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
452 Indoor DC Disconnect LV A disconnecting switch located in an indoor location, such as a building or vault, in the low voltage DC system Simple Switch ['Asset Location', 'E:Bank', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
453 Source Selectable Switch LV A switch capable of having two sources, where only one source can be selected at a time, in the low voltage AC system V-Blade Switch ['Asset Location', 'E:Bank', 'E:Switch', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
454 Overhead Jumper LV An aerial mounted jumper in the low voltage system Simple Switch ['Asset Location', 'E:Bank', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
456 DC Station LV A station located switch used in the low voltage DC system Circuit Breaker ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
457 AC Station Bypass LV A mechanical switch that can change between three connections used in the low voltage AC system Circuit Breaker ['Asset Location', 'E:Bank', 'E:Station', 'E:Switch', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
458 AC Recloser LV A mechanical self closing switch used in the low voltage AC system Dual Terminal ['Asset Location', 'E:Bank', 'E:Fault Breaking', 'E:Switch', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Transformer
Transformer devices represent a single electrical transformer. These devices can be by phase or polyphase.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Low_Voltage_Transformer False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Primary Nominal Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Primary Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondaryvoltagelinetoline Secondary Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondarygrounding Secondary Winding Grounding SHORT Electric_Ground_Configuration_Transformer_Regulator True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
tertiarygrounding Tertiary Winding Grounding SHORT Electric_Ground_Configuration_Transformer_Regulator True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE Electric_Tap_Maximum_Change True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE Electric_Load_Tap_Bandwidth True
maximumboost Maximum Voltage Boost DOUBLE Electric_Buck_Boost_Rate True
z0psimpedance Sequence Impedance -Z0ps DOUBLE Electric_Impedance_Range True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE Electric_Impedance_Range True
z1psimpedance Sequence Impedance -Z1ps DOUBLE Electric_Impedance_Range True
x0r0impedance Sequence Impedance -X0/R0pm DOUBLE Electric_Impedance_Range True
x1r1impedance Sequence Impedance -X1/R1 DOUBLE Electric_Impedance_Range True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE Electric_Impedance_Range True
primarygroundimpedance Primary Ground Impedance Rg (ohms) DOUBLE Electric_Impedance_Range True
gridsidecouplinginductance Grid Side Coupling Inductance (ohms) DOUBLE Electric_Impedance_Range True
equipmentype Insulation Type SHORT Electric_XFR_Type True
tapsandpoles Number of Taps SHORT Electric_Taps_Range True
peakload Peak Load LONG Electric_Medium_Voltage_Load_Watts True
offpeakload Off Peak Load LONG Electric_Low_Voltage_Load_Watts True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
primarygroundimpedance2 Primary Ground Impedance Xg (ohms) DOUBLE Electric_Impedance_Range True
p2sphaseshift Primary to Secondary Phase Shift SHORT Electric_Phase_Shift True
p2tphaseshift Primary to Tertiary Phase Shift SHORT Electric_Phase_Shift True
optype Operational Type SHORT True
maximumpower Maximum kVA LONG Electric_Low_Voltage_Transformer_VA True
ratedpower Rated kVA LONG Electric_Low_Voltage_Transformer_VA True
loadtapchangepercent Load Tap Change (%) SHORT Electric_Tap_Change_Percent True
noloadloss No Load Loss LONG Electric_Low_Voltage_Load_Loss True
secondarygroundimpedance Secondary Ground Impedance Rg DOUBLE Electric_Impedance_Range True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG Electric_Winding_Ratio_Long True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE Electric_Impedance_Range True
powerfactor Power Factor DOUBLE Electric_Power_Factor_Range True
coolingtype Cooling Type SHORT Electric_Transformer_Cooling True
inparallel inparallel SHORT Yes_No True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
primarytosecondaryvectorgroup Primary to Secondary Winding Vector Group SHORT Electric_Winding_Vector_Group True
primarytotertiaryvectorygroup Primary to Tertiary Winding Vector Group SHORT Electric_Winding_Vector_Group True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Low Voltage Transformer: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Transformer A transformer of unknown type used in the low voltage system Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
461 Single Phase - LV->LV A single phase transformer used to convert power from low voltage to a different low voltage Two Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
462 Three Phase - LV->LV A low voltage three phase transformer. Two Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
463 Three Winding - LV->LV-LV A three winding Low Voltage transformer Three Winding ['Asset Location', 'E:Bank', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Wire Connector
A non-operable device used to connect and disconnect electrical wires
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_Device_Low_Voltage_Wire_Connector False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT 0 Electric_Operating_Status True
normaloperatingstatus Normal Status SHORT 0 Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT 0 Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT 0 Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG Electric_Low_Voltage_Phase_Substitution True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
equipmentype Group/Type SHORT True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT True
Subtype: Low Voltage Wire Connector: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Wire Connector Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
861 Ring Terminal LV Single terminal ['Asset Location', 'E:Bank', 'E:Switch - Circuit Breaker'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Regulator
Voltage Regulator devices represent a device that is used in the regulation of voltage on the electric line.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Device_Low_Voltage_Regulator False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE Electric_Tap_Maximum_Change True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE Electric_Load_Tap_Bandwidth True
maximumboost Maximum Voltage Boost DOUBLE Electric_Buck_Boost_Rate True
z0psimpedance Sequence Impedance -Z0ps DOUBLE Electric_Impedance_Range True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE Electric_Impedance_Range True
z1psimpedance Sequence Impedance -Z1ps DOUBLE Electric_Impedance_Range True
x0r0impedance Sequence Impedance -X0/R0pm DOUBLE Electric_Impedance_Range True
x1r1impedance Sequence Impedance -X1/R1 DOUBLE Electric_Impedance_Range True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE Electric_Impedance_Range True
primarygroundimpedance Primary Ground Impedance Rg (ohms) DOUBLE Electric_Impedance_Range True
gridsidecouplinginductance Grid Side Coupling Inductance (ohms) DOUBLE Electric_Impedance_Range True
remotecontrollerindicator Remote Control Indicator SHORT Electric_Remoted_Controlled True
equipmentype Insulation Type SHORT Electric_XFR_Type True
tapsandpoles Number of Taps SHORT Electric_Taps_Range True
directional Bi Directional SHORT Yes_No True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
primarygroundimpedance2 Primary Ground Impedance Xg (ohms) DOUBLE Electric_Impedance_Range True
reversetrip Reverse Trip SHORT Yes_No True
timedelay Trip Time Delay SHORT Electric_Trip_Delay_Range True
tripcount Lockout Trip Count SHORT Electric_Trip_Count True
tapmaxchange Tap Maximum Change SHORT Electric_Taps_Range True
optype Operational Type SHORT Electric_Regulator_Operation_Type True
maximumpower Maximum kVA LONG Electric_Low_Voltage_Regulator_VA True
ratedpower Rated kVA LONG Electric_Low_Voltage_Regulator_VA True
loadtapchangepercent Load Tap Change (%) SHORT Electric_Tap_Change_Percent True
noloadloss No Load Loss LONG Electric_Medium_Voltage_Load_Loss True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG Electric_Winding_Ratio_Long True
maximumbuck Maximum Buck DOUBLE Electric_Regulator_Maximum_Buck_Boost True
buckbandwidth Buck Bandwidth SHORT Electric_Voltage_Bandwidth True
loadtapchangerupperbandwidth Load Tap Changer Upper Bandwidth DOUBLE Electric_Load_Tap_Bandwidth True
loadtapchangerminimumchange Load Tap Changer Minimum Change DOUBLE Electric_Load_Tap_Bandwidth True
starthour Start Hour of Operation SHORT Electric_Hour True
stophour Stop Hour of Operation SHORT Electric_Hour True
coolingtype Cooling Type SHORT Electric_Transformer_Cooling True
inparallel inparallel SHORT Yes_No True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
primarytosecondaryvectorgroup Primary to Secondary Winding Vector Group SHORT Electric_Winding_Vector_Group True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT Yes_No_Simple True
Subtype: Low Voltage Regulator: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Regulator A voltage regulating device used in the low voltage system Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
141 AC Single Phase LV An Single Phase Voltage Regulator used in Low Voltage AC system Single terminal ['Asset Location', 'E:Bank', 'E:Voltage Regulation'] CONTAINER DO_NOT_SPLIT END_VERTEX
142 AC Three Phase LV A three phase voltage regulator used in the low voltage AC system Single terminal ['Asset Location', 'E:Bank', 'E:Voltage Regulation'] CONTAINER DO_NOT_SPLIT END_VERTEX
143 DC Regulator LV An Voltage Regulator used in low Voltage DC system Single terminal ['Asset Location', 'E:Bank', 'E:Voltage Regulation'] CONTAINER DO_NOT_SPLIT END_VERTEX
144 Network Load Balancer LV A device used to balance load between phases in the low voltage system Circuit Breaker ['Asset Location', 'E:Bank', 'E:Voltage Regulation'] CONTAINER DO_NOT_SPLIT END_VERTEX
145 Frequency Converter LV A device that converts a current with one frequency to a current with another frequency in the low voltage AC system Voltage Regulator ['Asset Location', 'E:Bank', 'E:Voltage Regulation'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Transformer Winding
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_Device_Low_Voltage_Transformer_Winding False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal Configuration TEXT (128) Default False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname Subnetwork name TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT True
normaloperatingstatus Normal Operating Status SHORT True
winteroperatingstatus Winter Operating Status SHORT True
summeroperatingstatus Summer Operating Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG Electric_Low_Voltage_Phase_Substitution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT True
designtype Design Type SHORT True
manufacturer Manufacturer SHORT True
secondaryvoltagelinetoline Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
secondaryvoltagelinetoground Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
secondarygrounding Grounding SHORT Electric_Ground_Configuration True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance Sequence Impedance -X0 DOUBLE True
x1r1impedance Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
directional Bi Directional/Reversible SHORT True
peakload Peak Load LONG True
offpeakload Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
upperrange Upper Tempature Range - Operating DOUBLE True
upperrangemetric Upper Tempature Range - Operating (Metric) DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
lowerrangemetric Lower Tempature Range - Operating (Metric) DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT Electric_Phase_Shift True
p2tphaseshift Primary to Tertiary Phase Shift SHORT Electric_Phase_Shift True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Tap Maximum Change SHORT True
optype Operational Type SHORT True
maximumpower Maximum Power LONG True
minimumpower Min Power LONG True
ratedpower Rated Power LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user created_user TEXT (255) True
created_date created_date DATE True
last_edited_user last_edited_user TEXT (255) True
last_edited_date last_edited_date DATE True
primarytosecondaryvectorgroup Primary to Secondary Winding Vector Group SHORT True
primarytotertiaryvectorygroup Primary to Tertiary Winding Vector Group SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT True
operatingmechanism Equipment Field Operating Mechanism SHORT True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT True
hasarrester Has Arrester SHORT True
Subtype: Low Voltage Transformer Winding: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Transformer Winding Single terminal ['E:Bank'] CONTAINER DO_NOT_SPLIT END_VERTEX
874 AC Transformer Winding LV Transformer Winding ['Asset Location', 'E:Bank', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX
875 DC Transformer Winding LV Transformer Winding ['Asset Location', 'E:Bank', 'Subnetwork Controller'] CONTAINER DO_NOT_SPLIT END_VERTEX

ElectricJunction

The Junction class represents locations where lines connect to lines or lines connect to devices. A key use for junction features is to allow devices or lines to connect to another line at an intermediate vertex. You can think of a junction as 'glue point' at key places to connect all the features of a utility network. Junctions can be contained within assemblies.
Class Details
DatasetType ShapeType Alias Has Attachment
FEATURE_CLASS SIMPLE ElectricJunction True
Fields
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG 0 False
assettype Asset type SHORT 0 False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname Subnetwork name TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Attribution_All False
phasechange Phase Change SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT 0 Electric_Phase_Attribution_All False
phasesenergized Phases Energized SHORT 0 Electric_Phase_Attribution_All True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status_Combined False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
manufacturer Equipment Maker SHORT Electric_Equipment_Manufacturer True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
ownedby Owned By SHORT 1 Asset_Owner True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
isriser Is Riser SHORT Yes_No_Simple True
sectionid Section ID TEXT (2000) True
hasarrester Has Arrester SHORT True
isvalidloop Participates in a valid loop SHORT Yes_No_Simple True
withstandrating BIL or Withstand Voltage Rating LONG Electric_BIL_Combined True
validationstatus Validation status SHORT 6 True
Subtypes
Code Name Description
0 Unknown The Unknown asset group in the ElectricJunction feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it.
20 Ground Attachment A junction feature used to Connect Ground lines
1 High Voltage Attachment Points on High voltage lines where structures would attach.
2 High Voltage Connection Point Points where electric cables connect, but no device exists, like a Tap.
3 High Voltage Line End Ends of cables, both overhead and underground. In overhead, these will often the location of a "Dead End".
7 Medium Voltage Attachment Points on Medium voltage lines where structures would attach.
8 Medium Voltage Connection Point Points where electric cables connect, but no device exists, like a Tap.
9 Medium Voltage Line End Ends of cables, both overhead and underground. In overhead, these will often the location of a "Dead End".
4 Low Voltage Attachment Points on Low voltage lines where structures would attach.
5 Low Voltage Connection Point Points where electric cables connect, but no device exists, like a Tap.
6 Low Voltage Line End Ends of cables, both overhead and underground. In overhead, these will often the location of a "Dead End".
Subtype: Unknown
The Unknown asset group in the ElectricJunction feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 UtilityNetwork_5_UnknownAssetType False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Attribution_All False
phasechange Phase Change SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT 0 Electric_Phase_Attribution_All False
phasesenergized Phases Energized SHORT 0 Electric_Phase_Attribution_All True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
ownedby Owned By SHORT 1 Asset_Owner True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
hasarrester Has Arrester SHORT True
validationstatus Validation status SHORT 6 True
Subtype: Unknown: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Ground Attachment
A junction feature used to Connect Ground lines
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_Junction_Ground_Attachment False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
manufacturer Equipment Maker SHORT Electric_Equipment_Manufacturer True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
ownedby Owned By SHORT 1 Asset_Owner True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
isriser Is Riser SHORT Yes_No_Simple True
sectionid Section ID TEXT (2000) True
hasarrester Has Arrester SHORT True
validationstatus Validation status SHORT 6 True
Subtype: Ground Attachment: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A location where grounds are attached, but the type of connection is unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
201 Ground Joint A location where two or more ground lines are connected Single terminal ['E:Ground'] NONE DO_NOT_SPLIT END_VERTEX
203 Neutral Joint A location where two or more neutrals are connected Single terminal ['E:Ground'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Attachment
Points on High voltage lines where structures would attach.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Junction_High_Voltage_Attachment False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT 3 Electric_High_Voltage_Phases_Constructed True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
ownedby Owned By SHORT 1 Asset_Owner True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT Construction_Status False
isriser Is Riser SHORT Yes_No_Simple True
sectionid Section ID TEXT (2000) True
hasarrester Has Arrester SHORT Yes_No_Simple True
validationstatus Validation status SHORT 6 True
Subtype: High Voltage Attachment: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A connection point used for associations from unknown high voltage lines to supporting structures Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
1 AC Overhead HV A connection point used for associations from aerial high voltage ac lines to poles and towers. Single terminal ['E:Cable - Overhead'] CONTAINER DO_NOT_SPLIT END_VERTEX
2 AC Underground HV A connection point used for associations from underground high voltage ac lines to supporting structures Single terminal ['E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
3 DC Overhead HV A connection point used for associations from aerial high voltage dc lines to poles and towers. Single terminal ['E:Cable - Overhead'] CONTAINER DO_NOT_SPLIT END_VERTEX
4 DC Underground HV A connection point used for associations from underground high voltage dc lines to supporting structures Single terminal ['E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
5 AC Riser HV A connection point used for associations from aerial high voltage ac lines to poles and towers and to transition from aerial to underground lines Single terminal ['E:Cable - Underground'] NONE DO_NOT_SPLIT END_VERTEX
6 DC Riser HV A connection point used for associations from aerial high voltage dc lines to poles and towers and to transition from aerial to underground lines Single terminal ['E:Cable - Underground'] NONE DO_NOT_SPLIT END_VERTEX
7 AC Submersible HV A connection point used for associations from submersible high voltage ac lines to supporting structures Single terminal ['E:Cable - Underground'] NONE DO_NOT_SPLIT END_VERTEX
8 DC Submersible HV A connection point used for associations from submersible high voltage dc lines to supporting structures Single terminal ['E:Cable - Underground'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Connection Point
Points where electric cables connect, but no device exists, like a Tap.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Junction_High_Voltage_Connection_Point False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT 3 Electric_High_Voltage_Phases_Constructed True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
ownedby Owned By SHORT 1 Asset_Owner True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
isriser Is Riser SHORT Yes_No_Simple True
sectionid Section ID TEXT (2000) True
hasarrester Has Arrester SHORT Yes_No_Simple True
validationstatus Validation status SHORT 6 True
Subtype: High Voltage Connection Point: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown High Voltage Connection Point of unknown type Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
21 AC Tap HV A high voltage overhead AC Tap for connecting lines at mid line. Single terminal ['Subnetwork Tap'] CONTAINER DO_NOT_SPLIT END_VERTEX
23 DC Tap HV A high voltage overhead DC Tap for connecting lines at mid line. Single terminal ['Subnetwork Tap'] CONTAINER DO_NOT_SPLIT END_VERTEX
24 AC Busbar Tap HV A high voltage AC busbar tap used for connecting lines at mid line. Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
25 DC Busbar Tap HV A high voltage DC busbar tap used for connecting lines at mid line. Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
36 AC Bond Connection HV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
37 DC Bond Connection HV Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
45 AC Busbar Connection HV Single terminal ['Attribute Substitution'] CONTAINER DO_NOT_SPLIT END_VERTEX
46 DC Busbar Connection HV Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Line End
Ends of cables, both overhead and underground. In overhead, these will often the location of a "Dead End".
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Junction_High_Voltage_Line_End False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT 3 Electric_High_Voltage_Phases_Constructed True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
ownedby Owned By SHORT 1 Asset_Owner True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
isriser Is Riser SHORT Yes_No_Simple True
sectionid Section ID TEXT (2000) True
hasarrester Has Arrester SHORT Yes_No_Simple True
validationstatus Validation status SHORT 6 True
Subtype: High Voltage Line End: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A location where line ends can allow connectivity to another cable or equipment in the high voltage AC system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
20 AC Overhead Splice HV Single terminal ['E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
22 DC Overhead Splice HV Single terminal ['E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
40 AC Service Connection HV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
41 AC Overhead Line End HV A location where a cable is cut or split and can allow connectivity to another cable or equipment in the high voltage AC system Single terminal ['E:Cable - Overhead', 'E:Overhead - Dead End'] CONTAINER DO_NOT_SPLIT END_VERTEX
42 DC Overhead Line End HV A location where a cable is cut or split and can allow connectivity to another cable or equipment in the high voltage AC system Single terminal ['E:Cable - Overhead', 'E:Overhead - Dead End'] CONTAINER DO_NOT_SPLIT END_VERTEX
43 AC Underground Terminator HV Single terminal ['E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
44 DC Underground Terminator HV Single terminal ['E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
47 AC SLTE HV An AC Submarine Line Terminating Equipment used in High Voltage Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
48 DC SLTE HV A Submarine Line Terminating location used for DC power in the high voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
49 Insulating Cap HV A cap used to project underground cable found in the high voltage system Single terminal ['E:Cable - Underground'] NONE DO_NOT_SPLIT END_VERTEX
51 AC Straight Joint HV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
52 DC Straight Joint HV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
53 AC T Joint HV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
54 DC T Joint HV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Attachment
Points on Medium voltage lines where structures would attach.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Junction_Medium_Voltage_Attachment False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT 3 Electric_Medium_Low_Voltage_Number_Of_Phases True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
manufacturer Equipment Maker SHORT Electric_Equipment_Manufacturer True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
ownedby Owned By SHORT 1 Asset_Owner True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
isriser Is Riser SHORT Yes_No_Simple True
sectionid Section ID TEXT (2000) True
hasarrester Has Arrester SHORT Yes_No_Simple True
validationstatus Validation status SHORT 6 True
Subtype: Medium Voltage Attachment: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A connection point used for associations from unknown medium voltage lines to supporting structures Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
60 Overhead MV A connection point used for associations from aerial medium voltage lines to poles and towers. Single terminal ['E:Cable - Overhead'] CONTAINER DO_NOT_SPLIT END_VERTEX
61 Underground MV A connection point used for associations from underground medium voltage lines to supporting structures Single terminal ['E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
62 Riser MV A connection point used for associations from aerial medium voltage lines to poles and towers and to transition from aerial to underground lines Single terminal ['E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
63 Submersible MV A connection point used for associations from submersible medium voltage lines to supporting structures Single terminal ['E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Connection Point
Points where electric cables connect, but no device exists, like a Tap.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Junction_Medium_Voltage_Connection_Point False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG Electric_Medium_Voltage_Phase_Substitution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT 3 Electric_Medium_Low_Voltage_Number_Of_Phases True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
manufacturer Equipment Maker SHORT Electric_Equipment_Manufacturer True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
ownedby Owned By SHORT 1 Asset_Owner True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
isriser Is Riser SHORT Yes_No_Simple True
sectionid Section ID TEXT (2000) True
hasarrester Has Arrester SHORT Yes_No_Simple True
validationstatus Validation status SHORT 6 True
Subtype: Medium Voltage Connection Point: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Medium Voltage Connection Point of unknown type Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
80 Busbar Tap MV A medium voltage busbar tap used for connecting lines at mid line. Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
82 Overhead Tap MV A medium voltage overhead tap used for connecting lines at mid line. Single terminal ['Attribute Substitution', 'E:Cable - Overhead', 'Subnetwork Tap'] CONTAINER DO_NOT_SPLIT END_VERTEX
85 Neutral Connection MV A medium voltage connection point that allows connectivity between a phased conductor and the neutral line. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
87 Underground Phase Connector MV A medium voltage point used to connect a single phase. Single terminal ['E:Cable - Underground', 'Subnetwork Tap'] NONE DO_NOT_SPLIT END_VERTEX
96 Bond Connection MV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
160 Busbar Connection MV Single terminal ['Attribute Substitution'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Line End
Ends of cables, both overhead and underground. In overhead, these will often the location of a "Dead End".
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Junction_Medium_Voltage_Line_End False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG Electric_Medium_Voltage_Phase_Substitution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT 3 Electric_Medium_Low_Voltage_Number_Of_Phases True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
manufacturer Equipment Maker SHORT Electric_Equipment_Manufacturer True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
ownedby Owned By SHORT 1 Asset_Owner True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
isriser Is Riser SHORT Yes_No_Simple True
sectionid Section ID TEXT (2000) True
hasarrester Has Arrester SHORT Yes_No_Simple True
validationstatus Validation status SHORT 6 True
Subtype: Medium Voltage Line End: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A location where line ends can allow connectivity to another cable or equipment in the medium voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
81 Overhead Splice MV Single terminal ['E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
84 Underground Splice MV Single terminal ['E:Cable - Underground'] NONE DO_NOT_SPLIT END_VERTEX
161 Overhead Line End MV A medium voltage line end point used on overhead lines, like a dead-end. Single terminal ['E:Cable - Overhead', 'E:Cable - Underground', 'E:Overhead - Dead End'] CONTAINER DO_NOT_SPLIT END_VERTEX
162 Underground Terminator MV A medium voltage underground cable terminator like a strain. Single terminal ['Attribute Substitution', 'E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
163 Overhead Wire Change MV A medium voltage location where the number of phases change and not all wires are cut at this point. Single terminal ['Attribute Substitution', 'E:Cable - Overhead'] CONTAINER DO_NOT_SPLIT END_VERTEX
164 Underground Wire Change MV A medium voltage location where the number of phases change and not all wires are cut at this point used in underground for data migration. Single terminal ['Attribute Substitution', 'E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
167 SLTE MV A Submarine Line Terminating location Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
168 Sealed Short-Circuited Terminator MV A device used to seal the end of an underground cable to prevent moister from entering the cable Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
169 Service Connection MV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
170 Insulating Cap MV A cap used to project underground cable found in the medium voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
171 Straight Joint MV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
172 T Joint MV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
173 Open Point MV Single terminal ['E:Cable - Overhead', 'E:Cable - Underground', 'E:Open Point', 'E:Overhead - Dead End'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Attachment
Points on Low voltage lines where structures would attach.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Junction_Low_Voltage_Attachment False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
manufacturer Equipment Maker SHORT Electric_Equipment_Manufacturer True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
ownedby Owned By SHORT 1 Asset_Owner True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
isriser Is Riser SHORT Yes_No_Simple True
sectionid Section ID TEXT (2000) True
hasarrester Has Arrester SHORT Yes_No_Simple True
validationstatus Validation status SHORT 6 True
Subtype: Low Voltage Attachment: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A connection point used for associations from unknown low voltage lines to supporting structures Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
101 AC Overhead LV A connection point used for associations from aerial high voltage ac lines to poles and towers. Single terminal ['E:Cable - Overhead'] CONTAINER DO_NOT_SPLIT END_VERTEX
102 AC Underground LV A connection point used for associations from underground low voltage ac lines to supporting structures Single terminal ['E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
103 DC Overhead LV A connection point used for associations from aerial high voltage dc lines to poles and towers. Single terminal ['E:Cable - Overhead'] CONTAINER DO_NOT_SPLIT END_VERTEX
104 DC Underground LV A connection point used for associations from underground low voltage dc lines to supporting structures Single terminal ['E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
105 AC Riser LV A connection point used for associations from aerial high voltage ac lines to poles and towers and to transition from aerial to underground lines Single terminal ['E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
106 DC Riser LV A connection point used for associations from aerial high voltage dc lines to poles and towers and to transition from aerial to underground lines Single terminal ['E:Cable - Underground'] NONE DO_NOT_SPLIT END_VERTEX
107 AC Submersible LV A connection point used for associations from submersible low voltage ac lines to supporting structures Single terminal ['E:Cable - Underground'] NONE DO_NOT_SPLIT END_VERTEX
108 DC Submersible LV A connection point used for associations from submersible low voltage dc lines to supporting structures Single terminal ['E:Cable - Underground'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Connection Point
Points where electric cables connect, but no device exists, like a Tap.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Junction_Low_Voltage_Connection_Point False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
manufacturer Equipment Maker SHORT Electric_Equipment_Manufacturer True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
ownedby Owned By SHORT 1 Asset_Owner True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
isriser Is Riser SHORT Yes_No_Simple True
sectionid Section ID TEXT (2000) True
hasarrester Has Arrester SHORT Yes_No_Simple True
validationstatus Validation status SHORT 6 True
Subtype: Low Voltage Connection Point: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Low Voltage Connection Point of unknown type Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
124 AC Busbar Tap LV Low Voltage Connection Point for AC Busbar Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
125 DC Busbar Tap LV Low Voltage Connection Point for DC Busbar Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
128 AC Overhead Tap LV A low voltage overhead tap used for connecting AC lines at mid line. Single terminal ['Attribute Substitution', 'E:Cable - Overhead', 'Subnetwork Tap'] CONTAINER DO_NOT_SPLIT END_VERTEX
129 DC Overhead Tap LV A low voltage overhead tap used for connecting DC lines at mid line. Single terminal ['E:Cable - Overhead', 'Subnetwork Tap'] CONTAINER DO_NOT_SPLIT END_VERTEX
134 AC Underground Phase Connector LV A medium voltage point used to connect AC Cable. Single terminal ['E:Cable - Underground', 'Subnetwork Tap'] NONE DO_NOT_SPLIT END_VERTEX
135 DC Underground Phase Connector LV A medium voltage point used to connect DC Cable. Single terminal ['E:Cable - Underground', 'Subnetwork Tap'] NONE DO_NOT_SPLIT END_VERTEX
136 AC Bond Connection LV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
137 DC Bond Connection LV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
145 AC Busbar Connection LV Single terminal ['Attribute Substitution'] CONTAINER DO_NOT_SPLIT END_VERTEX
146 DC Busbar Connection LV Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Line End
Ends of cables, both overhead and underground. In overhead, these will often the location of a "Dead End".
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Junction_Low_Voltage_Line_End False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
manufacturer Equipment Maker SHORT Electric_Equipment_Manufacturer True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
ownedby Owned By SHORT 1 Asset_Owner True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
isriser Is Riser SHORT Yes_No_Simple True
sectionid Section ID TEXT (2000) True
hasarrester Has Arrester SHORT Yes_No_Simple True
validationstatus Validation status SHORT 6 True
Subtype: Low Voltage Line End: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A location where line ends can allow connectivity to another cable or equipment in the low voltage AC system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
120 AC Overhead Splice LV Single terminal ['E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
121 DC Overhead Splice LV Single terminal ['E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
126 AC Underground Splice LV Single terminal ['E:Cable - Underground'] NONE DO_NOT_SPLIT END_VERTEX
127 DC Underground Splice LV Single terminal ['E:Cable - Underground'] NONE DO_NOT_SPLIT END_VERTEX
140 AC Service Connection LV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
141 AC Overhead Line End LV A location where a cable is cut or split and can allow connectivity to another cable or equipment in the low voltage AC system Single terminal ['E:Cable - Overhead', 'E:Overhead - Dead End'] CONTAINER DO_NOT_SPLIT END_VERTEX
142 DC Overhead Line End LV A location where a cable is cut or split and can allow connectivity to another cable or equipment in the low voltage AC system Single terminal ['E:Cable - Overhead', 'E:Overhead - Dead End'] CONTAINER DO_NOT_SPLIT END_VERTEX
143 AC Underground Terminator LV A low voltage point found at the end of an AC Underground Cable Single terminal ['E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
144 DC Underground Terminator LV A low voltage point found at the end of an DC Underground Cable. Single terminal ['E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
147 AC SLTE LV An AC Submarine Line Terminating Equipment used in Low Voltage Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
148 DC SLTE LV A Submarine Line Terminating location used for DC power in the low voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
149 AC Overhead Wire Change LV A location where a change in phases in a overhead line occur Single terminal ['E:Cable - Overhead'] CONTAINER DO_NOT_SPLIT END_VERTEX
150 Insulating Cap LV A cap used to project underground cable found in the low voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
151 AC Straight Joint LV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
152 DC Straight Joint LV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
153 AC T Joint LV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
154 DC T Joint LV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
155 AC Open Point LV Single terminal ['E:Cable - Overhead', 'E:Open Point', 'E:Overhead - Dead End'] CONTAINER DO_NOT_SPLIT END_VERTEX
156 DC Open Point LV Single terminal ['E:Cable - Overhead', 'E:Open Point', 'E:Overhead - Dead End'] CONTAINER DO_NOT_SPLIT END_VERTEX

ElectricLine

The Line feature class represents linear features. These are the lines which deliver your utility resource. Lines can be connected to other lines, junctions, and devices. Lines can be contained within assemblies.
Class Details
DatasetType ShapeType Alias Has Attachment
FEATURE_CLASS SIMPLE ElectricLine True
Fields
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG 0 False
assettype Asset type SHORT 0 False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
fromdeviceterminal From device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
todeviceterminal To device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname Subnetwork name TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Attribution_All False
phasechange Phase Change SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT 0 Electric_Phase_Attribution_All False
phasesenergized Phases Energized SHORT 0 Electric_Phase_Attribution_All True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT True
maxvoltage Maximum Voltage LONG 0 Electric_Combined_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG 0 ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
grounding Grounding SHORT Electric_Ground_Configuration True
commonconductortype Material Label SHORT Electric_Combined_Conductor_Material True
neutraltype Neutral Material SHORT Electric_Neutral_Material True
sharedneutral Shared Neutral SHORT Yes_No True
tiername Tier Name SHORT True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status_Combined False
inservicedate In-Service Date DATE True
retireddate Retired Date DATE True
measuredlength Measured Length DOUBLE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
installdate Install Date DATE True
ohm Ohm Per Length DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
normaloperatingstatus Normal Operating Status SHORT Electric_Operating_Status True
conductorsperphase Conductors Per Phase SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
isvalidloop Participates in a valid loop SHORT Yes_No_Simple True
withstandrating BIL or Withstand Voltage Rating LONG Electric_BIL_Combined True
conductormaterial conductormaterial SHORT Electric_Connector_Material True
conductorinsulationmaterial conductorinsulationmaterial SHORT Electric_Wire_Insulation_Material True
conductorsize conductorsize DOUBLE Electric_Wire_Diameter_in True
conductorsizemetric conductorsizemetric DOUBLE Electric_Wire_Diameter_metric True
kcmil Circular Mil DOUBLE Electric_Wire_kcmil True
conductorfulldiameter Conductor Full Diameter DOUBLE Electric_Wire_FullDiameter True
conductorfulldiameter_metric Conductor Full Diameter DOUBLE Electric_Wire_FullDiameter_metric True
conductorinsulationthickness Conductor Insulation Thickness DOUBLE Electric_Wire_Insulation_Thickness True
conductorinsulationthich_m Conductor Insulation Thickness DOUBLE Electric_Wire_Insulation_Thickness_metric True
conductorsheaththickness Conductor Sheath Thickness DOUBLE Electric_Wire_Sheath_Thickness True
conductorsheaththickness_metr Conductor Sheath Thickness DOUBLE Electric_Wire_Sheath_Thickness_metric True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtypes
Code Name Description
0 Unknown The Unknown asset group in the ElectricLine feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it.
11 Neutral Wire Neutral lines are used in cases where there is only neutral or a common neutral shared between different electrical circuits.
12 Ground Wire Ground lines are used in cases where there is only a ground cable that is separate from the Neutral
2 High Voltage Overhead Conductor High Voltage lines represent Transmission and Sub transmission voltage cables and are typically polyphase lines that represent multiple lines per phase. Lines can be Alternating (AC) or Direct Current (DC).
31 High Voltage Underground Conductor
32 High Voltage Submersible Conductor
1 High Voltage Busbar Busbar is solid conductor used in substations on the high voltage side of equipment.
3 High Voltage Connector A line used to connect equipment, but would not be considered trackable cable.
4 High Voltage Static Wire A grounded shield wire, typically located above overhead transmission lines.
15 High Voltage Service
9 Medium Voltage Overhead Conductor Medium Voltage lines represent Distribution or Sub transmission cables, can be polyphase lines that represent multiple lines per phase.
34 Medium Voltage Underground Conductor
35 Medium Voltage Submersible Conductor
8 Medium Voltage Busbar Busbar is solid conductor used in cabinets or substations on the medium voltage side of equipment.
10 Medium Voltage Connector A line used to connect equipment, but would not be considered trackable cable.
14 Medium Voltage Service
5 Low Voltage Busbar Busbar is solid conductor used in cabinets or substations on the low voltage side of equipment.
7 Low Voltage Connector A line used to connect equipment, but would not be considered trackable cable.
13 Low Voltage Service A low voltage line to provide electric service
6 Low Voltage Overhead Conductor Low Voltage lines represent secondary or low voltage cables, can be polyphase lines that represent multiple lines per phase. Lines can be Alternating (AC) or Direct Current (DC).
37 Low Voltage Underground Conductor
38 Low Voltage Submersible Conductor
Subtype: Unknown
The Unknown asset group in the ElectricLine feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 UtilityNetwork_5_UnknownAssetType False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
fromdeviceterminal From device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
todeviceterminal To device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Attribution_All False
phasechange Phase Change SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT 0 Electric_Phase_Attribution_All False
phasesenergized Phases Energized SHORT 0 Electric_Phase_Attribution_All True
commonconductortype Material Label SHORT True
tiername Tier name SHORT True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
measuredlength Measured Length DOUBLE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
ohm Ohm Per Length DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
normaloperatingstatus Bank Status SHORT True
conductorsperphase Conductors Per Phase SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Unknown: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A object used to connect objects in the low voltage DC system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Neutral Wire
Neutral lines are used in cases where there is only neutral or a common neutral shared between different electrical circuits.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Line_Neutral False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
fromdeviceterminal From device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
todeviceterminal To device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Attribution_All False
phasechange Phase Change SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT 0 Electric_Phase_Attribution_All False
phasesenergized Phases Energized SHORT 0 Electric_Phase_Attribution_All True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
maxvoltage Maximum Voltage LONG True
nominalvoltage Nominal Voltage (L-L) LONG True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
commonconductortype Material Label SHORT Electric_Neutral_Material True
neutraltype Neutral Material SHORT True
sharedneutral Shared Neutral SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
inservicedate In-Service Date DATE True
retireddate Retired Date DATE True
measuredlength Measured Length DOUBLE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
installdate Install Date DATE True
ohm Ohm Per Length DOUBLE Electric_Ohms_per_KM True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Neutral Wire: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Neutral Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
200 Overhead Bare A bare overhead neutral. Single terminal ['Asset Location', 'E:Cable', 'E:Cable - Overhead', 'E:Ground'] CONTAINER SPLIT ANY_VERTEX
201 Overhead Shielded An overhead shielded overhead neutral. Single terminal ['Asset Location', 'E:Cable', 'E:Cable - Overhead', 'E:Ground'] CONTAINER SPLIT ANY_VERTEX
202 Underground Shielded An underground shielded overhead neutral. Single terminal ['Asset Location', 'E:Cable', 'E:Cable - Underground', 'E:Ground'] CONTAINER SPLIT ANY_VERTEX
Subtype: Ground Wire
Ground lines are used in cases where there is only a ground cable that is separate from the Neutral
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Line_Ground False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
fromdeviceterminal From device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
todeviceterminal To device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Not_Applicable False
phasechange Phase Change SHORT Electric_Phase_Not_Applicable True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Not_Applicable False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Not_Applicable False
phasesplan Planned Phases SHORT 0 Electric_Phase_Not_Applicable False
phasesenergized Phases Energized SHORT 0 Electric_Phase_Not_Applicable True
commonconductortype Material Label SHORT Electric_Ground_Material True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
inservicedate In-Service Date DATE True
retireddate Retired Date DATE True
measuredlength Measured Length DOUBLE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
installdate Install Date DATE True
ohm Ohm Per Length DOUBLE Electric_Ohms_per_KM True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Ground Wire: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Ground. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
221 Covered Ground A shielded ground cable Single terminal ['Asset Location', 'E:Ground'] CONTAINER SPLIT ANY_VERTEX
222 Bare Ground A unshielded ground cable Single terminal ['Asset Location', 'E:Ground'] CONTAINER SPLIT ANY_VERTEX
Subtype: High Voltage Overhead Conductor
High Voltage lines represent Transmission and Sub transmission voltage cables and are typically polyphase lines that represent multiple lines per phase. Lines can be Alternating (AC) or Direct Current (DC).
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Line_High_Voltage_Overhead_Conductor False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
fromdeviceterminal From device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
todeviceterminal To device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_High_Voltage_Phases_Constructed True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
nominalvoltage Nominal Voltage (L-L) LONG Electric_High_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
grounding Grounding SHORT Electric_Ground_Configuration True
commonconductortype Material Label SHORT Electric_High_Voltage_Conductor_Material True
neutraltype Neutral Material SHORT Electric_Neutral_Material True
sharedneutral Shared Neutral SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
inservicedate In-Service Date DATE True
retireddate Retired Date DATE True
measuredlength Measured Length DOUBLE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
installdate Install Date DATE True
ohm Ohm Per Length DOUBLE Electric_Ohms_per_KM True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
normaloperatingstatus Current Operating Status SHORT Electric_Operating_Status True
conductorsperphase Conductors Per Phase SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: High Voltage Overhead Conductor: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A group of unknown conductor types in the High Voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
20 AC Overhead HV A group of aerial conductors in the high voltage AC system Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage', 'E:Cable - Overhead', 'E:Conductor'] CONTAINER SPLIT ANY_VERTEX
23 DC Overhead HV A group of aerial conductors in the high voltage DC system Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage', 'E:Cable - Overhead', 'E:Conductor'] CONTAINER SPLIT ANY_VERTEX
Subtype: High Voltage Underground Conductor
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT Asset_Type_Electric_Line_High_Voltage_Underground_Conductor False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
fromdeviceterminal From device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
todeviceterminal To device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_High_Voltage_Phases_Constructed True
maxvoltage Maximum Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
maxoperatingvoltage Maximum Operating Voltage LONG True
nominalvoltage Nominal Voltage (L-L) LONG Electric_High_Voltage_Nominal_Voltage True
grounding Grounding SHORT Electric_Ground_Configuration True
commonconductortype Material Label SHORT Electric_High_Voltage_Conductor_Material True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
inservicedate In-Service Date DATE True
retireddate Retired Date DATE True
measuredlength Measured Length DOUBLE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
installdate Install Date DATE True
ohm Ohm Per Length DOUBLE Electric_Ohms_per_KM True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
conductorsperphase Conductors Per Phase SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: High Voltage Underground Conductor: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
22 AC Underground HV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage', 'E:Cable - Underground', 'E:Conductor'] CONTAINER SPLIT ANY_VERTEX
25 DC Underground HV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage', 'E:Cable - Underground', 'E:Conductor'] CONTAINER SPLIT ANY_VERTEX
Subtype: High Voltage Submersible Conductor
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Line_High_Voltage_Submersible_Conductor False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
fromdeviceterminal From device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
todeviceterminal To device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_High_Voltage_Phases_Constructed True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
nominalvoltage Nominal Voltage (L-L) LONG Electric_High_Voltage_Nominal_Voltage True
grounding Grounding SHORT Electric_Ground_Configuration True
commonconductortype Material Label SHORT Electric_High_Voltage_Conductor_Material True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
inservicedate In-Service Date DATE True
retireddate Retired Date DATE True
measuredlength Measured Length DOUBLE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
installdate Install Date DATE True
ohm Ohm Per Length DOUBLE Electric_Ohms_per_KM True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
conductorsperphase Conductors Per Phase SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: High Voltage Submersible Conductor: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
21 AC Submersible HV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage', 'E:Cable - Submersible', 'E:Conductor'] CONTAINER SPLIT ANY_VERTEX
24 DC Submersible HV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage', 'E:Cable - Submersible', 'E:Conductor'] CONTAINER SPLIT ANY_VERTEX
Subtype: High Voltage Busbar
Busbar is solid conductor used in substations on the high voltage side of equipment.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Line_High_Voltage_Busbar False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
fromdeviceterminal From device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
todeviceterminal To device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_High_Voltage_Phases_Constructed True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
nominalvoltage Nominal Voltage (L-L) LONG Electric_High_Voltage_Nominal_Voltage True
grounding Grounding SHORT Electric_Ground_Configuration True
commonconductortype Material Label SHORT Electric_Busbar_Material True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
inservicedate In-Service Date DATE True
retireddate Retired Date DATE True
measuredlength Measured Length DOUBLE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
installdate Install Date DATE True
ohm Ohm Per Length DOUBLE Electric_Ohms_per_KM True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: High Voltage Busbar: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A group of solid conductors used in the high voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
1 AC Station Single Phase HV A solid single conductor used in a station in the high voltage AC system Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage', 'E:Station'] CONTAINER SPLIT ANY_VERTEX
2 AC Station Three Phase HV A group of three solid conductors used in a station in the high voltage AC system Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage', 'E:Station'] CONTAINER SPLIT ANY_VERTEX
3 DC Station HV A solid conductor used in a station in the high voltage DC system Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage', 'E:Station'] CONTAINER SPLIT ANY_VERTEX
Subtype: High Voltage Connector
A line used to connect equipment, but would not be considered trackable cable.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Line_High_Voltage_Connector False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
fromdeviceterminal From device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
todeviceterminal To device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_High_Voltage_Phases_Constructed True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
nominalvoltage Nominal Voltage (L-L) LONG Electric_High_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG True
grounding Grounding SHORT Electric_Ground_Configuration True
commonconductortype Material Label SHORT Electric_Connector_Material True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
inservicedate In-Service Date DATE True
retireddate Retired Date DATE True
measuredlength Measured Length DOUBLE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
installdate Install Date DATE True
ohm Ohm Per Length DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
normaloperatingstatus Current Operating Status SHORT Electric_Operating_Status True
conductorsperphase Conductors Per Phase SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: High Voltage Connector: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown High Voltage Connector on unknown type Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
40 AC Connector HV A high voltage connector line used in lieu of explicit connectivity associations Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High Voltage'] CONTAINER SPLIT ANY_VERTEX
41 DC Connector HV A high voltage connector line used in lieu of explicit connectivity associations Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High Voltage'] CONTAINER SPLIT ANY_VERTEX
Subtype: High Voltage Static Wire
A grounded shield wire, typically located above overhead transmission lines.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Line_High_Voltage_Static_Wire False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
fromdeviceterminal From device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
todeviceterminal To device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Not_Applicable False
phasechange Phase Change SHORT Electric_Phase_Not_Applicable True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Not_Applicable False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Not_Applicable False
phasesplan Planned Phases SHORT 0 Electric_Phase_Not_Applicable False
phasesenergized Phases Energized SHORT 0 Electric_Phase_Not_Applicable True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
maxvoltage Maximum Voltage LONG True
nominalvoltage Nominal Voltage (L-L) LONG True
nominalvoltagelg Nominal Voltage (L-G) LONG True
commonconductortype Material Label SHORT Electric_StaticWire_Material True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
inservicedate In-Service Date DATE True
retireddate Retired Date DATE True
measuredlength Measured Length DOUBLE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
installdate Install Date DATE True
ohm Ohm Per Length DOUBLE Electric_Ohms_per_KM True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: High Voltage Static Wire: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
60 Double Single terminal ['Asset Location', 'E:Cable', 'E:Ground'] CONTAINER SPLIT ANY_VERTEX
61 Single Single terminal ['Asset Location', 'E:Cable', 'E:Ground'] CONTAINER SPLIT ANY_VERTEX
Subtype: High Voltage Service
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Line_High_Voltage_Service False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
fromdeviceterminal From device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
todeviceterminal To device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
nominalvoltage Nominal Voltage (L-L) LONG Electric_High_Voltage_Nominal_Voltage True
grounding Grounding SHORT Electric_Ground_Configuration True
commonconductortype Material Label SHORT Electric_High_Voltage_Conductor_Material True
neutraltype Neutral Material SHORT Electric_Neutral_Material True
sharedneutral Shared Neutral SHORT Yes_No True
tiername Tier name SHORT True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
inservicedate In-Service Date DATE True
retireddate Retired Date DATE True
measuredlength Measured Length DOUBLE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
installdate Install Date DATE True
ohm Ohm Per Length DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
conductorsperphase Conductors Per Phase SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: High Voltage Service: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
260 AC Overhead Service HV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - Overhead'] CONTAINER SPLIT END_VERTEX
261 AC Underground Service HV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - Underground'] CONTAINER SPLIT END_VERTEX
262 DC Overhead Service HV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - Overhead'] CONTAINER SPLIT END_VERTEX
263 DC Underground Service HV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - Underground'] CONTAINER SPLIT END_VERTEX
264 AC Submersible Service HV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - Submersible'] CONTAINER SPLIT END_VERTEX
265 DC Submersible Service HV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - Submersible'] CONTAINER SPLIT END_VERTEX
Subtype: Medium Voltage Overhead Conductor
Medium Voltage lines represent Distribution or Sub transmission cables, can be polyphase lines that represent multiple lines per phase.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Line_Medium_Voltage_Overhead_Conductor False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
fromdeviceterminal From device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
todeviceterminal To device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
grounding Grounding SHORT Electric_Ground_Configuration True
commonconductortype Material Label SHORT Electric_Medium_Voltage_Conductor_Material True
neutraltype Neutral Material SHORT Electric_Neutral_Material True
sharedneutral Shared Neutral SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
inservicedate In-Service Date DATE True
retireddate Retired Date DATE True
measuredlength Measured Length DOUBLE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
installdate Install Date DATE True
ohm Ohm Per Length DOUBLE Electric_Ohms_per_KM True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
normaloperatingstatus Current Operating Status SHORT Electric_Operating_Status True
conductorsperphase Conductors Per Phase SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Medium Voltage Overhead Conductor: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A group of unknown conductor types in the medium Voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
160 Overhead Single Phase MV A group of aerial conductors in the medium voltage system of the same phase Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High and Medium Voltage', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Overhead', 'E:Conductor'] CONTAINER SPLIT ANY_VERTEX
161 Overhead Three Phase MV A group of aerial conductors in the medium voltage system representing all three phases Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High and Medium Voltage', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Overhead', 'E:Conductor'] CONTAINER SPLIT ANY_VERTEX
162 Overhead Two Phase MV A group of aerial conductors in the medium voltage system representing two phases Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High and Medium Voltage', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Overhead', 'E:Conductor'] CONTAINER SPLIT ANY_VERTEX
Subtype: Medium Voltage Underground Conductor
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Line_Medium_Voltage_Underground_Conductor False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
fromdeviceterminal From device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
todeviceterminal To device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
grounding Grounding SHORT Electric_Ground_Configuration True
commonconductortype Material Label SHORT Electric_Medium_Voltage_Conductor_Material True
neutraltype Neutral Material SHORT Electric_Neutral_Material True
sharedneutral Shared Neutral SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
inservicedate In-Service Date DATE True
retireddate Retired Date DATE True
measuredlength Measured Length DOUBLE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
installdate Install Date DATE True
ohm Ohm Per Length DOUBLE Electric_Ohms_per_KM True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
conductorsperphase Conductors Per Phase SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Medium Voltage Underground Conductor: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
165 Underground Single Phase MV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High and Medium Voltage', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Underground', 'E:Conductor'] CONTAINER SPLIT ANY_VERTEX
166 Underground Three Phase MV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High and Medium Voltage', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Underground', 'E:Conductor'] CONTAINER SPLIT ANY_VERTEX
167 Underground Two Phase MV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High and Medium Voltage', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Underground', 'E:Conductor'] CONTAINER SPLIT ANY_VERTEX
Subtype: Medium Voltage Submersible Conductor
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Line_Medium_Voltage_Submersible_Conductor False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
fromdeviceterminal From device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
todeviceterminal To device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
grounding Grounding SHORT Electric_Ground_Configuration True
commonconductortype Material Label SHORT Electric_Medium_Voltage_Conductor_Material True
neutraltype Neutral Material SHORT Electric_Neutral_Material True
sharedneutral Shared Neutral SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
inservicedate In-Service Date DATE True
retireddate Retired Date DATE True
measuredlength Measured Length DOUBLE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
installdate Install Date DATE True
ohm Ohm Per Length DOUBLE Electric_Ohms_per_KM True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
conductorsperphase Conductors Per Phase SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Medium Voltage Submersible Conductor: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
163 Submersible Single Phase MV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High and Medium Voltage', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Submersible', 'E:Conductor'] CONTAINER SPLIT ANY_VERTEX
164 Submersible Three Phase MV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - High and Medium Voltage', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Submersible', 'E:Conductor'] CONTAINER SPLIT ANY_VERTEX
Subtype: Medium Voltage Busbar
Busbar is solid conductor used in cabinets or substations on the medium voltage side of equipment.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Line_Medium_Voltage_Busbar False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
fromdeviceterminal From device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
todeviceterminal To device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
grounding Grounding SHORT Electric_Ground_Configuration True
commonconductortype Material Label SHORT Electric_Busbar_Material True
neutraltype Neutral Material SHORT Electric_Neutral_Material True
sharedneutral Shared Neutral SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
inservicedate In-Service Date DATE True
retireddate Retired Date DATE True
measuredlength Measured Length DOUBLE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
installdate Install Date DATE True
ohm Ohm Per Length DOUBLE Electric_Ohms_per_KM True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Medium Voltage Busbar: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A group of solid conductors used in the medium voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
140 Cabinet Single Phase MV A single solid conductor used in a cabinet in the medium voltage system Single terminal ['Asset Location', 'E:Cable'] CONTAINER SPLIT ANY_VERTEX
141 Cabinet Three Phase MV A group of three solid conductors used in a cabinet in the medium voltage system Single terminal ['Asset Location', 'E:Cable'] CONTAINER SPLIT ANY_VERTEX
142 Station Single Phase MV A single solid conductor used in a station in the medium voltage system Single terminal ['Asset Location', 'E:Cable', 'E:Station'] CONTAINER SPLIT ANY_VERTEX
143 Station Three Phase MV A group of three solid conductors used in a station in the medium voltage system Single terminal ['Asset Location', 'E:Cable', 'E:Station'] CONTAINER SPLIT ANY_VERTEX
Subtype: Medium Voltage Connector
A line used to connect equipment, but would not be considered trackable cable.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Line_Medium_Voltage_Connector False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
fromdeviceterminal From device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
todeviceterminal To device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
grounding Grounding SHORT Electric_Ground_Configuration True
commonconductortype Material Label SHORT Electric_Connector_Material True
neutraltype Neutral Material SHORT Electric_Neutral_Material True
sharedneutral Shared Neutral SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
inservicedate In-Service Date DATE True
retireddate Retired Date DATE True
measuredlength Measured Length DOUBLE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
installdate Install Date DATE True
ohm Ohm Per Length DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
normaloperatingstatus Current Operating Status SHORT Electric_Operating_Status True
conductorsperphase Conductors Per Phase SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Medium Voltage Connector: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Medium Voltage Connector on unknown type Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
180 Single Phase MV A medium voltage single phase connector used in lieu of explicit connectivity associations Single terminal ['Asset Location', 'E:Cable'] CONTAINER SPLIT ANY_VERTEX
181 Three Phase MV A medium voltage three phase connector used in lieu of explicit connectivity associations Single terminal ['Asset Location', 'E:Cable'] CONTAINER SPLIT ANY_VERTEX
182 Two Phase MV A medium voltage two phase connector used in lieu of explicit connectivity associations Single terminal ['Asset Location', 'E:Cable'] CONTAINER SPLIT ANY_VERTEX
Subtype: Medium Voltage Service
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Line_Medium_Voltage_Service False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
fromdeviceterminal From device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
todeviceterminal To device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
grounding Grounding SHORT Electric_Ground_Configuration True
commonconductortype Material Label SHORT Electric_Connector_Material True
neutraltype Neutral Material SHORT Electric_Neutral_Material True
sharedneutral Shared Neutral SHORT Yes_No True
tiername Tier name SHORT True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
inservicedate In-Service Date DATE True
retireddate Retired Date DATE True
measuredlength Measured Length DOUBLE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
installdate Install Date DATE True
ohm Ohm Per Length DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
conductorsperphase Conductors Per Phase SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Medium Voltage Service: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
170 Overhead Single Phase Service MV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Overhead'] CONTAINER SPLIT END_VERTEX
171 Overhead Three Phase Service MV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Overhead'] CONTAINER SPLIT END_VERTEX
172 Overhead Two Phase Service MV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Overhead'] CONTAINER SPLIT END_VERTEX
173 Submersible Single Phase Service MV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Submersible'] CONTAINER SPLIT END_VERTEX
174 Submersible Three Phase Service MV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Submersible'] CONTAINER SPLIT END_VERTEX
175 Underground Single Phase Service MV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Underground'] CONTAINER SPLIT END_VERTEX
176 Underground Three Phase Service MV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Underground'] CONTAINER SPLIT END_VERTEX
177 Underground Two Phase Service MV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - Underground'] CONTAINER SPLIT END_VERTEX
Subtype: Low Voltage Busbar
Busbar is solid conductor used in cabinets or substations on the low voltage side of equipment.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Line_Low_Voltage_Busbar False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
fromdeviceterminal From device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
todeviceterminal To device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
grounding Grounding SHORT Electric_Ground_Configuration True
commonconductortype Material Label SHORT Electric_Busbar_Material True
neutraltype Neutral Material SHORT Electric_Neutral_Material True
sharedneutral Shared Neutral SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
inservicedate In-Service Date DATE True
retireddate Retired Date DATE True
measuredlength Measured Length DOUBLE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
installdate Install Date DATE True
ohm Ohm Per Length DOUBLE Electric_Ohms_per_KM True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Low Voltage Busbar: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A group of solid conductors used in the low voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
80 AC Cabinet LV A solid conductor used in a cabinet in the low voltage AC system Single terminal ['Asset Location', 'E:Cable'] CONTAINER SPLIT ANY_VERTEX
81 AC Station LV A solid conductor used in a station in the low voltage AC system Single terminal ['Asset Location', 'E:Cable', 'E:Station'] CONTAINER SPLIT ANY_VERTEX
82 DC Cabinet LV A solid conductor used in a cabinet in the low voltage DC system Single terminal ['Asset Location', 'E:Cable'] CONTAINER SPLIT ANY_VERTEX
83 DC Station LV A solid conductor used in a station in the low voltage DC system Single terminal ['Asset Location', 'E:Cable', 'E:Station'] CONTAINER SPLIT END_VERTEX
Subtype: Low Voltage Connector
A line used to connect equipment, but would not be considered trackable cable.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Line_Low_Voltage_Connector False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
fromdeviceterminal From device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
todeviceterminal To device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
grounding Grounding SHORT Electric_Ground_Configuration True
commonconductortype Material Label SHORT Electric_Connector_Material True
neutraltype Neutral Material SHORT Electric_Neutral_Material True
sharedneutral Shared Neutral SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
inservicedate In-Service Date DATE True
retireddate Retired Date DATE True
measuredlength Measured Length DOUBLE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
installdate Install Date DATE True
ohm Ohm Per Length DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
normaloperatingstatus Current Operating Status SHORT Electric_Operating_Status True
conductorsperphase Conductors Per Phase SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Low Voltage Connector: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Low Voltage Connector on unknown type Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
120 AC Connector LV A low voltage AC connector used in lieu of explicit connectivity associations Single terminal ['Asset Location', 'E:Cable'] CONTAINER SPLIT ANY_VERTEX
121 DC Connector LV A low voltage DC connector used in lieu of explicit connectivity associations Single terminal ['Asset Location', 'E:Cable'] CONTAINER SPLIT ANY_VERTEX
Subtype: Low Voltage Service
A low voltage line to provide electric service
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Line_Low_Voltage_Service False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
fromdeviceterminal From device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
todeviceterminal To device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
grounding Grounding SHORT Electric_Ground_Configuration True
commonconductortype Material Label SHORT Electric_Low_Voltage_Conductor_Material True
neutraltype Neutral Material SHORT Electric_Neutral_Material True
sharedneutral Shared Neutral SHORT Yes_No True
tiername Tier name SHORT True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
inservicedate In-Service Date DATE True
retireddate Retired Date DATE True
measuredlength Measured Length DOUBLE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
installdate Install Date DATE True
ohm Ohm Per Length DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
conductorsperphase Conductors Per Phase SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Low Voltage Service: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A unknown type of service cable in the low voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
110 AC Overhead Service LV A aerial cable(s) used to provide service to customers in a low voltage AC system Single terminal ['Asset Location', 'E:Cable', 'E:Cable - Low Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Overhead'] CONTAINER SPLIT ANY_VERTEX
112 AC Underground Service LV A underground cable(s) used to provide service to customers in a low voltage AC system Single terminal ['Asset Location', 'E:Cable', 'E:Cable - Low Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Underground'] CONTAINER SPLIT ANY_VERTEX
113 DC Overhead Service LV A aerial cable(s) used to provide service to customers in a low voltage DC system Single terminal ['Asset Location', 'E:Cable', 'E:Cable - Low Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Overhead'] CONTAINER SPLIT END_VERTEX
115 DC Underground Service LV A underground cable(s) used to provide service to customers in a low voltage DC system Single terminal ['Asset Location', 'E:Cable', 'E:Cable - Low Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Underground'] CONTAINER SPLIT ANY_VERTEX
Subtype: Low Voltage Overhead Conductor
Low Voltage lines represent secondary or low voltage cables, can be polyphase lines that represent multiple lines per phase. Lines can be Alternating (AC) or Direct Current (DC).
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Line_Low_Voltage_Overhead_Conductor False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
fromdeviceterminal From device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
todeviceterminal To device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
grounding Grounding SHORT Electric_Ground_Configuration True
commonconductortype Material Label SHORT Electric_Low_Voltage_Conductor_Material True
neutraltype Neutral Material SHORT Electric_Neutral_Material True
sharedneutral Shared Neutral SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
inservicedate In-Service Date DATE True
retireddate Retired Date DATE True
measuredlength Measured Length DOUBLE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
installdate Install Date DATE True
ohm Ohm Per Length DOUBLE Electric_Ohms_per_KM True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
normaloperatingstatus Current Operating Status SHORT Electric_Operating_Status True
conductorsperphase Conductors Per Phase SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Low Voltage Overhead Conductor: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A group of unknown conductor types in the low Voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
100 AC Overhead LV A group of aerial conductors in the low voltage AC system Single terminal ['Asset Location', 'E:Cable', 'E:Cable - Low Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Overhead', 'E:Conductor'] CONTAINER SPLIT ANY_VERTEX
103 DC Overhead LV A group of aerial conductors in the low voltage DC system Single terminal ['Asset Location', 'E:Cable', 'E:Cable - Low Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Overhead', 'E:Conductor'] CONTAINER SPLIT ANY_VERTEX
Subtype: Low Voltage Underground Conductor
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Line_Low_Voltage_Underground_Conductor False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
fromdeviceterminal From device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
todeviceterminal To device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
grounding Grounding SHORT Electric_Ground_Configuration True
commonconductortype Material Label SHORT Electric_Low_Voltage_Conductor_Material True
neutraltype Neutral Material SHORT Electric_Neutral_Material True
sharedneutral Shared Neutral SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
inservicedate In-Service Date DATE True
retireddate Retired Date DATE True
measuredlength Measured Length DOUBLE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
installdate Install Date DATE True
ohm Ohm Per Length DOUBLE Electric_Ohms_per_KM True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
conductorsperphase Conductors Per Phase SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Low Voltage Underground Conductor: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
102 AC Underground LV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - Low Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Underground', 'E:Conductor'] CONTAINER SPLIT ANY_VERTEX
105 DC Underground LV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - Low Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Underground', 'E:Conductor'] CONTAINER SPLIT ANY_VERTEX
Subtype: Low Voltage Submersible Conductor
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Electric_Line_Low_Voltage_Submersible_Conductor False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
fromdeviceterminal From device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
todeviceterminal To device terminal SHORT 0 UtilityNetwork_5_TerminalNames False
shape Shape GEOMETRY False
globalid Global ID GUID False
subnetworkname SubnetworkName TEXT (2000) Unknown False
supportedsubnetworkname Supported subnetwork name TEXT (2000) Unknown False
supportingsubnetworkname Supporting subnetwork name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange Phase Change SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
grounding Grounding SHORT Electric_Ground_Configuration True
commonconductortype Material Label SHORT Electric_Low_Voltage_Conductor_Material True
neutraltype Neutral Material SHORT Electric_Neutral_Material True
sharedneutral Shared Neutral SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
inservicedate In-Service Date DATE True
retireddate Retired Date DATE True
measuredlength Measured Length DOUBLE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
installdate Install Date DATE True
ohm Ohm Per Length DOUBLE Electric_Ohms_per_KM True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
conductorsperphase Conductors Per Phase SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status False
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Low Voltage Submersible Conductor: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
101 AC Submersible LV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - Low Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Submersible', 'E:Conductor'] CONTAINER SPLIT ANY_VERTEX
104 DC Submersible LV Single terminal ['Asset Location', 'E:Cable', 'E:Cable - Low Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Submersible', 'E:Conductor'] CONTAINER SPLIT ANY_VERTEX

ElectricSubnetLine

The system maintained set of subnetworks.
Class Details
DatasetType ShapeType Alias Has Attachment
FEATURE_CLASS SIMPLE ElectricSubnetLine False
Fields
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
subnetworkname Subnetwork name TEXT (64) Unknown False
isdirty Is dirty SHORT 1 UtilityNetwork_5_IsDirty False
tiername Tier name LONG 0 False
subnetworkcontrollernames Subnetwork controller names TEXT (1073741822) Unknown False
lastupdatesubnetwork Last Update Subnetwork DATE True
lastackexportsubnetwork Last ack export subnetwork DATE True
shape Shape GEOMETRY False
globalid Global ID GUID False
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
shape_length SHAPE_Length DOUBLE True
Subtypes
Code Name Description
0 Unknown The Unknown asset group in the ElectricSubnetLine feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it.
1 Electric Generation Subnetwork aggregated lines for the Generation Tier
2 Electric Transmission Subnetwork aggregated lines for the Transmission Station Tier
3 Electric Subtransmission Subnetwork aggregated lines for the Transmission Tier
4 Electric Distribution Primary Subnetwork aggregated lines for the Sub Transmission Station Tier
5 Electric Distribution Line carring electric energy from distribution transformers to electricity meters of end customers using Low Voltage
6 Electric Secondary
Subtype: Unknown
The Unknown asset group in the ElectricSubnetLine feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it.
Name Alias Type Default Value Domain Nullable Description
Subtype: Electric Generation
Subnetwork aggregated lines for the Generation Tier
Name Alias Type Default Value Domain Nullable Description
Subtype: Electric Transmission
Subnetwork aggregated lines for the Transmission Station Tier
Name Alias Type Default Value Domain Nullable Description
Subtype: Electric Subtransmission
Subnetwork aggregated lines for the Transmission Tier
Name Alias Type Default Value Domain Nullable Description
Subtype: Electric Distribution Primary
Subnetwork aggregated lines for the Sub Transmission Station Tier
Name Alias Type Default Value Domain Nullable Description
Subtype: Electric Distribution
Line carring electric energy from distribution transformers to electricity meters of end customers using Low Voltage
Name Alias Type Default Value Domain Nullable Description
Subtype: Electric Secondary
Name Alias Type Default Value Domain Nullable Description

ElectricEdgeObject

The Edge Object class represents non-spatial linear features.
Class Details
DatasetType ShapeType Alias Has Attachment
TABLE Electric Edge Object True
Fields
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG 0 False
assettype Asset type SHORT 0 False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
phasesenergized Phases Propagated SHORT 0 Electric_Phase_Attribution_All True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Attribution_All False
phasechange User Assigned Phases SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT 0 Electric_Phase_Attribution_All False
phasessubstituted Phases Substituted LONG True
dateinstalled Date Installed DATE True
material Material SHORT Electric_Wire_Metal_Material True
diameter Diameter DOUBLE Electric_Wire_Diameter_in True
measuredlength Measured Length DOUBLE True
manufacturer Manufacturer SHORT Electric_Wire_Manufacturer True
yearmanufactured Year Manufactured DATE True
insulationtype Insulation Type SHORT Electric_Wire_Insulation_Type True
wiretype Wire Type SHORT Electric_Wire_Type True
insulationmaxvoltage Insulation Maximum Voltage LONG Electric_Wire_Insulation_Maximum_Voltage True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status_Combined True
summerampacity Summer Ampacity DOUBLE Electric_Wire_Ampacity True
impedance Impedance DOUBLE Electric_Impedance_Range True
winterampacity Winter Ampacity DOUBLE Electric_Wire_Ampacity True
temperaturerating Temperature Rating DOUBLE Electric_Temperature_F True
sctemperaturerating SC Temperature Rating DOUBLE Electric_Temperature_F True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate Inservice Date DATE True
wirenumber Wire Number SHORT True
kcmil kcmil DOUBLE Electric_Wire_kcmil True
wireweight Wire Weight DOUBLE Electric_Wire_Weight True
ratedstrength Rated Strength DOUBLE Electric_Wire_Rated_Strength True
diameter_metric Diameter (Metric) DOUBLE Electric_Wire_Diameter_mm True
temperaturerating_metric Temperature Rating (Metric) DOUBLE Electric_Temperature_C True
sctemperaturerating_metric SC Temperature Rating (Metric) DOUBLE Electric_Temperature_C True
wireweight_metric Wire Weight per 1000 Meters DOUBLE Electric_Wire_Weight_Metric True
ratedstrength_metric Wire Strength (kg) DOUBLE Electric_Wire_Rated_Strength_Metric True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
normaloperatingstatus Normal Operating Status SHORT Electric_Operating_Status True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
maxvoltage Maximum Voltage LONG Electric_Combined_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
cablegroupid cablegroupid SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status True
sectionid Section ID TEXT (2000) True
assetid Asset ID TEXT (2000) True
designtype designtype SHORT Electric_Wire_Insulation_Type True
equipmenttype equipmenttype SHORT Electric_Wire_Type True
primarygroundimpedance primarygroundimpedance DOUBLE Electric_Wire_Ampacity True
z0psimpedance z0psimpedance DOUBLE Electric_Wire_Ampacity True
z0xmimpedance z0xmimpedance DOUBLE Electric_Wire_Ampacity True
validationstatus Validation status SHORT 6 True
isvalidloop Participates in a valid loop SHORT Yes_No_Simple True
withstandrating BIL or Withstand Voltage Rating LONG Electric_BIL_Combined True
conductormaterial Condutor Material SHORT Electric_Connector_Material True
conductorinsulationmaterial Conductor Insulation Material SHORT Electric_Wire_Insulation_Material True
conductorsize Conductor Diameter DOUBLE Electric_Wire_Diameter_in True
conductorsizemetric Conductor Size Metric DOUBLE Electric_Wire_Diameter_metric True
conductorfulldiameter Conductor Full Diameter DOUBLE Electric_Wire_FullDiameter True
conductorfulldiameter_metric Conductor Full Diameter DOUBLE Electric_Wire_FullDiameter_metric True
conductorinsulationthickness Conductor Insulation Thickness DOUBLE Electric_Wire_Insulation_Thickness True
conductorinsulationthich_m Conductor Insulation Thickness DOUBLE Electric_Wire_Insulation_Thickness_metric True
conductorsheaththickness Conductor Sheath Thickness DOUBLE Electric_Wire_Sheath_Thickness True
conductorsheaththickness_metr Conductor Sheath Thickness DOUBLE Electric_Wire_Sheath_Thickness_metric True
Subtypes
Code Name Description
0 Unknown The Unknown asset group in the ElectricEdgeObject class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it.
101 Aerial Bare Overhead Electric cables that are not shielded
102 Aerial Covered Overhead Electric cables that are shielded to prevent arcing
104 Busbar Solid non-flexible conductors, typically found in stations
105 Underground Underground Conductor Cables
106 Neutral Electric conductors used as Neutral
107 Ground Electric conductors used to connect to grounds
108 Submarine Electric conductors used in under water situations
109 Connector A Edge feature used to connect non-spatial junction features
Subtype: Unknown
The Unknown asset group in the ElectricEdgeObject class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 UtilityNetwork_5_UnknownAssetType False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
phasesenergized Phases Propagated SHORT 0 Electric_Phase_Attribution_All True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Attribution_All False
phasechange User Assigned Phases SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT 0 Electric_Phase_Attribution_All False
phasessubstituted Phases Substituted LONG True
dateinstalled Date Installed DATE True
material Material SHORT True
diameter Diameter DOUBLE True
measuredlength Measured Length DOUBLE True
manufacturer Manufacturer SHORT True
yearmanufactured Year Manufactured DATE True
insulationtype Insulation Type SHORT True
wiretype Wire Type SHORT True
insulationmaxvoltage Insulation Maximum Voltage LONG True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status True
summerampacity Summer Ampacity DOUBLE True
impedance Impedance DOUBLE True
winterampacity Winter Ampacity DOUBLE True
temperaturerating Temperature Rating DOUBLE True
sctemperaturerating SC Temperature Rating DOUBLE True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate Inservice Date DATE True
wirenumber Wire Number SHORT True
kcmil kcmil DOUBLE True
wireweight Wire Weight DOUBLE True
ratedstrength Rated Strength DOUBLE True
temperaturerating_metric Temperature Rating (Metric) DOUBLE True
sctemperaturerating_metric SC Temperature Rating (Metric) DOUBLE True
wireweight_metric Wire Weight per 1000 Meters DOUBLE True
ratedstrength_metric Wire Strength (kg) DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
normaloperatingstatus Normal Line Status SHORT True
nominalvoltage Nominal Operating Voltage (L-L) LONG True
maxvoltage Maximum Voltage LONG True
maxoperatingvoltage Maximum Operating Voltage LONG True
cablegroupid cablegroupid SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status True
sectionid Section ID TEXT (2000) True
assetid Asset ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Unknown: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Aerial Bare
Overhead Electric cables that are not shielded
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_EdgeObject_Aerial_Bare False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
phasesenergized Phases Propagated SHORT 0 Electric_Phase_Attribution_All True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Attribution_All False
phasechange User Assigned Phases SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT 0 Electric_Phase_Attribution_All False
phasessubstituted Phases Substituted LONG True
dateinstalled Date Installed DATE True
material Material SHORT Electric_Wire_Metal_Material True
diameter Diameter DOUBLE True
measuredlength Measured Length DOUBLE True
manufacturer Manufacturer SHORT Electric_Wire_Manufacturer True
yearmanufactured Year Manufactured DATE True
insulationtype Insulation Type SHORT True
wiretype Wire Type SHORT True
insulationmaxvoltage Insulation Maximum Voltage LONG True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status True
summerampacity Summer Ampacity DOUBLE Electric_Wire_Ampacity True
impedance Impedance DOUBLE Electric_Impedance_Range True
winterampacity Winter Ampacity DOUBLE Electric_Wire_Ampacity True
temperaturerating Temperature Rating DOUBLE Electric_Temperature_F True
sctemperaturerating SC Temperature Rating DOUBLE Electric_Temperature_F True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate Inservice Date DATE True
wirenumber Wire Number SHORT True
kcmil kcmil DOUBLE Electric_Wire_kcmil True
wireweight Wire Weight DOUBLE Electric_Wire_Weight True
ratedstrength Rated Strength DOUBLE Electric_Wire_Rated_Strength True
temperaturerating_metric Temperature Rating (Metric) DOUBLE Electric_Temperature_C True
sctemperaturerating_metric SC Temperature Rating (Metric) DOUBLE Electric_Temperature_C True
wireweight_metric Wire Weight per 1000 Meters DOUBLE Electric_Wire_Weight_Metric True
ratedstrength_metric Wire Strength (kg) DOUBLE Electric_Wire_Rated_Strength_Metric True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
normaloperatingstatus Normal Line Status SHORT True
nominalvoltage Nominal Operating Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
maxvoltage Maximum Voltage LONG True
maxoperatingvoltage Maximum Operating Voltage LONG True
cablegroupid cablegroupid SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status True
sectionid Section ID TEXT (2000) True
assetid Asset ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Aerial Bare: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Aerial Bare. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
901 High Voltage AC A object representing a single Aerial Bare Cable used in the high voltage AC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage', 'E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
902 High Voltage DC A object representing a single Aerial Bare Cable used in the high voltage DC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage', 'E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
903 Medium Voltage A object representing a single Aerial Bare Cable used in the medium voltage system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High and Medium Voltage', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
904 Low Voltage AC A object representing a single Aerial Bare Cable used in the low voltage AC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Low Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
905 Low Voltage DC A object representing a single Aerial Bare Cable used in the low voltage DC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Low Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Aerial Covered
Overhead Electric cables that are shielded to prevent arcing
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_EdgeObject_Aerial_Covered False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
phasesenergized Phases Propagated SHORT 0 Electric_Phase_Attribution_All True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Attribution_All False
phasechange User Assigned Phases SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT 0 Electric_Phase_Attribution_All False
phasessubstituted Phases Substituted LONG True
dateinstalled Date Installed DATE True
material Material SHORT Electric_Wire_Metal_Material True
diameter Diameter DOUBLE Electric_Wire_Diameter_in True
measuredlength Measured Length DOUBLE True
manufacturer Manufacturer SHORT Electric_Wire_Manufacturer True
yearmanufactured Year Manufactured DATE True
insulationtype Insulation Type SHORT True
wiretype Wire Type SHORT True
insulationmaxvoltage Insulation Maximum Voltage LONG True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status True
summerampacity Summer Ampacity DOUBLE Electric_Wire_Ampacity True
impedance Impedance DOUBLE Electric_Impedance_Range True
winterampacity Winter Ampacity DOUBLE Electric_Wire_Ampacity True
temperaturerating Temperature Rating DOUBLE Electric_Temperature_F True
sctemperaturerating SC Temperature Rating DOUBLE Electric_Temperature_F True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate Inservice Date DATE True
wirenumber Wire Number SHORT True
kcmil kcmil DOUBLE Electric_Wire_kcmil True
wireweight Wire Weight DOUBLE Electric_Wire_Weight True
ratedstrength Rated Strength DOUBLE Electric_Wire_Rated_Strength True
temperaturerating_metric Temperature Rating (Metric) DOUBLE Electric_Temperature_C True
sctemperaturerating_metric SC Temperature Rating (Metric) DOUBLE Electric_Temperature_C True
wireweight_metric Wire Weight per 1000 Meters DOUBLE Electric_Wire_Weight_Metric True
ratedstrength_metric Wire Strength (kg) DOUBLE Electric_Wire_Rated_Strength_Metric True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
normaloperatingstatus Normal Line Status SHORT True
nominalvoltage Nominal Operating Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
maxvoltage Maximum Voltage LONG Electric_Combined_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Combined_Maximumm_Operating_Voltage_LL True
cablegroupid cablegroupid SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status True
sectionid Section ID TEXT (2000) True
assetid Asset ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Aerial Covered: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Aerial Covered. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
901 High Voltage AC A object representing a single Aerial Covered or Shielded Cable used in the high voltage AC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage'] NONE DO_NOT_SPLIT END_VERTEX
902 High Voltage DC A object representing a single Aerial Covered or Shielded Cable used in the high voltage DC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage'] NONE DO_NOT_SPLIT END_VERTEX
903 Medium Voltage A object representing a single Aerial Covered or Shielded Cable used in the medium voltage system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High and Medium Voltage', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
904 Low Voltage AC A object representing a single Aerial Covered or Shielded Cable used in the low voltage AC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Low Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
905 Low Voltage DC A object representing a single Aerial Covered or Shielded Cable used in the low voltage DC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Low Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Busbar
Solid non-flexible conductors, typically found in stations
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_EdgeObject_Busbar False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
phasesenergized Phases Propagated SHORT 0 Electric_Phase_Attribution_All True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Attribution_All False
phasechange User Assigned Phases SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT 0 Electric_Phase_Attribution_All False
phasessubstituted Phases Substituted LONG True
dateinstalled Date Installed DATE True
material Material SHORT Electric_Wire_Metal_Material True
diameter Diameter DOUBLE Electric_Wire_Diameter_in True
measuredlength Measured Length DOUBLE True
manufacturer Manufacturer SHORT Electric_Wire_Manufacturer True
yearmanufactured Year Manufactured DATE True
insulationtype Insulation Type SHORT True
wiretype Wire Type SHORT True
insulationmaxvoltage Insulation Maximum Voltage LONG True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status True
summerampacity Summer Ampacity DOUBLE Electric_Wire_Ampacity True
impedance Impedance DOUBLE Electric_Impedance_Range True
winterampacity Winter Ampacity DOUBLE Electric_Wire_Ampacity True
temperaturerating Temperature Rating DOUBLE Electric_Temperature_F True
sctemperaturerating SC Temperature Rating DOUBLE Electric_Temperature_F True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate Inservice Date DATE True
wirenumber Wire Number SHORT True
kcmil kcmil DOUBLE Electric_Wire_kcmil True
wireweight Wire Weight DOUBLE Electric_Wire_Weight True
ratedstrength Rated Strength DOUBLE Electric_Wire_Rated_Strength True
temperaturerating_metric Temperature Rating (Metric) DOUBLE Electric_Temperature_C True
sctemperaturerating_metric SC Temperature Rating (Metric) DOUBLE Electric_Temperature_C True
wireweight_metric Wire Weight per 1000 Meters DOUBLE Electric_Wire_Weight_Metric True
ratedstrength_metric Wire Strength (kg) DOUBLE Electric_Wire_Rated_Strength_Metric True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
normaloperatingstatus Normal Line Status SHORT True
nominalvoltage Nominal Operating Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
maxvoltage Maximum Voltage LONG Electric_Combined_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Combined_Maximumm_Operating_Voltage_LL True
cablegroupid cablegroupid SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status True
sectionid Section ID TEXT (2000) True
assetid Asset ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Busbar: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Busbar. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
901 High Voltage AC A object representing a single busbar in the high voltage AC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage'] NONE DO_NOT_SPLIT END_VERTEX
902 High Voltage DC A object representing a single busbar in the high voltage DC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage'] NONE DO_NOT_SPLIT END_VERTEX
903 Medium Voltage A object representing a single busbar in the medium voltage system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High and Medium Voltage', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage'] NONE DO_NOT_SPLIT END_VERTEX
904 Low Voltage AC A object representing a single busbar in the low voltage AC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Low Voltage'] NONE DO_NOT_SPLIT END_VERTEX
905 Low Voltage DC A object representing a single busbar in the low voltage DC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Low Voltage'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Underground
Underground Conductor Cables
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_EdgeObject_Underground False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
phasesenergized Phases Propagated SHORT 0 Electric_Phase_Attribution_All True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Attribution_All False
phasechange User Assigned Phases SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT 0 Electric_Phase_Attribution_All False
phasessubstituted Phases Substituted LONG True
dateinstalled Date Installed DATE True
material Material SHORT Electric_Wire_Metal_Material True
diameter Diameter DOUBLE True
measuredlength Measured Length DOUBLE True
manufacturer Manufacturer SHORT Electric_Wire_Manufacturer True
yearmanufactured Year Manufactured DATE True
insulationtype Insulation Type SHORT True
wiretype Wire Type SHORT True
insulationmaxvoltage Insulation Maximum Voltage LONG True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status True
summerampacity Summer Ampacity DOUBLE Electric_Wire_Ampacity True
impedance Impedance DOUBLE Electric_Impedance_Range True
winterampacity Winter Ampacity DOUBLE Electric_Wire_Ampacity True
temperaturerating Temperature Rating DOUBLE Electric_Temperature_F True
sctemperaturerating SC Temperature Rating DOUBLE Electric_Temperature_F True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate Inservice Date DATE True
wirenumber Wire Number SHORT True
kcmil kcmil DOUBLE Electric_Wire_kcmil True
wireweight Wire Weight DOUBLE Electric_Wire_Weight True
ratedstrength Rated Strength DOUBLE Electric_Wire_Rated_Strength True
temperaturerating_metric Temperature Rating (Metric) DOUBLE Electric_Temperature_C True
sctemperaturerating_metric SC Temperature Rating (Metric) DOUBLE Electric_Temperature_C True
wireweight_metric Wire Weight per 1000 Meters DOUBLE Electric_Wire_Weight_Metric True
ratedstrength_metric Wire Strength (kg) DOUBLE Electric_Wire_Rated_Strength_Metric True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
normaloperatingstatus Normal Line Status SHORT True
nominalvoltage Nominal Operating Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
maxvoltage Maximum Voltage LONG Electric_Combined_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Combined_Maximumm_Operating_Voltage_LL True
cablegroupid cablegroupid SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status True
sectionid Section ID TEXT (2000) True
assetid Asset ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Underground: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Underground. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
901 High Voltage AC A object representing a single underground cable, used in the high voltage AC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage', 'E:Cable - Underground'] NONE DO_NOT_SPLIT END_VERTEX
902 High Voltage DC A object representing a single underground cable, used in the high voltage DC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage', 'E:Cable - Underground'] NONE DO_NOT_SPLIT END_VERTEX
903 Medium Voltage A object representing a single underground cable, used in the medium voltage system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High and Medium Voltage', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Underground'] NONE DO_NOT_SPLIT END_VERTEX
904 Low Voltage AC A object representing a single underground cable, used in the low voltage AC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Low Voltage', 'E:Cable - Underground'] NONE DO_NOT_SPLIT END_VERTEX
905 Low Voltage DC A object representing a single underground cable, used in the low voltage DC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Low Voltage'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Neutral
Electric conductors used as Neutral
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_EdgeObject_Neutral False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
phasesenergized Phases Propagated SHORT Electric_Phase_Attribution_All True
phasesnormal Phases Normal SHORT Electric_Phase_Attribution_All False
phasechange User Assigned Phases SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT Electric_Phase_Attribution_All False
phasessubstituted Phases Substituted LONG True
dateinstalled Date Installed DATE True
material Material SHORT Electric_Wire_Metal_Material True
diameter Diameter DOUBLE Electric_Wire_Diameter_in True
measuredlength Measured Length DOUBLE True
manufacturer Manufacturer SHORT Electric_Wire_Manufacturer True
yearmanufactured Year Manufactured DATE True
insulationtype Insulation Type SHORT True
wiretype Wire Type SHORT True
insulationmaxvoltage Insulation Maximum Voltage LONG True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status True
summerampacity Summer Ampacity DOUBLE Electric_Wire_Ampacity True
impedance Impedance DOUBLE Electric_Impedance_Range True
winterampacity Winter Ampacity DOUBLE Electric_Wire_Ampacity True
temperaturerating Temperature Rating DOUBLE Electric_Temperature_F True
sctemperaturerating SC Temperature Rating DOUBLE Electric_Temperature_F True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate Inservice Date DATE True
wirenumber Wire Number SHORT True
kcmil kcmil DOUBLE Electric_Wire_kcmil True
wireweight Wire Weight DOUBLE Electric_Wire_Weight True
ratedstrength Rated Strength DOUBLE Electric_Wire_Rated_Strength True
temperaturerating_metric Temperature Rating (Metric) DOUBLE Electric_Temperature_C True
sctemperaturerating_metric SC Temperature Rating (Metric) DOUBLE Electric_Temperature_C True
wireweight_metric Wire Weight per 1000 Meters DOUBLE Electric_Wire_Weight_Metric True
ratedstrength_metric Wire Strength (kg) DOUBLE Electric_Wire_Rated_Strength_Metric True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
normaloperatingstatus Normal Line Status SHORT True
nominalvoltage Nominal Operating Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
maxvoltage Maximum Voltage LONG True
maxoperatingvoltage Maximum Operating Voltage LONG True
cablegroupid cablegroupid SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status True
sectionid Section ID TEXT (2000) True
assetid Asset ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Neutral: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Neutral. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
910 Overhead Bare A bare overhead neutral. Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Overhead', 'E:Ground'] NONE DO_NOT_SPLIT END_VERTEX
911 Overhead Shielded An overhead shielded overhead neutral. Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Overhead', 'E:Ground'] NONE DO_NOT_SPLIT END_VERTEX
912 Underground Shielded An underground shielded overhead neutral. Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Underground', 'E:Ground'] NONE DO_NOT_SPLIT END_VERTEX
913 Concentric A object that represents the electrical neutral wire of an underground cable Single terminal ['Asset Functional', 'E:Cable', 'E:Ground'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Ground
Electric conductors used to connect to grounds
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_EdgeObject_Ground False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
phasesenergized Phases Propagated SHORT 0 Electric_Phase_Not_Applicable True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Not_Applicable False
phasechange User Assigned Phases SHORT Electric_Phase_Not_Applicable True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Not_Applicable False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Not_Applicable False
phasesplan Planned Phases SHORT 0 Electric_Phase_Not_Applicable False
phasessubstituted Phases Substituted LONG True
dateinstalled Date Installed DATE True
material Material SHORT Electric_Wire_Metal_Material True
diameter Diameter DOUBLE Electric_Wire_Diameter_in True
measuredlength Measured Length DOUBLE True
manufacturer Manufacturer SHORT Electric_Wire_Manufacturer True
yearmanufactured Year Manufactured DATE True
insulationtype Insulation Type SHORT True
wiretype Wire Type SHORT True
insulationmaxvoltage Insulation Maximum Voltage LONG True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status True
summerampacity Summer Ampacity DOUBLE Electric_Wire_Ampacity True
impedance Impedance DOUBLE Electric_Impedance_Range True
winterampacity Winter Ampacity DOUBLE Electric_Wire_Ampacity True
temperaturerating Temperature Rating DOUBLE Electric_Temperature_F True
sctemperaturerating SC Temperature Rating DOUBLE Electric_Temperature_F True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate Inservice Date DATE True
wirenumber Wire Number SHORT True
kcmil kcmil DOUBLE Electric_Wire_kcmil True
wireweight Wire Weight DOUBLE Electric_Wire_Weight True
ratedstrength Rated Strength DOUBLE Electric_Wire_Rated_Strength True
temperaturerating_metric Temperature Rating (Metric) DOUBLE Electric_Temperature_C True
sctemperaturerating_metric SC Temperature Rating (Metric) DOUBLE Electric_Temperature_C True
wireweight_metric Wire Weight per 1000 Meters DOUBLE Electric_Wire_Weight_Metric True
ratedstrength_metric Wire Strength (kg) DOUBLE Electric_Wire_Rated_Strength_Metric True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
normaloperatingstatus Normal Line Status SHORT True
nominalvoltage Nominal Operating Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
maxvoltage Maximum Voltage LONG True
maxoperatingvoltage Maximum Operating Voltage LONG True
cablegroupid cablegroupid SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status True
sectionid Section ID TEXT (2000) True
assetid Asset ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Ground: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Ground. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
921 Covered Ground A shielded ground cable Single terminal ['Asset Functional', 'E:Ground'] NONE DO_NOT_SPLIT END_VERTEX
922 Bare Ground A unshielded ground cable Single terminal ['Asset Functional', 'E:Ground'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Submarine
Electric conductors used in under water situations
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_EdgeObject_Submarine False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
phasesenergized Phases Propagated SHORT 0 Electric_Phase_Attribution_All True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Attribution_All False
phasechange User Assigned Phases SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT 0 Electric_Phase_Attribution_All False
phasessubstituted Phases Substituted LONG True
dateinstalled Date Installed DATE True
material Material SHORT Electric_Wire_Metal_Material True
diameter Diameter DOUBLE Electric_Wire_Diameter_in True
measuredlength Measured Length DOUBLE True
manufacturer Manufacturer SHORT Electric_Wire_Manufacturer True
yearmanufactured Year Manufactured DATE True
insulationtype Insulation Type SHORT True
wiretype Wire Type SHORT True
insulationmaxvoltage Insulation Maximum Voltage LONG True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status True
summerampacity Summer Ampacity DOUBLE Electric_Wire_Ampacity True
impedance Impedance DOUBLE Electric_Impedance_Range True
winterampacity Winter Ampacity DOUBLE Electric_Wire_Ampacity True
temperaturerating Temperature Rating DOUBLE Electric_Temperature_F True
sctemperaturerating SC Temperature Rating DOUBLE Electric_Temperature_F True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate Inservice Date DATE True
wirenumber Wire Number SHORT True
kcmil kcmil DOUBLE Electric_Wire_kcmil True
wireweight Wire Weight DOUBLE Electric_Wire_Weight True
ratedstrength Rated Strength DOUBLE Electric_Wire_Rated_Strength True
temperaturerating_metric Temperature Rating (Metric) DOUBLE Electric_Temperature_C True
sctemperaturerating_metric SC Temperature Rating (Metric) DOUBLE Electric_Temperature_C True
wireweight_metric Wire Weight per 1000 Meters DOUBLE Electric_Wire_Weight_Metric True
ratedstrength_metric Wire Strength (kg) DOUBLE Electric_Wire_Rated_Strength_Metric True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
normaloperatingstatus Normal Line Status SHORT True
nominalvoltage Nominal Operating Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
maxvoltage Maximum Voltage LONG Electric_Combined_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Combined_Maximumm_Operating_Voltage_LL True
cablegroupid cablegroupid SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status True
sectionid Section ID TEXT (2000) True
assetid Asset ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Submarine: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Submarine. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
901 High Voltage AC A object representing a single submarine cable used in the high voltage AC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage'] NONE DO_NOT_SPLIT END_VERTEX
902 High Voltage DC A object representing a single submarine cable used in the high voltage DC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage'] NONE DO_NOT_SPLIT END_VERTEX
903 Medium Voltage A object representing a single submarine cable used in the medium voltage system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High and Medium Voltage', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage'] NONE DO_NOT_SPLIT END_VERTEX
904 Low Voltage AC A object representing a single submarine cable used in the low voltage AC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Low Voltage'] NONE DO_NOT_SPLIT END_VERTEX
905 Low Voltage DC A object representing a single submarine cable used in the low voltage DC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Low Voltage'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Connector
A Edge feature used to connect non-spatial junction features
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT Asset_Type_Electric_EdgeObject_Connector False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
phasesenergized Phases Propagated SHORT 0 Electric_Phase_Attribution_All True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Attribution_All False
phasechange User Assigned Phases SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT 0 Electric_Phase_Attribution_All False
phasessubstituted Phases Substituted LONG True
dateinstalled Date Installed DATE True
material Material SHORT Electric_Wire_Metal_Material True
diameter Diameter DOUBLE Electric_Wire_Diameter_in True
measuredlength Measured Length DOUBLE True
manufacturer Manufacturer SHORT Electric_Wire_Manufacturer True
yearmanufactured Year Manufactured DATE True
insulationtype Insulation Type SHORT Electric_Wire_Insulation_Type True
wiretype Wire Type SHORT Electric_Wire_Type True
insulationmaxvoltage Insulation Maximum Voltage LONG Electric_Wire_Insulation_Maximum_Voltage True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status True
summerampacity Summer Ampacity DOUBLE Electric_Wire_Ampacity True
impedance Impedance DOUBLE Electric_Impedance_Range True
winterampacity Winter Ampacity DOUBLE Electric_Wire_Ampacity True
temperaturerating Temperature Rating DOUBLE Electric_Temperature_F True
sctemperaturerating SC Temperature Rating DOUBLE Electric_Temperature_F True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate Inservice Date DATE True
wirenumber Wire Number SHORT True
kcmil kcmil DOUBLE Electric_Wire_kcmil True
wireweight Wire Weight DOUBLE Electric_Wire_Weight True
ratedstrength Rated Strength DOUBLE Electric_Wire_Rated_Strength True
temperaturerating_metric Temperature Rating (Metric) DOUBLE Electric_Temperature_C True
sctemperaturerating_metric SC Temperature Rating (Metric) DOUBLE Electric_Temperature_C True
wireweight_metric Wire Weight per 1000 Meters DOUBLE Electric_Wire_Weight_Metric True
ratedstrength_metric Wire Strength (kg) DOUBLE Electric_Wire_Rated_Strength_Metric True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
normaloperatingstatus Normal Line Status SHORT Electric_Operating_Status True
nominalvoltage Nominal Operating Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
maxvoltage Maximum Voltage LONG Electric_Combined_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Combined_Maximumm_Operating_Voltage_LL True
cablegroupid cablegroupid SHORT True
constructionstatus Construction Status SHORT 6 Construction_Status True
sectionid Section ID TEXT (2000) True
assetid Asset ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Connector: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Connector. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
901 High Voltage AC A object used to connect objects in the high voltage AC system Single terminal ['Asset Functional', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage'] NONE DO_NOT_SPLIT END_VERTEX
902 High Voltage DC A object used to connect objects in the high voltage DC system Single terminal ['Asset Functional', 'E:Cable - High Voltage'] NONE DO_NOT_SPLIT END_VERTEX
903 Medium Voltage A object used to connect objects in the medium voltage system Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
904 Low Voltage AC A object used to connect objects in the low voltage AC system Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
905 Low Voltage DC A object used to connect objects in the low voltage DC system Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX

ElectricJunctionObject

The Junction Object class represents non-spatial equipment and objects. The wire data is also modeled as junction objects to reduce the system junctions when these objects are only contained.
Class Details
DatasetType ShapeType Alias Has Attachment
TABLE Electric Junction Object True
Fields
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG 0 False
assettype Asset type SHORT 0 False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
planoperatingstatus Planning Operating Status SHORT Electric_Operating_Status True
normaloperatingstatus Normal Operating Status SHORT Electric_Operating_Status True
winteroperatingstatus Winter Operating Status SHORT Electric_Operating_Status True
summeroperatingstatus Summer Operating Status SHORT Electric_Operating_Status True
phasesnormal Phases Normal SHORT Electric_Phase_Attribution_All False
phasechange Phase Change SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT Electric_Phase_Attribution_All False
phasesenergized Phases Energized SHORT Electric_Phase_Attribution_All True
phasessubstituted Phases Substituted LONG Electric_Medium_Voltage_Phase_Substitution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
designtype Design Type SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration_Transformer_Regulator True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondaryvoltagelinetoline Secondary Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondarygrounding Secondary Winding Grounding SHORT Electric_Ground_Configuration_Transformer_Regulator True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
tertiarygrounding Tertiary Winding Grounding SHORT Electric_Ground_Configuration_Transformer_Regulator True
maxvoltage Maximum Voltage LONG Electric_Combined_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Combined_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status_Combined False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance Sequence Impedance -X0 DOUBLE True
x1r1impedance Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Peak Load LONG True
offpeakload Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
upperrange Upper Tempature Range - Operating DOUBLE True
upperrange_metric Upper Tempature Range - Operating (Metric) DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
lowerrange_metric Lower Tempature Range - Operating (Metric) DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT Yes_No True
p2sphaseshift Phase Shift/Phase Angle SHORT Electric_Phase_Shift True
p2tphaseshift Primary to Tertiary Phase Shift SHORT Electric_Phase_Shift True
timedelay Trip Time Delay SHORT Electric_Trip_Delay_Range True
tripcount Lockout Trip Count SHORT Electric_Trip_Count True
tapmaxchange Tap Maximum Change SHORT Electric_Tap_Change_Percent True
optype Operational Type SHORT True
maximumpower Maximum Power LONG True
minimumpower Min Power LONG True
ratedpower Rated Power LONG True
loadtapchangepercent Load Tap Change (%) SHORT Electric_Tap_Change_Percent True
noloadloss No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
primarytosecondaryvectorgroup Primary to Secondary Winding Vector Group SHORT Electric_Winding_Vector_Group True
primarytotertiaryvectorygroup Primary to Tertiary Winding Vector Group SHORT Electric_Winding_Vector_Group True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Equipment Field Operation SHORT Electric_Device_Operation True
operatingmechanism Equipment Field Operating Mechanism SHORT Electric_Device_OperatingMechanism True
primaryphaseshift Phase Shift from Next Upstream Step Transformer SHORT Electric_Transformer_Phase_Shift True
sectionid Section ID TEXT (2000) True
terminalid Section Terminal SHORT True
iscritical Is Critical SHORT Yes_No_Simple True
material Material SHORT Electric_Wire_Metal_Material True
diameter Diameter DOUBLE Electric_Wire_Diameter_in True
measuredlength Measured Length DOUBLE True
yearmanufactured Year Manufactured DATE True
summerampacity Summer Ampacity DOUBLE Electric_Wire_Ampacity True
winterampacity Winter Ampacity DOUBLE Electric_Wire_Ampacity True
temperaturerating Temperature Rating DOUBLE Electric_Temperature_F True
sctemperaturerating SC Temperature Rating DOUBLE Electric_Temperature_F True
kcmil kcmil DOUBLE Electric_Wire_kcmil True
wireweight Wire Weight DOUBLE Electric_Wire_Weight True
ratedstrength Rated Strength DOUBLE Electric_Wire_Rated_Strength True
diameter_metric Diameter (Metric) DOUBLE Electric_Wire_Diameter_mm True
temperaturerating_metric Temperature Rating (Metric) DOUBLE Electric_Temperature_C True
sctemperaturerating_metric SC Temperature Rating (Metric) DOUBLE Electric_Temperature_C True
wireweight_metric Wire Weight per 1000 Meters DOUBLE Electric_Wire_Weight_Metric True
ratedstrength_metric Wire Strength (kg) DOUBLE Electric_Wire_Rated_Strength_Metric True
cablegroupid cablegroupid SHORT True
isvalidloop Participates in a valid loop SHORT Yes_No_Simple True
withstandrating BIL or Withstand Voltage Rating LONG True
conductormateiral Conductor Material SHORT Electric_Connector_Material True
conductorinsulationmaterial Conductor Insulation Material SHORT Electric_Wire_Insulation_Material True
conductorsize Conductor Diamter DOUBLE Electric_Wire_Diameter_in True
conductorsizemetric Conductor Diameter metric DOUBLE Electric_Wire_Diameter_metric True
conductorfulldiameter Conductor Full Diameter DOUBLE Electric_Wire_FullDiameter True
conductorfulldiameter_metric Conductor Full Diameter DOUBLE Electric_Wire_FullDiameter_metric True
conductorinsulationthickness Conductor Insulation Thickness DOUBLE Electric_Wire_Insulation_Thickness True
conductorinsulationthich_m Conductor Insulation Thickness DOUBLE Electric_Wire_Insulation_Thickness_metric True
conductorsheaththickness Conductor Sheath Thickness DOUBLE Electric_Wire_Sheath_Thickness True
conductorsheaththickness_metr Conductor Sheath Thickness DOUBLE Electric_Wire_Sheath_Thickness_metric True
gmd_phasetophase GMD Phase to Phase DOUBLE True
gmd_phasetoneutral GMD Phase to Neutral DOUBLE True
gmd_phasetoground GMD Phase to Earth DOUBLE True
gmd_netrualtoground GMD Neutral to Earth DOUBLE True
cableconfiguration Cable Configuration SHORT Electric_Pole_Top_Configuration True
Subtypes
Code Name Description
0 Unknown The Unknown asset group in the ElectricJunctionObject class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it.
1 Ground A junction used as a Ground, such as a Ground Rod
2 High Voltage Insulating Equipment Arrester devices represent over voltage protective equipment.
3 High Voltage Control Unit A electronic controller used to control the state of equipment used in high voltage systems, such as switches.
43 High Voltage Fuse A device used to protect the system from over current conditions, such as faults.
4 High Voltage Generation A generation facility, such as a group or a single turbine, used in the generation of high volume watts.
5 High Voltage Line Monitor and Relay Line monitors are frequently used in conjunction with SCADA systems to monitor system conditions.
6 High Voltage Power Conversion A device used to convert power type from AC to DC or DC to AC.
7 High Voltage Power Factor Correcting A device used in the correction of the power factor of AC energy.
8 High Voltage Regulator Voltage Regulator devices represent a device that is used in the regulation of voltage on the electric line. It can be a single or polyphase device.
9 High Voltage Service A service location or load point used in the delivery of high voltage power, frequently thought of as a meter location.
10 High Voltage Switch A switch used to control the flow of energy.
11 High Voltage Transformer Transformer devices represent a single electrical transformer. These devices can be by phase or polyphase.
48 High Voltage Transformer Winding
25 Medium Voltage Insulating Equipment A device used to protect equipment from over voltage conditions such as lighting strikes.
26 Medium Voltage Circuit Breaker A type of switch used as a network controller or start of a circuit or feeder.
27 Medium Voltage Control Unit A electronic controller used to control the state of equipment used in medium voltage systems, such as switches.
28 Medium Voltage Elbow A device that can be opened, like a switch, but is used to connect underground cables to bushings on pad mounted or underground equipment, such as transformers. Since they can be opened, they can have similar operational behavior as to a switch.
29 Medium Voltage Fuse A device used to protect the system from over current conditions, such as faults.
30 Medium Voltage Generation A generation facility, such as a group or a single turbine, used in the generation of medium volumes of watts, such as solar farms .
31 Medium Voltage Line Monitor and Relay Line monitors are frequently used in conjunction with SCADA systems to monitor system conditions.
32 Medium Voltage Motor and Pump Pumps and motors, typically used for waste water or storm water management, considered a critical asset during major outage events.
33 Medium Voltage Power Conversion A device used to convert power type from AC to DC or DC to AC.
34 Medium Voltage Power Factor Correcting A device used in the correction of the power factor of AC energy.
35 Medium Voltage Regulator Voltage Regulator devices represent a device that is used in the regulation of voltage on the electric line. It can be a single or polyphase device.
36 Medium Voltage Service A service location or load point used in the delivery of medium voltage power, frequently thought of as a primary meter.
41 Medium Voltage Recloser A self reclosing switch
42 Medium Voltage Sectionalizer A sectionlizing switch
37 Medium Voltage Switch A switch used to control the flow of energy.
38 Medium Voltage Transformer Transformer devices represent a single electrical transformer. These devices can be by phase or polyphase.
47 Medium Voltage Transformer Winding
40 Low Voltage Circuit Breaker A circuit breaker used on low voltage equipment, typically inside of a low voltage station
12 Low Voltage Insulating Equipment A device used to protect equipment from over voltage conditions such as lighting strikes.
13 Low Voltage Control Unit A electronic controller used to control the state of equipment used in low voltage systems, such as switches.
14 Low Voltage Fuse A device used to protect the system from over current conditions, such as faults.
15 Low Voltage Generation Generation devices typically located at a customer residence, like rooftop solar.
16 Low Voltage Lighting A device used for lighting such as a streetlight or flood light.
17 Low Voltage Line Monitor and Relay Line monitors are frequently used in conjunction with SCADA systems to monitor system conditions.
18 Low Voltage Motor A motor, typically used in industrial operations.
19 Low Voltage Network Protection A device used to prevent energy from flowing in one direction. Typically used in mesh network systems.
20 Low Voltage Power Conversion A device used to convert power type from AC to DC or DC to AC.
21 Low Voltage Power Factor Correcting A device used in the correction of the power factor of AC energy.
22 Low Voltage Service A service location or load point used in the delivery of low voltage power, frequently thought of as a meter location.
23 Low Voltage Switch A switch used to control the flow of energy.
24 Low Voltage Transformer Transformer devices represent a single electrical transformer. These devices can be by phase or polyphase.
44 Low Voltage Wire Connector A non-operable device used to connect and disconnect electrical wires
45 Low Voltage Regulator Voltage Regulator devices represent a device that is used in the regulation of voltage on the electric line.
46 Low Voltage Transformer Winding
61 Line Hardware
101 Aerial Bare Overhead Electric cables that are not shielded as Juction Objects. Using Junction Object reduces the storage of the row in the network index.
102 Aerial Covered Overhead Electric cables that are shielded to prevent arcing as Juction Objects. Using Junction Object reduces the storage of the row in the network index.
104 Busbar Solid non-flexible conductors, typically found in stations as Juction Objects. Using Junction Object reduces the storage of the row in the network index.
105 Underground Underground Conductor Cables as Juction Objects. Using Junction Object reduces the storage of the row in the network index.
106 Neutral Electric conductors used as Neutral as Juction Objects. Using Junction Object reduces the storage of the row in the network index.
107 Ground Wire Electric conductors used to connect to grounds as Juction Objects. Using Junction Object reduces the storage of the row in the network index.
108 Submarine Electric conductors used in under water situations as Juction Objects. Using Junction Object reduces the storage of the row in the network index.
109 Connector A feature used to connect non-spatial junction features as Juction Objects. Using Junction Object reduces the storage of the row in the network index.
49 High Voltage Tap Changer
50 Medium Voltage Tap Changer
62 Conductor Configuration
Subtype: Unknown
The Unknown asset group in the ElectricJunctionObject class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 UtilityNetwork_5_UnknownAssetType False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT False
phasechange User Assigned Phases SHORT True
phasessummer Summer Configuration Phases SHORT False
phaseswinter Winter Configuration Phases SHORT False
phasesplan Planned Phases SHORT False
phasesenergized Phases Energized SHORT 0 Electric_Phase_Attribution_All True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT True
grounding Grounding SHORT True
nominalvoltage Nominal Voltage (L-L) LONG True
nominalvoltagelg Nominal Voltage (L-G) LONG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG True
maxoperatingvoltage Maximum Operating Voltage LONG True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Unknown: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Ground
A junction used as a Ground, such as a Ground Rod
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Ground False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT False
phasechange User Assigned Phases SHORT True
phasessummer Summer Configuration Phases SHORT False
phaseswinter Winter Configuration Phases SHORT False
phasesplan Planned Phases SHORT False
phasesenergized Phases Energized SHORT 0 Electric_Phase_Attribution_All True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_Ground_Type True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT True
nominalvoltage Nominal Voltage (L-L) LONG True
nominalvoltagelg Nominal Voltage (L-G) LONG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG True
maxoperatingvoltage Maximum Operating Voltage LONG True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Ground: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Ground Unknown type of Ground. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
31 Bound Single terminal ['Asset Functional', 'E:Ground'] NONE DO_NOT_SPLIT END_VERTEX
32 Rod Single terminal ['Asset Functional', 'E:Ground'] NONE DO_NOT_SPLIT END_VERTEX
33 Voltage Grid Single terminal ['Asset Functional', 'E:Ground'] NONE DO_NOT_SPLIT END_VERTEX
34 Stray Voltage Isolator Single terminal ['Asset Functional', 'E:Ground'] NONE DO_NOT_SPLIT END_VERTEX
35 Grounding Switch Single terminal ['Asset Functional', 'E:Ground'] NONE DO_NOT_SPLIT END_VERTEX
36 Cross Bond Single terminal ['Asset Functional', 'E:Ground'] NONE DO_NOT_SPLIT END_VERTEX
37 Ground Plate Single terminal ['Asset Functional', 'E:Ground'] NONE DO_NOT_SPLIT END_VERTEX
38 Ground Joint Single terminal ['Asset Functional', 'E:Ground'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Insulating Equipment
Arrester devices represent over voltage protective equipment.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_High_Voltage_Arrester False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_High_Voltage_Arrester_Design True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_High_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_Discharge_Current True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG Electric_High_Voltage_Impulse True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: High Voltage Insulating Equipment: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Arrester An arrester used unknown situations in the high voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
21 Indoor Arrester HV An arrester used in indoor situations in the high voltage system Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
22 Line Arrester HV An arrester used in aerial situations in the high voltage system Single terminal ['Asset Functional', 'E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
23 Station Arrester HV An arrester used inside stations in the high voltage system Single terminal ['Asset Functional', 'E:Station'] NONE DO_NOT_SPLIT END_VERTEX
24 Indoor Insulator HV Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
25 Line Insulator HV Single terminal ['Asset Functional', 'E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
26 Station Insulator HV Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Control Unit
A electronic controller used to control the state of equipment used in high voltage systems, such as switches.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_High_Voltage_Control_Unit False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_Closing_Mode True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_High_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE Electric_Temperature_F True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: High Voltage Control Unit: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Control Unit Unknown type of High Voltage Control Unit. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
41 Capacitor HV A device used to control a capacitor in the high voltage system Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
42 Switch and Breaker HV A controller used with high voltage switches and breakers. Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
43 Voltage Regulator HV A device used to control a regulator in the high voltage system Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Fuse
A device used to protect the system from over current conditions, such as faults.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_High_Voltage_Fuse False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_High_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT Electric_Tap_Change_Percent True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT Electric_Device_Operation True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: High Voltage Fuse: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Fuse Unknown type of High Voltage Fuse. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
581 AC Station Disconnect Fuse HV An AC Fuse found in a station that is also used as a disconnect switch Single terminal ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
582 AC Station Load Break Fuse HV An AC Fuse found in a station that is also used as a disconnect switch Single terminal ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Station', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
583 AC Load Break Disconnect Fuse HV A AC Fuse that can break load and be used as a Disconnect Single terminal ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
584 AC Load Break Fuse HV - Controller A AC Fuse that can break load Circuit Breaker Directional ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
585 AC Disconnect Fuse HV - Controller A AC Fuse used as a Disconnect device that is also a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
586 AC Load Break Disconnect Fuse HV - Controller A AC Fuse that can break load and be used as a Disconnect, also a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Generation
A generation facility, such as a group or a single turbine, used in the generation of high volume watts.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_High_Voltage_Generation False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_Generator_Control_Type True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE Electric_Impedance_Range True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT Electric_Generation_ANSI_Group_Code True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_High_Voltage_Generate_Watts True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG Electric_High_Voltage_Generate_Watts True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: High Voltage Generation: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Generation Unknown type of High Voltage Generation. Single terminal ['Asset Functional', 'E:Generation'] NONE DO_NOT_SPLIT END_VERTEX
61 Battery HV A high wattage Battery. Single terminal ['Asset Functional', 'E:Generation', 'E:Generation - Storage'] NONE DO_NOT_SPLIT END_VERTEX
62 Biomass HV A high Wattage Biomass Generator. Single terminal ['Asset Functional', 'E:Generation'] NONE DO_NOT_SPLIT END_VERTEX
63 Coal HV A high Wattage Generator using Coal. Single terminal ['Asset Functional', 'E:Generation'] NONE DO_NOT_SPLIT END_VERTEX
64 Gas Turbine HV A high Wattage Generator using Gas Turbine. Single terminal ['Asset Functional', 'E:Generation'] NONE DO_NOT_SPLIT END_VERTEX
65 Geothermal HV A high Wattage Generator using Geothermal energy. Single terminal ['Asset Functional', 'E:Generation'] NONE DO_NOT_SPLIT END_VERTEX
66 Hydro HV A high Wattage Generator using Hydro. Single terminal ['Asset Functional', 'E:Generation'] NONE DO_NOT_SPLIT END_VERTEX
67 Nuclear HV A high Wattage Generator using Nuclear. Single terminal ['Asset Functional', 'E:Generation'] NONE DO_NOT_SPLIT END_VERTEX
68 Photovoltaic Solar HV A high Wattage Generator using Photovoltaic solar. Single terminal ['Asset Functional', 'E:Generation'] NONE DO_NOT_SPLIT END_VERTEX
69 Thermal Solar HV A high Wattage Generator using Thermal solar. Single terminal ['Asset Functional', 'E:Generation'] NONE DO_NOT_SPLIT END_VERTEX
70 Wind HV A high Wattage Generator using Wind. Single terminal ['Asset Functional', 'E:Generation'] NONE DO_NOT_SPLIT END_VERTEX
71 AC Wave HV A Ocean Wave Generation station providing power to the high voltage system Single terminal ['Asset Functional', 'E:Generation'] NONE DO_NOT_SPLIT END_VERTEX
72 Generator HV A high voltage energy storage device frequently installed at residences. Single terminal ['Asset Functional', 'E:Generation'] NONE DO_NOT_SPLIT END_VERTEX
73 Interconnect HV Single terminal ['Asset Functional', 'E:Generation'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Line Monitor and Relay
Line monitors are frequently used in conjunction with SCADA systems to monitor system conditions.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_High_Voltage_Line_Monitor_and_Relay False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_High_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT Electric_RTU_Data_Type True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: High Voltage Line Monitor and Relay: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Line Monitor and Relay Unknown type of High Voltage Line Monitor and Relay. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
80 Fault Indicator HV A Fault indicator used in high voltage systems. Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
81 Instrument Transformer HV An Instrument Transformer used in high voltage systems. Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
82 Load Monitor HV A load monitoring sensor used in high voltage systems. Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
83 Relay HV A relay used in high voltage systems. Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Power Conversion
A device used to convert power type from AC to DC or DC to AC.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_High_Voltage_Power_Conversion False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration_Transformer_Regulator True
nominalvoltage Nominal Voltage (L-L) LONG Electric_High_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE Electric_Device_Resistance_Range True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG Electric_High_Voltage_Generate_Watts True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: High Voltage Power Conversion: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Power Conversion A device that converts power of unknown type in the high voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
101 Inverter HV A device that converts input energy from DC to output energy of AC in the high voltage system Single terminal ['Asset Functional', 'E:Power Conversion'] NONE DO_NOT_SPLIT END_VERTEX
102 Rectifier HV A device that converts input energy from AC to output energy of DC in the high voltage system Single terminal ['Asset Functional', 'E:Power Conversion'] NONE DO_NOT_SPLIT END_VERTEX
103 Bidirectional HV A power conversion device used to convert AC to DC or DC to AC in the high voltage system Single terminal ['Asset Functional', 'E:Power Conversion'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Power Factor Correcting
A device used in the correction of the power factor of AC energy.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_High_Voltage_Power_Factor_Correcting False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_Power_Factor_Correcting_Type True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_High_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE Electric_Device_Resistance_Range True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT Electric_Capacitory_Type True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE Electric_Temperature_F True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_High_Voltage_KVAR True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG Electric_High_Voltage_Load_Loss True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: High Voltage Power Factor Correcting: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Power Factor Correcting A power factor correcting device of unknown type in the high voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
121 AC Capacitor HV A capacitor used in the AC high voltage system Single terminal ['Asset Functional', 'E:Reactive Power'] NONE DO_NOT_SPLIT END_VERTEX
122 AC Wave Trap HV A Wave Trap used for Power Line Communications in high voltage systems. Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
123 AC Reactor HV A reactor used in the AC high voltage system Single terminal ['Asset Functional', 'E:Reactive Power'] NONE DO_NOT_SPLIT END_VERTEX
124 DC Capacitor HV A capacitor used in the DC high voltage system Single terminal ['Asset Functional', 'E:Reactive Power'] NONE DO_NOT_SPLIT END_VERTEX
125 DC Reactor HV A reactor used in the DC high voltage system Single terminal ['Asset Functional', 'E:Reactive Power'] NONE DO_NOT_SPLIT END_VERTEX
126 Synchronous Condenser HV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Regulator
Voltage Regulator devices represent a device that is used in the regulation of voltage on the electric line. It can be a single or polyphase device.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_High_Voltage_Regulator False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_High_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE Electric_Tap_Maximum_Change True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE Electric_Load_Tap_Bandwidth True
maximumboost Maximum Voltage Boost DOUBLE Electric_Buck_Boost_Rate True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE Electric_Impedance_Range True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT Yes_No True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_High_Voltage_Regulator_VA True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG Electric_High_Voltage_Regulator_VA True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG Electric_High_Voltage_Regulator_VA True
loadtapchangepercent Load Tap Change (%) SHORT Electric_Tap_Change_Percent True
noloadloss Losses, No Load Loss LONG Electric_High_Voltage_Load_Loss True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE Electric_Regulator_Maximum_Buck_Boost True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT Electric_Voltage_Bandwidth True
loadtapchangerupperbandwidth Diameter/Width DOUBLE Electric_Tap_Maximum_Change True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE Electric_Tap_Maximum_Change True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT Electric_Transformer_Cooling True
inparallel In Parallel SHORT Yes_No True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: High Voltage Regulator: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Regulator A voltage regulating device used in the high voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
171 AC Single Phase HV An Single Phase Voltage Regulator used in High Voltage AC system Single terminal ['Asset Functional', 'E:Voltage Regulation'] NONE DO_NOT_SPLIT END_VERTEX
172 AC Three Phase HV A three phase voltage regulator used in the high voltage AC system Single terminal ['Asset Functional', 'E:Voltage Regulation'] NONE DO_NOT_SPLIT END_VERTEX
173 DC Regulator HV An Voltage Regulator used in High Voltage DC system Single terminal ['Asset Functional', 'E:Voltage Regulation'] NONE DO_NOT_SPLIT END_VERTEX
174 Frequency Converter HV A device that converts a current with one frequency to a current with another frequency in the high voltage AC system Single terminal ['Asset Functional', 'E:Voltage Regulation'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Service
A service location or load point used in the delivery of high voltage power, frequently thought of as a meter location.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_High_Voltage_Service False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_High_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG Electric_High_Voltage_Load_Loss True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: High Voltage Service: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Service A unknown type of service metering point in the high voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
161 AC Metering HV A metering device used in the high voltage AC system Single terminal ['Asset Functional', 'E:Load', 'E:Load - Commercial', 'E:Load - Customer', 'E:Load - Industrial'] NONE DO_NOT_SPLIT END_VERTEX
162 DC Metering HV A metering device used in the high voltage DC system Single terminal ['Asset Functional', 'E:Load', 'E:Load - Commercial', 'E:Load - Customer', 'E:Load - Industrial'] NONE DO_NOT_SPLIT END_VERTEX
163 High Voltage Premise HV A service location of a customer connected to the high voltage system Single terminal ['Asset Functional', 'E:Load', 'E:Load - Commercial', 'E:Load - Customer'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Switch
A switch used to control the flow of energy.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_High_Voltage_Switch False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Device_Switch_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_High_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT Yes_No True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_High_Voltage_Maximum_Current True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG Electric_High_Voltage_Maximum_Continuous_Current True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT Electric_Device_Operation True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: High Voltage Switch: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Switch A unknown switch type used in the high voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
181 AC Circuit Breaker HV A circuit break used in the high voltage AC system Single terminal ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
182 AC Disconnect HV A disconnect switch used in the high voltage AC system Single terminal ['Asset Functional', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
183 AC Switchgear HV An mechanical switch gear used in the high voltage AC system Single terminal ['Asset Functional', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
184 DC Circuit Breaker HV A circuit breaker device used to dynamically control the flow of energy in a high voltage substation using DC energy. Single terminal ['Asset Functional', 'E:Protective', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
185 DC Disconnect HV A disconnecting switch used in the high voltage DC system Single terminal ['Asset Functional', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
186 DC Switchgear HV A mechanical switchgear used in the high voltage DC system Single terminal ['Asset Functional', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
187 AC Bus Tie Breaker HV A switch used to connect busbar in a station in the high voltage AC system Single terminal ['Asset Functional', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
188 DC Bus Tie Breaker HV A switch used to connect busbar in a station in the high voltage DC system Single terminal ['Asset Functional', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
189 AC Disconnect - Grounded HV A disconnect switch that can be grounded when open used in the high voltage AC system Single terminal ['Asset Functional', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
190 AC Recloser HV A mechanical self closing switch used in the high voltage AC system Single terminal ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
191 AC Circuit Breaker HV - Controller Circuit Breaker Directional ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
192 AC Station Load Break Disconnect HV A station located load breaking or disconnecting switch used in the high voltage AC system Single terminal ['Asset Functional', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
193 AC Station Load Break Disconnect HV - Controller A station located load breaking or disconnecting switch used in the high voltage AC system that can also be used as a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
194 DC Circuit Breaker HV - Controller A circuit breaker device used to dynamically control the flow of energy in a high voltage substation using DC energy, also used as a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
195 AC Disconnect HV - Controller A disconnect switch used in the high voltage AC system that can also be used as a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
196 AC Grounding HV A switch, that when opened can provide ground protection used in the high voltage AC system Single terminal ['Asset Functional', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
197 AC Thyristor HV Circuit Breaker Directional ['Asset Functional', 'E:Protective', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
198 DC Thyristor HV Circuit Breaker Directional ['Asset Functional', 'E:Protective', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
199 AC Transfer Switch HV Single terminal ['Asset Functional', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Transformer
Transformer devices represent a single electrical transformer. These devices can be by phase or polyphase.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_High_Voltage_Transformer False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondarygrounding Secondary Winding Ground SHORT Electric_Ground_Configuration True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
tertiarygrounding Tertiary Winding Ground SHORT Electric_Ground_Configuration True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE Electric_Tap_Maximum_Change True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE Electric_Load_Tap_Bandwidth True
maximumboost Maximum Voltage Boost DOUBLE Electric_Buck_Boost_Rate True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE Electric_Impedance_Range True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT Electric_XFR_Type True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE Electric_Temperature_F True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_High_Voltage_Transformer_VA True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG Electric_High_Voltage_Transformer_VA True
loadtapchangepercent Load Tap Change (%) SHORT Electric_Tap_Change_Percent True
noloadloss Losses, No Load Loss LONG Electric_High_Voltage_Load_Loss True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE Electric_Load_Tap_Bandwidth True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE Electric_Tap_Maximum_Change True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT Electric_Transformer_Cooling True
inparallel In Parallel SHORT Yes_No True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: High Voltage Transformer: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Transformer A transformer of unknown type used in the high voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
201 AC Single Phase - HV->MV An AC Single Phase Power Transformer converting from High Voltage to Medium Voltage Single terminal ['Asset Functional', 'E:Load', 'E:Transformer - Power', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
202 AC Three Phase - HV->MV An AC Three Phase Power Transformer converting from high voltage to medium voltage Single terminal ['Asset Functional', 'E:Load', 'E:Transformer - Power', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
203 DC Power - HV->HV A voltage transformer used inside a substation to change the voltage for DC energy in the high voltage system Single terminal ['Asset Functional', 'E:Load', 'E:Transformer - Power', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
204 Grounding Transformer - HV->MV A specialized transformer for changing the system grounding between the high and medium voltage systems Single terminal ['Asset Functional', 'E:Load', 'E:Transformer - Power', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
205 Station - HV->MV A station located transformer used to convert power from high voltage to medium voltage Single terminal ['Asset Functional', 'E:Load', 'E:Station', 'E:Transformer - Power', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
206 Station Three Winding - HV->HV-HV A three winding transformer that converts an incoming high voltage current to two different output high voltages Single terminal ['Asset Functional', 'E:Load', 'E:Station', 'E:Transformer - Power', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
207 Station Three Winding - HV->HV-MV A three winding transformer that converts an incoming high voltage current to two different voltages, one high and one medium Single terminal ['Asset Functional', 'E:Load', 'E:Station', 'E:Transformer - Power', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
208 Phase Control - HV->HV A transformer that is used to step down the voltage to power the control devices of a circuit or machine in the high voltage system Single terminal ['Asset Functional', 'E:Load'] NONE DO_NOT_SPLIT END_VERTEX
209 Station Three Winding - HV->HV-LV A three winding transformer that converts an incoming high voltage current to two different voltages, one high and one low Single terminal ['Asset Functional', 'E:Load', 'E:Station', 'E:Transformer - Power', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
210 Station Step Up - MV->HV A transformer used to increase the voltage from medium Voltage levels to high Voltage levels that can be a subnetwork controller Single terminal ['Asset Functional', 'E:Load', 'E:Station', 'E:Transformer - Power', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
211 Station Step - HV->HV A station located transformer used to convert power from high voltage to a different high voltage Single terminal ['Asset Functional', 'E:Load', 'E:Station', 'E:Transformer - Power', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
212 Station Three Winding - HV->MV-MV Single terminal ['Asset Functional', 'E:Load', 'E:Station', 'E:Transformer - Power', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
213 Station Three Winding - HV->MV-LV Single terminal ['Asset Functional', 'E:Load', 'E:Station', 'E:Transformer - Power', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Transformer Winding
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT Asset_Type_Electric_JunctionObject_High_Voltage_Transformer_Winding False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_High_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_High_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_High_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT True
grounding Grounding SHORT True
nominalvoltage Nominal Voltage (L-L) LONG True
nominalvoltagelg Nominal Voltage (L-G) LONG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_High_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT Electric_Tap_Change_Percent True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: High Voltage Transformer Winding: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Transformer Winding Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
871 AC Transformer Winding HV Transformer Winding ['Asset Functional', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
872 DC Transformer Winding HV Transformer Winding ['Asset Functional', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Insulating Equipment
A device used to protect equipment from over voltage conditions such as lighting strikes.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Medium_Voltage_Arrester False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_Medium_Voltage_Arrester_Design True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_Discharge_Current True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG Electric_Discharge_Current True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Medium Voltage Insulating Equipment: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Arrester An arrester used unknown situations in the medium voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
481 Elbow Arrester MV An arrester used in connect to bushings in pad mounted equipment in the medium voltage system Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
482 Line Arrester MV An arrester used in aerial situations in the medium voltage system Single terminal ['Asset Functional', 'E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
483 Station Arrester MV An arrester used inside stations in the medium voltage system Single terminal ['Asset Functional', 'E:Station'] NONE DO_NOT_SPLIT END_VERTEX
484 Underground Insulator MV Single terminal ['Asset Functional', 'E:Cable - Underground'] NONE DO_NOT_SPLIT END_VERTEX
485 Line Insulator MV Single terminal ['Asset Functional', 'E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
486 Station Insulator MV Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Circuit Breaker
A type of switch used as a network controller or start of a circuit or feeder.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Medium_Voltage_Circuit_Breaker False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE Electric_Impedance_Range True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT Yes_No True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_Medium_Voltage_Fuse_Continuous_Amps True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG Electric_Medium_Voltage_Fuse_Interrupting_Amps True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT Electric_Device_Operation True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Medium Voltage Circuit Breaker: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Circuit Breaker a mechanical switching device of unknown type in the medium voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
501 Isolator Switch MV mechanical switch that is used in electric circuits and devices with the main function of effectively isolating two different parts in the medium voltage system Single terminal ['Asset Functional', 'E:Station', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
502 Single Phase Circuit Breaker MV A mechanical switching device used on a single phase in the medium voltage system Single terminal ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Station', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
503 Three Phase Circuit Breaker MV A mechanical switching device used on a three phases in the medium voltage system Single terminal ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Station', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
512 Single Phase Circuit Breaker MV - Controller A mechanical switching device used on a single phase in the medium voltage system that can also be a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Reclosing', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
513 Three Phase Circuit Breaker MV - Controller A mechanical switching device used on a three phases in the medium voltage system that can also be a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Reclosing', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
515 Network Protector MV A specialized switch that disconnects the circuit from the main system when power starts flows in the reverse direction in the medium voltage system Single terminal ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Switch - Circuit Breaker', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Control Unit
A electronic controller used to control the state of equipment used in medium voltage systems, such as switches.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Medium_Voltage_Control_Unit False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_Closing_Mode True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE Electric_Temperature_F True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Medium Voltage Control Unit: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Control Unit A device used to control unknown equipment types in the medium voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
521 Capacitor MV A device used to control a capacitor in the medium voltage system Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
522 Circuit Breaker MV A device used to control a circuit breaker in the medium voltage system Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
523 Recloser MV A device used to control a recloser in the medium voltage system Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
524 Transfer Switch Controller MV A device used to control a transfer switch in the medium voltage system Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
525 Regulator MV A device used to control a regulator in the medium voltage system Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Elbow
A device that can be opened, like a switch, but is used to connect underground cables to bushings on pad mounted or underground equipment, such as transformers. Since they can be opened, they can have similar operational behavior as to a switch.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Medium_Voltage_Elbow False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_Medium_Voltage_Fuse_Continuous_Amps True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG Electric_Medium_Voltage_Fuse_Interrupting_Amps True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Medium Voltage Elbow: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Elbow Unknown type of Medium Voltage Elbow. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
2 AC Underground Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
5 AC Underground - Controller Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
541 Load Break Feedthru MV A medium voltage underground load break feedthru. Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
542 Load Break Junction MV A medium voltage underground load break junction. Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
543 Single Phase Dead Break MV A medium voltage single phase dead break elbow. Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
544 Single Phase Load Break MV A medium voltage single phase load break elbow. Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
545 Three Phase Dead Break MV A medium voltage three phase dead break elbow. Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
546 Three Phase Load Break MV A medium voltage three phase load break elbow. Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Fuse
A device used to protect the system from over current conditions, such as faults.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Medium_Voltage_Fuse False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_Medium_Voltage_Fuse_Rating True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_Medium_Voltage_Fuse_Continuous_Amps True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG Electric_Medium_Voltage_Fuse_Interrupting_Amps True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT Electric_Device_Operation True
operatingmechanism Field Operating Mechanism SHORT Electric_Device_OperatingMechanism True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Medium Voltage Fuse: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Fuse Unknown type of Medium Voltage Fuse. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
1 AC Overhead Single terminal ['E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
2 AC Underground Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
3 AC Station Single terminal ['E:Station'] NONE DO_NOT_SPLIT END_VERTEX
4 AC Overhead - Controller Single terminal ['E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
5 AC Underground - Controller Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
6 AC Station - Controller Single terminal ['E:Station'] NONE DO_NOT_SPLIT END_VERTEX
561 Bayonet Fuse MV A medium voltage bayonet fuse used in underground equipment. Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
562 Fault Limiter Fuse MV A medium voltage fault limiting device. Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
563 Indoor Fuse MV A medium voltage fuse for confined areas. Single terminal ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
564 Overhead Cutout Disconnect Fuse MV A medium voltage overhead disconnect cutout fuse holder. Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
565 Overhead Cutout Load Break Fuse MV A medium voltage overhead load breaking cutout fuse holder. Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
566 Overhead Cutout Sectionalizer Fuse MV A medium voltage overhead load breaking cutout with a sectionalizer. Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'E:Switch - Sectionalizing'] NONE DO_NOT_SPLIT END_VERTEX
567 Overhead Cutout Solid Blade Fuse MV An Overhead cutout that contains a solid copper blade. One per phase. Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
568 Cabinet Fuse MV A Fuse used in pad mounted equipment. One per phase. Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
569 Underground Fuse MV A underground fuse holder. Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
570 Underground Disconnect Fuse MV A underground disconnect fuse holder. Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
571 Underground Load Break Fuse MV A underground load breaking fuse holder. Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
572 Overhead Cutout Load Break Disconnect Fuse MV A overhead cutout used to house a fuse that can also be used as a disconnect switch in the medium voltage system Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
573 Overhead Cutout Load Break Fuse MV - Controller A medium voltage overhead load breaking cutout fuse holder, also used as a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
574 Overhead Cutout Disconnect Fuse MV - Controller A medium voltage overhead disconnect cutout fuse holder, also used as a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
575 Overhead Cutout Load Break Disconnect Fuse MV - Controller A overhead cutout used to house a fuse that can also be used as a disconnect switch in the medium voltage system that can be used as a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Generation
A generation facility, such as a group or a single turbine, used in the generation of medium volumes of watts, such as solar farms .
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Medium_Voltage_Generation False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT Electric_Medium_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_Generator_Control_Type True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE Electric_Impedance_Range True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT Electric_Generation_ANSI_Group_Code True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Medium Voltage Generation: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Generation Unknown type of Medium Voltage Generation. Single terminal ['Asset Functional', 'E:Generation'] NONE DO_NOT_SPLIT END_VERTEX
110 AC Wave MV A Ocean Wave Generation station providing power to the medium voltage system Single terminal ['Asset Functional', 'E:Generation', 'E:Generation - Distributed'] NONE DO_NOT_SPLIT END_VERTEX
111 Battery MV A medium wattage Battery. Single terminal ['Asset Functional', 'E:Generation', 'E:Generation - Distributed', 'E:Generation - Storage'] NONE DO_NOT_SPLIT END_VERTEX
112 Biomass MV A power generation device connected to the medium voltage system that uses biomass as fuel Single terminal ['Asset Functional', 'E:Generation', 'E:Generation - Distributed'] NONE DO_NOT_SPLIT END_VERTEX
113 Generator MV A medium voltage energy storage device frequently installed at residences. Single terminal ['Asset Functional', 'E:Generation', 'E:Generation - Distributed'] NONE DO_NOT_SPLIT END_VERTEX
114 Gas Turbine MV A medium Wattage Generator using Gas Turbine. Single terminal ['Asset Functional', 'E:Generation', 'E:Generation - Distributed'] NONE DO_NOT_SPLIT END_VERTEX
115 Geothermal MV A medium Wattage Generator using Geothermal energy. Single terminal ['Asset Functional', 'E:Generation', 'E:Generation - Distributed'] NONE DO_NOT_SPLIT END_VERTEX
116 Hydro MV A medium Wattage Generator using Hydro. Single terminal ['Asset Functional', 'E:Generation', 'E:Generation - Distributed'] NONE DO_NOT_SPLIT END_VERTEX
117 Wind MV A medium wattage Generator using Wind. Single terminal ['Asset Functional', 'E:Generation', 'E:Generation - Distributed'] NONE DO_NOT_SPLIT END_VERTEX
118 Photovoltaic Solar MV A medium\ Wattage Generator using Photovoltaic solar. Single terminal ['Asset Functional', 'E:Generation', 'E:Generation - Distributed'] NONE DO_NOT_SPLIT END_VERTEX
119 Thermal Solar MV A medium wattage Generator using Thermal solar. Single terminal ['Asset Functional', 'E:Generation', 'E:Generation - Distributed'] NONE DO_NOT_SPLIT END_VERTEX
120 Interconnect MV Single terminal ['Asset Functional', 'E:Generation'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Line Monitor and Relay
Line monitors are frequently used in conjunction with SCADA systems to monitor system conditions.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Medium_Voltage_Line_Monitor_and_Relay False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT Electric_RTU_Data_Type True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Medium Voltage Line Monitor and Relay: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Line Monitor and Relay Unknown type of Medium Voltage Line Monitor and Relay. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
601 Fault Indicator MV A Fault indicator used in medium voltage systems. Single terminal ['Asset Functional', 'Subnetwork Tap'] NONE DO_NOT_SPLIT END_VERTEX
602 Instrument Transformer MV An Instrument Transformer used in medium voltage systems. Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
603 Programmable Logic Unit MV A SCADA device used to control equipment. Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
604 Remote Terminal Unit MV A SCADA device used to communicate and possibly control equipment. Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
605 SCADA Load Monitor MV A load monitoring sensor used in medium voltage systems. Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
606 SCADA Weather Station MV A weather station used in the medium voltage stations. Single terminal ['Asset Functional', 'E:Station'] NONE DO_NOT_SPLIT END_VERTEX
607 Relay MV A relay used in medium voltage systems. Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Motor and Pump
Pumps and motors, typically used for waste water or storm water management, considered a critical asset during major outage events.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Medium_Voltage_Motor_and_Pump False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_Motor_Type True
manufacturer Manufacturer SHORT True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE Electric_Impedance_Range True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT Electric_Generation_ANSI_Group_Code True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Medium Voltage Motor and Pump: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Motor and Pump Unknown type of Medium Voltage Motor and Pump. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
621 Single Phase Motor MV A medium voltage single phase motor. Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
622 Single Phase Pump MV A medium voltage single phase pump and motor. Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
623 Three Phase Motor MV A medium voltage three phase motor. Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
624 Three Phase Pump MV A medium voltage three phase pump and motor. Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Power Conversion
A device used to convert power type from AC to DC or DC to AC.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Medium_Voltage_Power_Conversion False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondarygrounding Secondary Winding Ground SHORT Electric_Ground_Configuration True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE Electric_Device_Resistance_Range True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_Medium_Voltage_Load_Watts True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG Electric_Medium_Voltage_Load_Watts True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Medium Voltage Power Conversion: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Power Conversion A device that converts power of unknown type in the medium voltage system Single terminal ['E:Power Conversion'] NONE DO_NOT_SPLIT END_VERTEX
641 Single Phase Inverter MV A device that converts input energy from DC to output energy of AC in the medium voltage system Single terminal ['Asset Functional', 'E:Power Conversion'] NONE DO_NOT_SPLIT END_VERTEX
642 Single Phase Rectifier MV A device that converts input energy from AC to output energy of DC in the medium voltage system Single terminal ['Asset Functional', 'E:Power Conversion'] NONE DO_NOT_SPLIT END_VERTEX
643 Three Phase Inverter MV A device that converts input energy from DC to output energy of AC Three Phase in the medium voltage system Single terminal ['Asset Functional', 'E:Power Conversion'] NONE DO_NOT_SPLIT END_VERTEX
644 Three Phase Rectifier MV A device that converts input energy from three phase AC to output energy of DC in the medium voltage system Single terminal ['Asset Functional', 'E:Power Conversion'] NONE DO_NOT_SPLIT END_VERTEX
645 Single Phase Bidirectional MV A power conversion device used to convert AC to DC or DC to AC in the medium voltage system Single terminal ['Asset Functional', 'E:Power Conversion'] NONE DO_NOT_SPLIT END_VERTEX
646 Three Phase Bidirectional MV A power conversion device used to convert three phase AC to DC or DC to AC three phase in the medium voltage system Single terminal ['Asset Functional', 'E:Power Conversion'] NONE DO_NOT_SPLIT END_VERTEX
647 Wave Trap MV Equipment used to prevent high frequency carrier signals of power line communication to unwanted destinations, medium voltage system Single terminal ['Asset Functional', 'E:Power Conversion'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Power Factor Correcting
A device used in the correction of the power factor of AC energy.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Medium_Voltage_Power_Factor_Correcting False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_Configuration_Type True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration_Transformer_Regulator True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT Electric_Capacitory_Type True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE Electric_Temperature_F True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_Medium_Voltage_KVAR True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG Electric_Medium_Voltage_KVAR True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG Electric_Medium_Voltage_Load_Loss True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Medium Voltage Power Factor Correcting: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Power Factor Correcting A power factor correcting device of unknown type in the medium voltage system Single terminal ['E:Reactive Power'] NONE DO_NOT_SPLIT END_VERTEX
1 AC Overhead Single terminal ['E:Reactive Power'] NONE DO_NOT_SPLIT END_VERTEX
2 AC Underground Single terminal ['E:Reactive Power'] NONE DO_NOT_SPLIT END_VERTEX
3 AC Station Single terminal ['E:Reactive Power', 'E:Station'] NONE DO_NOT_SPLIT END_VERTEX
4 AC Overhead - Controller Single terminal ['E:Reactive Power'] NONE DO_NOT_SPLIT END_VERTEX
5 AC Underground - Controller Single terminal ['E:Reactive Power'] NONE DO_NOT_SPLIT END_VERTEX
6 AC Station - Controller Single terminal ['E:Reactive Power', 'E:Station'] NONE DO_NOT_SPLIT END_VERTEX
661 Mobile Capacitor MV A capacitor mounted on a trailer used in the medium voltage system Single terminal ['Asset Functional', 'E:Reactive Power'] NONE DO_NOT_SPLIT END_VERTEX
664 Overhead Single Phase Capacitor MV A pole mounted single phase capacitor used in the medium voltage system Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Reactive Power', 'E:Switch - Load Break'] NONE DO_NOT_SPLIT END_VERTEX
665 Overhead Three Phase Capacitor MV A pole mounted three phase capacitor used in the medium voltage system Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Reactive Power', 'E:Switch - Load Break'] NONE DO_NOT_SPLIT END_VERTEX
666 Overhead Harmonic Filter MV A pole mounted harmonic filter used in the medium voltage system Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Switch - Load Break'] NONE DO_NOT_SPLIT END_VERTEX
667 Overhead Reactor MV A pole mounted reactor used in the medium voltage system Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Reactive Power', 'E:Switch - Load Break'] NONE DO_NOT_SPLIT END_VERTEX
668 Pad Mounted Single Phase Capacitor MV A pad mounted single phase capacitor used in the medium voltage system Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Reactive Power'] NONE DO_NOT_SPLIT END_VERTEX
669 Pad Mounted Three Phase Capacitor MV A pad mounted three phase capacitor used in the medium voltage system Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Reactive Power'] NONE DO_NOT_SPLIT END_VERTEX
671 Mobile Harmonic Filter MV A harmonic filter mounted on a trailer used in the medium voltage system Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
672 Mobile Reactor MV A reactor mounted on a trailer used in the medium voltage system Single terminal ['Asset Functional', 'E:Reactive Power'] NONE DO_NOT_SPLIT END_VERTEX
673 Pad Mounted Harmonic Filter MV A pad mounted harmonic filter used in the medium voltage system Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Reactive Power'] NONE DO_NOT_SPLIT END_VERTEX
674 Pad Mounted Reactor MV A pad mounted reactor used in the medium voltage system Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Reactive Power'] NONE DO_NOT_SPLIT END_VERTEX
675 Station Capacitor MV A capacitor used in the medium voltage system found in a station Single terminal ['Asset Functional', 'E:Reactive Power', 'E:Station'] NONE DO_NOT_SPLIT END_VERTEX
676 Station Harmonic Filter MV A harmonic filter used in the medium voltage system found in a station Single terminal ['Asset Functional', 'E:Station'] NONE DO_NOT_SPLIT END_VERTEX
677 Station Reactor MV A reactor used in the medium voltage system found in a station Single terminal ['Asset Functional', 'E:Reactive Power', 'E:Station'] NONE DO_NOT_SPLIT END_VERTEX
678 Synchronous Condenser MV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Regulator
Voltage Regulator devices represent a device that is used in the regulation of voltage on the electric line. It can be a single or polyphase device.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Medium_Voltage_Regulator False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration_Transformer_Regulator True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE Electric_Tap_Maximum_Change True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE Electric_Load_Tap_Bandwidth True
maximumboost Maximum Voltage Boost DOUBLE Electric_Buck_Boost_Rate True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE Electric_Impedance_Range True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT Electric_XFR_Type True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT Yes_No True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_Medium_Voltage_Regulator_VA True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG Electric_Medium_Voltage_Regulator_VA True
loadtapchangepercent Load Tap Change (%) SHORT Electric_Tap_Change_Percent True
noloadloss Losses, No Load Loss LONG Electric_Medium_Voltage_Load_Loss True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE Electric_Regulator_Maximum_Buck_Boost True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT Electric_Voltage_Bandwidth True
loadtapchangerupperbandwidth Diameter/Width DOUBLE Electric_Load_Tap_Bandwidth True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE Electric_Load_Tap_Bandwidth True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT Electric_Transformer_Cooling True
inparallel In Parallel SHORT Yes_No True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Medium Voltage Regulator: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Regulator A voltage regulating device used in the medium voltage system Single terminal ['E:Voltage Regulation'] NONE DO_NOT_SPLIT END_VERTEX
1 AC Overhead Single terminal ['E:Cable - Overhead', 'E:Voltage Regulation'] NONE DO_NOT_SPLIT END_VERTEX
2 AC Underground Single terminal ['E:Voltage Regulation'] NONE DO_NOT_SPLIT END_VERTEX
3 AC Station Single terminal ['E:Station', 'E:Voltage Regulation'] NONE DO_NOT_SPLIT END_VERTEX
4 AC Overhead - Controller Single terminal ['E:Cable - Overhead', 'E:Voltage Regulation'] NONE DO_NOT_SPLIT END_VERTEX
5 AC Underground - Controller Single terminal ['E:Voltage Regulation'] NONE DO_NOT_SPLIT END_VERTEX
681 Overhead Single Phase VR MV An single phase pole mounted voltage regulator used in high voltage AC system Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Switch - Load Break', 'E:Voltage Regulation'] NONE DO_NOT_SPLIT END_VERTEX
683 Overhead Three Phase VR MV An three phase pole mounted voltage regulator used in high voltage AC system Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Switch - Load Break', 'E:Voltage Regulation'] NONE DO_NOT_SPLIT END_VERTEX
685 Pad Mounted Single Phase VR MV An single phase pad mounted voltage regulator used in high voltage AC system Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Voltage Regulation'] NONE DO_NOT_SPLIT END_VERTEX
687 Pad Mounted Three Phase VR MV An three phase pad mounted voltage regulator used in high voltage AC system Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Voltage Regulation'] NONE DO_NOT_SPLIT END_VERTEX
688 Frequency Converter MV A device that converts a current with one frequency to a current with another frequency in the medium voltage AC system Single terminal ['Asset Functional', 'E:Voltage Regulation'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Service
A service location or load point used in the delivery of medium voltage power, frequently thought of as a primary meter.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Medium_Voltage_Service False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG Electric_Medium_Voltage_Load_Loss True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Medium Voltage Service: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Service A unknown type of service metering point in the medium voltage system Single terminal ['E:Load', 'E:Load - Commercial', 'E:Load - Customer', 'E:Load - Industrial'] NONE DO_NOT_SPLIT END_VERTEX
701 Primary Meter - Industrial Customer MV A metering device used for a industrial customer in the medium voltage system Single terminal ['Asset Functional', 'E:Load', 'E:Load - Commercial', 'E:Load - Customer', 'E:Load - Industrial'] NONE DO_NOT_SPLIT END_VERTEX
702 Primary Meter - Utility Customer MV A metering device used for a utility customer in the medium voltage system Single terminal ['Asset Functional', 'E:Load', 'E:Load - Commercial', 'E:Load - Customer', 'E:Load - Utility'] NONE DO_NOT_SPLIT END_VERTEX
703 Primary Meter Circuit Source MV A metering device used for a utility customer in the medium voltage system that is also a subnetwork controller Single terminal ['Asset Functional', 'E:Load', 'E:Load - Commercial', 'E:Load - Customer'] NONE DO_NOT_SPLIT END_VERTEX
704 Medium Voltage Premise MV A service location of a customer connected to the medium voltage system Single terminal ['Asset Functional', 'E:Load', 'E:Load - Commercial', 'E:Load - Customer'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Recloser
A self reclosing switch
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Medium_Voltage_Recloser False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT Yes_No True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_Medium_Voltage_Fuse_Continuous_Amps True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG Electric_Medium_Voltage_Fuse_Continuous_Amps True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT Electric_Device_Operation True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Medium Voltage Recloser: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Recloser Unknown type of Medium Voltage Recloser. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
1 AC Overhead Single terminal ['E:Cable - Overhead', 'E:Switch - Reclosing'] NONE DO_NOT_SPLIT END_VERTEX
2 AC Underground Single terminal ['E:Switch - Reclosing'] NONE DO_NOT_SPLIT END_VERTEX
4 AC Overhead - Controller Single terminal ['E:Cable - Overhead', 'E:Switch - Reclosing'] NONE DO_NOT_SPLIT END_VERTEX
5 AC Underground - Controller Single terminal ['E:Switch - Reclosing'] NONE DO_NOT_SPLIT END_VERTEX
730 Overhead Single Phase Recloser MV A medium voltage single phase reclosing switch. Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
734 Overhead Three Phase Recloser MV - Controller A medium voltage three phase reclosing switch where all three phases are operated the same way at all times, also used as a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Reclosing', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
738 Pad Mounted Three Phase Recloser MV - Controller A medium voltage three phase reclosing switch where all three phases are operated the same way at all times, also used as a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Reclosing', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
744 Overhead Three Phase Recloser MV A medium voltage three phase reclosing switch where all three phases are operated the same way at all times. Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
747 Pad Mounted Single Phase Recloser MV A medium voltage single phase reclosing switch. Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
748 Pad Mounted Three Phase Recloser MV A medium voltage three phase reclosing switch where all three phases are operated the same way at all times. Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Sectionalizer
A sectionlizing switch
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Medium_Voltage_Sectionalizer False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT Yes_No True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT Electric_Device_Operation True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Medium Voltage Sectionalizer: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Sectionalizer Unknown type of Medium Voltage Sectionalizer. Single terminal ['E:Switch - Sectionalizing'] NONE DO_NOT_SPLIT END_VERTEX
1 AC Overhead Single terminal ['E:Cable - Overhead', 'E:Switch - Sectionalizing'] NONE DO_NOT_SPLIT END_VERTEX
2 AC Underground Single terminal ['E:Switch - Sectionalizing'] NONE DO_NOT_SPLIT END_VERTEX
4 AC Overhead - Controller Single terminal ['E:Cable - Overhead', 'E:Switch - Sectionalizing'] NONE DO_NOT_SPLIT END_VERTEX
5 AC Underground - Controller Single terminal ['E:Switch - Sectionalizing'] NONE DO_NOT_SPLIT END_VERTEX
731 Overhead Single Phase Sectionalizer MV A medium voltage single phase overhead sectionalizing switch. Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Section Devices', 'E:Switch - Sectionalizing'] NONE DO_NOT_SPLIT END_VERTEX
745 Overhead Three Phase Sectionalizer MV A medium voltage three phase overhead sectionalizing switch where all three phases are operated the same way at all times. Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Section Devices', 'E:Switch - Sectionalizing'] NONE DO_NOT_SPLIT END_VERTEX
749 Pad Mounted Single Phase Sectionalizer MV A medium voltage single phase sectionalizing switch used in a cabinet. Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Section Devices', 'E:Switch - Sectionalizing'] NONE DO_NOT_SPLIT END_VERTEX
750 Pad Mounted Three Phase Sectionalizer MV A medium voltage three phase sectionalizing switch used in a cabinet. Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Section Devices', 'E:Switch - Sectionalizing'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Switch
A switch used to control the flow of energy.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Medium_Voltage_Switch False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Device_Switch_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Medium_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Medium_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT Yes_No True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_Medium_Voltage_Fuse_Continuous_Amps True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG Electric_Medium_Voltage_Fuse_Interrupting_Amps True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT Electric_Device_Operation True
operatingmechanism Field Operating Mechanism SHORT Electric_Device_OperatingMechanism True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Medium Voltage Switch: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Switch A unknown switch type used in the medium voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
1 AC Overhead Single terminal ['E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
2 AC Underground Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
3 AC Station Single terminal ['E:Station'] NONE DO_NOT_SPLIT END_VERTEX
4 AC Overhead - Controller Single terminal ['E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
5 AC Underground - Controller Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
6 AC Station - Controller Single terminal ['E:Station'] NONE DO_NOT_SPLIT END_VERTEX
721 Cabinet Bypass MV A medium voltage cabinet bypass switch. Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
722 Cabinet Switch MV A medium voltage cabinet switch. Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
723 Cabinet Switch - Grounded MV A medium voltage Grounding cabinet switch. Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
724 Overhead Bypass MV A mechanical switch that can change between three connections used in the medium voltage system Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
725 Overhead Grounding Switch MV An aerial mounted grounding switch in the medium voltage system Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
726 Overhead Jumper MV An aerial mounted jumper in the medium voltage system Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
727 Station Grounding MV A grounding switch located in a station in the medium voltage system that can also be a subnetwork controller Single terminal ['Asset Functional', 'E:Station', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
728 Overhead Single Phase Disconnect MV An aerial mounted single phase disconnecting switch in the medium voltage system Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
729 Overhead Single Phase Load Break MV An aerial mounted single phase load breaking switch in the medium voltage system Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
732 Overhead Three Phase Disconnect MV An aerial mounted three phase disconnecting switch in the medium voltage system where all three phases are operated the same way Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
733 Overhead Three Phase Load Break MV An aerial mounted three phase load breaking switch in the medium voltage system where all three phases are operated the same way Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
746 Pad Mounted Fault Interrupter MV A pad mounted switch designed to break faults safely in the medium voltage system Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Protective', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
751 Station Single Phase Disconnect MV A single phase disconnect switch located in a station in the medium voltage system Single terminal ['Asset Functional', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
752 Station Disconnect MV A disconnecting switch located in a station in the medium voltage system Single terminal ['Asset Functional', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
753 T Blade MV A multipositional three phase switch typically used a pad mounted switch cabinet in the medium voltage system T-Blade Switch ['Asset Functional', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
754 V Blade MV A multipositional three phase switch typically used a pad mounted switch cabinet in the medium voltage system V-Blade Switch ['Asset Functional', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
755 Underground Single Phase Disconnect MV A single phase disconnecting switch in the underground portion of the medium voltage system Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
758 Underground Single Phase Load Break MV A single phase load breaking switch in the underground portion of the medium voltage system Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
759 Underground Three Phase Disconnect MV A three phase disconnecting switch in the underground portion of the medium voltage system Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
760 Underground Three Phase Load Break MV A three phase load breaking switch in the underground portion of the medium voltage system Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
761 Underground Transfer Switch MV A three phase switch that can switch between sources in the underground portion of the medium voltage system Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
765 Bus Tie Breaker MV A switch used to connect busbar in a station in the medium voltage system Single terminal ['Asset Functional', 'E:Switch', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
766 Station Load Break MV A load breaking switch located in a station in the medium voltage system Single terminal ['Asset Functional', 'E:Station', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
768 Station Disconnect - Grounded MV A disconnecting switch that when open is provides paths to ground located in a station in the medium voltage system Single terminal ['Asset Functional', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
769 Station Load Break Disconnect MV A disconnect and load breaking switch located in a station in the medium voltage system Single terminal ['Asset Functional', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
770 Station Disconnect MV - Controller A disconnecting switch located in a station in the medium voltage system that can also be a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
771 Station Load Break MV - Controller A load breaking switch located in a station in the medium voltage system that can also be a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Station', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
772 Station Load Break Disconnect MV - Controller A disconnect and load breaking switch located in a station in the medium voltage system that can also be a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Transformer
Transformer devices represent a single electrical transformer. These devices can be by phase or polyphase.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Medium_Voltage_Transformer False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondarygrounding Secondary Winding Ground SHORT Electric_Ground_Configuration True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
tertiarygrounding Tertiary Winding Ground SHORT Electric_Ground_Configuration True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE Electric_Tap_Maximum_Change True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE Electric_Load_Tap_Bandwidth True
maximumboost Maximum Voltage Boost DOUBLE Electric_Buck_Boost_Rate True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE Electric_Impedance_Range True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT Electric_XFR_Type True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE Electric_Temperature_F True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_Medium_Voltage_Transformer_VA True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG Electric_Medium_Voltage_Transformer_VA True
loadtapchangepercent Load Tap Change (%) SHORT Electric_Tap_Change_Percent True
noloadloss Losses, No Load Loss LONG Electric_Medium_Voltage_Load_Loss True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT Electric_Transformer_Cooling True
inparallel In Parallel SHORT Yes_No True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Medium Voltage Transformer: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Transformer A transformer of unknown type used in the medium voltage system Single terminal ['E:Load'] NONE DO_NOT_SPLIT END_VERTEX
781 Grounding Transformer - MV->MV A specialized transformer for changing the system grounding between the medium voltage system Single terminal ['Asset Functional', 'E:Load', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
782 Mobile Single Phase - MV->LV A trailer mounted single phase voltage transformer that converts from medium voltage to low voltage Single terminal ['Asset Functional', 'E:Load', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
783 Mobile Three Phase - MV->LV A trailer mounted three phase voltage transformer that converts from medium voltage to low voltage Single terminal ['Asset Functional', 'E:Load', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
784 Network - MV->LV A transformer used to feed underground low voltage mesh networks that allow energy to flow in only one direction from the medium voltage system Single terminal ['E:Load', 'E:Station', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
785 Overhead Single Phase - MV->LV A pole mounted single phase transformer used to convert power from medium voltage to low voltage Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Load', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
786 Station - MV->LV A station located transformer used to convert power from medium voltage to low voltage Single terminal ['Asset Functional', 'E:Load', 'E:Station', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
787 Station Three Winding - MV->LV-LV A three winding transformer that converts an incoming medium voltage current to two different voltages, both low voltages Single terminal ['E:Load', 'E:Station', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
788 Overhead Three Phase - MV->LV A pole mounted three phase transformer used to convert power from medium voltage to low voltage Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Load', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
789 Pad Mounted Single Phase - MV->LV A pad mounted single phase transformer used to convert power from medium voltage to low voltage Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
790 Station Three Winding - MV->MV-LV A three winding transformer that converts an incoming medium voltage current to two different voltages, one high and one medium Single terminal ['Asset Functional', 'E:Load', 'E:Station', 'E:Transformer - Distribution', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
792 Pad Mounted Three Phase - MV->LV A pad mounted three phase transformer used to convert power from medium voltage to low voltage Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
793 Submersible Single Phase - MV->LV A medium voltage submersible single phase transformer. Single terminal ['Asset Functional', 'E:Cable - Submersible', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
794 Submersible Three Phase - MV->LV A medium voltage to low voltage three phase transformer that can be used in locations prone to flooding Single terminal ['Asset Functional', 'E:Cable - Submersible', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Distribution', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
801 Overhead Single Phase Step - MV<->MV A pole mounted single phase transformer used to convert power from medium voltage to a different medium voltage Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
802 Overhead Three Phase Step - MV<->MV A pole mounted three phase transformer used to convert power from medium voltage to a different medium voltage Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
803 Overhead Single Phase Step - MV->MV A pole mounted single phase transformer used to convert power from medium voltage to a different medium voltage that can also be used as a subnetwork controller Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
804 Overhead Three Phase Step - MV->MV A pole mounted three phase transformer used to convert power from medium voltage to a different medium voltage that can also be used as a subnetwork controller Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
805 Pad Mounted Single Phase Step - MV<->MV A pad mounted single phase transformer used to convert power from medium voltage to a different medium voltage Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
806 Pad Mounted Three Phase Step - MV<->MV A pad mounted three phase transformer used to convert power from medium voltage to a different medium voltage Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
807 Pad Mounted Single Phase Step - MV->MV A pad mounted single phase transformer used to convert power from medium voltage to a different medium voltage that can also be used as a subnetwork controller Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
808 Pad Mounted Three Phase Step - MV->MV A pad mounted three phase transformer used to convert power from medium voltage to a different medium voltage that can also be used as a subnetwork controller Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
809 Submersible Single Phase Step - MV<->MV A medium voltage single phase transformer used to increase or decrease voltage within the medium voltage range that uses a bidirectional terminal configuration that can be used in locations prone to flooding Single terminal ['Asset Functional', 'E:Cable - Submersible', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
810 Submersible Three Phase Step - MV<->MV A medium voltage three phase transformer used to step up or down the voltage to a different medium voltage level that can be used in locations prone to flooding using a utility network bidirectional terminal configuration Single terminal ['Asset Functional', 'E:Cable - Submersible', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
811 Submersible Single Phase Step - MV->MV A medium voltage single phase transformer used to increase or decrease voltage within the medium voltage range that uses a directional terminal configuration that can be used in locations prone to flooding Single terminal ['Asset Functional', 'E:Cable - Submersible', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
812 Submersible Three Phase Step - MV->MV A medium voltage three phase transformer used to step up or down the voltage to a different medium voltage level that can be used in locations prone to flooding using a utility network directional terminal configuration Single terminal ['Asset Functional', 'E:Cable - Submersible', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
813 Station Step - MV->MV A station located transformer used to convert power from medium voltage to a different medium voltage that can also be used as a subnetwork controller Single terminal ['Asset Functional', 'E:Load', 'E:Station', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
814 Station Step - MV<->MV A station located transformer used to convert power from medium voltage to a different medium voltage Single terminal ['Asset Functional', 'E:Load', 'E:Station', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
815 Station Step Three Winding - MV->MV-MV A three winding transformer that converts an incoming medium voltage current to two different output medium voltages Single terminal ['Asset Functional', 'E:Load', 'E:Station', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
816 Overhead Three Phase Step Up - LV->MV A pole mounted three phase transformer used to convert power from low voltage to medium voltage that can also be used as a subnetwork controller Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
817 Overhead Three Phase Step Up - LV<->MV A pole mounted three phase transformer used to convert power from low voltage to medium voltage Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
818 Station Step Up - LV->MV A transformer used to increase the voltage from Low Voltage levels to Medium Voltage levels that can be a subnetwork controller Single terminal ['Asset Functional', 'E:Load', 'E:Station', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
819 Station Step Up - LV<->MV A transformer used to increase the voltage from Low Voltage levels to Medium Voltage levels Single terminal ['Asset Functional', 'E:Load', 'E:Station', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
820 Pad Mounted Three Phase Step Up - LV->MV A pad mounted three phase transformer used to convert power from low voltage to medium voltage that can also be used as a subnetwork controller Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
821 Pad Mounted Three Phase Step Up - LV<->MV A pad mounted three phase transformer used to convert power from low voltage to medium voltage that can also be used as a subnetwork controller Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
822 Overhead Single Phase Step Up - LV->MV Single terminal ['E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
823 Overhead Single Phase Step Up - LV<->MV Single terminal ['E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
824 Pad Mounted Single Phase Step Up - LV->MV Single terminal ['E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
825 Pad Mounted Single Phase Step Up - LV<->MV Single terminal ['E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Transformer Winding
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT Asset_Type_Electric_JunctionObject_Medium_Voltage_Transformer_Winding False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Medium_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Medium_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Medium_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT True
grounding Grounding SHORT True
nominalvoltage Nominal Voltage (L-L) LONG True
nominalvoltagelg Nominal Voltage (L-G) LONG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Medium_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT Electric_Tap_Change_Percent True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Medium Voltage Transformer Winding: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Transformer Winding Single terminal ['E:Load'] NONE DO_NOT_SPLIT END_VERTEX
873 Transformer Winding MV Transformer Winding ['Asset Functional', 'E:Load', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Circuit Breaker
A circuit breaker used on low voltage equipment, typically inside of a low voltage station
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Low_Voltage_Circuit_Breaker False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT Yes_No True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_Low_Voltage_Fuse_Continuous_Amps True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG Electric_Low_Voltage_Fuse_Interrupting_Amps True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT Electric_Device_Operation True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Low Voltage Circuit Breaker: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Circuit Breaker a mechanical switching device of unknown type in the low voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
1 AC Overhead Single terminal ['E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
2 AC Underground Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
3 AC Station Single terminal ['E:Station'] NONE DO_NOT_SPLIT END_VERTEX
4 AC Overhead - Controller Single terminal ['E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
5 AC Underground - Controller Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
6 AC Station - Controller Single terminal ['E:Station'] NONE DO_NOT_SPLIT END_VERTEX
11 DC Overhead Single terminal ['E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
12 DC Underground Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
13 DC Station Single terminal ['E:Station'] NONE DO_NOT_SPLIT END_VERTEX
14 DC Overhead - Controller Single terminal ['E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
15 DC Underground - Controller Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
16 DC Station - Controller Single terminal ['E:Station'] NONE DO_NOT_SPLIT END_VERTEX
471 AC Circuit Breaker LV A mechanical switching device used in the low voltage AC system Single terminal ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
472 DC Circuit Breaker LV A mechanical switching device used in the low voltage DC system Single terminal ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
473 AC Circuit Breaker LV - Controller A mechanical switching device used in the low voltage AC system that can also be a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
474 DC Circuit Breaker LV - Controller A mechanical switching device used in the low voltage DC system that can also be a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Circuit Breaker', 'E:Switch - Load Break', 'E:Switch - Reclosing', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Insulating Equipment
A device used to protect equipment from over voltage conditions such as lighting strikes.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Low_Voltage_Arrester False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_Low_Voltage_Arrester_Design True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_Discharge_Current True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG Electric_Discharge_Current True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Low Voltage Insulating Equipment: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Arrester An arrester used unknown situations in the low voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
221 Overhead Arrester LV An arrester used in aerial situations in the low voltage system Single terminal ['Asset Functional', 'E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
222 Underground Arrester LV An arrester used in pad mounted equipment or values in the low voltage system Single terminal ['Asset Functional', 'E:Cable - Underground'] NONE DO_NOT_SPLIT END_VERTEX
223 Station Arrester LV An arrester used inside stations in the low voltage system Single terminal ['Asset Functional', 'E:Station'] NONE DO_NOT_SPLIT END_VERTEX
224 Indoor Arrester LV An arrester used in indoor situations in the low voltage system Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
225 Overhead Insulator LV Single terminal ['Asset Functional', 'E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
226 Underground Insulator LV Single terminal ['Asset Functional', 'E:Cable - Underground'] NONE DO_NOT_SPLIT END_VERTEX
227 Station Insulator LV Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
228 Indoor Insulator LV Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Control Unit
A electronic controller used to control the state of equipment used in low voltage systems, such as switches.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Low_Voltage_Control_Unit False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_Closing_Mode True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE Electric_Temperature_F True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Low Voltage Control Unit: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Control Unit A device used to control unknown equipment types in the low voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
241 Control Unit LV A device used to control a electrical equipment in the low voltage system Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Fuse
A device used to protect the system from over current conditions, such as faults.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Low_Voltage_Fuse False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_Low_Voltage_Fuse_Type True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_Low_Voltage_Fuse_Continuous_Amps True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG Electric_Low_Voltage_Fuse_Interrupting_Amps True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT Electric_Device_Operation True
operatingmechanism Field Operating Mechanism SHORT Electric_Device_OperatingMechanism True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Low Voltage Fuse: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Fuse Unknown type of Low Voltage Fuse. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
1 AC Overhead Single terminal ['E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
2 AC Underground Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
3 AC Station Single terminal ['E:Station'] NONE DO_NOT_SPLIT END_VERTEX
4 AC Overhead - Controller Single terminal ['E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
5 AC Underground - Controller Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
6 AC Station - Controller Single terminal ['E:Station'] NONE DO_NOT_SPLIT END_VERTEX
11 DC Overhead Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
12 DC Underground Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
13 DC Station Single terminal ['E:Station'] NONE DO_NOT_SPLIT END_VERTEX
14 DC Overhead - Controller Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
15 DC Underground - Controller Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
16 DC Station - Controller Single terminal ['E:Station'] NONE DO_NOT_SPLIT END_VERTEX
259 Service Fuse Load Break LV Single terminal ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Station', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
260 Service Fuse Disconnect LV Single terminal ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
261 AC Overhead Fuse LV An AC overhead fuse Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
262 AC Underground Fuse LV An AC underground conductor that represents some number of physical cables. Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
263 DC Overhead Fuse LV A DC overhead conductor that represents some number of physical cables. Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
264 DC Underground Fuse LV A DC underground conductor that represents some number of physical cables. Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
265 AC Overhead Load Break Fuse LV An AC Overhead Fuse used as a load breaking switch Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
266 AC Overhead Fuse LV - Controller An AC overhead fuse used as a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
267 AC Underground Load Break Fuse LV A fuse that can be used as a load breaking switch used in the underground part of a low voltage system Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
268 AC Underground Fuse LV - Controller An AC underground conductor that represents some number of physical cables, also used as a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Cable - Overhead', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
269 DC Overhead Fuse LV - Controller A DC overhead conductor that represents some number of physical cables, also used as a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
270 DC Underground Fuse LV - Controller A DC underground conductor that represents some number of physical cables, also used as a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Cable - Underground', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
271 AC Overhead Cutout Load Break Disconnect Fuse LV An AC overhead fuse also used as a disconnect and Load breaking switch Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
272 AC Overhead Cutout Load Break Fuse LV - Controller An AC overhead fuse also used as a Load breaking switch and as a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
273 AC Overhead Cutout Disconnect Fuse LV - Controller An AC overhead fuse also used as a disconnect switch with and as a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
274 AC Overhead Cutout Load Break Fuse LV An AC overhead fuse also used as a Load breaking switch Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Fault Breaking', 'E:Protective', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
275 Station Disconnect Fuse LV A fuse found in a station that can also be used as a disconnect switch in the low voltage system Single terminal ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
276 Station Load Break Fuse LV A fuse found in a station that can also be used as a load breaking switch in the low voltage system Single terminal ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Station', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
277 Station Load Break Disconnect Fuse LV A fuse found in a station that can also be used as a disconnect or load breaking switch in the low voltage system Single terminal ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
278 Station Disconnect Fuse LV - Controller A fuse found in a station that can also be used as a disconnect switch in the low voltage system and can be a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
279 Station Load Break Fuse LV - Controller A fuse found in a station that can also be used as a load breaking switch in the low voltage system and is a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Station', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
280 Station Load Break Disconnect Fuse LV - Controller A fuse found in a station that can also be used as a disconnect or load breaking switch in the low voltage system and can be a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Fault Breaking', 'E:Protective', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Generation
Generation devices typically located at a customer residence, like rooftop solar.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Low_Voltage_Generation False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_Generator_Control_Type True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE Electric_Impedance_Range True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT Electric_Generation_ANSI_Group_Code True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_Low_Voltage_Transformer_VA True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Low Voltage Generation: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Generation Unknown type of Low Voltage Generation. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
281 Battery LV A low wattage Battery. Single terminal ['Asset Functional', 'E:Generation', 'E:Generation - Distributed', 'E:Generation - Storage'] NONE DO_NOT_SPLIT END_VERTEX
283 Generator LV A low voltage energy storage device frequently installed at residences. Single terminal ['Asset Functional', 'E:Generation', 'E:Generation - Distributed'] NONE DO_NOT_SPLIT END_VERTEX
284 Residential Photovoltaic Solar LV A low Wattage Photovoltaic solar. Single terminal ['Asset Functional', 'E:Generation', 'E:Generation - Distributed'] NONE DO_NOT_SPLIT END_VERTEX
285 Wind Turbine LV A low Wattage Windmill. Single terminal ['Asset Functional', 'E:Generation', 'E:Generation - Distributed'] NONE DO_NOT_SPLIT END_VERTEX
286 AC Wave LV A Ocean Wave Generation station providing power to the low voltage system Single terminal ['Asset Functional', 'E:Generation', 'E:Generation - Distributed'] NONE DO_NOT_SPLIT END_VERTEX
428 Car Charger LV A Car Charge connected to the Low Voltage system that is also used to provide power to the low voltage system Single terminal ['Asset Functional', 'E:Generation', 'E:Generation - Distributed', 'E:Generation - Storage'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Lighting
A device used for lighting such as a streetlight or flood light.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Low_Voltage_Lighting False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_Light_Housing_Type True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Low Voltage Lighting: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Lighting A light of unknown type connected to the low voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
301 Floodlight LV A flood light connected to the low voltage system Single terminal ['Asset Functional', 'E:Lighting', 'E:Load'] NONE DO_NOT_SPLIT END_VERTEX
302 Streetlight LV A street light connected to the low voltage system Single terminal ['Asset Functional', 'E:Lighting', 'E:Load'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Line Monitor and Relay
Line monitors are frequently used in conjunction with SCADA systems to monitor system conditions.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Low_Voltage_Line_Monitor_and_Relay False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT Electric_RTU_Data_Type True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Low Voltage Line Monitor and Relay: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Line Monitor and Relay Unknown type of Low Voltage Line Monitor and Relay. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
321 Fault Indicator LV A Fault indicator used in low voltage systems. Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
322 Load Monitor LV A load monitoring sensor used in low voltage systems. Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
323 Relay LV A relay used in low voltage systems. Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
324 Instrument Transformer LV A specific type of transformer used in monitoring Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Motor
A motor, typically used in industrial operations.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Low_Voltage_Motor False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_Motor_Type True
manufacturer Manufacturer SHORT True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE Electric_Impedance_Range True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT Electric_Generation_ANSI_Group_Code True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Low Voltage Motor: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Motor Unknown type of Low Voltage Motor. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
341 Single Phase Motor LV A low Voltage single phase motor. Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
342 Three Phase Motor LV A low Voltage three phase motor. Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
343 DC Motor LV A monitor that runs on Direct Current Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Network Protection
A device used to prevent energy from flowing in one direction. Typically used in mesh network systems.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Low_Voltage_Network_Protection False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_Low_Voltage_Fuse_Continuous_Amps True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG Electric_Low_Voltage_Fuse_Interrupting_Amps True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Low Voltage Network Protection: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Network Protector Unknown type of Low Voltage Network Protection. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
361 Network Protector LV A low voltage device like a circuit breaker but also prevents energy flow in one direction. Circuit Breaker Directional ['Asset Functional', 'E:Protective', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Power Conversion
A device used to convert power type from AC to DC or DC to AC.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Low_Voltage_Power_Conversion False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG Electric_DC_Low_Voltage_Nominal_Voltage True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT Electric_Ground_Configuration True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE Electric_Device_Resistance_Range True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_Low_Voltage_Transformer_VA True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Low Voltage Power Conversion: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Power Conversion A device that converts power of unknown type in the low voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
381 Single Phase Inverter LV A device that converts input energy from DC to output energy of AC in the low voltage system Single terminal ['Asset Functional', 'E:Power Conversion'] NONE DO_NOT_SPLIT END_VERTEX
382 Single Phase Rectifier LV A device that converts input energy from AC to output energy of DC in the low voltage system Single terminal ['Asset Functional', 'E:Power Conversion'] NONE DO_NOT_SPLIT END_VERTEX
383 Three Phase Inverter LV A device that converts input energy from DC to output energy of AC Three Phase in the low voltage system Single terminal ['Asset Functional', 'E:Power Conversion'] NONE DO_NOT_SPLIT END_VERTEX
384 Three Phase Rectifier LV A device that converts input energy from three phase AC to output energy of DC in the low voltage system Single terminal ['Asset Functional', 'E:Power Conversion'] NONE DO_NOT_SPLIT END_VERTEX
386 Single Phase Bidirectional LV A power conversion device used to convert AC to DC or DC to AC in the low voltage system Single terminal ['Asset Functional', 'E:Power Conversion'] NONE DO_NOT_SPLIT END_VERTEX
387 Three Phase Bidirectional LV A power conversion device used to convert three phase AC to DC or DC to AC three phase in the low voltage system Single terminal ['Asset Functional', 'E:Power Conversion'] NONE DO_NOT_SPLIT END_VERTEX
390 Wave Trap LV Equipment used to prevent high frequency carrier signals of power line communication to unwanted destinations, low voltage system Single terminal ['Asset Functional', 'E:Power Conversion'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Power Factor Correcting
A device used in the correction of the power factor of AC energy.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Low_Voltage_Power_Factor_Correcting False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_Configuration_Type True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE Electric_Device_Resistance_Range True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT Electric_Capacitory_Type True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE Electric_Temperature_F True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_Low_Voltage_KVAR True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Low Voltage Power Factor Correcting: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Power Factor Correcting A power factor correcting device of unknown type in the low voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
1 AC Overhead Single terminal ['E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
2 AC Underground Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
3 AC Station Single terminal ['E:Station'] NONE DO_NOT_SPLIT END_VERTEX
4 AC Overhead - Controller Single terminal ['E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
5 AC Underground - Controller Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
6 AC Station - Controller Single terminal ['E:Station'] NONE DO_NOT_SPLIT END_VERTEX
11 DC Overhead Single terminal ['E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
12 DC Underground Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
13 DC Station Single terminal ['E:Station'] NONE DO_NOT_SPLIT END_VERTEX
14 DC Overhead Directional Single terminal ['E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
15 DC Underground Directional Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
16 DC Station Directional Single terminal ['E:Station'] NONE DO_NOT_SPLIT END_VERTEX
401 Mobile Harmonic Filter LV A harmonic filter mounted on a trailer used in the low voltage system Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
402 Mobile Reactor LV A reactor mounted on a trailer used in the low voltage system Single terminal ['Asset Functional', 'E:Reactive Power'] NONE DO_NOT_SPLIT END_VERTEX
403 Overhead Capacitor LV A pole mounted capacitor used in the low voltage system Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Reactive Power'] NONE DO_NOT_SPLIT END_VERTEX
404 Overhead Harmonic Filter LV A pole mounted harmonic filter used in the low voltage system Single terminal ['Asset Functional', 'E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
405 Overhead Reactor LV A pole mounted reactor used in the low voltage system Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Reactive Power'] NONE DO_NOT_SPLIT END_VERTEX
406 Pad Mounted Capacitor LV A pad mounted capacitor used in the low voltage system Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Reactive Power'] NONE DO_NOT_SPLIT END_VERTEX
407 Pad Mounted Harmonic Filter LV A pad mounted harmonic filter used in the low voltage system Single terminal ['Asset Functional', 'E:Cable - Underground'] NONE DO_NOT_SPLIT END_VERTEX
408 Pad Mounted Reactor LV A pad mounted reactor used in the low voltage system Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Reactive Power'] NONE DO_NOT_SPLIT END_VERTEX
409 Station Capacitor LV A capacitor used in the low voltage system found in a station Single terminal ['Asset Functional', 'E:Reactive Power', 'E:Station'] NONE DO_NOT_SPLIT END_VERTEX
410 Station Harmonic Filter LV A harmonic filter used in the low voltage system found in a station Single terminal ['Asset Functional', 'E:Station'] NONE DO_NOT_SPLIT END_VERTEX
411 Station Reactor LV A reactor used in the low voltage system found in a station Single terminal ['Asset Functional', 'E:Reactive Power', 'E:Station'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Service
A service location or load point used in the delivery of low voltage power, frequently thought of as a meter location.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Low_Voltage_Service False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG Electric_Low_Voltage_Load_Loss True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Low Voltage Service: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Service A unknown type of service metering point in the low voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
421 Single Phase Commercial LV A single phase metering device used for a commercial customer in the low voltage system Single terminal ['Asset Functional', 'E:Load', 'E:Load - Commercial', 'E:Load - Customer'] NONE DO_NOT_SPLIT END_VERTEX
422 Single Phase Residential LV A single phase metering device used for a residential customer in the low voltage system Single terminal ['Asset Functional', 'E:Load', 'E:Load - Customer', 'E:Load - Residential'] NONE DO_NOT_SPLIT END_VERTEX
423 Three Phase Commercial LV A three phase metering device used for a commercial customer in the low voltage system Single terminal ['Asset Functional', 'E:Load', 'E:Load - Commercial', 'E:Load - Customer'] NONE DO_NOT_SPLIT END_VERTEX
424 Three Phase Residential LV A three phase metering device used for a residential customer in the low voltage system Single terminal ['Asset Functional', 'E:Load', 'E:Load - Customer', 'E:Load - Residential'] NONE DO_NOT_SPLIT END_VERTEX
425 Unmetered Load LV A point representing load not associated with a customer in the low voltage system Single terminal ['Asset Functional', 'E:Load', 'E:Load - Customer'] NONE DO_NOT_SPLIT END_VERTEX
426 DC Commercial LV A low voltage commercial service receiving Direct Current. Single terminal ['Asset Functional', 'E:Load', 'E:Load - Commercial', 'E:Load - Customer'] NONE DO_NOT_SPLIT END_VERTEX
427 Low Voltage Premise LV A service location of a customer connected to the low voltage system Single terminal ['Asset Functional', 'E:Load', 'E:Load - Customer', 'E:Load - Residential'] NONE DO_NOT_SPLIT END_VERTEX
428 Car Charger LV A Car Charge connected to the Low Voltage system Single terminal ['Asset Functional', 'E:Load', 'E:Load - Customer', 'E:Load - Residential'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Switch
A switch used to control the flow of energy.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Low_Voltage_Switch False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Device_Switch_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT Yes_No True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_Low_Voltage_Fuse_Continuous_Amps True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG Electric_Low_Voltage_Fuse_Interrupting_Amps True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT Electric_Device_Operation True
operatingmechanism Field Operating Mechanism SHORT Electric_Device_OperatingMechanism True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Low Voltage Switch: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Switch A unknown switch type used in the low voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
1 AC Overhead Single terminal ['E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
2 AC Underground Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
3 AC Station Single terminal ['E:Station'] NONE DO_NOT_SPLIT END_VERTEX
4 AC Overhead - Controller Single terminal ['E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
5 AC Underground - Controller Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
6 AC Station - Controller Single terminal ['E:Station'] NONE DO_NOT_SPLIT END_VERTEX
11 DC Overhead Single terminal ['E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
12 DC Underground Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
13 DC Station Single terminal ['E:Station'] NONE DO_NOT_SPLIT END_VERTEX
14 DC Overhead - Controller Single terminal ['E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
15 DC Underground - Controller Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
16 DC Station - Controller Single terminal ['E:Station'] NONE DO_NOT_SPLIT END_VERTEX
431 AC Station Disconnect LV A station located disconnecting switch used in the low voltage AC system Single terminal ['Asset Functional', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
432 AC Station Load Break LV A station located load breaking switch used in the low voltage AC system Single terminal ['Asset Functional', 'E:Station', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
433 AC Station Load Break Disconnect LV A station located load breaking or disconnecting switch used in the low voltage AC system Single terminal ['Asset Functional', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
434 AC Station Disconnect LV - Controller A station located disconnecting switch used in the low voltage AC system that can also be used as a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
435 AC Station Load Break LV - Controller A station located load breaking switch used in the low voltage AC system that can also be used as a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Station', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
436 AC Station Load Break Disconnect LV - Controller A station located load breaking or disconnecting switch used in the low voltage AC system that can also be used as a subnetwork controller Circuit Breaker Directional ['Asset Functional', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Load Break', 'E:Switch - Section Devices', 'Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
441 Overhead AC Load Break LV An aerial mounted load breaking switch in the low voltage AC system Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
442 Overhead AC Disconnect LV An aerial mounted disconnecting switch in the low voltage AC system Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
443 Overhead DC Load Break LV An aerial mounted load breaking switch in the low voltage DC system Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
444 Overhead DC Disconnect LV An aerial mounted disconnecting switch in the low voltage DC system Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
445 Underground AC Load Break LV A load breaking switch in the underground portion of the low voltage AC system Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
446 Underground AC Disconnect LV A disconnecting switch in the underground portion of the low voltage AC system Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
447 Underground DC Load Break LV A load breaking switch in the underground portion of the low voltage DC system Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
448 Underground DC Disconnect LV A disconnecting switch in the underground portion of the low voltage DC system Single terminal ['Asset Functional', 'E:Cable - Underground', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
449 Indoor AC Load Break LV A load breaking switch located in an indoor location, such as a building or vault, in the low voltage AC system Single terminal ['Asset Functional', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
450 Indoor AC Disconnect LV A disconnecting switch located in an indoor location, such as a building or vault, in the low voltage AC system Single terminal ['Asset Functional', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
451 Indoor DC Load Break LV A load breaking switch located in an indoor location, such as a building or vault, in the low voltage DC system Single terminal ['Asset Functional', 'E:Switch', 'E:Switch - Load Break', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
452 Indoor DC Disconnect LV A disconnecting switch located in an indoor location, such as a building or vault, in the low voltage DC system Single terminal ['Asset Functional', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
453 Source Selectable Switch LV A switch capable of having two sources, where only one source can be selected at a time, in the low voltage AC system Single terminal ['Asset Functional', 'E:Switch', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
454 Overhead Jumper LV An aerial mounted jumper in the low voltage system Single terminal ['Asset Functional', 'E:Cable - Overhead', 'E:Switch', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
456 DC Station LV A station located switch used in the low voltage DC system Single terminal ['Asset Functional', 'E:Station', 'E:Switch', 'E:Switch - Disconnect', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
457 AC Station Bypass LV A mechanical switch that can change between three connections used in the low voltage AC system Single terminal ['Asset Functional', 'E:Station', 'E:Switch', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
458 AC Recloser LV A mechanical self closing switch used in the low voltage AC system Single terminal ['Asset Functional', 'E:Fault Breaking', 'E:Switch', 'E:Switch - Reclosing', 'E:Switch - Section Devices'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Transformer
Transformer devices represent a single electrical transformer. These devices can be by phase or polyphase.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Low_Voltage_Transformer False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondarygrounding Secondary Winding Ground SHORT Electric_Ground_Configuration True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
tertiarygrounding Tertiary Winding Ground SHORT Electric_Ground_Configuration True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE Electric_Tap_Maximum_Change True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE Electric_Load_Tap_Bandwidth True
maximumboost Maximum Voltage Boost DOUBLE Electric_Buck_Boost_Rate True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE Electric_Impedance_Range True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT Electric_XFR_Type True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG Electric_Low_Voltage_Transformer_VA True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT Electric_Tap_Change_Percent True
noloadloss Losses, No Load Loss LONG Electric_Low_Voltage_Load_Loss True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG Electric_Winding_Ratio_Long True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT Electric_Transformer_Cooling True
inparallel In Parallel SHORT Yes_No True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Low Voltage Transformer: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Transformer A transformer of unknown type used in the low voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
461 Single Phase - LV->LV A single phase transformer used to convert power from low voltage to a different low voltage Single terminal ['Asset Functional', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
462 Three Phase - LV->LV A low voltage three phase transformer. Single terminal ['Asset Functional', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
463 Three Winding - LV->LV-LV A three winding Low Voltage transformer Single terminal ['Asset Functional', 'E:Load', 'E:Transformer - Step', 'E:Transformer - Voltage'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Wire Connector
A non-operable device used to connect and disconnect electrical wires
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Low_Voltage_Wire_Connector False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT Electric_Operating_Status True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT Electric_Tap_Change_Percent True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Low Voltage Wire Connector: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Wire Connector Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
861 Ring Terminal LV Single terminal ['Asset Functional', 'E:Switch - Circuit Breaker'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Regulator
Voltage Regulator devices represent a device that is used in the regulation of voltage on the electric line.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Low_Voltage_Regulator False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT 3 Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Low_Voltage_Nominal_Voltage True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Low_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT Electric_Tap_Change_Percent True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Low Voltage Regulator: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Regulator A voltage regulating device used in the low voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
141 AC Single Phase LV An Single Phase Voltage Regulator used in Low Voltage AC system Single terminal ['Asset Functional', 'E:Voltage Regulation'] NONE DO_NOT_SPLIT END_VERTEX
142 AC Three Phase LV A three phase voltage regulator used in the low voltage AC system Single terminal ['Asset Functional', 'E:Voltage Regulation'] NONE DO_NOT_SPLIT END_VERTEX
143 DC Regulator LV An Voltage Regulator used in low Voltage DC system Single terminal ['Asset Functional', 'E:Voltage Regulation'] NONE DO_NOT_SPLIT END_VERTEX
144 Network Load Balancer LV A device used to balance load between phases in the low voltage system Single terminal ['Asset Functional', 'E:Voltage Regulation'] NONE DO_NOT_SPLIT END_VERTEX
145 Frequency Converter LV A device that converts a current with one frequency to a current with another frequency in the low voltage AC system Single terminal ['Asset Functional', 'E:Voltage Regulation'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Low Voltage Transformer Winding
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Low_Voltage_Transformer_Winding False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasechange User Assigned Phases SHORT Electric_Low_Voltage_Phase_Attribution True
phasessummer Summer Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesplan Planned Phases SHORT 0 Electric_Low_Voltage_Phase_Attribution False
phasesenergized Phases Energized SHORT 0 Electric_Low_Voltage_Phase_Attribution True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT 3 Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG 0 Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Nominal Voltage (L-G) LONG 0 Electric_Combined_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Low_Voltage_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT Electric_Tap_Change_Percent True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT Electric_Device_Operation True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Low Voltage Transformer Winding: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Transformer Winding Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
874 AC Transformer Winding LV Transformer Winding ['Subnetwork Controller'] NONE DO_NOT_SPLIT END_VERTEX
875 DC Transformer Winding LV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Line Hardware
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Line_Hardware False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT False
phasechange User Assigned Phases SHORT True
phasessummer Summer Configuration Phases SHORT False
phaseswinter Winter Configuration Phases SHORT False
phasesplan Planned Phases SHORT False
phasesenergized Phases Energized SHORT 0 Electric_Phase_Attribution_All True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_Cable_Hardware_Type True
manufacturer Manufacturer SHORT True
grounding Grounding SHORT True
nominalvoltage Nominal Voltage (L-L) LONG True
nominalvoltagelg Nominal Voltage (L-G) LONG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Combined_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Combined_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Line Hardware: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Line Hardware Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
833 Corona Ring Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
834 Damper Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
836 Spacer Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
837 Aerial Marker Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
838 Buried Cable Marker Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
839 Submerged Cable Marker Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
840 Overhead Water Crossing Marker Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
841 Airflow Spoiler Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
842 Bird Diverter Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
843 Line Weight Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Aerial Bare
Overhead Electric cables that are not shielded as Juction Objects. Using Junction Object reduces the storage of the row in the network index.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Aerial_Bare False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Attribution_All False
phasechange User Assigned Phases SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT 0 Electric_Phase_Attribution_All False
phasesenergized Phases Energized SHORT 0 Electric_Phase_Attribution_All True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Wire_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Combined_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Combined_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Aerial Bare: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
901 High Voltage AC Unknown type of Aerial Bare. Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage', 'E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
902 High Voltage DC A object representing a single Aerial Bare Cable used in the high voltage AC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage', 'E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
903 Medium Voltage A object representing a single Aerial Bare Cable used in the high voltage DC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High and Medium Voltage', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
904 Low Voltage AC A object representing a single Aerial Bare Cable used in the medium voltage system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Low Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
905 Low Voltage DC A object representing a single Aerial Bare Cable used in the low voltage AC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Low Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Aerial Covered
Overhead Electric cables that are shielded to prevent arcing as Juction Objects. Using Junction Object reduces the storage of the row in the network index.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Aerial_Covered False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Attribution_All False
phasechange User Assigned Phases SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT 0 Electric_Phase_Attribution_All False
phasesenergized Phases Energized SHORT 0 Electric_Phase_Attribution_All True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_Wire_Insulation_Type True
manufacturer Manufacturer SHORT Electric_Wire_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Combined_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Combined_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT Electric_Wire_Type True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Aerial Covered: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A object representing a single Aerial Bare Cable used in the low voltage DC system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
901 High Voltage AC Unknown type of Aerial Covered. Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage'] NONE DO_NOT_SPLIT END_VERTEX
902 High Voltage DC A object representing a single Aerial Covered or Shielded Cable used in the high voltage AC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage'] NONE DO_NOT_SPLIT END_VERTEX
903 Medium Voltage A object representing a single Aerial Covered or Shielded Cable used in the high voltage DC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High and Medium Voltage', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
904 Low Voltage AC A object representing a single Aerial Covered or Shielded Cable used in the medium voltage system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Low Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
905 Low Voltage DC A object representing a single Aerial Covered or Shielded Cable used in the low voltage AC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Low Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Overhead'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Busbar
Solid non-flexible conductors, typically found in stations as Juction Objects. Using Junction Object reduces the storage of the row in the network index.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Busbar False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Attribution_All False
phasechange User Assigned Phases SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT 0 Electric_Phase_Attribution_All False
phasesenergized Phases Energized SHORT 0 Electric_Phase_Attribution_All True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_Wire_Insulation_Type True
manufacturer Manufacturer SHORT Electric_Wire_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Combined_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Combined_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT Electric_Wire_Type True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Busbar: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A object representing a single Aerial Covered or Shielded Cable used in the low voltage DC system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
901 High Voltage AC Unknown type of Busbar. Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage'] NONE DO_NOT_SPLIT END_VERTEX
902 High Voltage DC A object representing a single busbar in the high voltage AC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage'] NONE DO_NOT_SPLIT END_VERTEX
903 Medium Voltage A object representing a single busbar in the high voltage DC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High and Medium Voltage', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage'] NONE DO_NOT_SPLIT END_VERTEX
904 Low Voltage AC A object representing a single busbar in the medium voltage system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Low Voltage'] NONE DO_NOT_SPLIT END_VERTEX
905 Low Voltage DC A object representing a single busbar in the low voltage AC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Low Voltage'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Underground
Underground Conductor Cables as Juction Objects. Using Junction Object reduces the storage of the row in the network index.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Underground False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Attribution_All False
phasechange User Assigned Phases SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT 0 Electric_Phase_Attribution_All False
phasesenergized Phases Energized SHORT 0 Electric_Phase_Attribution_All True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_Wire_Insulation_Type True
manufacturer Manufacturer SHORT Electric_Wire_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Combined_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Combined_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT Electric_Wire_Type True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Underground: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A object representing a single busbar in the low voltage DC system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
901 High Voltage AC Unknown type of Underground. Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage', 'E:Cable - Underground'] NONE DO_NOT_SPLIT END_VERTEX
902 High Voltage DC A object representing a single underground cable, used in the high voltage AC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage', 'E:Cable - Underground'] NONE DO_NOT_SPLIT END_VERTEX
903 Medium Voltage A object representing a single underground cable, used in the high voltage DC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High and Medium Voltage', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage', 'E:Cable - Underground'] NONE DO_NOT_SPLIT END_VERTEX
904 Low Voltage AC A object representing a single underground cable, used in the medium voltage system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Low Voltage', 'E:Cable - Underground'] NONE DO_NOT_SPLIT END_VERTEX
905 Low Voltage DC A object representing a single underground cable, used in the low voltage AC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Low Voltage', 'E:Cable - Underground'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Neutral
Electric conductors used as Neutral as Juction Objects. Using Junction Object reduces the storage of the row in the network index.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Neutral False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT False
phasechange User Assigned Phases SHORT True
phasessummer Summer Configuration Phases SHORT False
phaseswinter Winter Configuration Phases SHORT False
phasesplan Planned Phases SHORT False
phasesenergized Phases Energized SHORT 0 Electric_Phase_Attribution_All True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_Wire_Insulation_Type True
manufacturer Manufacturer SHORT Electric_Wire_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Combined_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Combined_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT Electric_Wire_Type True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Neutral: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A object representing a single underground cable, used in the low voltage DC system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
910 Overhead Bare Unknown type of Neutral. Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Overhead', 'E:Ground'] NONE DO_NOT_SPLIT END_VERTEX
911 Overhead Shielded A bare overhead neutral. Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Overhead', 'E:Ground'] NONE DO_NOT_SPLIT END_VERTEX
912 Underground Shielded An overhead shielded overhead neutral. Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Underground', 'E:Ground'] NONE DO_NOT_SPLIT END_VERTEX
913 Concentric An underground shielded overhead neutral. Single terminal ['Asset Functional', 'E:Cable', 'E:Ground'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Ground Wire
Electric conductors used to connect to grounds as Juction Objects. Using Junction Object reduces the storage of the row in the network index.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Ground_Wire False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT False
phasechange User Assigned Phases SHORT True
phasessummer Summer Configuration Phases SHORT False
phaseswinter Winter Configuration Phases SHORT False
phasesplan Planned Phases SHORT False
phasesenergized Phases Energized SHORT 0 Electric_Phase_Attribution_All True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_Wire_Insulation_Type True
manufacturer Manufacturer SHORT Electric_Wire_Manufacturer True
grounding Grounding SHORT True
nominalvoltage Nominal Voltage (L-L) LONG True
nominalvoltagelg Nominal Voltage (L-G) LONG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Combined_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Combined_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT Electric_Wire_Type True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Ground Wire: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal ['E:Cable'] NONE DO_NOT_SPLIT END_VERTEX
921 Covered Ground Single terminal ['Asset Functional', 'E:Cable', 'E:Ground'] NONE DO_NOT_SPLIT END_VERTEX
922 Bare Ground Single terminal ['Asset Functional', 'E:Cable', 'E:Ground'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Submarine
Electric conductors used in under water situations as Juction Objects. Using Junction Object reduces the storage of the row in the network index.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Submarine False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Attribution_All False
phasechange User Assigned Phases SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT 0 Electric_Phase_Attribution_All False
phasesenergized Phases Energized SHORT 0 Electric_Phase_Attribution_All True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT Electric_Wire_Insulation_Type True
manufacturer Manufacturer SHORT Electric_Wire_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Combined_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Combined_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT Electric_Wire_Type True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Submarine: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A unshielded ground cable Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
901 High Voltage AC Unknown type of Submarine. Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage'] NONE DO_NOT_SPLIT END_VERTEX
902 High Voltage DC A object representing a single submarine cable used in the high voltage AC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage'] NONE DO_NOT_SPLIT END_VERTEX
903 Medium Voltage A object representing a single submarine cable used in the high voltage DC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - High and Medium Voltage', 'E:Cable - Medium Voltage', 'E:Cable - Medium and Low Voltage'] NONE DO_NOT_SPLIT END_VERTEX
904 Low Voltage AC A object representing a single submarine cable used in the medium voltage system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Low Voltage'] NONE DO_NOT_SPLIT END_VERTEX
905 Low Voltage DC A object representing a single submarine cable used in the low voltage AC system Single terminal ['Asset Functional', 'E:Cable', 'E:Cable - Low Voltage'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Connector
A feature used to connect non-spatial junction features as Juction Objects. Using Junction Object reduces the storage of the row in the network index.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Connector False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT 0 Electric_Phase_Attribution_All False
phasechange User Assigned Phases SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT 0 Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT 0 Electric_Phase_Attribution_All False
phasesenergized Phases Energized SHORT 0 Electric_Phase_Attribution_All True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT True
numphasesconstructed Num Phases Built SHORT True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT True
grounding Grounding SHORT Electric_Ground_Configuration True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Nominal Voltage (L-G) LONG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG True
secondarygrounding Secondary Winding Ground SHORT True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG True
tertiarygrounding Tertiary Winding Ground SHORT True
maxvoltage Maximum Voltage LONG Electric_Combined_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Combined_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT True
operatingmechanism Field Operating Mechanism SHORT True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Connector: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A object representing a single submarine cable used in the low voltage DC system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
901 High Voltage AC Unknown type of Connector. Single terminal ['Asset Functional', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage'] NONE DO_NOT_SPLIT END_VERTEX
902 High Voltage DC A object used to connect objects in the high voltage AC system Single terminal ['Asset Functional', 'E:Cable - High Voltage', 'E:Cable - High and Medium Voltage'] NONE DO_NOT_SPLIT END_VERTEX
903 Medium Voltage A object used to connect objects in the high voltage DC system Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
904 Low Voltage AC A object used to connect objects in the medium voltage system Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
905 Low Voltage DC A object used to connect objects in the low voltage AC system Single terminal ['Asset Functional'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: High Voltage Tap Changer
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT Asset_Type_Electric_JunctionObject_HIgh_Voltage_Tap_Changer False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT Electric_Phase_Attribution_All False
phasechange User Assigned Phases SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT Electric_Phase_Attribution_All False
phasesenergized Phases Energized SHORT Electric_Phase_Attribution_All True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration_Transformer_Regulator True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondarygrounding Secondary Winding Ground SHORT Electric_Ground_Configuration_Transformer_Regulator True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
tertiarygrounding Tertiary Winding Ground SHORT Electric_Ground_Configuration_Transformer_Regulator True
maxvoltage Maximum Voltage LONG Electric_Combined_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_High_Voltage_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT Lifecycle_Status_Combined False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT Asset_Owner True
maintby Maintained By SHORT Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT Yes_No True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT Electric_Tap_Change_Percent True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT Electric_Tap_Change_Percent True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT Construction_Status False
fieldoperation Field Operation SHORT Electric_Device_Operation True
operatingmechanism Field Operating Mechanism SHORT Electric_Device_OperatingMechanism True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: High Voltage Tap Changer: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
925 Tap Changer Controller HV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
926 Regulator Tap Changer HV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
927 Transformer Tap Changer HV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Medium Voltage Tap Changer
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT Asset_Type_Electric_JunctionObject_Medium_Voltage_Tap_Changer False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT True
winteroperatingstatus Winter Status SHORT True
summeroperatingstatus Summer Status SHORT True
phasesnormal Phases Normal SHORT Electric_Phase_Attribution_All False
phasechange User Assigned Phases SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT Electric_Phase_Attribution_All False
phasesenergized Phases Energized SHORT Electric_Phase_Attribution_All True
phasessubstituted Phases Substituted LONG True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration_Transformer_Regulator True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondarygrounding Secondary Winding Ground SHORT Electric_Ground_Configuration_Transformer_Regulator True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
tertiarygrounding Tertiary Winding Ground SHORT Electric_Ground_Configuration_Transformer_Regulator True
maxvoltage Maximum Voltage LONG Electric_Combined_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG Electric_Combined_Nominal_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT Lifecycle_Status False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT Asset_Owner True
maintby Maintained By SHORT Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT Yes_No True
p2sphaseshift Phase Shift/Phase Angle SHORT True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT True
timedelay Trip Time Delay SHORT True
tripcount Lockout Trip Count SHORT True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT Electric_Tap_Change_Percent True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT Electric_Tap_Change_Percent True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT Construction_Status False
fieldoperation Field Operation SHORT Electric_Device_Operation True
operatingmechanism Field Operating Mechanism SHORT Electric_Device_OperatingMechanism True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Medium Voltage Tap Changer: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
930 Tap Changer Controller MV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
931 Regulator Tap Changer MV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
932 Transformer Tap Changer MV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Conductor Configuration
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Electric_JunctionObject_Conductor_Configuration False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
issubnetworkcontroller Is subnetwork controller SHORT 0 UtilityNetwork_5_IsSubnetworkController False
isconnected Is connected SHORT 2 UtilityNetwork_5_IsConnected False
subnetworkcontrollername Subnetwork controller name TEXT (2000) Unknown False
tiername Tier name LONG 0 UtilityNetwork_5_TierName False
tierrank Tier rank LONG 0 False
terminalconfiguration Terminal path TEXT (128) Default False
globalid Global ID GUID False
subnetworkname Subnetwork Name TEXT (2000) Unknown False
supportedsubnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
supportingsubnetworkname Supporting Subnetwork Name TEXT (2000) Unknown False
assetid Asset ID TEXT (64) True
normaloperatingstatus Normal Status SHORT Electric_Operating_Status True
winteroperatingstatus Winter Status SHORT Electric_Operating_Status True
summeroperatingstatus Summer Status SHORT Electric_Operating_Status True
phasesnormal Phases Normal SHORT Electric_Phase_Attribution_All False
phasechange User Assigned Phases SHORT Electric_Phase_Attribution_All True
phasessummer Summer Configuration Phases SHORT Electric_Phase_Attribution_All False
phaseswinter Winter Configuration Phases SHORT Electric_Phase_Attribution_All False
phasesplan Planned Phases SHORT Electric_Phase_Attribution_All False
phasesenergized Phases Energized SHORT Electric_Phase_Attribution_All True
phasessubstituted Phases Substituted LONG Electric_Medium_Voltage_Phase_Substitution True
phasefrequency Phase Frequency SHORT Electric_System_Frequency True
numphasesconstructed Num Phases Built SHORT Electric_Medium_Low_Voltage_Number_Of_Phases True
designtype Closing Mode, Fuel Type, Fuse Type, Ground Material, Light Type, Motor Type, Series or Shunt SHORT True
manufacturer Manufacturer SHORT Electric_Equipment_Manufacturer True
grounding Grounding SHORT Electric_Ground_Configuration_Transformer_Regulator True
nominalvoltage Nominal Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
nominalvoltagelg Nominal Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondaryvoltagelinetoline Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
secondaryvoltagelinetoground Secondary Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
secondarygrounding Secondary Winding Ground SHORT Electric_Ground_Configuration_Transformer_Regulator True
tertiaryvoltagelinetoline Tertiary Voltage (L-L) LONG Electric_Combined_Nominal_Voltage_LL True
tertiaryvoltagelinetoground Tertiary Voltage (L-G) LONG Electric_Combined_Nominal_Voltage_LG True
tertiarygrounding Tertiary Winding Ground SHORT Electric_Ground_Configuration_Transformer_Regulator True
maxvoltage Maximum Voltage LONG Electric_Combined_Maximum_Voltage True
maxoperatingvoltage Maximum Operating Voltage LONG ELectric_Combined_Maximumm_Operating_Voltage_LL True
compatibleunit Compatible Unit Code TEXT (255) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status_Combined False
model Device Model TEXT (255) True
loadtapchangermaximumchange Load Tap Changer Maximum Change DOUBLE True
loadtapchangerlowerbandwidth Load Tap Changer Lower Bandwidth DOUBLE True
maximumboost Maximum Voltage Boost DOUBLE True
z0psimpedance Sequence Impedance -Z0ps DOUBLE True
z0xmimpedance Sequence Impedance -Z0xm DOUBLE True
z1psimpedance Sequence Impedance -Z1ps DOUBLE True
x0r0impedance R0pm, Sequence Impedance -X0 DOUBLE True
x1r1impedance R1, Sequence Impedance -X1 DOUBLE True
z0pmimpedance Sequence Impedance -Z0pm DOUBLE True
primarygroundimpedance Inductance/Impedance DOUBLE True
gridsidecouplinginductance Inductance/Impedance DOUBLE True
remotecontrollerindicator Remote Control Indicator SHORT True
equipmentype Group/Type SHORT True
tripmode Single Phase Trip and Lockout SHORT True
tapsandpoles Number of Poles, Number of Taps SHORT True
directional Bi Directional/Reversible SHORT True
peakload Max Reactive Power, Peak Generation, Peak Load LONG True
offpeakload Min Reactive Power, Normal Generation, Off Peak Load LONG True
district District TEXT (255) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
ownedby Owned By SHORT Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
notes General Notes TEXT (2000) True
upperrange Upper Tempature Range - Operating DOUBLE True
lowerrange Lower Tempature Range - Operating DOUBLE True
primarygroundimpedance2 Inductance/Impedance DOUBLE True
reversetrip Reverse Trip SHORT Yes_No True
p2sphaseshift Phase Shift/Phase Angle SHORT Electric_Phase_Shift True
p2tphaseshift Master Angle, Primary to Tertiary Phase Shift SHORT Electric_Phase_Shift True
timedelay Trip Time Delay SHORT Electric_Trip_Delay_Range True
tripcount Lockout Trip Count SHORT Electric_Trip_Count True
tapmaxchange Over Current % Rated, Tap Maximum Change SHORT Electric_Tap_Change_Percent True
optype Assistance, Breaking Medium, Bulb Type, Control Type, Fuel Type, Fuse Element Type, Fuse Link Type, Operational Type SHORT True
maximumpower Continuous Amps Rating, Maximum Discharge Current (Amps), Maximum KVAR, Maximum Power, Maximum kVA, Maximum kVAR LONG True
minimumpower DC Input Power, Interrurpting Current, Maximum Interrupting Current, Reactive Generation, Switching Impulse Discharge Current (Amps) LONG True
ratedpower AC Output Power, Light Watts, Nominal Discharge Current (Amps), Rated Current, Rated Load (Watts), Rated Power, Rated kVA, Rated kVAR LONG True
loadtapchangepercent Load Tap Change (%) SHORT Electric_Tap_Change_Percent True
noloadloss Losses, No Load Loss LONG True
secondarygroundimpedance Secondary Ground Impedance DOUBLE True
ctratio CT Ratio LONG True
ptratio PT Ratio LONG True
maximumbuck Maximum Buck, Stator or Rotor Impedance DOUBLE True
secondarygroundimpedance2 Secondary Ground Impedance DOUBLE True
buckbandwidth Buck Bandwidth SHORT True
loadtapchangerupperbandwidth Diameter/Width DOUBLE True
loadtapchangerminimumchange LTC - Minimum Range, Load Tap Changer Minimum Change DOUBLE True
starthour Start Hour of Operation SHORT True
stophour Stop Hour of Operation SHORT True
powerfactor Power Factor DOUBLE True
coolingtype Cooling Type SHORT True
inparallel In Parallel SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
fieldoperation Field Operation SHORT Electric_Device_Operation True
operatingmechanism Field Operating Mechanism SHORT Electric_Device_OperatingMechanism True
sectionid Section ID TEXT (2000) True
isvalidloop Is Loop Valid SHORT Yes_No_Simple True
Subtype: Conductor Configuration: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
940 Overhead Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
941 Underground Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Utility Network Structure Classes

StructureBoundary

The Structure Boundary feature class represents features whose outline should be display on a map view or container view. Structure boundaries can contain structure edges, structure junctions, devices, lines, assemblies, and junctions.
Class Details
DatasetType ShapeType Alias Has Attachment
FEATURE_CLASS SIMPLE StructureBoundary True
Fields
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG 0 False
assettype Asset type SHORT 0 False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Supported subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
name Name TEXT (64) True
notes General Notes TEXT (2000) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status_Combined False
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
nitrogenoxide Amount of Nitrogenoxide Emitted DOUBLE True
sulphurdioxide Amount of Sulferdioxide Emitted DOUBLE True
carbondioxide Amount of Cabon Dioxide Emitted DOUBLE True
powerunits Maximum kW LONG True
addcount Number of Units SHORT True
devicecount Contained Count SHORT True
installdate Install Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
assetid Asset ID TEXT (64) True
maintby Maintained By SHORT 1 Asset_Manager True
materialcode Material Code SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
buildingtype Building Use SHORT Structure_Building_Type True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
shape_area SHAPE_Area DOUBLE True
Subtypes
Code Name Description
0 Unknown The Unknown asset group in the Structure Boundary feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it.
107 Electric Centralized Generation The boundary around a large scale power plants or energy production facilities.
108 Electric Distributed Generation The boundary of a smaller scale power generation facilities such as solar farms or gas fired turbines connected to medium voltage systems.
102 Electric Substation Boundary Electric Substation Boundary features are polygon features that outline of a Substation.
103 Electric Storage Facility Boundary Electric Storage Boundary features are polygon features that outline of a storage area, like a lake.
101 Wire Cabinet Boundary Wire Cabinet Boundary features are polygon features that outline of a cabinet.
104 Wire Vault Boundary Wire Vault Boundary features are polygon features that outline of a Vault.
105 Electric Switchgear Boundary Electric Switchgear Boundary features are polygon features that outline of a Switchgear and contain the electric equipment used in the switch.
106 Electric Bay Boundary Electric Bay Boundary features are polygon features that outline a grouping of related electric features, but there is no structure that accomplishes this.
110 Electric Zone An electrical area that can be used for managing switching or saftey
801 Building A structure used for commercial purposes
803 Support Various support structures used to represent things like Culverts and Bridges
Subtype: Unknown
The Unknown asset group in the Structure Boundary feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 UtilityNetwork_5_UnknownAssetType False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname SubnetworkName TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
notes General Notes TEXT (2000) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
devicecount Contained Count SHORT True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
assetid Asset ID TEXT (64) True
maintby Maintained By SHORT 1 Asset_Manager True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
shape_area SHAPE_Area DOUBLE True
Subtype: Unknown: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Boundary. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Electric Centralized Generation
The boundary around a large scale power plants or energy production facilities.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Boundary_Electric_Centralized_Generation False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
name Name TEXT (64) True
notes General Notes TEXT (2000) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
nitrogenoxide Amount of Nitrogen Oxide Emitted DOUBLE Electric_Generation_NOx True
sulphurdioxide Amount of Sulfer Dioxide Emitted DOUBLE Electric_Generation_SO2 True
carbondioxide Amount of Cabon Dioxide Emitted DOUBLE Electric_Generation_CO2 True
powerunits Maximum kW LONG Electric_High_Voltage_Generate_Watts True
addcount Number of Units SHORT Electric_Generation_Start_Time True
devicecount Contained Count SHORT True
installdate Install Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
assetid Asset ID TEXT (64) True
maintby Maintained By SHORT 1 Asset_Manager True
materialcode materialcode SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
shape_area SHAPE_Area DOUBLE True
Subtype: Electric Centralized Generation: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A polygon defining a generation facility of unknow type Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
21 Battery A polygon feature generation facility that uses a battery to store electricity Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
22 Biomass A polygon feature generation facility that uses biomass to create electricity Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
23 Coal A polygon feature generation facility that uses coal to create electricity Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
24 Gas Turbine A polygon feature generation facility that uses Natural Gas driven turbine to create electricity Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
25 Geothermal A polygon feature generation facility that uses Natural Geothermal driven turbine to create electricity Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
26 Hydro A polygon feature generation facility that uses Water to create electricity Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
27 Nuclear A polygon feature generation facility that uses Nuclear technology to create electricity Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
28 Photovoltaic Solar A polygon feature generation facility that uses a series of Photovolic Panels to create electricity Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
29 Thermal Solar A polygon feature generation facility that uses a series of Thermal solar technology to create electricity Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
30 Wind A polygon feature generation facility that uses a series of wind turbine technology to create electricity Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Electric Distributed Generation
The boundary of a smaller scale power generation facilities such as solar farms or gas fired turbines connected to medium voltage systems.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Boundary_Electric_Distributed_Generation False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
name Name TEXT (64) True
notes General Notes TEXT (2000) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
nitrogenoxide Amount of Nitrogen Oxide Emitted DOUBLE Electric_Generation_NOx True
sulphurdioxide Amount of Sulfer Dioxide Emitted DOUBLE Electric_Generation_SO2 True
carbondioxide Amount of Cabon Dioxide Emitted DOUBLE Electric_Generation_CO2 True
powerunits Maximum kW LONG Electric_Medium_Voltage_Generate_Watts True
addcount Number of Units SHORT Electric_Generation_Start_Time True
devicecount Contained Count SHORT True
installdate Install Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
assetid Asset ID TEXT (64) True
maintby Maintained By SHORT 1 Asset_Manager True
materialcode materialcode SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
shape_area SHAPE_Area DOUBLE True
Subtype: Electric Distributed Generation: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A polygon defining a generation facility of unknow type Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
21 Battery A polygon feature generation facility that uses a battery to store electricity Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
22 Biomass A polygon feature generation facility that uses biomass to create electricity Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
24 Gas Turbine A polygon feature generation facility that uses Natural Gas driven turbine to create electricity Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
25 Geothermal A polygon feature generation facility that uses Natural Geothermal driven turbine to create electricity Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
26 Hydro A polygon feature generation facility that uses Water to create electricity Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
28 Photovoltaic Solar A polygon feature generation facility that uses a series of Photovolic Panels to create electricity Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
29 Thermal Solar A polygon feature generation facility that uses a series of Thermal solar technology to create electricity Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
30 Wind A polygon feature generation facility that uses a series of wind turbine technology to create electricity Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Electric Substation Boundary
Electric Substation Boundary features are polygon features that outline of a Substation.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Boundary_Electric_Substation_Boundary False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
name Name TEXT (64) True
notes General Notes TEXT (2000) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
devicecount Contained Count SHORT True
installdate Install Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
assetid Asset ID TEXT (64) True
maintby Maintained By SHORT 1 Asset_Manager True
materialcode materialcode SHORT Electric_Structure_Boundary_Switchgear_Material True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
shape_area SHAPE_Area DOUBLE True
Subtype: Electric Substation Boundary: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A polygon used to define the outline of a station of unknown type Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
82 Distribution Substation A polygon used to represent the location of a Distribution Substation Single terminal ['E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
83 Transmission Substation A polygon used to define the outline of a Transmission Substation Single terminal ['E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
84 Transmission Switching Station A polygon used to define the outline of a Transmission Switching station Single terminal ['E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
85 Distribution Switching Station A polygon used to represent the location of a Distribution Switching Station Single terminal ['E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
86 Secondary Station A polygon used to represent the outline of a low voltage substation Single terminal ['E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
87 Subtransmission Substation A polygon used to show the outline of a Subtransmission station Single terminal ['E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
88 Transmission Metering Station Single terminal ['E:Station'] NONE DO_NOT_SPLIT END_VERTEX
89 Transmission Terminal Station Single terminal ['E:Station'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Electric Storage Facility Boundary
Electric Storage Boundary features are polygon features that outline of a storage area, like a lake.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Boundary_Electric_Storage_Facility_Boundary False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
notes General Notes TEXT (2000) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
devicecount Contained Count SHORT True
installdate Install Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
assetid Asset ID TEXT (64) True
maintby Maintained By SHORT 1 Asset_Manager True
materialcode materialcode SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
shape_area SHAPE_Area DOUBLE True
Subtype: Electric Storage Facility Boundary: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A polygon feature representing the outline of a storage facility used to house spare electrical equipment Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
121 Warehouse A polygon feature representing the outline of a storage facility used to house spare electrical equipment that is in a building Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
122 Yard A polygon feature representing the outline of a storage facility used to house spare electrical equipment that is open air Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Wire Cabinet Boundary
Wire Cabinet Boundary features are polygon features that outline of a cabinet.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Boundary_Wire_Cabinet_Boundary False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
notes General Notes TEXT (2000) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
devicecount Contained Count SHORT True
installdate Install Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
assetid Asset ID TEXT (64) True
maintby Maintained By SHORT 1 Asset_Manager True
materialcode materialcode SHORT Wire_Structure_Junction_Cabinet_Material True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
shape_area SHAPE_Area DOUBLE True
Subtype: Wire Cabinet Boundary: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Cabinet Boundary. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
40 Cabinet Boundary The outline or boundary of a wire cabinet Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Wire Vault Boundary
Wire Vault Boundary features are polygon features that outline of a Vault.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Boundary_Communications_Wire_Vault_Boundary False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
notes General Notes TEXT (2000) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
devicecount Contained Count SHORT True
installdate Install Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
assetid Asset ID TEXT (64) True
maintby Maintained By SHORT 1 Asset_Manager True
materialcode materialcode SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
shape_area SHAPE_Area DOUBLE True
Subtype: Wire Vault Boundary: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Wire Stock Sites. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
1 Vault Boundary The outline of an equipment Vault Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
3 Vault Wall The outline of the wall of an equipment Vault used in Butterfly and cross section diagrams Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
4 Vault Floor The outline of the floor of an equipment Vault used in Butterfly and cross section diagrams Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
5 Vault Knockout The outline of the Duct entry location in an equipment Vault used in Butterfly and cross section diagrams Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
6 Manhole The outline or boundary of a manhole chamber. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Electric Switchgear Boundary
Electric Switchgear Boundary features are polygon features that outline of a Switchgear and contain the electric equipment used in the switch.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Boundary_Electric_Switchgear_Boundary False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
notes General Notes TEXT (2000) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
devicecount Contained Count SHORT True
installdate Install Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
assetid Asset ID TEXT (64) True
maintby Maintained By SHORT 1 Asset_Manager True
materialcode materialcode SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
shape_area SHAPE_Area DOUBLE True
Subtype: Electric Switchgear Boundary: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A polygon used to show the outline of a switchgear used in an unknown part of the system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
161 Medium Voltage Switchgear A polygon used to show the outline of a switchgear used in the medium voltage system Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
162 High Voltage Switchgear A polygon used to show the outline of a switchgear used in the high voltage system Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Electric Bay Boundary
Electric Bay Boundary features are polygon features that outline a grouping of related electric features, but there is no structure that accomplishes this.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Boundary_Electric_Bay_Boundary False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
notes General Notes TEXT (2000) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
devicecount Contained Count SHORT True
installdate Install Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
assetid Asset ID TEXT (64) True
maintby Maintained By SHORT 1 Asset_Manager True
materialcode materialcode SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
shape_area SHAPE_Area DOUBLE True
Subtype: Electric Bay Boundary: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Wire micro duct Connection Point. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
201 Switchgear Bay A outline of an internal compartment of switch gear or switch cabinet Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
202 Substation Bay A polygon used to show a grouping of lines and devices that are associated with a Circuit Breaker. Single terminal ['E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Electric Zone
An electrical area that can be used for managing switching or saftey
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Boundary_Electric_Zone False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Supported subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
name Name TEXT (64) True
notes General Notes TEXT (2000) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
installdate Install Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
assetid Asset ID TEXT (64) True
maintby Maintained By SHORT 1 Asset_Manager True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
shape_area SHAPE_Area DOUBLE True
Subtype: Electric Zone: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A electrically connect group of equipment used for an unknown purpose Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
561 Protection Zone A electrically connect group of equipment used in providing protection Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
562 Switching Zone A electrically connect group of equipment used in switching a subsection of a circuit Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Building
A structure used for commercial purposes
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Boundary_Building False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
name Name TEXT (64) True
notes General Notes TEXT (2000) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
installdate Install Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
assetid Asset ID TEXT (64) True
maintby Maintained By SHORT 1 Asset_Manager True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
shape_area SHAPE_Area DOUBLE True
Subtype: Building: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Building. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
801 Building A polygon defining the outline of a building Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
802 Room The polygon defining the outline of a room in a building Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
803 Roof Covering The polygon defining the outline of a roof typically used in siting Photovolic solar panels Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
804 Generation Power House Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
805 Generation Control Center Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Support
Various support structures used to represent things like Culverts and Bridges
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Boundary_Support False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
name Name TEXT (64) True
notes General Notes TEXT (2000) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
installdate Install Date DATE True
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
assetid Asset ID TEXT (64) True
maintby Maintained By SHORT 1 Asset_Manager True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
shape_area SHAPE_Area DOUBLE True
Subtype: Support: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Support. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
815 Bridge Unknown type of Ground. Single terminal ['Wire Aerial Support Structure'] CONTAINER DO_NOT_SPLIT END_VERTEX
816 Casing A protective structure used around electrical or communications cables Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
817 Culvert Unknown type of Wire Stock Sites. Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
818 Duct Unknown type of Building. Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
819 Foundation Unknown type of Support. Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
820 Pad Unknown type of Wire Conduit Fittings. Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
821 Path - Marine A polygon defining the path of a marine or submersible cable Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
822 Path - On Ground A polygon defining the path of a underground cables Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
823 Path - Overhead A polygon defining the path of a overhead cables Single terminal ['E:Cable - Overhead'] CONTAINER DO_NOT_SPLIT END_VERTEX
824 Path - Trench A polygon defining the path of a trench Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX

StructureJunction

The Structure Junction feature class represents features which are tracked in a utility's asset inventory system. A structure junction can be either a structural feature that a device is attached to or a container of devices.
Class Details
DatasetType ShapeType Alias Has Attachment
FEATURE_CLASS SIMPLE StructureJunction True
Fields
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG 0 False
assettype Asset type SHORT 0 False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
dimensions Size/Diameter SHORT True
materialcode Material Code and Description SHORT Wire_Structure_Junction_Combined_Material True
height Height SHORT Wire_Pole_Height_Combined True
district District TEXT (255) True
treatment Pole Treatment Type SHORT True
depth Depth DOUBLE True
equipmenttypeorclass Class/Type SHORT True
indicatortypefield Type of Marker SHORT True
lowvoltagerisercount Number of Low Voltage Risers SHORT True
mediumvoltagerisercount Number of Medium Voltage Risers SHORT True
highvoltagerisercount Number of High Voltage Risers SHORT True
grounded Structure Grounded SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status_Combined False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
diameter Diameter DOUBLE True
ductcounthigh Ducts High, Ports High SHORT True
ductcountwide Ducts Wide, Ports Wide SHORT True
wallid Wall ID SHORT Structure_Wall_Position True
numberofwall Number of Walls SHORT True
usedcapacity Ducts Used, Ports Used SHORT True
availablecapacity Ducts Open, Ports Open SHORT True
foundationtype Type of Foundation SHORT True
designtype Type SHORT True
manufacturer Manufacturer SHORT True
height_metric Height SHORT True
depth_metric Depth DOUBLE True
diameter_metric Diameter DOUBLE True
created_user created_user TEXT (255) True
created_date created_date DATE True
last_edited_user last_edited_user TEXT (255) True
last_edited_date last_edited_date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
supportedequipmenttype Mounted Equipment Types SHORT Electric_Supported_Equipment_Type_All True
Subtypes
Code Name Description
0 Unknown The Unknown asset group in the StructureJunction feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it.
135 Electric Station A fence or gate surrounding critical facilities to maintain safety and security.
101 Wire Cabinet The Wire Cabinet is intended for use for containing non-switch and non-transformer pad mounted equipment such as capacitor controllers.
102 Wire Structure Guy An Wire Guy is a tensioned cable with anchor designed to add stability to a pole.
103 Wire Handhole The Wire Handhole represents an access box frequently used to access low voltage or service conductors.
104 Wire Junction Box The Wire Junction box is typically a water tight surface structure used for low voltage connections.
105 Wire Vault Access Point An Wire Manhole.
110 Wire Vault Wire Vaults are typically concrete rooms that will contain surface mounted equipment, like transformers.
107 Wire Pedestal Wire Pedestal are typically short vertical structures typically used to mount a customer meter devices on.
106 Electric Pad An Electric Pad, typically placed under surface mounted equipment and cabinets, like transformers and switchgear. This feature would typically have an association to container feature that is placed on the pad.
108 Electric Platform Electric Platforms are structures typically placed between two or more poles to support heavier electrical equipment.
112 Electric Bay Electric Bay is not a physical structure, but provides a way to "group" equipment together in when the equipment is placed in close proximity, but needs to be logically separated.
120 Electric High Voltage Pole Electric High Voltage Poles are vertical support structures used to support High Voltage or Transmission lines. Medium Voltage and Low Voltage equipment can be associated this feature type.
121 Electric Medium Voltage Pole Electric Medium Voltage Poles are vertical support structures used to support Medium Voltage or Distribution lines. Medium Voltage and Low Voltage equipment can be associated this feature type, but High Voltage equipment cannot be associated with this structure type.
122 Electric Low Voltage Pole Electric Low Voltage Poles are vertical support structures used to support Low lines. Low Voltage equipment can be associated this feature type, but High Voltage and Medium Voltage equipment cannot be associated with this structure type.
123 Wire Support Pole Wire Support Poles are Vertical support structures typically used to "Brace" an other pole when a Anchor Guy cannot be used to support it.
111 Communications Tower The Communications Tower asset group in the StructureJunction feature class are used to represent Towers owned or used by communications companies.
125 Communications Pole The Communications Poles asset group in the StructureJunction feature class are used to represent Poles owned or used by communications companies.
124 Marker Markers are types of structures used to warn of the location of power lines. These are frequently used for high voltage power lines or where medium voltage or higher voltage lines cross water bodies where boat booms could potentially come in contact with power lines.
132 Wire Structure Representation Wire Structure Represtations are features used in the creation of Cross Section and Butterfly diagrams used to help illistrate underground structures, such as Vaults and Maholes.
130 Wire Vault Knockouts The Wire Vault Knockouts asset group in the StructureJunction feature class used to represent a Duct Bank knockout found inside a Handhole, Manhole or Vault.
134 Duct Junctions A collection of features used to connect Ducts and Duct Banks
126 Wire Conduit Fittings Fittings used for connecting Conduits
113 Wire Customer Attachment The Wire Customer Attachment asset group in the StructureJunction feature class is used to represent the location of the Structureal attachment to a customer premise.
133 Structure Attachment Point The Structure Attachment Point asset group in the StructureJunction feature class is used to provide a utility network attachment association between structure features.
801 Ground A junction used as a Ground, such as a Ground Rod
136 Wire Stock Sites Locations where a utility would store equipment
802 Building A structure used for commercial purposes
803 Support Various support structures used to represent things like Culverts and Bridges
137 Building Riser vertical riser ducts, pipes or conduits used to deliver fluid, gas, or electrical signals or power upward
804 Foundation
114 Transition Point
145 Wire Crossarm
Subtype: Unknown
The Unknown asset group in the StructureJunction feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 UtilityNetwork_5_UnknownAssetType False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname SubnetworkName TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
district District TEXT (255) True
grounded Structure Grounded SHORT True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Unknown: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Structure points of unknown type, typically only used during data migration. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Electric Station
A fence or gate surrounding critical facilities to maintain safety and security.
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Junction_Electric_Station False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
district District Location TEXT (255) True
grounded Structure Grounded SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Electric Station: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A Point representing the location of a Electric Station Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
82 Distribution Substation A point used to represent the location of a Distribution Substation Single terminal ['E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
83 Transmission Substation A point representing the location of a Transmission Substation Single terminal ['E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
84 Transmission Switching Station A point representing the location of a Transmission Switching Station Single terminal ['E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
85 Distribution Switching Station A point used to represent the location of a Distribution Switching Station Single terminal ['E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
86 Secondary Station A point used to represent the location of a Secondary station Single terminal ['E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
87 Subtransmission Substation A point representing the location of a Subtransmission Substation Single terminal ['E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
88 Transmission Metering Station Single terminal ['E:Station'] NONE DO_NOT_SPLIT END_VERTEX
89 Transmission Terminal Station Single terminal ['E:Station'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Wire Cabinet
The Wire Cabinet is intended for use for containing non-switch and non-transformer pad mounted equipment such as capacitor controllers.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Junction_Wire_Cabinet False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
dimensions Size SHORT Wire_Structure_Junction_Cabinet_Size True
materialcode Material Code and Description SHORT Wire_Structure_Junction_Cabinet_Material True
district District Location TEXT (255) True
grounded Structure Grounded SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
designtype Design Type SHORT Wire_Structure_Cabinet_Design_Type True
manufacturer Structure Manufacturer SHORT Wire_Structure_Manufacturer True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Wire Cabinet: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Wire Cabinet. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
101 Electric Cabinet A cabinet used for containing wire devices, junctions, and busbars. Single terminal ['Cable Support'] CONTAINER DO_NOT_SPLIT END_VERTEX
102 Communication Cabinet A cabinet used for containing communications devices and junctions. Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Wire Structure Guy
An Wire Guy is a tensioned cable with anchor designed to add stability to a pole.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Junction_Wire_Guy False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
dimensions Size SHORT Wire_Structure_Junction_Anchor_Guy_Size True
materialcode Material Code and Description SHORT Wire_Structure_Junction_Guy_Material True
district District Location TEXT (255) True
depth Depth DOUBLE Wire_Anchor_Guy_Depth True
equipmenttypeorclass Type SHORT Wire_Structure_Junction_Anchor_Guy_Type True
grounded Structure Grounded SHORT True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
diameter Diameter DOUBLE Wire_Structure_Guy_Diameter_in True
foundationtype Type of Foundation SHORT True
manufacturer Structure Manufacturer SHORT Wire_Structure_Manufacturer True
diameter_metric Diameter DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Wire Structure Guy: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Wire Guy. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
41 Anchor Guy An wire Anchor Guy structure used to help provide support for the upper portion of a pole. Sometimes referred to as a down guy. Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Wire Handhole
The Wire Handhole represents an access box frequently used to access low voltage or service conductors.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Junction_Wire_Handhole False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
dimensions Size SHORT Wire_Structure_Junction_Handhole_Size True
materialcode Material Code and Description SHORT Wire_Structure_Junction_Handhole_Material True
district District Location TEXT (255) True
depth Depth DOUBLE True
grounded Structure Grounded SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
manufacturer Structure Manufacturer SHORT Wire_Structure_Manufacturer True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Wire Handhole: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Wire Manhole. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
81 Handhole An wire Handhole represents an access box frequently used to access low voltage or service conductors. Single terminal ['Cable Support', 'Duct Trace'] STRUCTURE DO_NOT_SPLIT END_VERTEX
Subtype: Wire Junction Box
The Wire Junction box is typically a water tight surface structure used for low voltage connections.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Junction_Wire_Junction_Box False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
dimensions Size SHORT Wire_Structure_Junction_Junction_Box_Size True
materialcode Material Code and Description SHORT Wire_Structure_Junction_Junction_Box_Material True
height Height SHORT True
district District Location TEXT (255) True
depth Depth DOUBLE True
grounded Structure Grounded SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
manufacturer Structure Manufacturer SHORT Wire_Structure_Manufacturer True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Wire Junction Box: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Wire Junction Box. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
121 Junction Box An wire Junction box is typically a water tight surface structure used for low voltage connections. Single terminal ['Cable Support'] STRUCTURE DO_NOT_SPLIT END_VERTEX
Subtype: Wire Vault Access Point
An Wire Manhole.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Junction_Wire_Vault_Access False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
dimensions Size SHORT Wire_Structure_Junction_Manhole_Size True
materialcode Material Code and Description SHORT Wire_Structure_Junction_Vault_Cover_Material True
district District Location TEXT (255) True
depth Depth DOUBLE True
equipmenttypeorclass Manhole Type SHORT Wire_Structure_Junction_Manhole_Type True
grounded Structure Grounded SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
foundationtype Type of Foundation SHORT True
manufacturer Structure Manufacturer SHORT Wire_Structure_Manufacturer True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Wire Vault Access Point: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Wire Manhole. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
161 Manhole Cover An Wire Manhole. Single terminal ['Cable Support', 'Duct Trace'] STRUCTURE DO_NOT_SPLIT END_VERTEX
Subtype: Wire Vault
Wire Vaults are typically concrete rooms that will contain surface mounted equipment, like transformers.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Junction_Wire_Vault False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
dimensions Size SHORT Wire_Structure_Junction_Vault_Size True
materialcode Material Code and Description SHORT Wire_Structure_Junction_Vault_Material True
district District Location TEXT (255) True
depth Depth DOUBLE Wire_Vault_Depth True
equipmenttypeorclass Vault Type SHORT Wire_Structure_Junction_Manhole_Type True
grounded Structure Grounded SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
wallid Wall ID SHORT 0 Structure_Wall_Position True
numberofwall Number of Walls SHORT Structure_Wall_Count True
foundationtype Type of Foundation SHORT True
manufacturer Structure Manufacturer SHORT Wire_Structure_Manufacturer True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Wire Vault: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Vault. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
361 Vault An Wire Vaults is typically a concrete room that will contain surface mounted equipment, like transformers. Single terminal ['Cable Support', 'Duct Trace'] CONTAINER DO_NOT_SPLIT END_VERTEX
362 Manhole Access point for underground assets Single terminal ['Cable Support', 'Duct Trace'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Wire Pedestal
Wire Pedestal are typically short vertical structures typically used to mount a customer meter devices on.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Junction_Wire_Pedestal False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
materialcode Material Code and Description SHORT Wire_Structure_Junction_Pedestal_Material True
district District Location TEXT (255) True
depth Depth DOUBLE Wire_Pedestal_Depth True
grounded Structure Grounded SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
foundationtype Type of Foundation SHORT True
manufacturer Structure Manufacturer SHORT Wire_Structure_Manufacturer True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Wire Pedestal: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Wire Pedestal Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
241 Pedestal An Wire Pedestal is typically a short vertical structures typically used to mount a customer meter devices on. Single terminal ['Cable Support'] STRUCTURE DO_NOT_SPLIT END_VERTEX
Subtype: Electric Pad
An Electric Pad, typically placed under surface mounted equipment and cabinets, like transformers and switchgear. This feature would typically have an association to container feature that is placed on the pad.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Junction_Electric_Pad False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
dimensions Size SHORT Electric_Structure_Junction_Pad_Size True
materialcode Material Code and Description SHORT Electric_Structure_Junction_Pad_Material True
district District Location TEXT (255) True
grounded Structure Grounded SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
foundationtype Type of Foundation SHORT True
manufacturer Structure Manufacturer SHORT Wire_Structure_Manufacturer True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Electric Pad: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Electric Pad. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
201 Pad An Electric Pad, typically placed under surface mounted equipment and cabinets, like transformers and switchgear. This feature would typically have an association to container feature that is placed on the pad. Single terminal ['Cable Support'] STRUCTURE DO_NOT_SPLIT END_VERTEX
Subtype: Electric Platform
Electric Platforms are structures typically placed between two or more poles to support heavier electrical equipment.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Junction_Electric_Platform False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
dimensions Size SHORT Electric_Structure_Junction_Platform_Size True
materialcode Material Code and Description SHORT Electric_Structure_Junction_Platform_Material True
height Platform Height SHORT True
district District Location TEXT (255) True
grounded Structure Grounded SHORT True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
manufacturer Structure Manufacturer SHORT Wire_Structure_Manufacturer True
height_metric Height SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Electric Platform: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Electric Platform. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
281 Platform A structure typically placed between two or more poles to support heavier electrical equipment. Single terminal ['Cable Support'] STRUCTURE DO_NOT_SPLIT END_VERTEX
Subtype: Electric Bay
Electric Bay is not a physical structure, but provides a way to "group" equipment together in when the equipment is placed in close proximity, but needs to be logically separated.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Junction_Electric_Bay False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
district District Location TEXT (255) True
grounded Structure Grounded SHORT True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Electric Bay: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Electric Bay. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
441 Cabinet Bay A Cabinet Bay can be a compartment inside a switchgear cabinet that allows devices to be group together inside the cabinet and allows labeling on the grouping as opposed to the individual features. Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
442 Substation Bay A Substation Bay is a grouping of lines and devices that are associated with a Circuit Breaker. Single terminal ['E:Station'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Electric High Voltage Pole
Electric High Voltage Poles are vertical support structures used to support High Voltage or Transmission lines. Medium Voltage and Low Voltage equipment can be associated this feature type.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Junction_Electric_High_Voltage_Pole False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
materialcode Material Code and Description SHORT Electric_Structure_Junction_High_Voltage_Pole_Material True
height Pole Height SHORT Electric_High_Voltage_Pole_Height True
district District Location TEXT (255) True
treatment Pole Treatment Type SHORT 0 Wire_Structure_Junction_Pole_Treatment_Type True
depth Depth DOUBLE Electric_High_Voltage_Pole_Depth True
equipmenttypeorclass Pole Class SHORT Electric_Structure_Pole_Class_High_Voltage True
lowvoltagerisercount Number of Low Voltage Risers SHORT True
mediumvoltagerisercount Number of Medium Voltage Risers SHORT True
highvoltagerisercount Number of High Voltage Risers SHORT True
grounded Structure Grounded SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
foundationtype Type of Foundation SHORT Wire_Structure_Junction_Foundation True
manufacturer Structure Manufacturer SHORT Wire_Structure_Manufacturer True
height_metric Height SHORT Electric_High_Voltage_Pole_Height_metric True
depth_metric Depth DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Electric High Voltage Pole: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A Pole of Unknown type primarily used to support high voltage cables Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
330 Single Circuit Lattice HV A Single Circuit Lattice structure primarily used to support high voltage cables Single terminal ['Asset Location', 'Cable Support', 'Wire Aerial Support Structure'] STRUCTURE DO_NOT_SPLIT END_VERTEX
331 Dual Circuit Lattice HV A Dual Circuit Lattice structure primarily used to support high voltage cables Single terminal ['Asset Location', 'Cable Support', 'Wire Aerial Support Structure'] STRUCTURE DO_NOT_SPLIT END_VERTEX
332 Triple Circuit Lattice HV A Triple Circuit Lattice structure primarily used to support high voltage cables Single terminal ['Asset Location', 'Cable Support', 'Wire Aerial Support Structure'] STRUCTURE DO_NOT_SPLIT END_VERTEX
333 Quadruple Circuit Lattice HV A Quadruple Circuit Lattice structure primarily used to support high voltage cables Single terminal ['Asset Location', 'Cable Support', 'Wire Aerial Support Structure'] STRUCTURE DO_NOT_SPLIT END_VERTEX
334 Gantry HV Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
335 H-Frame HV Single terminal ['Asset Location', 'Cable Support', 'Wire Aerial Support Structure'] STRUCTURE DO_NOT_SPLIT END_VERTEX
336 Pole with Riser HV Single terminal ['Asset Location', 'Cable Support', 'Wire Aerial Support Structure'] NONE DO_NOT_SPLIT END_VERTEX
337 Pole HV Single terminal ['Asset Location', 'Cable Support', 'Wire Aerial Support Structure'] STRUCTURE DO_NOT_SPLIT END_VERTEX
Subtype: Electric Medium Voltage Pole
Electric Medium Voltage Poles are vertical support structures used to support Medium Voltage or Distribution lines. Medium Voltage and Low Voltage equipment can be associated this feature type, but High Voltage equipment cannot be associated with this structure type.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Junction_Electric_Medium_Voltage_Pole False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
materialcode Material Code and Description SHORT Electric_Structure_Junction_Medium_Voltage_Pole_Material True
height Pole Height SHORT Electric_Medium_Voltage_Pole_Height True
district District Location TEXT (255) True
treatment Pole Treatment Type SHORT 0 Wire_Structure_Junction_Pole_Treatment_Type True
depth Depth DOUBLE Electric_Medium_Voltage_Pole_Depth True
equipmenttypeorclass Pole Class SHORT Electric_Structure_Pole_Class_Medium_Voltage True
lowvoltagerisercount Number of Low Voltage Risers SHORT True
mediumvoltagerisercount Number of Medium Voltage Risers SHORT True
grounded Structure Grounded SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
foundationtype Type of Foundation SHORT Wire_Structure_Junction_Foundation True
manufacturer Structure Manufacturer SHORT Wire_Structure_Manufacturer True
height_metric Height SHORT Electric_Medium_Voltage_Pole_Height_metric True
depth_metric Depth DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Electric Medium Voltage Pole: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A Pole of unknown type used to support aerial cables in the medium voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
321 H-Frame MV A two pole structure used to support aerial cables in the medium voltage system Single terminal ['Asset Location', 'Cable Support', 'Wire Aerial Support Structure'] STRUCTURE DO_NOT_SPLIT END_VERTEX
323 Pole with Riser MV A Pole that has one or more risers attached to it used to support aerial cables in the medium voltage system Single terminal ['Asset Location', 'Cable Support', 'Wire Aerial Support Structure'] STRUCTURE DO_NOT_SPLIT END_VERTEX
324 Pole MV A Pole used to support aerial cables in the medium voltage system Single terminal ['Asset Location', 'Cable Support', 'Wire Aerial Support Structure'] STRUCTURE DO_NOT_SPLIT END_VERTEX
329 Lattice MV A reinforced structure, typically steel, used to support aerial cables in the medium voltage system Single terminal ['Asset Location', 'Cable Support', 'Wire Aerial Support Structure'] STRUCTURE DO_NOT_SPLIT END_VERTEX
Subtype: Electric Low Voltage Pole
Electric Low Voltage Poles are vertical support structures used to support Low lines. Low Voltage equipment can be associated this feature type, but High Voltage and Medium Voltage equipment cannot be associated with this structure type.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Junction_Electric_Low_Voltage_Pole False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
materialcode Material Code and Description SHORT Electric_Structure_Junction_Low_Voltage_Pole_Material True
height Pole Height SHORT Electric_Low_Voltage_Pole_Height True
district District Location TEXT (255) True
treatment Pole Treatment Type SHORT 0 Wire_Structure_Junction_Pole_Treatment_Type True
depth Depth DOUBLE Electric_Medium_Voltage_Pole_Depth True
equipmenttypeorclass Pole Class SHORT Electric_Structure_Pole_Class_Low_Voltage True
lowvoltagerisercount Number of Low Voltage Risers SHORT True
grounded Structure Grounded SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
foundationtype Type of Foundation SHORT Wire_Structure_Junction_Foundation True
manufacturer Structure Manufacturer SHORT Wire_Structure_Manufacturer True
height_metric Height SHORT Electric_Low_Voltage_Pole_Height_metric True
depth_metric Depth DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Electric Low Voltage Pole: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A Pole of unknown type that is used to support cables in the low voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
313 Pole with Riser LV Single terminal ['Asset Location', 'Cable Support', 'Wire Aerial Support Structure'] STRUCTURE DO_NOT_SPLIT END_VERTEX
314 Pole LV Single terminal ['Asset Location', 'Cable Support', 'Wire Aerial Support Structure'] STRUCTURE DO_NOT_SPLIT END_VERTEX
315 Ornamental LV Single terminal ['Asset Location', 'Cable Support', 'Wire Aerial Support Structure'] STRUCTURE DO_NOT_SPLIT END_VERTEX
319 Lattice LV Single terminal ['Asset Location', 'Cable Support', 'Wire Aerial Support Structure'] STRUCTURE DO_NOT_SPLIT END_VERTEX
Subtype: Wire Support Pole
Wire Support Poles are Vertical support structures typically used to "Brace" an other pole when a Anchor Guy cannot be used to support it.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Junction_Wire_Support_Pole False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
materialcode Material Code and Description SHORT Wire_Structure_Junction_Support_Pole_Material True
height Pole Height SHORT Wire_Structure_Junction_Support_Pole_Height True
district District Location TEXT (255) True
treatment Pole Treatment Type SHORT Wire_Structure_Junction_Pole_Treatment_Type True
depth Depth DOUBLE Wire_Support_Pole_Depth True
equipmenttypeorclass Pole Class SHORT Wire_Structure_Junction_Support_Pole_Class True
grounded Structure Grounded SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
foundationtype Type of Foundation SHORT Wire_Structure_Junction_Foundation True
manufacturer Structure Manufacturer SHORT Wire_Structure_Manufacturer True
height_metric Height SHORT Wire_Structure_Junction_Support_Pole_Height_metric True
depth_metric Depth DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Wire Support Pole: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Wire Support Pole. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
326 Stub An Wire Support Stub structure used to pull an aerial support cable attached to a larger medium voltage pole or to reinforce the base of a larger medium voltage pole. Single terminal ['Asset Location'] STRUCTURE DO_NOT_SPLIT END_VERTEX
327 Push Brace An Wire Support Push Brace structure used to push against a medium voltage pole when an anchor guy cannot be used. Single terminal ['Asset Location'] STRUCTURE DO_NOT_SPLIT END_VERTEX
328 Support Column Wire Support Poles are Vertical support structures typically used to "Brace" an other pole when a Anchor Guy cannot be used to support it. Single terminal [] STRUCTURE DO_NOT_SPLIT END_VERTEX
Subtype: Communications Tower
The Communications Tower asset group in the StructureJunction feature class are used to represent Towers owned or used by communications companies.
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Junction_Communications_Tower False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
dimensions Size SHORT True
materialcode Material Code and Description SHORT True
height Height SHORT True
district District Location TEXT (255) True
treatment Pole Treatment Type SHORT True
depth Depth DOUBLE True
equipmenttypeorclass Type SHORT True
indicatortypefield Type of Marker SHORT True
lowvoltagerisercount Number of Low Voltage Risers SHORT True
mediumvoltagerisercount Number of Medium Voltage Risers SHORT True
highvoltagerisercount Number of High Voltage Risers SHORT True
grounded Structure Grounded SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
diameter Diameter DOUBLE True
availablecapacity Ducts Open SHORT True
foundationtype Type of Foundation SHORT True
designtype Design Type SHORT Communications_Wireless_Tower_Type True
manufacturer Structure Manufacturer SHORT True
height_metric Height SHORT True
depth_metric Depth DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Communications Tower: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Communications Tower Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
221 Microwave Tower A feature used to represent the location of a tower used to support only Microwaves antennas. Single terminal ['Asset Location', 'Cable Support'] STRUCTURE DO_NOT_SPLIT END_VERTEX
222 Wireless Tower A feature used to represent the location of a tower used to support only Cell antennas. Single terminal ['Asset Location', 'Cable Support'] STRUCTURE DO_NOT_SPLIT END_VERTEX
223 Combined Tower A feature used to represent the location of a tower used to support Cell antennas and Microwave antennas. Single terminal ['Asset Location', 'Cable Support'] STRUCTURE DO_NOT_SPLIT END_VERTEX
224 Stealth Cell Tower A feature used to represent the location of a tower that is disguised in some fashion used to support Cell antennas. Single terminal ['Asset Location', 'Cable Support'] STRUCTURE DO_NOT_SPLIT END_VERTEX
Subtype: Communications Pole
The Communications Poles asset group in the StructureJunction feature class are used to represent Poles owned or used by communications companies.
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Junction_Communications_Pole False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
materialcode Material Code and Description SHORT Wire_Structure_Junction_Comm_Pole_Material True
height Pole Height SHORT Structure_Junction_Communications_Pole_Height True
district District Location TEXT (255) True
treatment Pole Treatment Type SHORT Wire_Structure_Junction_Pole_Treatment_Type True
depth Depth DOUBLE Structure_Pole_Depth True
equipmenttypeorclass Pole Class SHORT Wire_Structure_Junction_Pole_Class_Combined True
lowvoltagerisercount Number of Low Voltage Risers SHORT True
mediumvoltagerisercount Number of Medium Voltage Risers SHORT True
highvoltagerisercount Number of High Voltage Risers SHORT True
grounded Structure Grounded SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
foundationtype Type of Foundation SHORT True
designtype Design Type SHORT True
manufacturer Structure Manufacturer SHORT Wire_Structure_Manufacturer True
height_metric Height SHORT Structure_Junction_Communications_Pole_Height_metric True
depth_metric Depth DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Communications Pole: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Communications Pole. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
581 Pole A feature used to represent a Pole used for supporting only communications cables and equipment. Single terminal ['Asset Location', 'Cable Support', 'Wire Aerial Support Structure'] STRUCTURE DO_NOT_SPLIT END_VERTEX
582 Pole with Riser Single terminal ['Asset Location', 'Cable Support', 'Wire Aerial Support Structure'] STRUCTURE DO_NOT_SPLIT END_VERTEX
Subtype: Marker
Markers are types of structures used to warn of the location of power lines. These are frequently used for high voltage power lines or where medium voltage or higher voltage lines cross water bodies where boat booms could potentially come in contact with power lines.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Junction_Marker False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
materialcode Material Code and Description SHORT Wire_Structure_Junction_Maker_Material True
height Marker Height SHORT True
district District Location TEXT (255) True
indicatortypefield Type of Marker SHORT True
grounded Structure Grounded SHORT True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
foundationtype Type of Foundation SHORT True
manufacturer Structure Manufacturer SHORT Wire_Structure_Manufacturer True
height_metric Marker Height (metric) SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Marker: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Marker. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
461 Aerial Marker An aerial marker for overhead wires. Single terminal ['Asset Location'] STRUCTURE DO_NOT_SPLIT END_VERTEX
462 Buried Cable Marker A location marker and warning for buried cables. Single terminal ['Asset Location'] STRUCTURE DO_NOT_SPLIT END_VERTEX
463 Overhead Water Crossing A water crossing marker and warning for overhead cables over bodies of water. Single terminal ['Asset Location', 'E:Cable - Overhead'] STRUCTURE DO_NOT_SPLIT END_VERTEX
464 Submerged Cable Marker A marker used to indicate submerged cables at this location, typically found in large bodies of water. Single terminal ['Asset Location'] STRUCTURE DO_NOT_SPLIT END_VERTEX
465 Covered Marker A location marker and warning for buried cables. Single terminal ['Asset Location'] NONE DO_NOT_SPLIT END_VERTEX
466 Terrain Marker A surface marker used to make cables Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Wire Structure Representation
Wire Structure Represtations are features used in the creation of Cross Section and Butterfly diagrams used to help illistrate underground structures, such as Vaults and Maholes.
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Junction_Wire_Structure_Representation False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Wire Structure Representation: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Structural Representation. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
375 Butterfly Diagram A feature used to specify the location of a butterfly diagram used in the underground structure network. Single terminal ['Cable Support'] STRUCTURE DO_NOT_SPLIT END_VERTEX
376 Cross Section A feature used to specify the location of a cross section diagram used in the underground structure network.. Single terminal ['Cable Support'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Wire Vault Knockouts
The Wire Vault Knockouts asset group in the StructureJunction feature class used to represent a Duct Bank knockout found inside a Handhole, Manhole or Vault.
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Junction_Wire_Vault_Knockouts False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
diameter Port Diameters DOUBLE True
ductcounthigh Ports High SHORT True
ductcountwide Ports Wide SHORT True
wallid Wall ID SHORT 0 Structure_Wall_Position True
usedcapacity Ports Used SHORT Wire_Number_of_Ducts True
availablecapacity Ports Open SHORT Wire_Number_of_Ducts True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Wire Vault Knockouts: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Wire Vault Knockouts Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
371 Knockout A feature used to represent the knockout found on the wall of a Vault, Manhole or Handhole. Single terminal ['Cable Support', 'Duct Trace'] STRUCTURE DO_NOT_SPLIT END_VERTEX
372 Knockout Port A feature used to represent the knockout for the duct or pipe found on the wall of a Vault, Manhole or Handhole. Single terminal ['Cable Support', 'Duct Trace'] STRUCTURE DO_NOT_SPLIT END_VERTEX
373 Cross Section Position Single terminal [] STRUCTURE DO_NOT_SPLIT END_VERTEX
Subtype: Duct Junctions
A collection of features used to connect Ducts and Duct Banks
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Junction_Duct_Junctions False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
grounded Structure Grounded SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Duct Junctions: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Duct Junctions. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
162 Aerial Microduct Branch Off Point A microduct branch mounted on a pole Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
163 Underground Microduct Branch Off Point A microduct branch buried underground Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
164 Duct Bank Tap A feature used to connect two Duct Banks together where one Duct Bank intersect the other Duct Bank at a location other than the end of the Duct Bank Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Wire Conduit Fittings
Fittings used for connecting Conduits
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Junction_Communications_Conduit_Fittings False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
constructionstatus Construction Status SHORT 6 Construction_Status False
Subtype: Wire Conduit Fittings: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Wire Conduit Fittings. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
141 Elbow A curved fitting used in conduit Single terminal ['Cable Support'] CONTAINER DO_NOT_SPLIT END_VERTEX
142 Sweep Tee A conduit fitting with two branches using a gradual curve away from the main line Single terminal ['Cable Support'] CONTAINER DO_NOT_SPLIT END_VERTEX
143 Y Splitter A type of three way joint used in conduits Single terminal ['Cable Support'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Wire Customer Attachment
The Wire Customer Attachment asset group in the StructureJunction feature class is used to represent the location of the Structureal attachment to a customer premise.
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Junction_Wire_Customer_Attachment False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
dimensions Size/Diameter SHORT True
materialcode Material Code and Description SHORT True
height Height SHORT True
district District Location TEXT (255) True
treatment Pole Treatment Type SHORT True
depth Depth DOUBLE True
equipmenttypeorclass Class/Type SHORT True
indicatortypefield Type of Marker SHORT True
lowvoltagerisercount Number of Low Voltage Risers SHORT True
mediumvoltagerisercount Number of Medium Voltage Risers SHORT True
highvoltagerisercount Number of High Voltage Risers SHORT True
grounded Structure Grounded SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
diameter Diameter DOUBLE True
ductcounthigh Ducts High SHORT True
ductcountwide Ducts Wide SHORT True
wallid Wall ID SHORT True
numberofwall Number of Walls SHORT True
usedcapacity Ducts Used SHORT True
availablecapacity Ducts Open SHORT True
foundationtype Type of Foundation SHORT True
designtype Design Type SHORT True
manufacturer Structure Manufacturer SHORT True
height_metric Height SHORT True
depth_metric Depth DOUBLE True
diameter_metric Diameter DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Wire Customer Attachment: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Wire Customer Attachment. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
242 Service Entrance A feature used to represent the cable entry location to a customer premise and provide connectivity to aerial spans and trenches. Single terminal ['Cable Pathway'] STRUCTURE DO_NOT_SPLIT END_VERTEX
Subtype: Structure Attachment Point
The Structure Attachment Point asset group in the StructureJunction feature class is used to provide a utility network attachment association between structure features.
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Junction_Structure_Attachment_Point False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Structure Attachment Point: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Structure Attachment Point. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
391 Conduit To Knockout Port A feature used to provide connectivity in the structural network to support tracing in the structure network. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Ground
A junction used as a Ground, such as a Ground Rod
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Junction_Ground False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname SubnetworkName TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
district District TEXT (255) True
depth Depth DOUBLE True
grounded Structure Grounded SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
designtype Ground Type SHORT True
manufacturer Manufacturer SHORT True
depth_metric Depth DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Ground: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Ground. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
811 Joint Unknown type of Support. Single terminal ['E:Ground'] STRUCTURE DO_NOT_SPLIT END_VERTEX
812 Plate Unknown type of Wire Conduit Fittings. Single terminal ['E:Ground'] STRUCTURE DO_NOT_SPLIT END_VERTEX
813 Rod A grounding rod. Single terminal ['E:Ground'] STRUCTURE DO_NOT_SPLIT END_VERTEX
814 Lightning Pole Single terminal ['E:Ground'] NONE DO_NOT_SPLIT END_VERTEX
815 Lightning Rod Single terminal ['E:Ground'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Wire Stock Sites
Locations where a utility would store equipment
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Junction_Wire_Stock_Sites False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
grounded Structure Grounded SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Wire Stock Sites: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Wire Stock Sites. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
261 Central Stock Site A large site used to storing wire or communications equipment Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
262 District Stock Site A point representing a location for storing equipment Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
263 Crew Quarter Stock Site A location where equipment is stored that is also a Operations field office or Crew Quarter Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
264 Mobile Stock Site A field relocatable stock site, typically used in storm or emergency restorations Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Building
A structure used for commercial purposes
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Junction_Building False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
grounded Structure Grounded SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Building: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Building. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
801 Building A point defining the centroid of a building Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
802 Room A point representing a room in a building Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
803 Roof Covering A point defining the roof centroid of a roof, typically used in siting Photovolic solar panels Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Support
Various support structures used to represent things like Culverts and Bridges
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Junction_Support False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
grounded Structure Grounded SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
manufacturer Structure Manufacturer SHORT True
diameter_metric Diameter DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Support: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Support. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
211 Tray Single terminal ['Cable Support'] NONE DO_NOT_SPLIT END_VERTEX
212 Rack Single terminal ['Cable Support'] NONE DO_NOT_SPLIT END_VERTEX
821 Shelf Single terminal ['Cable Support'] NONE DO_NOT_SPLIT END_VERTEX
823 Brace Single terminal ['Cable Support'] NONE DO_NOT_SPLIT END_VERTEX
825 Bracket Unknown type of Wire Micro duct Fitting. Single terminal ['Cable Support', 'Wire Aerial Support Structure'] NONE DO_NOT_SPLIT END_VERTEX
826 Hanger Unknown type of Wire micro duct Connection Point. Single terminal ['Cable Support', 'Wire Aerial Support Structure'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Building Riser
vertical riser ducts, pipes or conduits used to deliver fluid, gas, or electrical signals or power upward
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT Asset_Type_Structure_Junction_Wire_Building_Riser False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
materialcode Material Code and Description SHORT True
height Height SHORT True
grounded Structure Grounded SHORT Yes_No True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
constructionstatus Construction Status SHORT 6 Construction_Status False
validationstatus Validation status SHORT 6 True
Subtype: Building Riser: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
396 Building Riser A Duct or Conduit that riser vertically in a building Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Foundation
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Junction_Foundation False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
dimensions Size/Diameter SHORT True
materialcode Material Code and Description SHORT True
height Height SHORT True
district District TEXT (255) True
treatment Pole Treatment Type SHORT True
depth Depth DOUBLE True
equipmenttypeorclass Class/Type SHORT True
indicatortypefield Type of Marker SHORT True
grounded Structure Grounded SHORT True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
diameter Diameter DOUBLE True
wallid Wall ID SHORT True
numberofwall Number of Walls SHORT True
foundationtype Type of Foundation SHORT True
designtype Type SHORT True
manufacturer Manufacturer SHORT True
height_metric Height SHORT True
depth_metric Depth DOUBLE True
diameter_metric Diameter DOUBLE True
created_user created_user TEXT (255) True
created_date created_date DATE True
last_edited_user last_edited_user TEXT (255) True
last_edited_date last_edited_date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Foundation: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
841 Foundation Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Transition Point
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Junction_Transition_Point False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
constructionstatus Construction Status SHORT 6 Construction_Status False
Subtype: Transition Point: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
168 Transition Point Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Wire Crossarm
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Junction_Crossarm False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
dimensions Size/Diameter SHORT True
materialcode Material Code and Description SHORT Wire_Crossarm_Material True
height Height SHORT True
district District TEXT (255) True
treatment Pole Treatment Type SHORT True
depth Depth DOUBLE True
equipmenttypeorclass Class/Type SHORT True
indicatortypefield Type of Marker SHORT True
grounded Structure Grounded SHORT True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
labeltext Labeling String TEXT (256) True
notes General Notes TEXT (2000) True
symbolrotation Symbol Rotation SHORT Symbol_Rotation True
maintby Maintained By SHORT 1 Asset_Manager True
diameter Diameter DOUBLE True
wallid Wall ID SHORT True
numberofwall Number of Walls SHORT True
foundationtype Type of Foundation SHORT True
designtype Type SHORT True
manufacturer Manufacturer SHORT True
height_metric Height SHORT True
depth_metric Depth DOUBLE True
diameter_metric Diameter DOUBLE True
created_user created_user TEXT (255) True
created_date created_date DATE True
last_edited_user last_edited_user TEXT (255) True
last_edited_date last_edited_date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
validationstatus Validation status SHORT 6 True
Subtype: Wire Crossarm: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
1 Dead End Single terminal ['Cable Support', 'E:Crossarm'] NONE DO_NOT_SPLIT END_VERTEX
2 Tangent Single terminal ['Cable Support', 'E:Crossarm'] NONE DO_NOT_SPLIT END_VERTEX

StructureLine

The Structure Line contain lines which carry a resource. Structure lines participating as containers can contain other structure lines.
Class Details
DatasetType ShapeType Alias Has Attachment
FEATURE_CLASS SIMPLE StructureLine True
Fields
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG 0 False
assettype Asset type SHORT 0 False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
diameter Diameter/Width DOUBLE True
materialcode Material SHORT True
distance Depth/Height DOUBLE True
labeltext Labeling String TEXT (256) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
maximumcapacity Number of Ducts SHORT True
usedcapacity Ducts Used SHORT True
availablecapacity Ducts Open SHORT True
measuredlength Measured Length DOUBLE True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status_Combined False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
designtype Type SHORT True
searchdistance Structure Search Distance DOUBLE True
diameter_metric Diameter/Width DOUBLE True
created_user Created Uuser TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
ohm Ohm DOUBLE True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtypes
Code Name Description
0 Unknown The Unknown asset group in the StructureLine feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it.
801 Ground Electric conductors used to connect to grounds
102 Wire Duct Bank An Electric Duct Bank is a container for ducts and conduit.
103 Wire Aerial Support Electric Aerial supports include Guy Wires and Bridge support type features.
104 Wire Trench An Electric Trench is an open ditch that electric wires will be buried in, typically direct bury cable.
112 Access Tunnel The Access Tunnel asset group in the StructureLine feature class is used un represent tunnels used in complex underground structures
105 Electric High Voltage Conduit Conduit, typically plastic, that are used to protect underground high voltage electric lines, for example high voltage lines may run from overhead to underground inside of conduit inside of a substation.
106 Electric Low Voltage Conduit Conduit, typically plastic, that are used to protect underground low voltage electric lines, for example the low voltage line that services residential power to a home.
107 Electric Medium Voltage Conduit Conduit, typically plastic, that are used to protect underground medium voltage electric lines, for example medium voltage lines may run from overhead to underground inside of conduit.
111 Connector Line The Connector Line asset group in the StructureLine feature class is to providen network connectivity in the structure network to facilitate tracing.
113 Electric High Voltage Cable Pathway A path for routing High Voltage electrical cable
114 Electric Medium Voltage Cable Pathway A path for routing Medium Voltage electrical cable
115 Electric Low Voltage Cable Pathway A path for routing Low Voltage electrical cable
118 Wire Microduct Pathway A path for routing Communications Micro Ducts
101 Wire Casing
124 Linear Marker
109 Communications Conduit The Communications Conduit asset group in the StructureLine feature class is used to represent Conduit used to support Communications cables.
802 Static Wire
Subtype: Unknown
The Unknown asset group in the StructureLine feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 UtilityNetwork_5_UnknownAssetType False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname SubnetworkName TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
labeltext Labeling String TEXT (256) True
measuredlength Measured Length DOUBLE True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT Construction_Status False
sectionid Section ID TEXT (2000) True
ohm Ohm Per Length DOUBLE True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Unknown: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Structure lines of unknown type, typically only used during data migration. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Ground
Electric conductors used to connect to grounds
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Line_Ground False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname SubnetworkName TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
labeltext Labeling String TEXT (256) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
measuredlength Measured Length DOUBLE True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
designtype Ground Type SHORT True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
ohm Ohm Per Length DOUBLE Electric_Ohms_per_KM True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Ground: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Ground. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
801 Bare Ground A unshielded ground cable Single terminal ['E:Ground'] CONTAINER DO_NOT_SPLIT END_VERTEX
802 Covered Ground A shielded ground cable Single terminal ['E:Ground'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Wire Duct Bank
An Electric Duct Bank is a container for ducts and conduit.
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Line_Wire_Duct_Bank False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
diameter Diameter/Width DOUBLE Wire_Duct_Bank_Width True
materialcode Material SHORT Wire_Structure_Line_Duct_Bank_Material True
labeltext Labeling String TEXT (256) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
maximumcapacity Number of Ducts SHORT Wire_Number_of_Ducts True
usedcapacity Ducts Used SHORT Wire_Number_of_Ducts True
availablecapacity Ducts Open SHORT Wire_Number_of_Ducts True
measuredlength Measured Length DOUBLE True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
designtype Design Type SHORT True
diameter_metric Diameter/Width DOUBLE Electric_Wire_Diameter_mm True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
ohm Ohm DOUBLE True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Wire Duct Bank: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Wire Duct Bank. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
81 Duct Bank An Wire Duct Bank structure used to contain a collection of ducts and provide a single symbol representation of the collection of ducts Single terminal ['Cable Support', 'Duct Bank'] CONTAINER SPLIT END_VERTEX
Subtype: Wire Aerial Support
Electric Aerial supports include Guy Wires and Bridge support type features.
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Line_Wire_Aerial_Support False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
diameter Diameter/Width DOUBLE Wire_Structure_Guy_Diameter_in True
materialcode Material SHORT Wire_Structure_Line_Aerial_Support_Material True
distance Height DOUBLE True
labeltext Labeling String TEXT (256) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
measuredlength Measured Length DOUBLE True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
designtype Design Type SHORT True
diameter_metric Diameter/Width DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
ohm Ohm DOUBLE True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Wire Aerial Support: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Wire Aerial Support. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
121 Bridge Suspension An Wire Aerial Bridge Suspension structure used to suspend cable from bridges Single terminal ['Cable Pathway', 'Cable Support', 'Wire Aerial Support Structure'] CONTAINER DO_NOT_SPLIT END_VERTEX
122 Other Suspension An Wire Other Suspension structure used to suspend cables. For example, a suspension bridge. Single terminal ['Cable Pathway', 'Cable Support', 'Wire Aerial Support Structure'] CONTAINER DO_NOT_SPLIT END_VERTEX
123 Spanguy An Wire Aerial Span guy is a linear structure used to "Pull a vertical structure". Typically used when a down guy cannot directly be used. Single terminal ['Cable Support'] CONTAINER DO_NOT_SPLIT END_VERTEX
125 Aerial Span A feature used to represent Span between two poles that can be used in finding paths for cables. Single terminal ['Cable Pathway', 'Cable Support', 'Wire Aerial Support Structure'] CONTAINER DO_NOT_SPLIT END_VERTEX
126 Communications Support Guy A feature used to represent Span Guy between two poles that can be used in finding paths for cables. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
127 Lashing Guy A feature used to represent Lasing Guy between two poles or a pole and a customer premise that can be used in finding paths for cables. Single terminal ['Cable Pathway', 'Cable Support'] NONE DO_NOT_SPLIT END_VERTEX
128 Guy Wire Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Wire Trench
An Electric Trench is an open ditch that electric wires will be buried in, typically direct bury cable.
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Line_Wire_Trench False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
diameter Diameter/Width DOUBLE Wire_Trench_Width True
materialcode Soil Type SHORT Wire_Structure_Line_Trench_Material True
distance Depth DOUBLE True
labeltext Labeling String TEXT (256) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
measuredlength Measured Length DOUBLE True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
designtype Design Type SHORT True
searchdistance Structure Search Distance DOUBLE True
diameter_metric Diameter/Width DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
ohm Ohm DOUBLE True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Wire Trench: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Wire Trench. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
101 Trench An Wire Trench structure represents an open linear pit that will have direct buried conductor place in it. Typically used during construction phase of facilities. Single terminal ['Cable Pathway', 'Cable Support'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Access Tunnel
The Access Tunnel asset group in the StructureLine feature class is used un represent tunnels used in complex underground structures
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Line_Tunnel False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
diameter Diameter/Width DOUBLE True
materialcode Soil Type SHORT True
distance Depth DOUBLE True
labeltext Labeling String TEXT (256) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
measuredlength Measured Length DOUBLE True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
designtype Design Type SHORT True
diameter_metric Diameter/Width DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
ohm Ohm DOUBLE True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Access Tunnel: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Access Tunnel. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
221 Tunnel A feature used to represent a Tunnel that can contain Communications and Electric Cables. Single terminal ['Cable Pathway', 'Cable Support'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Electric High Voltage Conduit
Conduit, typically plastic, that are used to protect underground high voltage electric lines, for example high voltage lines may run from overhead to underground inside of conduit inside of a substation.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Line_Electric_High_Voltage_Conduit False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
diameter Diameter/Width DOUBLE True
materialcode Material SHORT Wire_Structure_Line_Duct_Material True
labeltext Labeling String TEXT (256) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
measuredlength Measured Length DOUBLE True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
searchdistance Structure Search Distance DOUBLE True
diameter_metric Diameter/Width DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
ohm Ohm DOUBLE True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Electric High Voltage Conduit: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Electric High Voltage Conduit. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
114 Conduit HV Single terminal ['Cable Pathway'] CONTAINER DO_NOT_SPLIT ANY_VERTEX
Subtype: Electric Low Voltage Conduit
Conduit, typically plastic, that are used to protect underground low voltage electric lines, for example the low voltage line that services residential power to a home.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Line_Electric_Low_Voltage_Conduit False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
diameter Diameter/Width DOUBLE True
materialcode Material SHORT Wire_Structure_Line_Duct_Material True
labeltext Labeling String TEXT (256) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
measuredlength Measured Length DOUBLE True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
searchdistance Structure Search Distance DOUBLE True
diameter_metric Diameter/Width DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
ohm Ohm DOUBLE True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Electric Low Voltage Conduit: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Electric Low Voltage Conduit. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
118 Conduit LV Single terminal ['Cable Pathway'] CONTAINER DO_NOT_SPLIT ANY_VERTEX
Subtype: Electric Medium Voltage Conduit
Conduit, typically plastic, that are used to protect underground medium voltage electric lines, for example medium voltage lines may run from overhead to underground inside of conduit.
Name Alias Type Default Value Domain Nullable Description
assetgroup Asset Group LONG False
assettype Asset Type SHORT 0 Asset_Type_Structure_Line_Electric_Medium_Voltage_Conduit False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
diameter Diameter/Width DOUBLE True
materialcode Material SHORT Wire_Structure_Line_Duct_Material True
labeltext Labeling String TEXT (256) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
measuredlength Measured Length DOUBLE True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
designtype Design Type SHORT True
diameter_metric Diameter/Width DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
ohm Ohm DOUBLE True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Electric Medium Voltage Conduit: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Medium Voltage Conduit. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
112 Conduit MV Single terminal ['Cable Pathway'] CONTAINER DO_NOT_SPLIT ANY_VERTEX
Subtype: Connector Line
The Connector Line asset group in the StructureLine feature class is to providen network connectivity in the structure network to facilitate tracing.
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Line_Connector False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
diameter Diameter/Width DOUBLE True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
diameter_metric Diameter/Width DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
ohm Ohm DOUBLE True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Connector Line: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Connector Line. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
181 Vault Duct A feature used to provide connectivity in the structure network that is inside a Vault or Manhole. Single terminal ['Duct Trace'] NONE DO_NOT_SPLIT END_VERTEX
182 Handhole Duct A feature used to provide connectivity in the structure network that is inside a Handhole. Single terminal ['Cable Support', 'Duct Trace'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Electric High Voltage Cable Pathway
A path for routing High Voltage electrical cable
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Line_Electric_High_Voltage_Cable_Pathway False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
diameter Diameter/Width DOUBLE True
labeltext Labeling String TEXT (256) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
measuredlength Measured Length DOUBLE True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
diameter_metric Diameter/Width DOUBLE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
ohm Ohm DOUBLE True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Electric High Voltage Cable Pathway: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Electric High Voltage Cable Pathway. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
231 Overhead Pathway HV Single terminal ['Cable Pathway', 'E:Cable - Overhead', 'Overhead Spans'] CONTAINER DO_NOT_SPLIT END_VERTEX
232 Underground Pathway HV Single terminal ['Cable Pathway', 'E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
233 Submersible Pathway HV Single terminal ['Cable Pathway'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Electric Medium Voltage Cable Pathway
A path for routing Medium Voltage electrical cable
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Line_Electric_Medium_Voltage_Cable_Pathway False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
diameter Diameter/Width DOUBLE True
labeltext Labeling String TEXT (256) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
measuredlength Measured Length DOUBLE True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
diameter_metric Diameter/Width DOUBLE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
ohm Ohm DOUBLE True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Electric Medium Voltage Cable Pathway: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A path for electric cables of unknown type used in the medium voltage system Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
241 Overhead Pathway MV A path for electric cables in the overhead portion of the medium voltage system Single terminal ['Cable Pathway', 'E:Cable - Overhead', 'Overhead Spans'] CONTAINER DO_NOT_SPLIT END_VERTEX
242 Underground Pathway MV A path for electric underground cables used in the medium voltage system Single terminal ['Cable Pathway', 'E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
243 Submersible Pathway MV A path for electric submersible cables used in the medium voltage system Single terminal ['Cable Pathway'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Electric Low Voltage Cable Pathway
A path for routing Low Voltage electrical cable
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Line_Electric_Low_Voltage_Cable_Pathway False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
diameter Diameter/Width DOUBLE True
labeltext Labeling String TEXT (256) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
measuredlength Measured Length DOUBLE True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
diameter_metric Diameter/Width DOUBLE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
ohm Ohm DOUBLE True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Electric Low Voltage Cable Pathway: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown A path for electric underground cables of unknown type Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
251 Overhead Pathway LV Single terminal ['Cable Pathway', 'E:Cable - Overhead', 'Overhead Spans'] CONTAINER DO_NOT_SPLIT END_VERTEX
252 Underground Pathway LV Single terminal ['Cable Pathway', 'E:Cable - Underground'] CONTAINER DO_NOT_SPLIT END_VERTEX
253 Submersible Pathway LV Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Wire Microduct Pathway
A path for routing Communications Micro Ducts
Name Alias Type Default Value Domain Nullable Description
objectid Object ID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Line_Wire_Microduct_Pathway False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
diameter Diameter/Width DOUBLE True
materialcode Soil Type SHORT True
distance Depth DOUBLE True
labeltext Labeling String TEXT (256) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
measuredlength Measured Length DOUBLE True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
diameter_metric Diameter/Width DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
ohm Ohm DOUBLE True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Wire Microduct Pathway: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Wire micro duct Pathway. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
85 Single Microduct Casing A single Micro duct casing Single terminal ['Cable Pathway'] NONE DO_NOT_SPLIT END_VERTEX
86 Multiple Microduct Casing A casing used to encapsulate a micro duct Single terminal ['Cable Pathway'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Wire Casing
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Line_Wire_Casing False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
diameter Diameter/Width DOUBLE True
materialcode Material SHORT True
distance Depth/Height DOUBLE True
labeltext Labeling String TEXT (256) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
maximumcapacity Number of Ducts SHORT True
usedcapacity Ducts Used SHORT True
availablecapacity Ducts Open SHORT True
measuredlength Measured Length DOUBLE True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
designtype Type SHORT True
diameter_metric Diameter/Width DOUBLE True
created_user created_user TEXT (255) True
created_date created_date DATE True
last_edited_user last_edited_user TEXT (255) True
last_edited_date last_edited_date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
ohm Ohm DOUBLE True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Wire Casing: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
11 Casing Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Linear Marker
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Line_Linear_Marker False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
materialcode Material SHORT True
distance Depth/Height DOUBLE True
labeltext Labeling String TEXT (256) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
maximumcapacity Number of Ducts SHORT True
usedcapacity Ducts Used SHORT True
availablecapacity Ducts Open SHORT True
measuredlength Measured Length DOUBLE True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
designtype Type SHORT True
searchdistance Structure Search Distance DOUBLE True
created_user created_user TEXT (255) True
created_date created_date DATE True
last_edited_user last_edited_user TEXT (255) True
last_edited_date last_edited_date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
ohm Ohm DOUBLE True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Linear Marker: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
462 Buried Cable Marker Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
465 Covered Marker Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
466 Terrain Marker Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Communications Conduit
The Communications Conduit asset group in the StructureLine feature class is used to represent Conduit used to support Communications cables.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Line_Communications_Conduit False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
assetid Asset ID TEXT (64) True
diameter Diameter/Width DOUBLE True
materialcode Material SHORT Wire_Structure_Line_Duct_Material True
labeltext Labeling String TEXT (256) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
maximumcapacity Number of Ducts SHORT True
usedcapacity Ducts Used SHORT True
availablecapacity Ducts Open SHORT True
measuredlength Measured Length DOUBLE True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
designtype Type SHORT Communications_Conduit_Type True
diameter_metric Diameter/Width DOUBLE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
ohm Ohm DOUBLE True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Communications Conduit: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Communications Conduit. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
111 Conduit A feature used to represent a Conduit that contains communications cables. Single terminal ['Cable Pathway', 'Cable Support', 'Duct Trace'] CONTAINER DO_NOT_SPLIT ANY_VERTEX
Subtype: Static Wire
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_Line_Static_Wire False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Subnetwork name TEXT (2000) Unknown False
shape Shape GEOMETRY False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
diameter Diameter/Width DOUBLE True
materialcode Material SHORT Electric_StaticWire_Material True
distance Depth/Height DOUBLE True
labeltext Labeling String TEXT (256) True
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
maximumcapacity Number of Ducts SHORT True
usedcapacity Ducts Used SHORT True
availablecapacity Ducts Open SHORT True
measuredlength Measured Length DOUBLE True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
spatialsource Spatial Source SHORT Spatial_Source True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
notes General Notes TEXT (2000) True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
designtype Type SHORT True
searchdistance Structure Search Distance DOUBLE True
diameter_metric Diameter/Width DOUBLE True
created_user created_user TEXT (255) True
created_date created_date DATE True
last_edited_user last_edited_user TEXT (255) True
last_edited_date last_edited_date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
ohm Ohm DOUBLE Electric_Ohms_per_KM True
validationstatus Validation status SHORT 6 True
shape_length SHAPE_Length DOUBLE True
Subtype: Static Wire: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
860 Double Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX
861 Single Single terminal [] CONTAINER DO_NOT_SPLIT END_VERTEX

StructureEdgeObject

The Structure Edge object class represents objects that participate in the structure model, but you do not desire to represent spatialy. They should be associated with a spatial linear feature for locatability.
Class Details
DatasetType ShapeType Alias Has Attachment
TABLE Structure Edge Object True
Fields
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG 0 False
assettype Asset type SHORT 0 False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status_Combined False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
spatialsource Spatial Source SHORT Spatial_Source True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
ductid Duct Identifier SHORT True
maximumcapacity Maximum Capacity SHORT True
measuredlength Measured Length DOUBLE True
ductavailable Duct Availability Indicator SHORT Yes_No True
minimumbendradius Minimum Bend Radius DOUBLE True
availablecapacity Ducts Open SHORT True
fromport From AR Count SHORT True
toport To AR Count SHORT True
diametermetric Diameter DOUBLE Wire_Duct_Diameter_mm True
diameter Diameter DOUBLE Wire_Duct_Diameter True
minimumbendradius_metric Minimum Bend Radius DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
Subtypes
Code Name Description
0 Unknown The Unknown asset group in the Structure Edge Object class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it.
101 Wire Duct The Wire Duct asset group in the StructureEdgeObject class is used to represent line features for Ducts where a spatial feature is not desired.
111 Conduit A tube used to protect and route wiring in a building or structure
803 Ground Wire
103 Wire Aerial Support
Subtype: Unknown
The Unknown asset group in the Structure Edge Object class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 UtilityNetwork_5_UnknownAssetType False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialconfidence Spatial Confidence SHORT True
spatialsource Spatial Source SHORT True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
ductid Duct Identifier SHORT True
maximumcapacity Maximum Capacity SHORT True
measuredlength Measured Length DOUBLE True
ductavailable Duct Availability Indicator SHORT True
minimumbendradius Minimum Bend Radius DOUBLE True
availablecapacity Ducts Open SHORT True
fromport From AR Count SHORT True
toport To AR Count SHORT True
diametermetric Diameter DOUBLE True
diameter Diameter DOUBLE True
minimumbendradius_metric Minimum Bend Radius DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
Subtype: Unknown: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Structure Edge Objects of unknown type, typically only used during data migration. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Wire Duct
The Wire Duct asset group in the StructureEdgeObject class is used to represent line features for Ducts where a spatial feature is not desired.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_EdgeObject_Wire_Duct False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
spatialsource Spatial Source SHORT Spatial_Source True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
ductid Duct Identifier SHORT True
maximumcapacity Maximum Capacity SHORT True
measuredlength Measured Length DOUBLE True
ductavailable Duct Availability Indicator SHORT 1 Yes_No True
minimumbendradius Minimum Bend Radius DOUBLE True
availablecapacity Ducts Open SHORT True
fromport From AR Count SHORT True
toport To AR Count SHORT True
diametermetric Diameter DOUBLE Wire_Duct_Diameter_mm True
diameter Diameter DOUBLE Wire_Duct_Diameter True
minimumbendradius_metric Minimum Bend Radius DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
Subtype: Wire Duct: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Wire Duct. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
41 Duct A non-spatial Structure Edge Object representing a Duct found in a Duct Bank. Single terminal ['Cable Pathway', 'Cable Support', 'Duct Trace'] CONTAINER DO_NOT_SPLIT END_VERTEX
42 Microduct Casing A non-spatial Structure Edge Object representing a Micro Duct Casing found in a Duct. Single terminal ['Cable Support'] CONTAINER DO_NOT_SPLIT END_VERTEX
43 Microduct A non-spatial Structure Edge Object representing a Micro Duct found in a Micro Duct Casing. Single terminal ['Cable Pathway', 'Cable Support', 'Duct Trace'] CONTAINER DO_NOT_SPLIT END_VERTEX
44 Innerduct A non-spatial Structure Edge Object representing a Inner Duct found in a Duct. Single terminal ['Cable Support', 'Duct Trace'] CONTAINER DO_NOT_SPLIT END_VERTEX
Subtype: Conduit
A tube used to protect and route wiring in a building or structure
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_EdgeObject_Communications_Conduit False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
spatialsource Spatial Source SHORT Spatial_Source True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
ductid Duct Identifier SHORT True
maximumcapacity Maximum Capacity SHORT True
measuredlength Measured Length DOUBLE True
ductavailable Duct Availability Indicator SHORT Yes_No True
minimumbendradius Minimum Bend Radius DOUBLE True
availablecapacity Ducts Open SHORT True
fromport From AR Count SHORT True
toport To AR Count SHORT True
diametermetric Diameter DOUBLE Wire_Duct_Diameter_mm True
diameter Diameter DOUBLE Wire_Duct_Diameter True
minimumbendradius_metric Minimum Bend Radius DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
Subtype: Conduit: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
111 Conduit A feature used to represent a pipe that contains cable Single terminal ['Cable Pathway'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Ground Wire
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_EdgeObject_Ground False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
spatialsource Spatial Source SHORT Spatial_Source True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
ductid Duct Identifier SHORT True
maximumcapacity Maximum Capacity SHORT True
measuredlength Measured Length DOUBLE True
ductavailable Duct Availability Indicator SHORT True
minimumbendradius Minimum Bend Radius DOUBLE True
availablecapacity Ducts Open SHORT True
fromport From AR Count SHORT True
toport To AR Count SHORT True
diametermetric Diameter DOUBLE True
diameter Diameter DOUBLE True
minimumbendradius_metric Minimum Bend Radius DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
Subtype: Ground Wire: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
801 Bare Ground Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
802 Covered Ground Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Wire Aerial Support
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT Asset_Type_Structure_EdgeObject_Wire_Aerial_Support False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Supported Subnetwork Name TEXT (2000) Unknown False
globalid Global ID GUID False
assetid Asset ID TEXT (64) True
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status_Combined False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
spatialsource Spatial Source SHORT Spatial_Source True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
ductid Duct Identifier SHORT True
maximumcapacity Maximum Capacity SHORT True
measuredlength Measured Length DOUBLE True
ductavailable Duct Availability Indicator SHORT Yes_No True
minimumbendradius Minimum Bend Radius DOUBLE True
availablecapacity Ducts Open SHORT True
fromport From AR Count SHORT True
toport To AR Count SHORT True
diametermetric Diameter DOUBLE Wire_Duct_Diameter_mm True
diameter Diameter DOUBLE Wire_Duct_Diameter True
minimumbendradius_metric Minimum Bend Radius DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
Subtype: Wire Aerial Support: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
128 Guy Wire Single terminal [] NONE DO_NOT_SPLIT END_VERTEX

StructureJunctionObject

The Structure Junction object class represents objects that participate in the structure model, but you do not desire to represent spatialy. They should be associated with a spatial point feature for locatability.
Class Details
DatasetType ShapeType Alias Has Attachment
TABLE Structure Junction Object True
Fields
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG 0 False
assettype Asset type SHORT 0 False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Supported subnetwork name TEXT (2000) Unknown False
globalid Global ID GUID False
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status_Combined False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
diameter Diameter DOUBLE True
wallid Wall ID SHORT Structure_Wall_Position True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
spatialsource Spatial Source SHORT Spatial_Source True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
assetid Asset ID TEXT (64) True
diameter_metric Diameter DOUBLE True
materialcode Material SHORT True
depth Length/Depth DOUBLE True
height Height DOUBLE True
bracecount Number of Braces SHORT True
armcount Number of Crossarms SHORT True
mountheight Mounting Heighth DOUBLE True
depth_metric Arm Length (Metric) DOUBLE True
armheight_metric Arm Height (Metric) DOUBLE True
height_metric Height (Metric) DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
designtype Type SHORT True
ducthorizontalposition Horizontal Duct Position SHORT Structure_Duct_Position_Horizontal True
ductverticalposition Vertical Duct Position SHORT Structure_Duct_Position_Vertical True
Subtypes
Code Name Description
0 Unknown The Unknown asset group in the StructureJunction class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it.
120 Pole A vertical support structure used to support overhead cables
130 Wire Vault Knockouts The Wire Vault Knockouts asset group in the StructureJunctionObject class is used to represent a Duct Bank knockout found inside a Handhole, Manhole or Vault, where a spatial feature is not desired.
134 Wire Microduct Fitting A collection of fittings used to connect Micro Ducts
135 Wire Microduct Connection Point Points used to connect Micro Ducts that are not physical equipment
126 Wire Conduit Fittings Fittings used for connecting Conduits
132 Wire Microduct Fitting Group A group of microduct fittings.
114 Wire Crossarm A component used for supporting Cables on vertical structures like poles
151 Electric High Voltage Cable Pathway
152 Electric Medium Voltage Cable Pathway
153 Electric Low Voltage Cable Pathway
121 Aerial Support Hardware
137 Building Riser
801 Ground
803 Ground Wire
Subtype: Unknown
The Unknown asset group in the StructureJunction class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 UtilityNetwork_5_UnknownAssetType False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Supported subnetwork name TEXT (2000) Unknown False
globalid Global ID GUID False
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
diameter Diameter DOUBLE True
wallid Wall ID SHORT True
spatialconfidence Spatial Confidence SHORT True
spatialsource Spatial Source SHORT True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
assetid Asset ID TEXT (64) True
diameter_metric Diameter DOUBLE True
bracecount Number of Braces SHORT True
armcount Number of Crossarms SHORT True
mountheight Mounting Heighth DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
Subtype: Unknown: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Wire micro duct Fitting. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Pole
A vertical support structure used to support overhead cables
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_JunctionObject_Pole False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Supported subnetwork name TEXT (2000) Unknown False
globalid Global ID GUID False
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
diameter Diameter DOUBLE True
wallid Wall ID SHORT True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
spatialsource Spatial Source SHORT Spatial_Source True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
assetid Asset ID TEXT (64) True
diameter_metric Diameter DOUBLE True
bracecount Number of Braces SHORT True
armcount Number of Crossarms SHORT True
mountheight Mounting Heighth DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
Subtype: Pole: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Pole. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
101 Pole A object used to represent a Pole of any kind Single terminal ['Asset Functional', 'Cable Support', 'Wire Aerial Support Structure'] NONE DO_NOT_SPLIT END_VERTEX
102 Ornamental Pole A decorative type pole, typically used for street lights Single terminal ['Asset Functional', 'Cable Support', 'Wire Aerial Support Structure'] NONE DO_NOT_SPLIT END_VERTEX
107 Tower Leg A structure used for supporting the lower part of transmission tower Single terminal ['Asset Functional', 'Cable Support', 'Wire Aerial Support Structure'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Wire Vault Knockouts
The Wire Vault Knockouts asset group in the StructureJunctionObject class is used to represent a Duct Bank knockout found inside a Handhole, Manhole or Vault, where a spatial feature is not desired.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_JunctionObject_Wire_Vault_Knockouts False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Supported subnetwork name TEXT (2000) Unknown False
globalid Global ID GUID False
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
diameter Diameter DOUBLE True
wallid Wall ID SHORT Structure_Wall_Position True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
spatialsource Spatial Source SHORT Spatial_Source True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
assetid Asset ID TEXT (64) True
diameter_metric Diameter DOUBLE True
bracecount Number of Braces SHORT True
armcount Number of Crossarms SHORT True
mountheight Mounting Heighth DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
Subtype: Wire Vault Knockouts: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Wire Vault Knockouts Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
371 Knockout The section of a vault wall that has knockout ports. Single terminal ['Cable Support'] NONE DO_NOT_SPLIT END_VERTEX
372 Knockout Port The opening in a knockout that a duct is connected to. Single terminal ['Cable Support'] STRUCTURE DO_NOT_SPLIT END_VERTEX
373 Cross Section Position Single terminal [] STRUCTURE DO_NOT_SPLIT END_VERTEX
Subtype: Wire Microduct Fitting
A collection of fittings used to connect Micro Ducts
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_JunctionObject_Wire_Microduct_Fitting False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Supported subnetwork name TEXT (2000) Unknown False
globalid Global ID GUID False
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
diameter Diameter DOUBLE True
wallid Wall ID SHORT True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
spatialsource Spatial Source SHORT Spatial_Source True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
assetid Asset ID TEXT (64) True
diameter_metric Diameter DOUBLE True
bracecount Number of Braces SHORT True
armcount Number of Crossarms SHORT True
mountheight Mounting Heighth DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
Subtype: Wire Microduct Fitting: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Wire micro duct Fitting. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
601 Microduct Connector A connecting object for connecting micro ducts Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
602 Microduct Cap A cap for a micro duct to prevent water intrusion Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Wire Microduct Connection Point
Points used to connect Micro Ducts that are not physical equipment
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_JunctionObject_Wire_Microduct_Connection_Point False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Supported subnetwork name TEXT (2000) Unknown False
globalid Global ID GUID False
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
diameter Diameter DOUBLE True
wallid Wall ID SHORT True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
spatialsource Spatial Source SHORT Spatial_Source True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
assetid Asset ID TEXT (64) True
diameter_metric Diameter DOUBLE True
bracecount Number of Braces SHORT True
armcount Number of Crossarms SHORT True
mountheight Mounting Heighth DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
Subtype: Wire Microduct Connection Point: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Wire micro duct Connection Point. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
378 Wire Microduct Connection Point Unknown type of Wire micro duct Connection Point. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Wire Conduit Fittings
Fittings used for connecting Conduits
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_JunctionObject_Communications_Conduit_Fittings False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Supported subnetwork name TEXT (2000) Unknown False
globalid Global ID GUID False
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
diameter Diameter DOUBLE True
wallid Wall ID SHORT True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
spatialsource Spatial Source SHORT Spatial_Source True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
assetid Asset ID TEXT (64) True
diameter_metric Diameter DOUBLE True
bracecount Number of Braces SHORT True
armcount Number of Crossarms SHORT True
mountheight Mounting Heighth DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
Subtype: Wire Conduit Fittings: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Wire Conduit Fittings. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
141 Elbow A curved fitting used in conduit Single terminal ['Cable Support'] NONE DO_NOT_SPLIT END_VERTEX
142 Sweep Tee A conduit fitting with two branches using a gradual curve away from the main line Single terminal ['Cable Support'] NONE DO_NOT_SPLIT END_VERTEX
143 Y Splitter A type of three way joint used in conduits Single terminal ['Cable Support'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Wire Microduct Fitting Group
A group of microduct fittings.
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_JunctionObject_Wire_Microduct_Fitting_Group False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Supported subnetwork name TEXT (2000) Unknown False
globalid Global ID GUID False
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
diameter Diameter DOUBLE True
wallid Wall ID SHORT True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
spatialsource Spatial Source SHORT Spatial_Source True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
assetid Asset ID TEXT (64) True
diameter_metric Diameter DOUBLE True
bracecount Number of Braces SHORT True
armcount Number of Crossarms SHORT True
mountheight Mounting Heighth DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
Subtype: Wire Microduct Fitting Group: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Microduct Fitting Group Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
601 Microduct Connector Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
602 Microduct Cap Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Wire Crossarm
A component used for supporting Cables on vertical structures like poles
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT Asset_Type_Structure_JunctionObject_Crossarm False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Supported subnetwork name TEXT (2000) Unknown False
globalid Global ID GUID False
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
diameter Diameter DOUBLE Wire_Crossarm_Thickness True
wallid Wall ID SHORT True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
spatialsource Spatial Source SHORT Spatial_Source True
ownedby Owned By SHORT Asset_Owner True
maintby Maintained By SHORT Asset_Manager True
assetid Asset ID TEXT (64) True
diameter_metric Diameter DOUBLE Wire_Crossarm_Thickness_Metric True
bracecount Number of Braces SHORT Wire_Crossarm_Brace_Count True
armcount Number of Crossarms SHORT Wire_Crossarm_Count True
mountheight Mounting Heighth DOUBLE Wire_Crossarm_MountHeight True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT Construction_Status False
sectionid Section ID TEXT (2000) True
Subtype: Wire Crossarm: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Unknown type of Wire Crossarm. Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
1 Dead End A horizontal mounted structure on a pole used to support cables that is braced to allow tension transfer from the cable to the structure Single terminal ['Cable Support', 'E:Crossarm'] STRUCTURE DO_NOT_SPLIT END_VERTEX
2 Tangent A horizontal mounted structure on a pole used to support cables Single terminal ['Cable Support', 'E:Crossarm'] STRUCTURE DO_NOT_SPLIT END_VERTEX
Subtype: Electric High Voltage Cable Pathway
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT Asset_Type_Structure_JunctionObject_Electric_High_Voltage_Cable_Pathway False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Supported subnetwork name TEXT (2000) Unknown False
globalid Global ID GUID False
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
diameter Diameter DOUBLE True
wallid Wall ID SHORT True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
spatialsource Spatial Source SHORT Spatial_Source True
ownedby Owned By SHORT Asset_Owner True
maintby Maintained By SHORT Asset_Manager True
assetid Asset ID TEXT (64) True
diameter_metric Diameter DOUBLE True
bracecount Number of Braces SHORT True
armcount Number of Crossarms SHORT True
mountheight Mounting Heighth DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT Construction_Status False
sectionid Section ID TEXT (2000) True
Subtype: Electric High Voltage Cable Pathway: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
231 Overhead Pathway HV Single terminal ['Cable Pathway'] NONE DO_NOT_SPLIT END_VERTEX
232 Underground Pathway HV Single terminal ['Cable Pathway'] NONE DO_NOT_SPLIT END_VERTEX
233 Submersible Pathway HV Single terminal ['Cable Pathway'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Electric Medium Voltage Cable Pathway
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT Asset_Type_Structure_JunctionObject_Electric_Medium_Voltage_Cable_Pathway False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Supported subnetwork name TEXT (2000) Unknown False
globalid Global ID GUID False
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
diameter Diameter DOUBLE True
wallid Wall ID SHORT True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
spatialsource Spatial Source SHORT Spatial_Source True
ownedby Owned By SHORT Asset_Owner True
maintby Maintained By SHORT Asset_Manager True
assetid Asset ID TEXT (64) True
diameter_metric Diameter DOUBLE True
bracecount Number of Braces SHORT True
armcount Number of Crossarms SHORT True
mountheight Mounting Heighth DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT Construction_Status False
sectionid Section ID TEXT (2000) True
Subtype: Electric Medium Voltage Cable Pathway: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
241 Overhead Pathway MV Single terminal ['Cable Pathway'] NONE DO_NOT_SPLIT END_VERTEX
242 Underground Pathway MV Single terminal ['Cable Pathway'] NONE DO_NOT_SPLIT END_VERTEX
243 Submersible Pathway MV Single terminal ['Cable Pathway'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Electric Low Voltage Cable Pathway
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT Asset_Type_Structure_JunctionObject_Electric_Low_Voltage_Cable_Pathway False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Supported subnetwork name TEXT (2000) Unknown False
globalid Global ID GUID False
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
diameter Diameter DOUBLE True
wallid Wall ID SHORT True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
spatialsource Spatial Source SHORT Spatial_Source True
ownedby Owned By SHORT Asset_Owner True
maintby Maintained By SHORT Asset_Manager True
assetid Asset ID TEXT (64) True
diameter_metric Diameter DOUBLE True
bracecount Number of Braces SHORT True
armcount Number of Crossarms SHORT True
mountheight Mounting Heighth DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT Construction_Status False
sectionid Section ID TEXT (2000) True
Subtype: Electric Low Voltage Cable Pathway: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
251 Overhead Pathway LV Single terminal ['Cable Pathway'] NONE DO_NOT_SPLIT END_VERTEX
252 Underground Pathway LV Single terminal ['Cable Pathway'] NONE DO_NOT_SPLIT END_VERTEX
253 Submersible Pathway LV Single terminal ['Cable Pathway'] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Aerial Support Hardware
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_JunctionObject_Aerial_Support_Hardware False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Supported subnetwork name TEXT (2000) Unknown False
globalid Global ID GUID False
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
diameter Diameter DOUBLE True
wallid Wall ID SHORT True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
spatialsource Spatial Source SHORT Spatial_Source True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
assetid Asset ID TEXT (64) True
diameter_metric Diameter DOUBLE True
bracecount Number of Braces SHORT True
armcount Number of Crossarms SHORT True
mountheight Mounting Heighth DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
Subtype: Aerial Support Hardware: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
103 Tower Base Single terminal ['Asset Functional', 'Wire Aerial Support Structure'] NONE DO_NOT_SPLIT END_VERTEX
104 Tower Beam Single terminal ['Asset Functional', 'Wire Aerial Support Structure'] NONE DO_NOT_SPLIT END_VERTEX
105 Tower Diagonal Single terminal ['Asset Functional', 'Wire Aerial Support Structure'] NONE DO_NOT_SPLIT END_VERTEX
106 Tower Ground Wire Peak Single terminal ['Asset Functional', 'Wire Aerial Support Structure'] NONE DO_NOT_SPLIT END_VERTEX
109 Cable Guards Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
110 Brace Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
111 Down Guy Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
112 Guy Strain Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
113 Messenger Hanger Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
114 Platform Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
115 Push Pole Brace Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
116 Pole Top Cap Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
117 Wildlife Protector Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
118 Aerial Lighting Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Building Riser
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_JunctionObject_Wire_Building_Riser False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Supported subnetwork name TEXT (2000) Unknown False
globalid Global ID GUID False
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
diameter Diameter DOUBLE True
wallid Wall ID SHORT True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
spatialsource Spatial Source SHORT Spatial_Source True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
assetid Asset ID TEXT (64) True
diameter_metric Diameter DOUBLE True
bracecount Number of Braces SHORT True
armcount Number of Crossarms SHORT True
mountheight Mounting Heighth DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
Subtype: Building Riser: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
396 Building Riser Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Ground
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_JunctionObject_Ground False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Supported subnetwork name TEXT (2000) Unknown False
globalid Global ID GUID False
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
diameter Diameter DOUBLE True
wallid Wall ID SHORT True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
spatialsource Spatial Source SHORT Spatial_Source True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
assetid Asset ID TEXT (64) True
diameter_metric Diameter DOUBLE True
bracecount Number of Braces SHORT True
armcount Number of Crossarms SHORT True
mountheight Mounting Heighth DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
Subtype: Ground: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
811 Joint Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
812 Plate Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
813 Rod Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
814 Lightning Pole Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
815 Lightning Rod Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
Subtype: Ground Wire
Name Alias Type Default Value Domain Nullable Description
objectid OBJECTID OID False
assetgroup Asset group LONG False
assettype Asset type SHORT 0 Asset_Type_Structure_JunctionObject_GroundWire False
associationstatus Association status SHORT 0 UtilityNetwork_5_AssociationStatus False
subnetworkname Supported subnetwork name TEXT (2000) Unknown False
globalid Global ID GUID False
lifecyclestatus Lifecycle Status SHORT 2 Lifecycle_Status False
installdate Install Date DATE True
retireddate Retired Date DATE True
inservicedate In-Service Date DATE True
diameter Diameter DOUBLE True
wallid Wall ID SHORT True
spatialconfidence Spatial Confidence SHORT Spatial_Confidence True
spatialsource Spatial Source SHORT Spatial_Source True
ownedby Owned By SHORT 1 Asset_Owner True
maintby Maintained By SHORT 1 Asset_Manager True
assetid Asset ID TEXT (64) True
diameter_metric Diameter DOUBLE True
bracecount Number of Braces SHORT True
armcount Number of Crossarms SHORT True
mountheight Mounting Heighth DOUBLE True
created_user Created User TEXT (255) True
created_date Created Date DATE True
last_edited_user Last Edited User TEXT (255) True
last_edited_date Last Edited Date DATE True
constructionstatus Construction Status SHORT 6 Construction_Status False
sectionid Section ID TEXT (2000) True
Subtype: Ground Wire: Asset Types
Code Name Alternate Name Description terminalConfigurationName categories associationRoleType splitContent connectivityPolicy
0 Unknown Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
801 Bare Ground Single terminal [] NONE DO_NOT_SPLIT END_VERTEX
802 Covered Ground Single terminal [] NONE DO_NOT_SPLIT END_VERTEX

Attribute Domains

AnnotationStatus

Valid annotation state values.
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Placed
1 Unplaced

Asset_Manager

The manager of the asset
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
1 Our Agency
2 Private
100 Other

Asset_Owner

The owner of the asset
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
1 Our Agency
2 Private
100 Other

Asset_Type_Electric_Assembly_Electric_Grounding_Equipment

Electric Grounding Equipment Assembly
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
30 Grounding Equipment

Asset_Type_Electric_Assembly_High_Voltage_AC_Power_Factor_Correcting_Bank

High Voltage AC Power Factor Correcting Bank
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Series
2 Shunt

Asset_Type_Electric_Assembly_High_Voltage_Bay

Bay container
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
91 Capacitor
92 Regulator
93 Switch
94 Transformer
95 Metering

Asset_Type_Electric_Assembly_High_Voltage_Controller

High Voltage Controller Assembly
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
24 Station

Asset_Type_Electric_Assembly_High_Voltage_DC_Power_Factor_Correcting_Bank

High Voltage DC Power Factor Correcting Bank
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Series
2 Shunt

Asset_Type_Electric_Assembly_High_Voltage_Service_Bank

High Voltage Service Bank
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
41 Industrial Customer
42 Utility Customer

Asset_Type_Electric_Assembly_High_Voltage_Switch_Bank

High Voltage Switch Bank
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
61 AC Circuit Breaker
62 AC Line Disconnect
63 AC Station Disconnect
64 DC Circuit Breaker
65 DC Line Disconnect
66 DC Station Load Break

Asset_Type_Electric_Assembly_High_Voltage_Transformer_Bank

High Voltage Transformer Bank
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
81 AC Power
82 DC Power

Asset_Type_Electric_Assembly_Low_Voltage_Arrester_Bank

Low Voltage Arrester Bank
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
101 Indoor Arrester Bank
102 Line Arrester Bank
103 Station Arrester Bank

Asset_Type_Electric_Assembly_Low_Voltage_Bay

Bay container
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
91 Capacitor
92 Regulator
93 Switch
94 Transformer
95 Metering

Asset_Type_Electric_Assembly_Low_Voltage_Connector_Bank

The Asset Types for the Low Voltage Connector Bank
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
360 Flying Tap

Asset_Type_Electric_Assembly_Low_Voltage_Controller

Low Voltage Controller Assembly
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
24 Station

Asset_Type_Electric_Assembly_Low_Voltage_Fuse_Bank

Low Voltage Fuse Bank
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
121 AC Fuse
122 DC Fuse

Asset_Type_Electric_Assembly_Low_Voltage_Service_Bank

Low Voltage Service Bank
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
41 Industrial Customer
42 Utility Customer
161 Commercial
284 Residential

Asset_Type_Electric_Assembly_Low_Voltage_Switch_Bank

Low Voltage Switch Bank
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
181 Overhead AC Disconnect OH AC Disconnect
182 Overhead AC Load Break OH AC Load Break
183 Overhead DC Disconnect OH DC Disconnect
184 Overhead DC Load Break OH DC Load Break
185 Underground AC Disconnect UG AC Disconnect
186 Underground AC Load Break UG AC Load Break
187 Underground DC Disconnect UG DC Disconnect
188 Underground DC Load Break UG DC Load Break
189 Indoor AC Disconnect
190 Indoor AC Load Break
191 Indoor DC Disconnect
192 Indoor DC Load Break

Asset_Type_Electric_Assembly_Low_Voltage_Transformer_Bank

Low Voltage Transformer Bank
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
8 Transformer Bank

Asset_Type_Electric_Assembly_Medium_Voltage_Arrester_Bank

Medium Voltage Arrester Bank
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
201 Indoor Arrester Bank
202 Line Arrester Bank
203 Station Arrester Bank

Asset_Type_Electric_Assembly_Medium_Voltage_Bay

Bay container
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
91 Capacitor
92 Regulator
93 Switch
94 Transformer
95 Metering

Asset_Type_Electric_Assembly_Medium_Voltage_Connector_Bank

The Asset Types for the Medium Voltage Connector Bank
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
360 Flying Tap

Asset_Type_Electric_Assembly_Medium_Voltage_Controller

Medium Voltage Controller Asembly
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
24 Station

Asset_Type_Electric_Assembly_Medium_Voltage_Fuse_Bank

Medium Voltage Fuse Bank
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
221 Overhead Disconnect Fuse Holder OH Disconnect
222 Overhead Load Break Fuse Holder OH Load Break
223 Pad Mounted Disconnect UG Disconnect
224 Pad Mounted Load Break UG Load Break

Asset_Type_Electric_Assembly_Medium_Voltage_Line_Monitor_and_Relay_Bank

Line monitor and Relay Bank
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
290 Fault Indicator Bank
291 Instrument Transformer Bank
292 Programmable Logic Unit Bank
293 Remote Transmission Unit Bank
294 SCADA Load Monitor Bank
295 Relay Bank

Asset_Type_Electric_Assembly_Medium_Voltage_Power_Factor_Correcting_Bank

Medium Voltage Power Factor Correcting Bank
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
241 Mobile Capacitor
242 Overhead Capacitor OH Capacitor
243 Overhead Harmonic Filter OH Harmonic Filter
244 Pad Mounted Capacitor UG Capacitor
245 Pad Mounted Harmonic Filter UG Harmonic Filter

Asset_Type_Electric_Assembly_Medium_Voltage_Recloser_Bank

Medium Voltage Recloser Bank
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
303 Overhead Recloser
307 Pad Mounted Recloser

Asset_Type_Electric_Assembly_Medium_Voltage_Regulator_Bank

Medium Voltage Regulator Bank
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
261 Overhead Single Phase Regulator OH 1P Regulator
262 Overhead Single Phase Regulator Delta OH 1P Regulator Delta
264 Overhead Single Phase Regulator Wye OH 1P Regulator Wye
265 Overhead Three Phase Regulator OH 1P Regulator
266 Overhead Three Phase Regulator Delta OH 3P Regulator Delta
267 Overhead Three Phase Regulator Open Delta OH 3P Regulator Open Delta
268 Overhead Three Phase Regulator Wye OH 3P Regulator Wye
269 Pad Mounted Single Phase Regulator UG 1P Regulator
270 Pad Mounted Three Phase Regulator UG 3P Regulator
271 Pad Mounted Three Phase Regulator Delta UG 3P Regulator Delta
272 Pad Mounted Three Phase Regulator Wye UG 3P Regulator Wye

Asset_Type_Electric_Assembly_Medium_Voltage_Sectionalizer_Bank

Medium Voltage Sectionalizer Bank
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
304 Overhead Sectionalizer
308 Pad Mounted Sectionalizer

Asset_Type_Electric_Assembly_Medium_Voltage_Service_Bank

Medium Voltage Service Bank
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
281 PM Commercial Customer
282 PM Industrial Customer
283 Primary Meter
284 Residential

Asset_Type_Electric_Assembly_Medium_Voltage_Switch_Bank

Medium Voltage Switch Bank
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
301 Overhead Disconnect Switch OH Disconnect
302 Overhead Load Break Switch OH Load Break
305 Station Disconnect Switch
306 Station Load Break Switch
309 Pad Mounted Switch UG Switch
310 Overhead Jumper
311 Underground Switch

Asset_Type_Electric_Assembly_Medium_Voltage_Transformer_Bank

Medium Voltage Transformer Bank
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
321 Overhead Single Phase OH 1 Phase
322 Overhead Three Phase OH 3 Phase
323 Overhead Three Phase Delta OH 3 Phase Delta
324 Overhead Open Delta OH OD | OH Open Delta
325 Overhead Open Wye OH OW | OH Open Wye
326 Overhead Three Phase Wye OH 3 Phase Wye
327 Overhead Single Phase Step
328 Overhead Three Phase Step
329 Overhead Three Phase Step Delta
330 Overhead Three Phase Step Wye
331 Overhead Three Phase Step Open Delta
332 Overhead Three Phase Step Open Wye
333 Pad Mounted Single Phase UG 1 Phase
334 Pad Mounted Three Phase UG 3 Phase
335 Pad Mounted Three Phase Delta UG 3 Phase Delta
336 Pad Mounted Three Phase Wye UG 3 Phase Wye
337 Pad Mounted Single Phase Step
338 Pad Mounted Three Phase Step
339 Pad Mounted Three Phase Step Delta
340 Pad Mounted Three Phase Step Wye
341 Pad Mounted Open Delta UG 2 Phase Open Delta
342 Pad Mounted Open Wye UG 2 Phase Open Wye
343 Submersible Single Phase
344 Submersible Three Phase
345 Network

Asset_Type_Electric_Device_Ground

Ground
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Ground
31 Bound
32 Rod
33 Voltage Grid
34 Stray Voltage Isolator
35 Grounding Switch
36 Cross Bond
37 Ground Plate
38 Ground Joint

Asset_Type_Electric_Device_High_Voltage_Control_Unit

High Voltage Controller
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Control Unit
41 Capacitor HV
42 Switch and Breaker HV
43 Voltage Regulator HV

Asset_Type_Electric_Device_High_Voltage_Fuse

High Voltage Fuse
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Fuse
581 AC Station Disconnect Fuse HV
582 AC Station Load Break Fuse HV
583 AC Load Break Disconnect Fuse HV
584 AC Load Break Fuse HV - Controller
585 AC Disconnect Fuse HV - Controller
586 AC Load Break Disconnect Fuse HV - Controller

Asset_Type_Electric_Device_High_Voltage_Generation

High Voltage Generation
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Generation
61 Battery HV
62 Biomass HV
63 Coal HV
64 Gas Turbine HV
65 Geothermal HV
66 Hydro HV
67 Nuclear HV
68 Photovoltaic Solar HV
69 Thermal Solar HV
70 Wind HV
71 AC Wave HV
72 Generator HV
73 Interconnect HV

Asset_Type_Electric_Device_High_Voltage_Line_Hardware

Asset Types for equipment that connects electric lines to towers and poles
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Line Hardware
834 Damper
836 Spacer
837 Aerial Marker
838 Buried Cable Marker
839 Submerged Cable Marker
840 Overhead Water Crossing Marker
841 Airflow Spoiler
842 Bird Diverter
843 Line Weight

Asset_Type_Electric_Device_High_Voltage_Line_Monitor_and_Relay

High Voltage Line Monitor and Relay
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Line Monitor and Relay
80 Fault Indicator HV
81 Instrument Transformer HV
82 Load Monitor HV
83 Relay HV

Asset_Type_Electric_Device_High_Voltage_Power_Conversion

High Voltage Power Conversion
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Power Conversion
101 Inverter HV
102 Rectifier HV
103 Bidirectional HV

Asset_Type_Electric_Device_High_Voltage_Power_Factor_Correcting

High Voltage Power Factor Correcting
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Power Factor Correcting
121 AC Capacitor HV
122 AC Wave Trap HV
123 AC Reactor HV
124 DC Capacitor HV
125 DC Reactor HV
126 Synchronous Condenser HV

Asset_Type_Electric_Device_High_Voltage_Regulator

High Voltage Regulator
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Regulator
171 AC Single Phase HV
172 AC Three Phase HV
173 DC Regulator HV
174 Frequency Converter HV

Asset_Type_Electric_Device_High_Voltage_Service

High Voltage Service
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Service
161 AC Metering HV
162 DC Metering HV
163 High Voltage Premise HV

Asset_Type_Electric_Device_High_Voltage_Switch

High Voltage Switch
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Switch
181 AC Circuit Breaker HV
182 AC Disconnect HV
183 AC Switchgear HV
184 DC Circuit Breaker HV
185 DC Disconnect HV
186 DC Switchgear HV
187 AC Bus Tie Breaker HV
188 DC Bus Tie Breaker HV
189 AC Disconnect - Grounded HV
190 AC Recloser HV
191 AC Circuit Breaker HV - Controller
192 AC Station Load Break Disconnect HV
193 AC Station Load Break Disconnect HV - Controller
194 DC Circuit Breaker HV - Controller
195 AC Disconnect HV - Controller
196 AC Grounding HV
197 AC Thyristor HV
198 DC Thyristor HV
199 AC Transfer Switch HV

Asset_Type_Electric_Device_High_Voltage_Transformer

High Voltage Transformer
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Transformer
201 AC Single Phase - HV->MV
202 AC Three Phase - HV->MV
203 DC Power - HV->HV
204 Grounding Transformer - HV->MV
205 Station - HV->MV
206 Station Three Winding - HV->HV-HV
207 Station Three Winding - HV->HV-MV
208 Phase Control - HV->HV
209 Station Three Winding - HV->HV-LV
210 Station Step Up - MV->HV
211 Station Step - HV->HV
212 Station Three Winding - HV->MV-MV
213 Station Three Winding - HV->MV-LV

Asset_Type_Electric_Device_High_Voltage_Transformer_Winding

Asset Types for Transformer Windings
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Transformer Winding
871 AC Transformer Winding HV
872 DC Transformer Winding HV

Asset_Type_Electric_Device_Low_Voltage_Circuit_Breaker

Asset Types for Low Voltage Circuit Breakers
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Circuit Breaker
1 AC Overhead
2 AC Underground
3 AC Station
4 AC Overhead Bank
5 AC Underground Bank
6 AC Station Bank
11 DC Overhead
12 DC Underground
13 DC Station
14 DC Overhead Bank
15 DC Underground Bank
16 DC Station Bank
471 AC Circuit Breaker LV
472 DC Circuit Breaker LV
473 AC Circuit Breaker LV - Controller
474 DC Circuit Breaker LV - Controller

Asset_Type_Electric_Device_Low_Voltage_Control_Unit

Low Voltage Controller
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Control Unit
241 Control Unit LV Relay

Asset_Type_Electric_Device_Low_Voltage_Fuse

Low Voltage Fuse
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Fuse
1 AC Overhead
2 AC Underground
3 AC Station
4 AC Overhead Bank
5 AC Underground Bank
6 AC Station Bank
11 DC Overhead
12 DC Underground
13 DC Station
14 DC Overhead Bank
15 DC Underground Bank
16 DC Station Bank
259 Service Fuse Load Break LV
260 Service Fuse Disconnect LV
261 AC Overhead Fuse LV
262 AC Underground Fuse LV
263 DC Overhead Fuse LV
264 DC Underground Fuse LV
265 AC Overhead Load Break Fuse LV
266 AC Overhead Fuse LV - Controller
267 AC Underground Load Break Fuse LV
268 AC Underground Fuse LV - Controller
269 DC Overhead Fuse LV - Controller
270 DC Underground Fuse LV - Controller
271 AC Overhead Cutout Load Break Disconnect Fuse LV
272 AC Overhead Cutout Load Break Fuse LV - Controller
273 AC Overhead Cutout Disconnect Fuse LV - Controller
274 AC Overhead Cutout Load Break Fuse LV
275 Station Disconnect Fuse LV
276 Station Load Break Fuse LV
277 Station Load Break Disconnect Fuse LV
278 Station Disconnect Fuse LV - Controller
279 Station Load Break Fuse LV - Controller
280 Station Load Break Disconnect Fuse LV - Controller

Asset_Type_Electric_Device_Low_Voltage_Generation

Low Voltage Generation
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Generation
281 Battery LV
283 Generator LV
284 Residential Photovoltaic Solar LV
285 Wind Turbine LV
286 AC Wave LV
428 Car Charger LV

Asset_Type_Electric_Device_Low_Voltage_Lighting

Low Voltage Lighting
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Lighting
301 Floodlight LV
302 Streetlight LV

Asset_Type_Electric_Device_Low_Voltage_Line_Monitor_and_Relay

Low Voltage Line Monitor and Relay
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Line Monitor and Relay
321 Fault Indicator LV
322 Load Monitor LV
323 Relay LV
324 Instrument Transformer LV

Asset_Type_Electric_Device_Low_Voltage_Motor

Low Voltage Motor
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Motor
341 Single Phase Motor LV
342 Three Phase Motor LV
343 DC Motor LV

Asset_Type_Electric_Device_Low_Voltage_Network_Protection

Low Voltage Network Protection
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Network Protector
361 Network Protector LV

Asset_Type_Electric_Device_Low_Voltage_Power_Conversion

Low Voltage Power Conversion
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Power Conversion
381 Single Phase Inverter LV
382 Single Phase Rectifier LV
383 Three Phase Inverter LV
384 Three Phase Rectifier LV
386 Single Phase Bidirectional LV
387 Three Phase Bidirectional LV
390 Wave Trap LV

Asset_Type_Electric_Device_Low_Voltage_Power_Factor_Correcting

Low Voltage Power Factor Correcting
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Power Factor Correcting
1 AC Overhead
2 AC Underground
3 AC Station
4 AC Overhead Bank
5 AC Underground Bank
6 AC Station Bank
11 DC Overhead
12 DC Underground
13 DC Station
401 Mobile Harmonic Filter LV
402 Mobile Reactor LV
403 Overhead Capacitor LV
404 Overhead Harmonic Filter LV
405 Overhead Reactor LV
406 Pad Mounted Capacitor LV
407 Pad Mounted Harmonic Filter LV
408 Pad Mounted Reactor LV
409 Station Capacitor LV
410 Station Harmonic Filter LV
411 Station Reactor LV

Asset_Type_Electric_Device_Low_Voltage_Regulator

Asset Types for Low Voltage Regulating Equipment
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Regulator
141 AC Single Phase LV
142 AC Three Phase LV
143 DC Regulator LV
144 Network Load Balancer LV
145 Frequency Converter LV

Asset_Type_Electric_Device_Low_Voltage_Service

Low Voltage Service
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Service
421 Single Phase Commercial LV
422 Single Phase Residential LV
423 Three Phase Commercial LV
424 Three Phase Residential LV
425 Unmetered Load LV
426 DC Commercial LV
427 Low Voltage Premise LV
428 Car Charger LV

Asset_Type_Electric_Device_Low_Voltage_Switch

Low Voltage Switch
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Switch
1 AC Overhead
2 AC Underground
3 AC Station
4 AC Overhead Bank
5 AC Underground Bank
6 AC Station Bank
11 DC Overhead
12 DC Underground
13 DC Station
14 DC Overhead Bank
15 DC Underground Bank
16 DC Station Bank
431 AC Station Disconnect LV
432 AC Station Load Break LV
433 AC Station Load Break Disconnect LV
434 AC Station Disconnect LV - Controller
435 AC Station Load Break LV - Controller
436 AC Station Load Break Disconnect LV - Controller
441 Overhead AC Load Break LV
442 Overhead AC Disconnect LV
443 Overhead DC Load Break LV
444 Overhead DC Disconnect LV
445 Underground AC Load Break LV
446 Underground AC Disconnect LV
447 Underground DC Load Break LV
448 Underground DC Disconnect LV
449 Indoor AC Load Break LV
450 Indoor AC Disconnect LV
451 Indoor DC Load Break LV
452 Indoor DC Disconnect LV
453 Source Selectable Switch LV
454 Overhead Jumper LV
456 DC Station LV
457 AC Station Bypass LV
458 AC Recloser LV

Asset_Type_Electric_Device_Low_Voltage_Transformer

Low Voltage Transformer
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Transformer
461 Single Phase - LV->LV
462 Three Phase - LV->LV
463 Three Winding - LV->LV-LV

Asset_Type_Electric_Device_Low_Voltage_Transformer_Winding

Asset Types for Transformer Windings
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Transformer Winding
874 AC Transformer Winding LV
875 DC Transformer Winding LV

Asset_Type_Electric_Device_Low_Voltage_Wire_Connector

Low Voltage Connectors
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Wire Connector
861 Ring Terminal LV

Asset_Type_Electric_Device_Medium_Voltage_Circuit_Breaker

Medium Voltage Circuit Breaker
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Circuit Breaker
501 Isolator Switch MV
502 Single Phase Circuit Breaker MV
503 Three Phase Circuit Breaker MV
512 Single Phase Circuit Breaker MV - Controller
513 Three Phase Circuit Breaker MV - Controller
515 Network Protector MV

Asset_Type_Electric_Device_Medium_Voltage_Control_Unit

Medium Voltage Controller
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Control Unit
521 Capacitor MV
522 Circuit Breaker MV
523 Recloser MV
524 Transfer Switch Controller MV
525 Regulator MV

Asset_Type_Electric_Device_Medium_Voltage_Elbow

Medium Voltage Elbow
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Elbow
2 AC Underground
5 AC Underground Bank
541 Load Break Feedthru MV
542 Load Break Junction MV
543 Single Phase Dead Break MV
544 Single Phase Load Break MV
545 Three Phase Dead Break MV
546 Three Phase Load Break MV

Asset_Type_Electric_Device_Medium_Voltage_Fuse

Medium Voltage Fuse
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Fuse
1 AC Overhead
2 AC Underground
3 AC Station
4 AC Overhead Bank
5 AC Underground Bank
6 AC Station Bank
561 Bayonet Fuse MV
562 Fault Limiter Fuse MV
563 Indoor Fuse MV
564 Overhead Cutout Disconnect Fuse MV
565 Overhead Cutout Load Break Fuse MV
566 Overhead Cutout Sectionalizer Fuse MV
567 Overhead Cutout Solid Blade Fuse MV
568 Cabinet Fuse MV
569 Underground Fuse MV
570 Underground Disconnect Fuse MV
571 Underground Load Break Fuse MV
572 Overhead Cutout Load Break Disconnect Fuse MV
573 Overhead Cutout Load Break Fuse MV - Controller
574 Overhead Cutout Disconnect Fuse MV - Controller
575 Overhead Cutout Load Break Disconnect Fuse MV - Controller

Asset_Type_Electric_Device_Medium_Voltage_Generation

Medium Voltage Generation
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Generation
110 AC Wave MV
111 Battery MV
112 Biomass MV
113 Generator MV
114 Gas Turbine MV
115 Geothermal MV
116 Hydro MV
117 Wind MV
118 Photovoltaic Solar MV
119 Thermal Solar MV
120 Interconnect MV

Asset_Type_Electric_Device_Medium_Voltage_Line_Hardware

Asset Types for equipment that connects electric lines to towers and poles
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
834 Damper
836 Spacer
837 Aerial Marker
838 Buried Cable Marker
839 Submerged Cable Marker
840 Overhead Water Crossing Marker
841 Airflow Spoiler
842 Bird Diverter
843 Line Weight

Asset_Type_Electric_Device_Medium_Voltage_Line_Monitor_and_Relay

Medium Voltage Line Monitor and Relay
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Line Monitor and Relay
601 Fault Indicator MV
602 Instrument Transformer MV
603 Programmable Logic Unit MV
604 Remote Terminal Unit MV
605 SCADA Load Monitor MV
606 SCADA Weather Station MV
607 Relay MV

Asset_Type_Electric_Device_Medium_Voltage_Motor_and_Pump

Medium Voltage Motor and Pump
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Motor and Pump
621 Single Phase Motor MV
622 Single Phase Pump MV
623 Three Phase Motor MV
624 Three Phase Pump MV

Asset_Type_Electric_Device_Medium_Voltage_Power_Conversion

Medium Voltage Power Conversion
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Power Conversion
641 Single Phase Inverter MV
642 Single Phase Rectifier MV
643 Three Phase Inverter MV
644 Three Phase Rectifier MV
645 Single Phase Bidirectional MV
646 Three Phase Bidirectional MV
647 Wave Trap MV

Asset_Type_Electric_Device_Medium_Voltage_Power_Factor_Correcting

Medium Voltage Power Factor Correcting
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Power Factor Correcting
1 AC Overhead
2 AC Underground
3 AC Station
4 AC Overhead Bank
5 AC Underground Bank
6 AC Station Bank
661 Mobile Capacitor MV
664 Overhead Single Phase Capacitor MV
665 Overhead Three Phase Capacitor MV
666 Overhead Harmonic Filter MV
667 Overhead Reactor MV
668 Pad Mounted Single Phase Capacitor MV
669 Pad Mounted Three Phase Capacitor MV
671 Mobile Harmonic Filter MV
672 Mobile Reactor MV
673 Pad Mounted Harmonic Filter MV
674 Pad Mounted Reactor MV
675 Station Capacitor MV
676 Station Harmonic Filter MV
677 Station Reactor MV
678 Synchronous Condenser MV

Asset_Type_Electric_Device_Medium_Voltage_Recloser

Medium Voltage Recloser Asset Types
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Recloser
1 AC Overhead
2 AC Underground
4 AC Overhead Bank
5 AC Underground Bank
730 Overhead Single Phase Recloser MV
734 Overhead Three Phase Recloser MV - Controller
738 Pad Mounted Three Phase Recloser MV - Controller
744 Overhead Three Phase Recloser MV
747 Pad Mounted Single Phase Recloser MV
748 Pad Mounted Three Phase Recloser MV

Asset_Type_Electric_Device_Medium_Voltage_Regulator

Medium Voltage Regulator
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Regulator
1 AC Overhead
2 AC Underground
3 AC Station
4 AC Overhead Bank
5 AC Underground Bank
6 AC Station Bank
681 Overhead Single Phase VR MV
683 Overhead Three Phase VR MV
685 Pad Mounted Single Phase VR MV
687 Pad Mounted Three Phase VR MV
688 Frequency Converter MV

Asset_Type_Electric_Device_Medium_Voltage_Sectionalizer

Medium Voltage Secitionalizer
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Sectionalizer
1 AC Overhead
2 AC Underground
4 AC Overhead Bank
5 AC Underground Bank
731 Overhead Single Phase Sectionalizer MV
745 Overhead Three Phase Sectionalizer MV
749 Pad Mounted Single Phase Sectionalizer MV
750 Pad Mounted Three Phase Sectionalizer MV

Asset_Type_Electric_Device_Medium_Voltage_Service

Medium Voltage Service
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Service
701 Primary Meter - Industrial Customer MV
702 Primary Meter - Utility Customer MV
703 Primary Meter Circuit Source MV
704 Medium Voltage Premise MV

Asset_Type_Electric_Device_Medium_Voltage_Switch

Medium Voltage Switch
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Switch
1 AC Overhead
2 AC Underground
3 AC Station
4 AC Overhead Bank
5 AC Underground Bank
6 AC Station Bank
721 Cabinet Bypass MV
722 Cabinet Switch MV
723 Cabinet Switch - Grounded MV
724 Overhead Bypass MV
725 Overhead Grounding Switch MV
726 Overhead Jumper MV
727 Station Grounding MV
728 Overhead Single Phase Disconnect MV
729 Overhead Single Phase Load Break MV
732 Overhead Three Phase Disconnect MV
733 Overhead Three Phase Load Break MV
746 Pad Mounted Fault Interrupter MV
751 Station Single Phase Disconnect MV
752 Station Disconnect MV
753 T Blade MV
754 V Blade MV
755 Underground Single Phase Disconnect MV
758 Underground Single Phase Load Break MV
759 Underground Three Phase Disconnect MV
760 Underground Three Phase Load Break MV
761 Underground Transfer Switch MV
765 Bus Tie Breaker MV
766 Station Load Break MV
768 Station Disconnect - Grounded MV
769 Station Load Break Disconnect MV
770 Station Disconnect MV - Controller
771 Station Load Break MV - Controller
772 Station Load Break Disconnect MV - Controller

Asset_Type_Electric_Device_Medium_Voltage_Transformer

Medium Voltage Transformer
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Transformer
781 Grounding Transformer - MV->MV
782 Mobile Single Phase - MV->LV
783 Mobile Three Phase - MV->LV
784 Network - MV->LV
785 Overhead Single Phase - MV->LV
786 Station - MV->LV
787 Station Three Winding - MV->LV-LV
788 Overhead Three Phase - MV->LV
789 Pad Mounted Single Phase - MV->LV
790 Station Three Winding - MV->MV-LV
792 Pad Mounted Three Phase - MV->LV
793 Submersible Single Phase - MV->LV
794 Submersible Three Phase - MV->LV
795 Overhead Open Delta - MV->LV
796 Overhead Open Wye - MV->LV
797 Pad Mounted Open Delta - MV->LV
798 Pad Mounted Open Wye - MV->LV
801 Overhead Single Phase Step - MV<->MV
802 Overhead Three Phase Step - MV<->MV
803 Overhead Single Phase Step - MV->MV
804 Overhead Three Phase Step - MV->MV
805 Pad Mounted Single Phase Step - MV<->MV
806 Pad Mounted Three Phase Step - MV<->MV
807 Pad Mounted Single Phase Step - MV->MV
808 Pad Mounted Three Phase Step - MV->MV
809 Submersible Single Phase Step - MV<->MV
810 Submersible Three Phase Step - MV<->MV
811 Submersible Single Phase Step - MV->MV
812 Submersible Three Phase Step - MV->MV
813 Station Step - MV->MV
814 Station Step - MV<->MV
815 Station Step Three Winding - MV->MV-MV
816 Overhead Three Phase Step Up - LV->MV
817 Overhead Three Phase Step Up - LV<->MV
818 Station Step Up - LV->MV
819 Station Step Up - LV<->MV
820 Pad Mounted Three Phase Step Up - LV->MV
821 Pad Mounted Three Phase Step Up - LV<->MV
822 Overhead Single Phase Step Up - LV->MV
823 Overhead Single Phase Step Up - LV<->MV
824 Pad Mounted Single Phase Step Up - LV->MV
825 Pad Mounted Single Phase Step Up - LV<->MV

Asset_Type_Electric_Device_Medium_Voltage_Transformer_Winding

Asset Types for Transformer Windings
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Transformer Winding
873 Transformer Winding MV

Asset_Type_Electric_EdgeObject_Aerial_Bare

Aerial Bare Cable
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
901 High Voltage AC
902 High Voltage DC
903 Medium Voltage
904 Low Voltage AC
905 Low Voltage DC

Asset_Type_Electric_EdgeObject_Aerial_Covered

Aerial Covered Cable
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
901 High Voltage AC
902 High Voltage DC
903 Medium Voltage
904 Low Voltage AC
905 Low Voltage DC

Asset_Type_Electric_EdgeObject_Busbar

Busbar
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
901 High Voltage AC
902 High Voltage DC
903 Medium Voltage
904 Low Voltage AC
905 Low Voltage DC

Asset_Type_Electric_EdgeObject_Connector

Valid Connector Asset Types
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
901 High Voltage AC
902 High Voltage DC
903 Medium Voltage
904 Low Voltage AC
905 Low Voltage DC

Asset_Type_Electric_EdgeObject_Ground

Ground
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
921 Covered Ground
922 Bare Ground

Asset_Type_Electric_EdgeObject_Neutral

Neutral
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
910 Overhead Bare
911 Overhead Shielded
912 Underground Shielded
913 Concentric

Asset_Type_Electric_EdgeObject_Submarine

Submarine Cable
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
901 High Voltage AC
902 High Voltage DC
903 Medium Voltage
904 Low Voltage AC
905 Low Voltage DC

Asset_Type_Electric_EdgeObject_Underground

Underground
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
901 High Voltage AC
902 High Voltage DC
903 Medium Voltage
904 Low Voltage AC
905 Low Voltage DC

Asset_Type_Electric_JunctionObject_Aerial_Bare

Aerial Bare Cable
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
901 High Voltage AC
902 High Voltage DC
903 Medium Voltage
904 Low Voltage AC
905 Low Voltage DC

Asset_Type_Electric_JunctionObject_Aerial_Covered

Aerial Covered Cable
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
901 High Voltage AC
902 High Voltage DC
903 Medium Voltage
904 Low Voltage AC
905 Low Voltage DC

Asset_Type_Electric_JunctionObject_Busbar

Busbar
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
901 High Voltage AC
902 High Voltage DC
903 Medium Voltage
904 Low Voltage AC
905 Low Voltage DC

Asset_Type_Electric_JunctionObject_Conductor_Configuration

Asset Types for Conductor Configuraiton Information
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
940 Overhead
941 Underground

Asset_Type_Electric_JunctionObject_Connector

Valid Connector Asset Types
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
901 High Voltage AC
902 High Voltage DC
903 Medium Voltage
904 Low Voltage AC
905 Low Voltage DC

Asset_Type_Electric_JunctionObject_Ground

Ground
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Ground
31 Bound
32 Rod
33 Voltage Grid
34 Stray Voltage Isolator
35 Grounding Switch
36 Cross Bond
37 Ground Plate
38 Ground Joint

Asset_Type_Electric_JunctionObject_Ground_Wire

Ground
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
921 Covered Ground
922 Bare Ground

Asset_Type_Electric_JunctionObject_High_Voltage_Arrester

High Voltage Arrester
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Arrester
21 Indoor Arrester HV
22 Line Arrester HV
23 Station Arrester HV
24 Indoor Insulator HV
25 Line Insulator HV
26 Station Insulator HV

Asset_Type_Electric_JunctionObject_High_Voltage_Control_Unit

High Voltage Controller
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Control Unit
41 Capacitor HV
42 Switch and Breaker HV
43 Voltage Regulator HV

Asset_Type_Electric_JunctionObject_High_Voltage_Fuse

High Voltage Fuse
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Fuse
581 AC Station Disconnect Fuse HV
582 AC Station Load Break Fuse HV
583 AC Load Break Disconnect Fuse HV
584 AC Load Break Fuse HV - Controller
585 AC Disconnect Fuse HV - Controller
586 AC Load Break Disconnect Fuse HV - Controller

Asset_Type_Electric_JunctionObject_High_Voltage_Generation

High Voltage Generation
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Generation
61 Battery HV
62 Biomass HV
63 Coal HV
64 Gas Turbine HV
65 Geothermal HV
66 Hydro HV
67 Nuclear HV
68 Photovoltaic Solar HV
69 Thermal Solar HV
70 Wind HV
71 AC Wave HV
72 Generator HV
73 Interconnect HV

Asset_Type_Electric_JunctionObject_High_Voltage_Line_Monitor_and_Relay

High Voltage Line Monitor and Relay
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Line Monitor and Relay
80 Fault Indicator HV
81 Instrument Transformer HV
82 Load Monitor HV
83 Relay HV

Asset_Type_Electric_JunctionObject_High_Voltage_Power_Conversion

High Voltage Power Conversion
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Power Conversion
101 Inverter HV
102 Rectifier HV
103 Bidirectional HV

Asset_Type_Electric_JunctionObject_High_Voltage_Power_Factor_Correcting

High Voltage Power Factor Correcting
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Power Factor Correcting
121 AC Capacitor HV
122 AC Wave Trap HV
123 AC Reactor HV
124 DC Capacitor HV
125 DC Reactor HV
126 Synchronous Condenser HV

Asset_Type_Electric_JunctionObject_High_Voltage_Regulator

High Voltage Regulator
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Regulator
171 AC Single Phase HV
172 AC Three Phase HV
173 DC Regulator HV
174 Frequency Converter HV

Asset_Type_Electric_JunctionObject_High_Voltage_Service

High Voltage Service
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Service
161 AC Metering HV
162 DC Metering HV
163 High Voltage Premise HV

Asset_Type_Electric_JunctionObject_High_Voltage_Switch

High Voltage Switch
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Switch
181 AC Circuit Breaker HV
182 AC Disconnect HV
183 AC Switchgear HV
184 DC Circuit Breaker HV
185 DC Disconnect HV
186 DC Switchgear HV
187 AC Bus Tie Breaker HV
188 DC Bus Tie Breaker HV
189 AC Disconnect - Grounded HV
190 AC Recloser HV
191 AC Circuit Breaker HV - Controller
192 AC Station Load Break Disconnect HV
193 AC Station Load Break Disconnect HV - Controller
194 DC Circuit Breaker HV - Controller
195 AC Disconnect HV - Controller
196 AC Grounding HV
197 AC Thyristor HV
198 DC Thyristor HV
199 AC Transfer Switch HV

Asset_Type_Electric_JunctionObject_HIgh_Voltage_Tap_Changer

Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
925 Tap Changer Controller HV
926 Regulator Tap Changer HV
927 Transformer Tap Changer HV

Asset_Type_Electric_JunctionObject_High_Voltage_Transformer

High Voltage Transformer
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Transformer
201 AC Single Phase - HV->MV
202 AC Three Phase - HV->MV
203 DC Power - HV->HV
204 Grounding Transformer - HV->MV
205 Station - HV->MV
206 Station Three Winding - HV->HV-HV
207 Station Three Winding - HV->HV-MV
208 Phase Control - HV->HV
209 Station Three Winding - HV->HV-LV
210 Station Step Up - MV->HV
211 Station Step - HV->HV
212 Station Three Winding - HV->MV-MV
213 Station Three Winding - HV->MV-LV

Asset_Type_Electric_JunctionObject_High_Voltage_Transformer_Winding

Asset Types for Transformer Windings
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Transformer Winding
871 AC Transformer Winding HV
872 DC Transformer Winding HV

Asset_Type_Electric_JunctionObject_Line_Hardware

Asset Types for equipment that connects electric lines to towers and poles
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Line Hardware
833 Corona Ring
834 Damper
836 Spacer
837 Aerial Marker
838 Buried Cable Marker
839 Submerged Cable Marker
840 Overhead Water Crossing Marker
841 Airflow Spoiler
842 Bird Diverter
843 Line Weight

Asset_Type_Electric_JunctionObject_Low_Voltage_Arrester

Low Voltage Arrester
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Arrester
221 Overhead Arrester LV
222 Underground Arrester LV
223 Station Arrester LV
224 Indoor Arrester LV
225 Overhead Insulator LV
226 Underground Insulator LV
227 Station Insulator LV
228 Indoor Insulator LV

Asset_Type_Electric_JunctionObject_Low_Voltage_Circuit_Breaker

Asset Types for Low Voltage Circuit Breakers
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Circuit Breaker
1 AC Overhead
2 AC Underground
3 AC Station
4 AC Overhead - Controller
5 AC Underground - Controller
6 AC Station - Controller
11 DC Overhead
12 DC Underground
13 DC Station
14 DC Overhead - Controller
15 DC Underground - Controller
16 DC Station - Controller
471 AC Circuit Breaker LV
472 DC Circuit Breaker LV
473 AC Circuit Breaker LV - Controller
474 DC Circuit Breaker LV - Controller

Asset_Type_Electric_JunctionObject_Low_Voltage_Control_Unit

Low Voltage Controller
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Control Unit
241 Control Unit LV

Asset_Type_Electric_JunctionObject_Low_Voltage_Fuse

Low Voltage Fuse
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Fuse
1 AC Overhead
2 AC Underground
3 AC Station
4 AC Overhead - Controller
5 AC Underground - Controller
6 AC Station - Controller
11 DC Overhead
12 DC Underground
13 DC Station
14 DC Overhead - Controller
15 DC Underground - Controller
16 DC Station - Controller
259 Service Fuse Load Break LV
260 Service Fuse Disconnect LV
261 AC Overhead Fuse LV
262 AC Underground Fuse LV
263 DC Overhead Fuse LV
264 DC Underground Fuse LV
265 AC Overhead Load Break Fuse LV
266 AC Overhead Fuse LV - Controller
267 AC Underground Load Break Fuse LV
268 AC Underground Fuse LV - Controller
269 DC Overhead Fuse LV - Controller
270 DC Underground Fuse LV - Controller
271 AC Overhead Cutout Load Break Disconnect Fuse LV
272 AC Overhead Cutout Load Break Fuse LV - Controller
273 AC Overhead Cutout Disconnect Fuse LV - Controller
274 AC Overhead Cutout Load Break Fuse LV
275 Station Disconnect Fuse LV
276 Station Load Break Fuse LV
277 Station Load Break Disconnect Fuse LV
278 Station Disconnect Fuse LV - Controller
279 Station Load Break Fuse LV - Controller
280 Station Load Break Disconnect Fuse LV - Controller

Asset_Type_Electric_JunctionObject_Low_Voltage_Generation

Low Voltage Generation
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Generation
281 Battery LV
283 Generator LV
284 Residential Photovoltaic Solar LV
285 Wind Turbine LV
286 AC Wave LV
428 Car Charger LV

Asset_Type_Electric_JunctionObject_Low_Voltage_Lighting

Low Voltage Lighting
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Lighting
301 Floodlight LV
302 Streetlight LV

Asset_Type_Electric_JunctionObject_Low_Voltage_Line_Monitor_and_Relay

Low Voltage Line Monitor and Relay
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Line Monitor and Relay
321 Fault Indicator LV
322 Load Monitor LV
323 Relay LV
324 Instrument Transformer LV

Asset_Type_Electric_JunctionObject_Low_Voltage_Motor

Low Voltage Motor
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Motor
341 Single Phase Motor LV
342 Three Phase Motor LV
343 DC Motor LV

Asset_Type_Electric_JunctionObject_Low_Voltage_Network_Protection

Low Voltage Network Protection
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Network Protector
361 Network Protector LV

Asset_Type_Electric_JunctionObject_Low_Voltage_Power_Conversion

Low Voltage Power Conversion
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Power Conversion
381 Single Phase Inverter LV
382 Single Phase Rectifier LV
383 Three Phase Inverter LV
384 Three Phase Rectifier LV
386 Single Phase Bidirectional LV
387 Three Phase Bidirectional LV
390 Wave Trap LV

Asset_Type_Electric_JunctionObject_Low_Voltage_Power_Factor_Correcting

Low Voltage Power Factor Correcting
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Power Factor Correcting
1 AC Overhead
2 AC Underground
3 AC Station
4 AC Overhead - Controller
5 AC Underground - Controller
6 AC Station - Controller
11 DC Overhead
12 DC Underground
13 DC Station
14 DC Overhead Directional
15 DC Underground Directional
16 DC Station Directional
401 Mobile Harmonic Filter LV
402 Mobile Reactor LV
403 Overhead Capacitor LV
404 Overhead Harmonic Filter LV
405 Overhead Reactor LV
406 Pad Mounted Capacitor LV
407 Pad Mounted Harmonic Filter LV
408 Pad Mounted Reactor LV
409 Station Capacitor LV
410 Station Harmonic Filter LV
411 Station Reactor LV

Asset_Type_Electric_JunctionObject_Low_Voltage_Regulator

List of Low Voltage Regulators
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Regulator
141 AC Single Phase LV
142 AC Three Phase LV
143 DC Regulator LV
144 Network Load Balancer LV
145 Frequency Converter LV

Asset_Type_Electric_JunctionObject_Low_Voltage_Service

Low Voltage Service
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Service
421 Single Phase Commercial LV
422 Single Phase Residential LV
423 Three Phase Commercial LV
424 Three Phase Residential LV
425 Unmetered Load LV
426 DC Commercial LV
427 Low Voltage Premise LV
428 Car Charger LV

Asset_Type_Electric_JunctionObject_Low_Voltage_Switch

Low Voltage Switch
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Switch
1 AC Overhead
2 AC Underground
3 AC Station
4 AC Overhead - Controller
5 AC Underground - Controller
6 AC Station - Controller
11 DC Overhead
12 DC Underground
13 DC Station
14 DC Overhead - Controller
15 DC Underground - Controller
16 DC Station - Controller
431 AC Station Disconnect LV
432 AC Station Load Break LV
433 AC Station Load Break Disconnect LV
434 AC Station Disconnect LV - Controller
435 AC Station Load Break LV - Controller
436 AC Station Load Break Disconnect LV - Controller
441 Overhead AC Load Break LV
442 Overhead AC Disconnect LV
443 Overhead DC Load Break LV
444 Overhead DC Disconnect LV
445 Underground AC Load Break LV
446 Underground AC Disconnect LV
447 Underground DC Load Break LV
448 Underground DC Disconnect LV
449 Indoor AC Load Break LV
450 Indoor AC Disconnect LV
451 Indoor DC Load Break LV
452 Indoor DC Disconnect LV
453 Source Selectable Switch LV
454 Overhead Jumper LV
456 DC Station LV
457 AC Station Bypass LV
458 AC Recloser LV

Asset_Type_Electric_JunctionObject_Low_Voltage_Transformer

Low Voltage Transformer
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Transformer
461 Single Phase - LV->LV
462 Three Phase - LV->LV
463 Three Winding - LV->LV-LV

Asset_Type_Electric_JunctionObject_Low_Voltage_Transformer_Winding

Asset Types for Transformer Windings
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Transformer Winding
874 AC Transformer Winding LV
875 DC Transformer Winding LV

Asset_Type_Electric_JunctionObject_Low_Voltage_Wire_Connector

Low Voltage Connectors
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Wire Connector
861 Ring Terminal LV

Asset_Type_Electric_JunctionObject_Medium_Voltage_Arrester

Medium Voltage Arrester
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Arrester
481 Elbow Arrester MV
482 Line Arrester MV
483 Station Arrester MV
484 Underground Insulator MV
485 Line Insulator MV
486 Station Insulator MV

Asset_Type_Electric_JunctionObject_Medium_Voltage_Circuit_Breaker

Medium Voltage Circuit Breaker
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Circuit Breaker
501 Isolator Switch MV
502 Single Phase Circuit Breaker MV
503 Three Phase Circuit Breaker MV
512 Single Phase Circuit Breaker MV - Controller
513 Three Phase Circuit Breaker MV - Controller
515 Network Protector MV

Asset_Type_Electric_JunctionObject_Medium_Voltage_Control_Unit

Medium Voltage Controller
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Control Unit
521 Capacitor MV
522 Circuit Breaker MV
523 Recloser MV
524 Transfer Switch Controller MV
525 Regulator MV

Asset_Type_Electric_JunctionObject_Medium_Voltage_Elbow

Medium Voltage Elbow
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Elbow
2 AC Underground
5 AC Underground - Controller
541 Load Break Feedthru MV
542 Load Break Junction MV
543 Single Phase Dead Break MV
544 Single Phase Load Break MV
545 Three Phase Dead Break MV
546 Three Phase Load Break MV

Asset_Type_Electric_JunctionObject_Medium_Voltage_Fuse

Medium Voltage Fuse
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Fuse
1 AC Overhead
2 AC Underground
3 AC Station
4 AC Overhead - Controller
5 AC Underground - Controller
6 AC Station - Controller
561 Bayonet Fuse MV
562 Fault Limiter Fuse MV
563 Indoor Fuse MV
564 Overhead Cutout Disconnect Fuse MV
565 Overhead Cutout Load Break Fuse MV
566 Overhead Cutout Sectionalizer Fuse MV
567 Overhead Cutout Solid Blade Fuse MV
568 Cabinet Fuse MV
569 Underground Fuse MV
570 Underground Disconnect Fuse MV
571 Underground Load Break Fuse MV
572 Overhead Cutout Load Break Disconnect Fuse MV
573 Overhead Cutout Load Break Fuse MV - Controller
574 Overhead Cutout Disconnect Fuse MV - Controller
575 Overhead Cutout Load Break Disconnect Fuse MV - Controller

Asset_Type_Electric_JunctionObject_Medium_Voltage_Generation

Medium Voltage Generation
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Generation
110 AC Wave MV
111 Battery MV
112 Biomass MV
113 Generator MV
114 Gas Turbine MV
115 Geothermal MV
116 Hydro MV
117 Wind MV
118 Photovoltaic Solar MV
119 Thermal Solar MV
120 Interconnect MV

Asset_Type_Electric_JunctionObject_Medium_Voltage_Line_Monitor_and_Relay

Medium Voltage Line Monitor and Relay
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Line Monitor and Relay
601 Fault Indicator MV
602 Instrument Transformer MV
603 Programmable Logic Unit MV
604 Remote Terminal Unit MV
605 SCADA Load Monitor MV
606 SCADA Weather Station MV
607 Relay MV

Asset_Type_Electric_JunctionObject_Medium_Voltage_Motor_and_Pump

Medium Voltage Motor & Pump
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Motor and Pump
621 Single Phase Motor MV
622 Single Phase Pump MV
623 Three Phase Motor MV
624 Three Phase Pump MV

Asset_Type_Electric_JunctionObject_Medium_Voltage_Power_Conversion

Medium Voltage Power Conversion
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Power Conversion
641 Single Phase Inverter MV
642 Single Phase Rectifier MV
643 Three Phase Inverter MV
644 Three Phase Rectifier MV
645 Single Phase Bidirectional MV
646 Three Phase Bidirectional MV
647 Wave Trap MV

Asset_Type_Electric_JunctionObject_Medium_Voltage_Power_Factor_Correcting

Medium Voltage Power Factor Correcting
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Power Factor Correcting
1 AC Overhead
2 AC Underground
3 AC Station
4 AC Overhead - Controller
5 AC Underground - Controller
6 AC Station - Controller
661 Mobile Capacitor MV
664 Overhead Single Phase Capacitor MV
665 Overhead Three Phase Capacitor MV
666 Overhead Harmonic Filter MV
667 Overhead Reactor MV
668 Pad Mounted Single Phase Capacitor MV
669 Pad Mounted Three Phase Capacitor MV
671 Mobile Harmonic Filter MV
672 Mobile Reactor MV
673 Pad Mounted Harmonic Filter MV
674 Pad Mounted Reactor MV
675 Station Capacitor MV
676 Station Harmonic Filter MV
677 Station Reactor MV
678 Synchronous Condenser MV

Asset_Type_Electric_JunctionObject_Medium_Voltage_Recloser

Medium Voltage Recloser
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Recloser
1 AC Overhead
2 AC Underground
4 AC Overhead - Controller
5 AC Underground - Controller
730 Overhead Single Phase Recloser MV
734 Overhead Three Phase Recloser MV - Controller
738 Pad Mounted Three Phase Recloser MV - Controller
744 Overhead Three Phase Recloser MV
747 Pad Mounted Single Phase Recloser MV
748 Pad Mounted Three Phase Recloser MV

Asset_Type_Electric_JunctionObject_Medium_Voltage_Regulator

Medium Voltage Regulator
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Regulator
1 AC Overhead
2 AC Underground
3 AC Station
4 AC Overhead - Controller
5 AC Underground - Controller
681 Overhead Single Phase VR MV
683 Overhead Three Phase VR MV
685 Pad Mounted Single Phase VR MV
687 Pad Mounted Three Phase VR MV
688 Frequency Converter MV

Asset_Type_Electric_JunctionObject_Medium_Voltage_Sectionalizer

Medium Voltage Secitionalizer
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Sectionalizer
1 AC Overhead
2 AC Underground
4 AC Overhead - Controller
5 AC Underground - Controller
731 Overhead Single Phase Sectionalizer MV
745 Overhead Three Phase Sectionalizer MV
749 Pad Mounted Single Phase Sectionalizer MV
750 Pad Mounted Three Phase Sectionalizer MV

Asset_Type_Electric_JunctionObject_Medium_Voltage_Service

Medium Voltage Service
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Service
701 Primary Meter - Industrial Customer MV
702 Primary Meter - Utility Customer MV
703 Primary Meter Circuit Source MV
704 Medium Voltage Premise MV

Asset_Type_Electric_JunctionObject_Medium_Voltage_Switch

Medium Voltage Switch
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Switch
1 AC Overhead
2 AC Underground
3 AC Station
4 AC Overhead - Controller
5 AC Underground - Controller
6 AC Station - Controller
721 Cabinet Bypass MV
722 Cabinet Switch MV
723 Cabinet Switch - Grounded MV
724 Overhead Bypass MV
725 Overhead Grounding Switch MV
726 Overhead Jumper MV
727 Station Grounding MV
728 Overhead Single Phase Disconnect MV
729 Overhead Single Phase Load Break MV
732 Overhead Three Phase Disconnect MV
733 Overhead Three Phase Load Break MV
746 Pad Mounted Fault Interrupter MV
751 Station Single Phase Disconnect MV
752 Station Disconnect MV
753 T Blade MV
754 V Blade MV
755 Underground Single Phase Disconnect MV
758 Underground Single Phase Load Break MV
759 Underground Three Phase Disconnect MV
760 Underground Three Phase Load Break MV
761 Underground Transfer Switch MV
765 Bus Tie Breaker MV
766 Station Load Break MV
768 Station Disconnect - Grounded MV
769 Station Load Break Disconnect MV
770 Station Disconnect MV - Controller
771 Station Load Break MV - Controller
772 Station Load Break Disconnect MV - Controller

Asset_Type_Electric_JunctionObject_Medium_Voltage_Tap_Changer

Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
930 Tap Changer Controller MV
931 Regulator Tap Changer MV
932 Transformer Tap Changer MV

Asset_Type_Electric_JunctionObject_Medium_Voltage_Transformer

Medium Voltage Transformer
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Transformer
781 Grounding Transformer - MV->MV
782 Mobile Single Phase - MV->LV
783 Mobile Three Phase - MV->LV
784 Network - MV->LV
785 Overhead Single Phase - MV->LV
786 Station - MV->LV
787 Station Three Winding - MV->LV-LV
788 Overhead Three Phase - MV->LV
789 Pad Mounted Single Phase - MV->LV
790 Station Three Winding - MV->MV-LV
792 Pad Mounted Three Phase - MV->LV
793 Submersible Single Phase - MV->LV
794 Submersible Three Phase - MV->LV
801 Overhead Single Phase Step - MV<->MV
802 Overhead Three Phase Step - MV<->MV
803 Overhead Single Phase Step - MV->MV
804 Overhead Three Phase Step - MV->MV
805 Pad Mounted Single Phase Step - MV<->MV
806 Pad Mounted Three Phase Step - MV<->MV
807 Pad Mounted Single Phase Step - MV->MV
808 Pad Mounted Three Phase Step - MV->MV
809 Submersible Single Phase Step - MV<->MV
810 Submersible Three Phase Step - MV<->MV
811 Submersible Single Phase Step - MV->MV
812 Submersible Three Phase Step - MV->MV
813 Station Step - MV->MV
814 Station Step - MV<->MV
815 Station Step Three Winding - MV->MV-MV
816 Overhead Three Phase Step Up - LV->MV
817 Overhead Three Phase Step Up - LV<->MV
818 Station Step Up - LV->MV
819 Station Step Up - LV<->MV
820 Pad Mounted Three Phase Step Up - LV->MV
821 Pad Mounted Three Phase Step Up - LV<->MV
822 Overhead Single Phase Step Up - LV->MV
823 Overhead Single Phase Step Up - LV<->MV
824 Pad Mounted Single Phase Step Up - LV->MV
825 Pad Mounted Single Phase Step Up - LV<->MV

Asset_Type_Electric_JunctionObject_Medium_Voltage_Transformer_Winding

Asset Types for Transformer Windings
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Transformer Winding
873 Transformer Winding MV

Asset_Type_Electric_JunctionObject_Neutral

Neutral
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
910 Overhead Bare
911 Overhead Shielded
912 Underground Shielded
913 Concentric

Asset_Type_Electric_JunctionObject_Submarine

Submarine Cable
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
901 High Voltage AC
902 High Voltage DC
903 Medium Voltage
904 Low Voltage AC
905 Low Voltage DC

Asset_Type_Electric_JunctionObject_Underground

Underground
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
901 High Voltage AC
902 High Voltage DC
903 Medium Voltage
904 Low Voltage AC
905 Low Voltage DC

Asset_Type_Electric_Junction_Ground_Attachment

Asset Types for the Ground Attachment junction Asset Group
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
201 Ground Joint
203 Neutral Joint

Asset_Type_Electric_Junction_High_Voltage_Attachment

High Voltage Attachment
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 AC Overhead HV
2 AC Underground HV
3 DC Overhead HV
4 DC Underground HV
5 AC Riser HV
6 DC Riser HV
7 AC Submersible HV
8 DC Submersible HV

Asset_Type_Electric_Junction_High_Voltage_Connection_Point

High Voltage Connection Point
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
21 AC Tap HV
23 DC Tap HV
24 AC Busbar Tap HV
25 DC Busbar Tap HV
36 AC Bond Connection HV
37 DC Bond Connection HV
45 AC Busbar Connection HV
46 DC Busbar Connection HV

Asset_Type_Electric_Junction_High_Voltage_Line_End

High Voltage Line End
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
20 AC Overhead Splice HV
22 DC Overhead Splice HV
40 AC Service Connection HV
41 AC Overhead Line End HV
42 DC Overhead Line End HV
43 AC Underground Terminator HV
44 DC Underground Terminator HV
47 AC SLTE HV
48 DC SLTE HV
49 Insulating Cap HV
51 AC Straight Joint HV
52 DC Straight Joint HV
53 AC T Joint HV
54 DC T Joint HV

Asset_Type_Electric_Junction_Low_Voltage_Attachment

Low Voltage Attachment
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
101 AC Overhead LV
102 AC Underground LV
103 DC Overhead LV
104 DC Underground LV
105 AC Riser LV
106 DC Riser LV
107 AC Submersible LV
108 DC Submersible LV

Asset_Type_Electric_Junction_Low_Voltage_Connection_Point

Low Voltage Connection Point
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
124 AC Busbar Tap LV
125 DC Busbar Tap LV
128 AC Overhead Tap LV
129 DC Overhead Tap LV
134 AC Underground Phase Connector LV
135 DC Underground Phase Connector LV
136 AC Bond Connection LV
137 DC Bond Connection LV
145 AC Busbar Connection LV
146 DC Busbar Connection LV

Asset_Type_Electric_Junction_Low_Voltage_Line_End

Low Voltage Line End
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
120 AC Overhead Splice LV
121 DC Overhead Splice LV
126 AC Underground Splice LV
127 DC Underground Splice LV
140 AC Service Connection LV
141 AC Overhead Line End LV
142 DC Overhead Line End LV
143 AC Underground Terminator LV
144 DC Underground Terminator LV
147 AC SLTE LV
148 DC SLTE LV
149 AC Overhead Wire Change LV
150 Insulating Cap LV
151 AC Straight Joint LV
152 DC Straight Joint LV
153 AC T Joint LV
154 DC T Joint LV
155 AC Open Point LV
156 DC Open Point LV

Asset_Type_Electric_Junction_Medium_Voltage_Attachment

Medium Voltage Attachment
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
60 Overhead MV
61 Underground MV
62 Riser MV
63 Submersible MV

Asset_Type_Electric_Junction_Medium_Voltage_Connection_Point

Medium Voltage Connection Point
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
80 Busbar Tap MV
82 Overhead Tap MV
85 Neutral Connection MV
87 Underground Phase Connector MV
96 Bond Connection MV
160 Busbar Connection MV

Asset_Type_Electric_Junction_Medium_Voltage_Line_End

Medium Voltage Line End
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
81 Overhead Splice MV
84 Underground Splice MV
161 Overhead Line End MV
162 Underground Terminator MV
163 Overhead Wire Change MV
164 Underground Wire Change MV
167 SLTE MV
168 Sealed Short-Circuited Terminator MV
169 Service Connection MV
170 Insulating Cap MV
171 Straight Joint MV
172 T Joint MV
173 Open Point MV

Asset_Type_Electric_Line_Ground

Ground
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
221 Covered Ground
222 Bare Ground

Asset_Type_Electric_Line_High_Voltage_Busbar

High Voltage Busbar
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 AC Station Single Phase HV
2 AC Station Three Phase HV
3 DC Station HV

Asset_Type_Electric_Line_High_Voltage_Connector

High Voltage Connector
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
40 AC Connector HV
41 DC Connector HV

Asset_Type_Electric_Line_High_Voltage_Overhead_Conductor

High Voltage Conductor
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
20 AC Overhead HV
23 DC Overhead HV

Asset_Type_Electric_Line_High_Voltage_Service

High Voltage Service Lines
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
260 AC Overhead Service HV
261 AC Underground Service HV
262 DC Overhead Service HV
263 DC Underground Service HV
264 AC Submersible Service HV
265 DC Submersible Service HV

Asset_Type_Electric_Line_High_Voltage_Static_Wire

High Voltage Static Wire
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
60 Double
61 Single

Asset_Type_Electric_Line_High_Voltage_Submersible_Conductor

High VoltageSubmersibleConductor
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
21 AC Submersible HV
24 DC Submersible HV

Asset_Type_Electric_Line_High_Voltage_Underground_Conductor

High VoltageUndergroundConductor
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
22 AC Underground HV
25 DC Underground HV

Asset_Type_Electric_Line_Low_Voltage_Busbar

Low Voltage Busbar
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
80 AC Cabinet LV
81 AC Station LV
82 DC Cabinet LV
83 DC Station LV

Asset_Type_Electric_Line_Low_Voltage_Connector

Low Voltage Connector
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
120 AC Connector LV
121 DC Connector LV

Asset_Type_Electric_Line_Low_Voltage_Overhead_Conductor

Low Voltage Conductor
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
100 AC Overhead LV
103 DC Overhead LV

Asset_Type_Electric_Line_Low_Voltage_Service

List of asset types for Low Voltage Services
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
110 AC Overhead Service LV
112 AC Underground Service LV
113 DC Overhead Service LV
115 DC Underground Service LV

Asset_Type_Electric_Line_Low_Voltage_Submersible_Conductor

Low VoltageSubmersibleConductor
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
101 AC Submersible LV
104 DC Submersible LV

Asset_Type_Electric_Line_Low_Voltage_Underground_Conductor

Low VoltageUndergroundConductor
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
102 AC Underground LV
105 DC Underground LV

Asset_Type_Electric_Line_Medium_Voltage_Busbar

Medium Voltage Busbar
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
140 Cabinet Single Phase MV
141 Cabinet Three Phase MV
142 Station Single Phase MV
143 Station Three Phase MV

Asset_Type_Electric_Line_Medium_Voltage_Connector

Medium Voltage Connector
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
180 Single Phase MV
181 Three Phase MV
182 Two Phase MV

Asset_Type_Electric_Line_Medium_Voltage_Overhead_Conductor

Medium Voltage Conductor
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
160 Overhead Single Phase MV
161 Overhead Three Phase MV
162 Overhead Two Phase MV

Asset_Type_Electric_Line_Medium_Voltage_Service

Medium Voltage Service Lines
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
170 Overhead Single Phase Service MV
171 Overhead Three Phase Service MV
172 Overhead Two Phase Service MV
173 Submersible Single Phase Service MV
174 Submersible Three Phase Service MV
175 Underground Single Phase Service MV
176 Underground Three Phase Service MV
177 Underground Two Phase Service MV

Asset_Type_Electric_Line_Medium_Voltage_Submersible_Conductor

Medium VoltageSubmersibleConductor
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
163 Submersible Single Phase MV
164 Submersible Three Phase MV

Asset_Type_Electric_Line_Medium_Voltage_Underground_Conductor

Medium VoltageUndergroundConductor
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
165 Underground Single Phase MV
166 Underground Three Phase MV
167 Underground Two Phase MV

Asset_Type_Electric_Line_Neutral

Neutral
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
200 Overhead Bare
201 Overhead Shielded
202 Underground Shielded

Asset_Type_Structure_Boundary_Building

Asset Types for Building Boundaries
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
801 Building
802 Room
803 Roof Covering
804 Generation Power House
805 Generation Control Center

Asset_Type_Structure_Boundary_Communications_Wire_Vault_Boundary

Polygon used to store the perimeter of vault
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Vault Boundary
3 Vault Wall
4 Vault Floor
5 Vault Knockout
6 Manhole

Asset_Type_Structure_Boundary_Electric_Bay_Boundary

The Asset Types for the Electric Distribution Asset Group Bay Boundary
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
201 Switchgear Bay
202 Substation Bay

Asset_Type_Structure_Boundary_Electric_Centralized_Generation

Centralized Generation
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
21 Battery
22 Biomass
23 Coal
24 Gas Turbine
25 Geothermal
26 Hydro
27 Nuclear
28 Photovoltaic Solar
29 Thermal Solar
30 Wind

Asset_Type_Structure_Boundary_Electric_Distributed_Generation

Distributed_Generation
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
21 Battery
22 Biomass
24 Gas Turbine
25 Geothermal
26 Hydro
28 Photovoltaic Solar
29 Thermal Solar
30 Wind

Asset_Type_Structure_Boundary_Electric_Storage_Facility_Boundary

The Asset Types for the Electric Distribution Asset Group Storage Facility Boundary
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
121 Warehouse
122 Yard

Asset_Type_Structure_Boundary_Electric_Substation_Boundary

The Asset Types for the Electric Distribution Asset Group Substation Boundary
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
82 Distribution Substation Medium Voltage Station
83 Transmission Substation High Voltage Station
84 Transmission Switching Station High Voltage Switch Yard
85 Distribution Switching Station
86 Secondary Station
87 Subtransmission Substation
88 Transmission Metering Station
89 Transmission Terminal Station

Asset_Type_Structure_Boundary_Electric_Switchgear_Boundary

The Asset Types for the Electric Distribution Asset Group Switchgear Boundary
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
161 Medium Voltage Switchgear MV Switch Cabinet|MV Switch Cubicle
162 High Voltage Switchgear HV Switch Cabinet|HV Switch Cubicle

Asset_Type_Structure_Boundary_Electric_Zone

Asset Types for Electric Zones
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
561 Protection Zone
562 Switching Zone

Asset_Type_Structure_Boundary_Support

List of valid support boundaries
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
815 Bridge
816 Casing
817 Culvert
818 Duct
819 Foundation
820 Pad
821 Path - Marine
822 Path - On Ground
823 Path - Overhead
824 Path - Trench

Asset_Type_Structure_Boundary_Wire_Cabinet_Boundary

The Asset Types for the Electric Distribution Asset Group Cabinet Boundary
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
40 Cabinet Boundary

Asset_Type_Structure_EdgeObject_Communications_Conduit

List of Conduit types
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
111 Conduit

Asset_Type_Structure_EdgeObject_Ground

Asset Types for Ground Cables
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
801 Bare Ground
802 Covered Ground

Asset_Type_Structure_EdgeObject_Wire_Aerial_Support

Valid Asset Types for Aerial support objects
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
128 Guy Wire

Asset_Type_Structure_EdgeObject_Wire_Duct

Edge objects used to represent different ducts in the Structure Network
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
41 Duct
42 Microduct Casing
43 Microduct
44 Innerduct

Asset_Type_Structure_JunctionObject_Aerial_Support_Hardware

Junctions used to represent support poles in the Structure Network
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
103 Tower Base
104 Tower Beam
105 Tower Diagonal
106 Tower Ground Wire Peak
109 Cable Guards
110 Brace
111 Down Guy
112 Guy Strain
113 Messenger Hanger
114 Platform
115 Push Pole Brace
116 Pole Top Cap
117 Wildlife Protector
118 Aerial Lighting

Asset_Type_Structure_JunctionObject_Communications_Conduit_Fittings

List of Conduit Fitings
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
141 Elbow
142 Sweep Tee
143 Y Splitter

Asset_Type_Structure_JunctionObject_Crossarm

List of valid Crossarm Types
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Dead End
2 Tangent

Asset_Type_Structure_JunctionObject_Electric_High_Voltage_Cable_Pathway

Pathway for High Voltage cables
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
231 Overhead Pathway HV
232 Underground Pathway HV
233 Submersible Pathway HV

Asset_Type_Structure_JunctionObject_Electric_Low_Voltage_Cable_Pathway

Pathway for Low Voltage cables
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
251 Overhead Pathway LV
252 Underground Pathway LV
253 Submersible Pathway LV

Asset_Type_Structure_JunctionObject_Electric_Medium_Voltage_Cable_Pathway

Pathway for Medium Voltage cables
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
241 Overhead Pathway MV
242 Underground Pathway MV
243 Submersible Pathway MV

Asset_Type_Structure_JunctionObject_Ground

Asset Types for Ground Points
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
811 Joint
812 Plate
813 Rod
814 Lightning Pole
815 Lightning Rod

Asset_Type_Structure_JunctionObject_GroundWire

Asset Types for Ground Cables
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
801 Bare Ground
802 Covered Ground

Asset_Type_Structure_JunctionObject_Pole

Junctions used to represent support poles in the Structure Network
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
101 Pole
102 Ornamental Pole
107 Tower Leg

Asset_Type_Structure_JunctionObject_Wire_Building_Riser

Building Riser
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
396 Building Riser

Asset_Type_Structure_JunctionObject_Wire_Microduct_Connection_Point

Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
378 Wire Microduct Connection Point

Asset_Type_Structure_JunctionObject_Wire_Microduct_Fitting

Objects used to connect microducts
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
601 Microduct Connector
602 Microduct Cap

Asset_Type_Structure_JunctionObject_Wire_Microduct_Fitting_Group

Asset Types for Microduct Fittings
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
601 Microduct Connector
602 Microduct Cap

Asset_Type_Structure_JunctionObject_Wire_Vault_Knockouts

Junction Objects used to represent knockouts and ports for vaults in the Structure Network
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
371 Knockout
372 Knockout Port
373 Cross Section Position

Asset_Type_Structure_Junction_Building

Asset Types for Buildings
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
801 Building
802 Room
803 Roof Covering

Asset_Type_Structure_Junction_Communications_Conduit_Fittings

List of Conduit Fitings
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
141 Elbow
142 Sweep Tee
143 Y Splitter

Asset_Type_Structure_Junction_Communications_Pole

Junctions used to represent communication poles in the Structure Network
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
581 Pole
582 Pole with Riser

Asset_Type_Structure_Junction_Communications_Tower

Junctions used to represent communication towers in the Structure Network
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
221 Microwave Tower
222 Wireless Tower
223 Combined Tower
224 Stealth Cell Tower

Asset_Type_Structure_Junction_Crossarm

List of valid Crossarm Types
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Dead End
2 Tangent

Asset_Type_Structure_Junction_Duct_Junctions

Asset Types for Microduct Junctions
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
162 Aerial Microduct Branch Off Point
163 Underground Microduct Branch Off Point
164 Duct Bank Tap

Asset_Type_Structure_Junction_Electric_Bay

The Asset Types for the Electric Distribution Asset Group Bay
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
441 Cabinet Bay
442 Substation Bay

Asset_Type_Structure_Junction_Electric_High_Voltage_Pole

The Asset Types for the Electric Distribution Asset Group High Voltage Pole
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
330 Single Circuit Lattice HV
331 Dual Circuit Lattice HV
332 Triple Circuit Lattice HV
333 Quadruple Circuit Lattice HV
334 Gantry HV
335 H-Frame HV
336 Pole with Riser HV
337 Pole HV

Asset_Type_Structure_Junction_Electric_Low_Voltage_Pole

The Asset Types for the Electric Distribution Asset Group Low Voltage Pole
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
313 Pole with Riser LV
314 Pole LV
315 Ornamental LV
319 Lattice LV

Asset_Type_Structure_Junction_Electric_Medium_Voltage_Pole

The Asset Types for the Electric Distribution Asset Group Medium Voltage Pole
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
321 H-Frame MV
323 Pole with Riser MV
324 Pole MV
329 Lattice MV

Asset_Type_Structure_Junction_Electric_Pad

The Asset Types for the Electric Distribution Asset Group Pad
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
201 Pad

Asset_Type_Structure_Junction_Electric_Platform

The Asset Types for the Electric Distribution Asset Group Platform
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
281 Platform

Asset_Type_Structure_Junction_Electric_Station

Asset Types for Electric Stations
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
82 Distribution Substation
83 Transmission Substation
84 Transmission Switching Station
85 Distribution Switching Station
86 Secondary Station
87 Subtransmission Substation
88 Transmission Metering Station
89 Transmission Terminal Station

Asset_Type_Structure_Junction_Foundation

Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
841 Foundation

Asset_Type_Structure_Junction_Ground

Asset Types for Ground Points
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
811 Joint
812 Plate
813 Rod
814 Lightning Pole
815 Lightning Rod

Asset_Type_Structure_Junction_Marker

Junctions used to represent markers in the Structure Network
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
461 Aerial Marker
462 Buried Cable Marker
463 Overhead Water Crossing
464 Submerged Cable Marker
465 Covered Marker
466 Terrain Marker

Asset_Type_Structure_Junction_Structure_Attachment_Point

Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
391 Conduit To Knockout Port

Asset_Type_Structure_Junction_Support

List of valid support types
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
211 Tray
212 Rack
821 Shelf
823 Brace
825 Bracket
826 Hanger

Asset_Type_Structure_Junction_Transition_Point

Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
168 Transition Point

Asset_Type_Structure_Junction_Wire_Building_Riser

Building Riser
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
396 Building Riser

Asset_Type_Structure_Junction_Wire_Cabinet

The Asset Types for the Structure Junction Asset Group Wire Cabinet
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
101 Electric Cabinet
102 Communication Cabinet

Asset_Type_Structure_Junction_Wire_Customer_Attachment

The Asset Types for the Structure Junction Asset Group Customer Service Entrance
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
242 Service Entrance

Asset_Type_Structure_Junction_Wire_Guy

Junctions used to represent guy wires in the Structure Network
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
41 Anchor Guy

Asset_Type_Structure_Junction_Wire_Handhole

Junctions used to represent handholds in the Structure Network
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
81 Handhole

Asset_Type_Structure_Junction_Wire_Junction_Box

Junctions used to represent junction boxes in the Structure Network
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
121 Junction Box

Asset_Type_Structure_Junction_Wire_Pedestal

Junctions used to represent pedestals in the Structure Network
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
241 Pedestal

Asset_Type_Structure_Junction_Wire_Stock_Sites

Asset Types for Wire Stock Locations
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
261 Central Stock Site
262 District Stock Site
263 Crew Quarter Stock Site
264 Mobile Stock Site

Asset_Type_Structure_Junction_Wire_Structure_Representation

Junctions used to build representations of vaults in the Structure Network
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
375 Butterfly Diagram
376 Cross Section

Asset_Type_Structure_Junction_Wire_Support_Pole

Junctions used to represent support poles in the Structure Network
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
326 Stub
327 Push Brace
328 Support Column

Asset_Type_Structure_Junction_Wire_Vault

Junctions used to represent vaults in the Structure Network
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
361 Vault
362 Manhole

Asset_Type_Structure_Junction_Wire_Vault_Access

Junctions used to represent access locations for vaults in the Structure Network
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
161 Manhole Cover

Asset_Type_Structure_Junction_Wire_Vault_Knockouts

Junctions used to represent knockouts and ports for vaults in the Structure Network
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
371 Knockout
372 Knockout Port
373 Cross Section Position

Asset_Type_Structure_Line_Communications_Conduit

Lines used to represent conduit in the Structure Network
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
111 Conduit

Asset_Type_Structure_Line_Connector

Lines used to represent connecters inside vaults and handholes in the Structure Network
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
181 Vault Duct
182 Handhole Duct

Asset_Type_Structure_Line_Electric_High_Voltage_Cable_Pathway

Pathway for High Voltage cables
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
231 Overhead Pathway HV
232 Underground Pathway HV
233 Submersible Pathway HV

Asset_Type_Structure_Line_Electric_High_Voltage_Conduit

The Asset Types for the Electric High Voltage Conduit
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
114 Conduit HV

Asset_Type_Structure_Line_Electric_Low_Voltage_Cable_Pathway

Pathway for Low Voltage cables
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
251 Overhead Pathway LV
252 Underground Pathway LV
253 Submersible Pathway LV

Asset_Type_Structure_Line_Electric_Low_Voltage_Conduit

The Asset Types for the Electric Low Voltage Conduit
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
118 Conduit LV

Asset_Type_Structure_Line_Electric_Medium_Voltage_Cable_Pathway

Pathway for Medium Voltage cables
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
241 Overhead Pathway MV
242 Underground Pathway MV
243 Submersible Pathway MV

Asset_Type_Structure_Line_Electric_Medium_Voltage_Conduit

The Asset Types for the Electric Medium Voltage Conduit
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
112 Conduit MV

Asset_Type_Structure_Line_Electric_Station

The Asset Types for the Electric Station outlines
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
141 Station Fence
142 Station Gate

Asset_Type_Structure_Line_Ground

Asset Types for Ground Cables
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
801 Bare Ground
802 Covered Ground

Asset_Type_Structure_Line_Linear_Marker

Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
462 Buried Cable Marker
465 Covered Marker
466 Terrain Marker

Asset_Type_Structure_Line_Static_Wire

Static Wire modeled in the structure network
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
860 Double
861 Single

Asset_Type_Structure_Line_Tunnel

Lines used to represent access tunnels in the Structure Network
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
221 Tunnel

Asset_Type_Structure_Line_Wire_Aerial_Support

Lines used to represent aerial supports in the Structure Network
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
121 Bridge Suspension
122 Other Suspension
123 Spanguy
125 Aerial Span
126 Communications Support Guy
127 Lashing Guy
128 Guy Wire

Asset_Type_Structure_Line_Wire_Casing

Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
11 Casing

Asset_Type_Structure_Line_Wire_Duct_Bank

Lines used to represent duct banks in the Structure Network
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
81 Duct Bank

Asset_Type_Structure_Line_Wire_Microduct_Pathway

Asset Types for Microduct Casings
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
85 Single Microduct Casing
86 Multiple Microduct Casing

Asset_Type_Structure_Line_Wire_Trench

Lines used to represent trenches in the Structure Network
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
101 Trench

BooleanSymbolValue

Valid values are Yes and No.
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
1 Yes
0 No

Communications_Conduit_Type

The type of conduit
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
101 Abandoned Electric Conduit
102 Abandoned Gas Pipe
103 Abandoned Water Main
104 Sewer pipe
105 Storm Pipe
106 Abandoned Communication Conduit

Communications_Wireless_Tower_Type

General construction type of tower
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Monopole
2 Guyed
3 Lattice
4 Roof Top
5 Stealth
6 In Building

Construction_Status

Valid Construction statues for the assets
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Warehouse
1 Abandoned
2 Removed
3 Design
4 Approved
5 Under construction
6 Construction complete
7 Maintenance

Electric_BIL_Combined

BIL or Withstand Voltage Rating
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1200 1.2 kV
2500 2.5 kV
5000 5 kV
8700 8.7 kV
15000 15 kV
23000 23 kV
30000 30 kV
34500 34.5 kV
45000 45 kV
46000 46 kV
60000 60 kV
69000 69 kV
75000 75 kV
95000 95 kV
110000 110 kV
150000 150 kV
200000 200 kV
250000 250 kV
350000 350 kV

Electric_Buck_Boost_Rate

Valid Buck and Boost Rates
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
-10 10

Electric_Busbar_Material

List of valid Busbar Common Conductor Material
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
401 Solid Aluminium
402 Solid Copper
403 Solid Steel

Electric_Cable_Hardware_Type

Types of cable hardward
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
1 Brace
2 Suspension
3 Line Post

Electric_Capacitory_Type

Type of Capacitor
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 kVA-PF
2 AMP-PF
3 kW-kVAR

Electric_Capacitor_Line_Configuration

Capacitor line grounding configuration
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Delta - Inside Fuse
2 Delta - Outside Fuse
3 Delta - Unfused
4 Wye

Electric_Closing_Mode

Device Closing Mode
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Normal Reclose
2 Remote Block

Electric_Combined_Conductor_Material

Desc
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 #1 ACSR
2 #1 AL
3 #1 B.STRD
4 #1 CU
5 #1 WP
6 #2 PID AL
7 #2 3/4 AWAC
8 #2 4/3 AWAC
9 #2 5/2 AWAC
10 #2 5005
11 #2 AAAC
12 #2 AAC
13 #2 AACTW
14 #2 ACAR
15 #2 ACSR
17 #2 ACSR/SD
18 #2 ACSRTW
19 #2 AER.CAB
20 #2 AL
21 #2 AWA
22 #2 AWAC
23 #2 B.SOL
24 #2 B.STRD
25 #2 CU
26 #2 CU PILC
27 #2 HD
28 #2 PECN
29 #2 PECN AL
30 #2 PECN CU
31 #2 PECN-PEJ AL
32 #2 PECN-PEJ PID
33 #2 PECN-PEJ PID AL
34 #2 PECN-PID AL
36 #2 PID CU
37 #2 PID-PEJ AL
38 #2 PILC
39 #2 PILC NJ CU
40 #2 PILC-NJ
41 #2 PILC-PEJ
42 #2 PILC-PEJ CU
43 #2 SOL
44 #2 SOL PECN-PEJ AL
45 #2 SOL TRXLPECN-PEJ AL PID
46 #2 SOL XLPECN-PEJ
47 #2 THW
48 #2 TREE
49 #2 TRXLPECN-PEJ AL PID
50 #2 WP
51 #2 WPAL
52 #2 WPCU
53 #2 XLPECN AL
54 #2 XLPECN-PEJ
55 #2 XLPECN-PEJ AL
56 #2 XLPE-PEJ AL
57 #2/7 TREE
58 #2SOL TRXLPECN-PEJ AL PID
59 #4 5005
60 #4 ACSR
61 #4 ACSRTW
62 #4 AL
63 #4 B.SOL
64 #4 B.STRD
65 #4 CU
66 #4 GAL
67 #4 HD
68 #4 LEAD
69 #4 NEOPRENE
70 #4 PAA
71 #4 PECN
72 #4 PECN CU
73 #4 PELPE CU
74 #4 PID CU
75 #4 PILC
76 #4 PILC-NJ
77 #4 PILC-PEJ CU
78 #4 THW
79 #4 TREE
80 #4 WP
81 #4 WPAL
82 #4 WPCU
83 #4A CUWELD
84 #4D CUWELD
85 #4N CUWELD
86 #6 AL
87 #6 B.SOL
88 #6 B.STRD
89 #6 CU
90 #6 CUWELD
91 #6 CW
92 #6 GAL
93 #6 HD
94 #6 LEAD
95 #6 PILC
96 #6 PILC-PEJ CU
97 #6 SOLID
98 #6 THW
99 #6 TREE
100 #6 WP
101 #6 WPAL
102 #6 WPCU
103 #6A CUWELD
104 #8 AL
105 #8 B.STRD
106 #8 CU
107 #8 CUWELD
108 #8 HD
109 #8 SOL
110 #8 WP
111 #8 WPCU
112 #8A CUWELD
113 1 ACSR
114 1 ACSRTW
115 1/0 15kV SpacerCable
116 1/0 4/3 AWAC
117 1/0 5005
118 1/0 AAAC
119 1/0 AAC
120 1/0 ACAR
121 1/0 ACSR
122 1/0 ACSRTW
123 1/0 AER.CAB
124 1/0 AL
125 1/0 ALUMOWELD
126 1/0 AWA
127 1/0 B.STRD
128 1/0 CU
129 1/0 LEAD
130 1/0 OTH
131 1/0 PAA
132 1/0 PILC
133 1/0 PILC-NJ
134 1/0 STEEL
135 1/0 THW
136 1/0 TREE
137 1/0 WP
138 1/0 WPAL
139 1/0 WPCU
140 1000 PECN AL
141 1000 PECN-PEJ AL
142 1000 PILC-PEJ CU
143 1000 TRXLPECN-PEJ CU
144 1000 XLPE AL
145 1000 XLPECN AL
146 1000 XLPECN-PEJ
147 1000 XLPECN-PEJ AL
148 1000 XLPE-PEJ AL
149 1033 ACSR
150 1033 AL
151 1250 RUBBER
152 2/0 AAAC
153 2/0 ACSR
154 2/0 ACSRTW
155 2/0 AL
156 2/0 B.STRD
157 2/0 CU
158 2/0 PECN AL
159 2/0 PECN-PEJ AL
160 2/0 PILC
161 2/0 WP
162 2/0 WPAL
163 2/0 WPCU
164 2/0 XLPE AL
165 2/0 XLPECN-PEJ
166 2/0 XLPECN-PEJ AL
167 2/0 XLPE-PEJ AL
168 250 AAC
169 250 AL
170 250 B.STRD
171 250 CU
172 3 ACSR
173 3 AL
174 3 CU
175 3 WPCU
176 3/0 5/2 AWAC
177 3/0 5005
178 3/0 ACSR
179 3/0 AL
180 3/0 B.STRD
181 3/0 CU
182 3/0 WP
183 336 AAC
184 336 AACTW
185 336 ACAR
186 336 ACSR
187 336 ACSRTW
188 336 AL
189 336 CU
190 336 WPAL
191 336.4 ACSR
192 336.4 PAA
193 350 EPR-PEJ CU
194 350 PECN AL
195 350 PECN-PEJ AL
196 350 XLPE AL
197 350 XLPECN-PEJ
198 350 XLPECN-PEJ AL
199 355 ACAR
200 394.5 5005
201 394.5 BNDL 5005
202 395 AAAC
203 395 ACAR
204 395 ACSR
205 395 AL
206 397 AAAC
207 397 AAC
208 397 ACAR
209 397 ACSR
210 397 ACSRTW
211 397 AL
212 397 AWA
213 397 CU
214 4/0 AAAC
215 4/0 AAC
216 4/0 ACSR
217 4/0 ACSR2
218 4/0 ACSRTW
219 4/0 AER.CAB
220 4/0 AL
221 4/0 B.STRD
222 4/0 BNDL B.STRD
223 4/0 CU
224 4/0 PECN CU
225 4/0 PILC
226 4/0 PILC-PEJ CU
227 4/0 THW
228 4/0 TREE
229 4/0 WP
230 4/0 WPAL
231 4/0 WPCU
232 400K B.STRD
233 500 AL
234 500 CU
235 500 EPR-PEJ CU
236 500 PECN
237 500 PECN CU
238 500 PECN-PEJ CU
239 500 PILC
240 500 PILC-NJ
241 500 PILC-PEJ
242 500 PILC-PEJ CU
243 500 THW
244 500 XLPECN-PEJ
245 500K B.STRD
246 636 AAC
247 636 ACAR
248 636 ACSR
249 636 ACSRTW
250 636 AL
251 636 B.STRD
252 636 CU
253 750 AAAC
254 750 AAC
255 750 ACSR
256 750 AL
257 750 AWA
258 750 B.STRD
259 750 CU
260 750 EPR-PEJ
261 750 EPR-PEJ CU
262 750 PECN-PEJ AL
263 750 XLPE AL
264 750 XLPECN-PEJ
265 750 XLPECN-PEJ AL
266 750 XLPE-PEJ AL
267 795 AAAC
268 795 AAC
269 795 ACSR
270 795 AL
401 Solid Aluminum
402 Solid Copper
403 Solic Steel
1000 Single
1001 Duplex
1002 Triplex
1003 Quadraplex
2001 ACSR
2002 AAAC

ELectric_Combined_Maximumm_Operating_Voltage_LL

Combined list of maximum operating voltages
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
600 600 V
1200 1.2 kV
7200 7.2 kV
12000 12 kV
24000 24 kV
28000 28 kV
36000 36 kV
44000 44 kV
64000 64 kV
72500 72.5 kV
96000 96 kV
100000 100 kV
121000 121 kV
124000 124 kV
145000 145 kV
172000 172 kV
245000 245 kV
420000 420 kV

Electric_Combined_Maximum_Voltage

Combined Maximum Voltage Values
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
229 229 V
240 240 V
253 253 V
264 264 V
440 440 V
480 480 V
528 528 V
660 660 V
759 759 V
1100 1.1 kV
8000 8 kV
15000 15 kV
25000 25 kV
35000 35 kV
52000 52 kV
72500 72.5 kV
120000 120 kV
145000 145 kV
170000 170 kV
240000 240 kV
300000 300 kV
362000 362 kV
420000 420 kV
550000 550 kV
800000 800 kV
1100000 1.1 MV
1200000 1.2 MV

Electric_Combined_Nominal_Voltage_LG

Combined Line to Ground Nominal Voltages
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
120 120 V
230 230 V
277 277 V
400 400 V
2400 2.4 kV
4800 4.8 kV
6930 6.93 kV
7200 7.2 kV
7620 7.62 kV
7970 7.97 kV
12000 12 kV
13200 13.2 kV
14400 14.4 kV
19920 19.92 kV

Electric_Combined_Nominal_Voltage_LL

Combined Line to Line Nominal Voltages
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
208 208 V
240 240 V
253 253 V
400 400 V
480 480 V
528 528 V
600 600 V
690 690 V
1000 1000 V
2400 2.4 kV
4160 4.16 kV
4800 4.8 kV
6900 6.9 kV
6930 6.93 kV
7200 7.2 kV
7620 7.62 kV
7970 7.97 kV
8320 8.32 kV
11000 11 kV
12000 12 kV
12470 12.47 kV
13200 13.2 kV
13800 13.8 kV
14400 14.4 kV
15000 15 kV
18000 18 kV
19920 19.92 kV
20780 20.78 kV
22860 22.86 kV
23000 23 kV
24940 24.94 kV
34500 34.5 kV
46000 46 kV
50000 50 kV
60000 60 kV
69000 69 kV
70000 70 kV
75000 75 kV
80000 80 kV
100000 100 kV
115000 115 kV
120000 120 kV
138000 138 kV
145000 145 kV
150000 150 kV
161000 161 kV
180000 180 kV
200000 200 kV
230000 230 kV
250000 250 kV
266000 266 kV
270000 270 kV
285000 285 kV
320000 320 kV
345000 345 kV
350000 350 kV
362000 362 kV
400000 400 kV
440000 440 kV
500000 500 kV
515000 515 kV
525000 525 kV
533000 533 kV
600000 600 kV
765000 765 kV
800000 800 kV
1000000 1 MV
1100000 1.1 MV
1200000 1.2 MV
1400000 1.4 MV
1500000 1.5 MV
1800000 1.8 MV
2500000 2.5 MV
3000000 3 MV
4000000 4 MV
5000000 5 MV
6000000 6 MV
6400000 6.4 MV
7200000 7.2 MV
8000000 8 MV
10000000 10 MV
12000000 12 MV

Electric_Configuration_Type

How equiment is configuration, in Series or Shunt
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Shunt
2 Series

Electric_Connector_Material

List of valid Connector Common Conductor Material
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1001 ACSR
1002 ACSR/AW
1003 ACSR/TW
1004 ACSS/AW
1005 ACSS/TW
1006 AAC
1007 AAC/TW
1008 AAAC
1009 ACAR
1010 Welded Aluminum Sheath
1011 Copper Wires with Aluminum Sheath
1012 Copper Wires with Copper Sheath
1013 Copper Wires with Lead Sheath

Electric_DC_Low_Voltage_Nominal_Voltage

DC Nominal Low Voltage
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
12 12 V
24 24 V
36 36 V
48 48 V
60 60 V
68 68 V
72 72 V
110 110 V
120 120 V
125 125 V
160 160 V
380 380 V
500 500 V
575 575 V
600 600 V
750 750 V
1000 1000 V
1500 1500 V
400 400 V
690 690 V

Electric_Device_OperatingMechanism

Valid combinationsfor Operating Mechanism
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Bell Crank
2 Control Rod
4 Hook stick
5 Bell Crank and Hook Stick
6 Control Rod and Hook Stick
8 Remote
9 Bell Crank and Remote
10 Control Rod and Remote
12 Hook Stick and Remote
13 Bell Crank, Hook Stick and Remote
14 Control Rod, Hook Stick and Remote

Electric_Device_Operation

Valid values for Operation Type
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Gang Operated
2 Phase Operable
3 Gang and Phase Operable

Electric_Device_Resistance_Range

Range of valid resistance values
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 999999

Electric_Device_Switch_Manufacturer

All Electric Device Switch Manufacturer
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 ABB/Westinghouse
16 G&W Electric
17 General Electric
44 Royal Switchgear Mfg Co Inc
45 S&C
62 McGraw Edison
71 AB Chance
72 ABB T&D
73 Cooper
74 Eisler Engineering
75 Elastimold
76 Hi-Tech Fuses
77 Kearney
88 RTE
94 Southern State Equipment
105 USCO Power Equipment
108 Wagner

Electric_Discharge_Current

High Voltage Discharge Current
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
500 .5 kA
1000 1 kA
1500 1.5 kA
2000 2 kA
3000 3 kA
5000 5 kA
10000 10 kA
15000 15 kA
20000 20 kA
40000 40 kA

Electric_Equipment_Manufacturer

All Electric Equipment Manufacturer
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 ABB/Westinghouse
2 American Electric Lighting
3 Beckwith Electric Company
4 Canada Power Products
5 Carte International
6 Central Moloney Inc
7 Challenger Electrical Equip CO
8 Chardon Group
9 Cooper Industries/Eaton
10 Dowzer/Hevi Duty
11 ERICO
12 ERM Co
13 ESCO Transformer Co
14 Fargo Electric
15 Farranti-Packard Transformer
16 G&W Electric
17 General Electric
18 Glavan Electric
19 Gordon Electric
20 Gould Shawmut
21 Howard Industries
22 Hubbell
23 Inertia Engineering & Machine Works
24 ITT Bell and Gossett
25 Jimelco
26 Johnson Electric
27 Kaiser
28 Lindsey USA
29 LittelFuse
30 Magnetic Electric Co
31 Meramac
32 Mersen
33 MGM Transformer Company
34 Mid Central Electric
35 Nova
36 Pacific Air Switch Corp
37 Pauwels
38 Pennsylvania Transformer CO
39 Philips
40 Pole Star
41 Power Delivery Products
42 Power Partners
43 Preformed Line Products
44 Royal Switchgear Mfg Co Inc
45 S&C
46 Sangamo
47 Schneider Electric
48 Schwager Wood
49 Schweitzer
50 Siemens
51 Shallbetter
52 Sola Hevi-Duty
53 Sylvania
54 T&R Electric
55 TYCO
56 Uptegraff
57 Van Tran Transformers
9999 Other

Electric_Fuel_Type

Generator Fuel Type
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Ethenaol
2 Gasoline
3 Hydrogen
4 Natural Gas
5 Hydro

Electric_Generation_ANSI_Group_Code

ANSI Generation Group Code
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
2 Group 2
3 Group 3
4 Group 4
5 Group 5

Electric_Generation_CO2

Generation CO2 output in ppm
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 10000000

Electric_Generation_NOx

Generation NOx output in ppm
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 1000000

Electric_Generation_Pole_Count

Generator Pole count
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
2 2 Pole
4 4 Pole
6 6 Pole
8 8 Pole
10 10 Pole
12 12 Pole
14 14 Pole
16 16 Pole
18 18 Pole
20 20 Pole
40 40 Pole

Electric_Generation_SO2

Generation SO2 output in ppm
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 10000000

Electric_Generation_Start_Time

Generation Station Start time
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Min Max
0 0

Electric_Generator_Control_Type

Generator Control Type
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Fixed
2 Voltage
3 Swing

Electric_Grid_Level

Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Transmission
2 Main Subtransmission
3 Subra-Regional Transmission
5 Regional Distribution
6 Transformer Substation
7 Low Voltage Grid

Electric_Ground_Configuration

List of valid ground types for the distribution system
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Grounded Wye
2 Wye
3 Delta
4 Grounded Delta
5 Direct Current

Electric_Ground_Configuration_Transformer_Regulator

Grounding type for transformers and regulators
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Grounded Wye
2 Wye
3 Delta
4 Direct Current

Electric_Ground_Material

Grounding material
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
515 Aluminum
525 Copper

Electric_Ground_Type

Ground Type
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Bound
2 Mesh
3 Rod

Electric_High_Voltage_Arrester_Design

High Voltage Arrester Design
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Intermediate
3 Station
4 Dual Rated Station

Electric_High_Voltage_Conductor_Material

List of valid High Voltage Conductor Common Conductor Material
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1001 ACSR
1002 ACSR/AW
1003 ACSR/TW
1004 ACSS/AW
1005 ACSS/TW
1006 AAC
1007 AAC/TW
1008 AAAC
1009 ACAR
1010 Welded Aluminum Sheath
1011 Copper Wires with Aluminum Sheath
1012 Copper Wires with Copper Sheath
1013 Copper Wires with Lead Sheath

Electric_High_Voltage_DC_Voltage

Valid High Voltage Direct Current Voltages
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
18000 18 kV
50000 50 kV
60000 60 kV
70000 70 kV
75000 75 kV
80000 80 kV
100000 100 kV
150000 150 kV
180000 180 kV
200000 200 kV
250000 250 kV
266000 266 kV
270000 270 kV
285000 285 kV
320000 320 kV
350000 350 kV
400000 400 kV
440000 440 kV
500000 500 kV
515000 515 kV
525000 525 kV
533000 533 kV
600000 600 kV
1000000 1000 kV
1100000 1100 kV
1200000 1200 kV
1400000 1400 kV
1500000 1500 kV
1800000 1800 kV
2500000 2500 kV
3000000 3000 kV
4000000 4000 kV
5000000 5000 kV
6000000 6000 kV
6400000 6400 kV
7200000 7200 kV
8000000 8000 kV
10000000 10000 kV
12000000 12000 kV

Electric_High_Voltage_Generate_Watts

Maximum Generation Station Watts output
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
-1 Idle
0 Unknown
540 540 MW
1540 1540 MW

Electric_High_Voltage_Impulse

Maximum Impluse current for High Voltage
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Min Max
10 10000

Electric_High_Voltage_KVAR

Domain for valid kVAR rating for High Voltage Capacitors
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
50000 50 kvar
100000 100 kvar
150000 150 kvar
200000 200 kvar
300000 300 kvar
400000 400 kvar
600000 600 kvar

Electric_High_Voltage_Load_Loss

Valid Load Loss Range for High Voltage
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Min Max
0 1000

Electric_High_Voltage_Load_Watts

Maximum Load in Watts
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Min Max
0 20000000

ELectric_High_Voltage_Maximumm_Operating_Voltage_LL

List of High Voltage maximum voltages
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
100000 100 kV
121000 121 kV
124000 124 kV
145000 145 kV
172000 172 kV
245000 245 kV
420000 420 kV

Electric_High_Voltage_Maximum_Continuous_Current

List of valid High Voltage Switching and Protective Maximum Continuous Current
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
600 600 A
1200 1200 A
1600 1600 A
2000 2000 A
3000 3000 A
6000 6000 A

Electric_High_Voltage_Maximum_Current

Maximum Current Range Domain
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Min Max
0 15000

Electric_High_Voltage_Maximum_Emergency_Current

Maximum Emergency Current
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Min Max
0 12000

Electric_High_Voltage_Maximum_Interrupting_Current

List of valid High Voltage Switching and Protective Maximum Interrupting Current
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
31500 31.5 kA
40000 40 kA
60000 60 kA
80000 80 kA
90000 90 kA
2000 2 kA

Electric_High_Voltage_Maximum_Voltage

The maximum voltage, in kV
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
120000 120 kV
145000 145 kV
170000 170 kV
240000 240 kV
300000 300 kV
362000 362 kV
420000 420 kV
550000 550 kV
800000 800 kV
1100000 1100 kV
1200000 1200 kV

Electric_High_Voltage_Nominal_Voltage

List of valid nominal voltages for high voltage
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
115000 115 kV
138000 138 kV
161000 161 kV
230000 230 kV
345000 345 kV
500000 500 kV
765000 765 kV
18000 18 kV
50000 50 kV
60000 60 kV
70000 70 kV
75000 75 kV
80000 80 kV
100000 100 kV
150000 150 kV
180000 180 kV
200000 200 kV
250000 250 kV
266000 266 kV
277000 277 kV
285000 285 kV
320000 320 kV
350000 350 kV
400000 400 kV
440000 440 kV
515000 515 kV
525000 525 kV
533000 533 kV
600000 600 kV
1000000 1 MV
1100000 1.1 MV
1200000 1.2 MV
1400000 1.4 MV
1500000 1.5 MV
1800000 1.8 MV
2500000 2.5 MV
3000000 3 MV
4000000 4 MV
5000000 5 MV
6000000 6 MV
6400000 6.4 MV
7200000 7.2 MV
8000000 8 MV
10000000 10 MV
12000000 12 MV

Electric_High_Voltage_Number_of_Phases

List of valid phase identifiers for the transmission system
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
2 Two Phase
3 Three Phase
6 Six Phase

Electric_High_Voltage_Phases_Constructed

High Voltage number of Phase Constructed
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
2 Two Phase
3 Three Phase
6 Six Phase
12 Twelve Phase

Electric_High_Voltage_Phase_Attribution

List of valid phase identifiers for the transmission system
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 De-Energized
1 III
2 II
3 II,III
4 I
5 I,III
6 I,II
7 I,II,III

Electric_High_Voltage_Pole_Depth

Depth of Pole in ground
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 20

Electric_High_Voltage_Pole_Height

Height of Pole
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
55 55 Feet
60 60 Feet
65 65 Feet
70 70 Feet
75 75 Feet
80 80 Feet
85 85 Feet
90 90 Feet
95 95 Feet
100 100 Feet
105 105 Feet
110 110 Feet
115 115 Feet
120 120 Feet
125 125 Feet

Electric_High_Voltage_Pole_Height_metric

High Voltage Height of Pole in Metric
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
60 6 Meter
65 6.5 Meter
70 7 Meter
75 7.5 Meter
80 8 Meter
85 8.5 Meter
90 9 Meter
95 9.5 Meter
100 10 Meter
105 10.5 Meter
110 11 Meter
115 11.5 Meter
120 12 Meter
125 12.5 Meter
130 13 Meter
135 13.5 Meter
140 14 Meter
145 14.5 Meter
150 15 Meter
160 16 Meter
170 17 Meter
180 18 Meter
190 19 Meter
200 20 Meter
220 22 Meter
240 24 Meter
260 26 Meter
280 28 Meter
300 30 Meter

Electric_High_Voltage_Regulator_VA

List of valid High Voltage Regulator in volt amps
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
500000 .5 MVA
1000000 1 MVA
1500000 1.5 MVA
2000000 2 MVA
2500000 2.5 MVA
3000000 3 MVA
3500000 3.5 MVA
4000000 4 MVA

Electric_High_Voltage_Service_Load_kW

Range domain of valid kW loads
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Min Max
0 500000

Electric_High_Voltage_Switch_Continuous_Amps

High Voltage Switch Continuous Amps
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
600 .6 kA
1200 1.2 kA
1250 1.25 kA
1600 1.6 kA
2000 2 kA
2500 2.5 kA
3000 3 kA

Electric_High_Voltage_Switch_Interrupting_Amps

High Voltage Switch Interrupting Current
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1600 1.6 kA
31500 31.5 kA
40000 40 kA
50000 50 kA
63000 63 kA
25000 25 kA
29000 29 kA

Electric_High_Voltage_Transformer_VA

List of valid High Voltage Transformer Power Rating
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
5500000 5.5 MVA
74000000 74 MVA
75000000 75 MVA
200000000 200 MVA
300000000 300 MVA
350000000 350 MVA
400000000 400 MVA
500000000 500 MVA
550000000 550 MVA
650000000 650 MVA
750000000 750 MVA
1000000000 1000 MVA
1200000000 1200 MVA
1500000000 1500 MVA
10000000 100 MVA
20000000 200 MVA
30000000 300 MVA
35000000 350 MVA
40000000 400 MVA
50000000 500 MVA
55000000 550 MVA
65000000 650 MVA
100000000 1000 MVA
120000000 1200 MVA
150000000 1500 MVA

Electric_Hour

Hour of Operation
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Min Max
1 24

Electric_Impedance_Range

Valid Impendance Range
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 5000

Electric_Light_Housing_Type

Light Housing Type
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Cobra Head
2 Security
3 Roadway
4 Flood

Electric_Load_Tap_Bandwidth

Valid Load Tap Bandwidth
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 10

Electric_Low_Nominal_Voltage_LG

Low Voltage Line to Ground Nominal Operating Voltage
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
120 120 V
125 125 V
230 230 V
277 277 V
400 400 V

Electric_Low_Voltage_Arrester_Design

Low Voltage Arrester Design
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Load Break
2 Surge
3 Station

Electric_Low_Voltage_Circuit_Breaker_Continuous_Amps

Low Voltage Circuit Breaker Continuous Amps
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
15 15 A
20 20 A
30 30 A
100 100 A
200 200 A
600 600 A
800 800 A
1200 1200 A

Electric_Low_Voltage_Circuit_Breaker_Interrupting_Amps

Low Voltage Interrupting Amps
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
10000 10 kA

Electric_Low_Voltage_Conductor_Material

Low Voltage conductor type
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
999 Other
1001 ACSR
1002 ACSR/AW
1003 ACSR/TW
1006 AAC
1009 ACAR
2001 Duplex
2002 Triplex
2003 Quadraplex

Electric_Low_Voltage_Fuse_Continuous_Amps

List of valid continuous amps for a fuse
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
3 3 A
7 7 A
10 10 A
15 15 A
20 20 A
25 25 A
30 30 A
40 40 A
50 50 A
100 100 A
200 200 A

Electric_Low_Voltage_Fuse_Interrupting_Amps

List of valid interrupting amps for a fuse
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
30 30 A
60 60 A
100 100 A
200 200 A
1000 1000 A
Types of fuse links
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
10 K
11 T
12 MS
13 QH
14 Standard
15 SloFast

Electric_Low_Voltage_Fuse_Type

List of valid fuse types
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
17 Kearney A
18 Kearney B

Electric_Low_Voltage_KVAR

Domain fo rvalid kVAR rating for Low Voltage Capacitors
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
25000 25 kvar
50000 50 kvar
75000 75 kvar
100000 100 kvar
125000 125 kvar
150000 150 kvar
175000 175 kvar
200000 200 kvar
225000 225 kvar
250000 250 kvar

Electric_Low_Voltage_Load_Loss

Valid Load Loss Range for Low Voltage
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Min Max
0 100

Electric_Low_Voltage_Load_Watts

Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Min Max
0 20000

ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL

List of Low Voltage maximum voltages
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
600 600 V

Electric_Low_Voltage_Maximum_Continuous_Current

Low Voltage Maximum Continuous current in amps
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
250 250 A
300 300 A
600 600 A

Electric_Low_Voltage_Maximum_Emergency_Current

Low Voltage Maximum Emergency current in amps
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Min Max
0 3000

Electric_Low_Voltage_Maximum_Voltage

Low Voltage maximum voltage
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
229 229 V
253 253 V
264 264 V
440 440 V
528 528 V
660 660 V
759 759 V
1100 1.1 kV
480 480 V
240 240 V

Electric_Low_Voltage_Nominal_Voltage

Low Voltage Line to Line Nominal Operating Voltage
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
208 208 V
240 240 V
480 480 V
600 600 V
400 400 V
216 216 V
12 12 V
24 24 V
48 48 V
96 96 V

Electric_Low_Voltage_Phase_Attribution

Low Voltage Phase labels
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 De-Energized
1 c
2 b
3 bc
4 a
5 ac
6 ab
7 abc

Electric_Low_Voltage_Phase_Substitution

Phase Substitution Values for Low Voltage
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 abc->000
4 abc->00a
2 abc->00b
1 abc->00c
32 abc->0a0
36 abc->0aa
34 abc->0ab
33 abc->0ac
16 abc->0b0
20 abc->0ba
18 abc->0bb
17 abc->0bc
8 abc->0c0
12 abc->0ca
10 abc->0cb
9 abc->0cc
256 abc->a00
260 abc->a0a
258 abc->a0b
257 abc->a0c
288 abc->aa0
292 abc->aaa
290 abc->aab
289 abc->aac
272 abc->ab0
276 abc->aba
274 abc->abb
273 abc->abc
264 abc->ac0
268 abc->aca
266 abc->acb
265 abc->acc
128 abc->b00
132 abc->b0a
130 abc->b0b
129 abc->b0c
160 abc->ba0
164 abc->baa
162 abc->bab
161 abc->bac
144 abc->bb0
148 abc->bba
146 abc->bbb
145 abc->bbc
136 abc->bc0
140 abc->bca
138 abc->bcb
137 abc->bcc
64 abc->c00
68 abc->c0a
66 abc->c0b
65 abc->c0c
96 abc->ca0
100 abc->caa
98 abc->cab
97 abc->cac
80 abc->cb0
84 abc->cba
82 abc->cbb
81 abc->cbc
72 abc->cc0
76 abc->cca
74 abc->ccb
73 abc->ccc

Electric_Low_Voltage_Pole_Height

Low Voltage Pole Heights
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
20 20 Feet
25 25 Feet
30 30 Feet
35 35 Feet
40 40 Feet
45 45 Feet
50 50 Feet
55 55 Feet
60 60 Feet
65 65 Feet
70 70 Feet
75 75 Feet
80 80 Feet
85 85 Feet
90 90 Feet
95 95 Feet

Electric_Low_Voltage_Pole_Height_metric

Low Voltage Pole Heights in Metric
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
60 6 Meter
65 6.5 Meter
70 7 Meter
75 7.5 Meter
80 8 Meter
85 8.5 Meter
90 9 Meter
95 9.5 Meter
100 10 Meter
105 10.5 Meter
110 11 Meter
115 11.5 Meter
120 12 Meter
125 12.5 Meter
130 13 Meter
135 13.5 Meter
140 14 Meter
145 14.5 Meter
150 15 Meter
160 16 Meter
170 17 Meter
180 18 Meter
190 19 Meter
200 20 Meter
220 22 Meter
240 24 Meter
260 26 Meter
280 28 Meter
300 30 Meter

Electric_Low_Voltage_Regulator_VA

Low Voltage Regulators Volt Amps
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
600 600 VA
1200 1200 VA

Electric_Low_Voltage_Street_Bulb_Type

List of valid bulb types for streetlights
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
30 High Pressure Sodium (HPS)
31 Low Pressure Sodium (LPS)
32 Metal Halide (MH)
33 Mercury Vapor (MV)
34 Halogen (HG)
35 Light Emitting Diode (LED)
36 Phosphor-Converted Amber LED (PCA)
37 Narrow-Band Amber LED (NBA)

Electric_Low_Voltage_Switch_Continuous_Amps

Low Voltage Switch Continuous Amps
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
15 15 A
20 20 A
30 30 A
45 45 A
50 50 A
60 60 A
100 100 A
125 125 A
200 200 A
225 225 A
300 300 A
320 320 A
800 800 A
1200 1200 A
2500 2500 A

Electric_Low_Voltage_Switch_Interrupting_Amps

Low Voltage Switch Interrupting Amps
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
10000 10 kA

Electric_Low_Voltage_Transformer_VA

Low Voltage Transformer kVA
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
500 0.5 kVA
750 0.75 kVA
1000 1 kVA
1500 1.5 kVA
2000 2 kVA
3000 3 kVA
5000 5 kVA
7500 7.5 kVA
10000 10 kVA
15000 15 kVA
25000 25 kVA

Electric_Maximum_Voltage_Change

Maximum Voltage Change
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Min Max
0 10000

Electric_Medium_Low_Voltage_Number_Of_Phases

Low Voltage number of phases constructed
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Single Phase
2 Two Phase
3 Three Phase

Electric_Medium_Nominal_Voltage_LG

Medium Voltage Line to Ground Nominal Operating Voltage
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
2400 2.4 kV
4800 4.8 kV
6930 6.93 kV
7200 7.2 kV
7620 7.62 kV
7970 7.97 kV
12000 12 kV
13200 13.2 kV
14400 14.4 kV
19920 19.92 kV

Electric_Medium_Voltage_Arrester_Design

Medium Voltage Arrester Design
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Load Break
2 Surge
3 Station

Electric_Medium_Voltage_Circuit_Breaker_Continuous_Amps

Medium Voltage Circuit Breaker Continuous Amps Ratings
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
200 200 A
600 600 A
1250 1250 A
1600 1600 A
2000 2000 A
2500 2500 A
3000 3000 A

Electric_Medium_Voltage_Circuit_Breaker_Interrupting_Amps

Medium Voltage Circuit Breaker Interrupting Amps
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
16000 16 kA
25000 25 kA
29000 29 kA
31500 31.5 kA
40000 40 kA
50000 50 kA
63000 63 kA

Electric_Medium_Voltage_Conductor_Material

List of valid medium voltage conductor materials for the distribution system
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 #1 ACSR
2 #1 AL
3 #1 B.STRD
4 #1 CU
5 #1 WP
6 #2 PID AL
7 #2 3/4 AWAC
8 #2 4/3 AWAC
9 #2 5/2 AWAC
10 #2 5005
11 #2 AAAC
12 #2 AAC
13 #2 AACTW
14 #2 ACAR
15 #2 ACSR
17 #2 ACSR/SD
18 #2 ACSRTW
19 #2 AER.CAB
20 #2 AL
21 #2 AWA
22 #2 AWAC
23 #2 B.SOL
24 #2 B.STRD
25 #2 CU
26 #2 CU PILC
27 #2 HD
28 #2 PECN
29 #2 PECN AL
30 #2 PECN CU
31 #2 PECN-PEJ AL
32 #2 PECN-PEJ PID
33 #2 PECN-PEJ PID AL
34 #2 PECN-PID AL
36 #2 PID CU
37 #2 PID-PEJ AL
38 #2 PILC
39 #2 PILC NJ CU
40 #2 PILC-NJ
41 #2 PILC-PEJ
42 #2 PILC-PEJ CU
43 #2 SOL
44 #2 SOL PECN-PEJ AL
45 #2 SOL TRXLPECN-PEJ AL PID
46 #2 SOL XLPECN-PEJ
47 #2 THW
48 #2 TREE
49 #2 TRXLPECN-PEJ AL PID
50 #2 WP
51 #2 WPAL
52 #2 WPCU
53 #2 XLPECN AL
54 #2 XLPECN-PEJ
55 #2 XLPECN-PEJ AL
56 #2 XLPE-PEJ AL
57 #2/7 TREE
58 #2SOL TRXLPECN-PEJ AL PID
59 #4 5005
60 #4 ACSR
61 #4 ACSRTW
62 #4 AL
63 #4 B.SOL
64 #4 B.STRD
65 #4 CU
66 #4 GAL
67 #4 HD
68 #4 LEAD
69 #4 NEOPRENE
70 #4 PAA
71 #4 PECN
72 #4 PECN CU
73 #4 PELPE CU
74 #4 PID CU
75 #4 PILC
76 #4 PILC-NJ
77 #4 PILC-PEJ CU
78 #4 THW
79 #4 TREE
80 #4 WP
81 #4 WPAL
82 #4 WPCU
83 #4A CUWELD
84 #4D CUWELD
85 #4N CUWELD
86 #6 AL
87 #6 B.SOL
88 #6 B.STRD
89 #6 CU
90 #6 CUWELD
91 #6 CW
92 #6 GAL
93 #6 HD
94 #6 LEAD
95 #6 PILC
96 #6 PILC-PEJ CU
97 #6 SOLID
98 #6 THW
99 #6 TREE
100 #6 WP
101 #6 WPAL
102 #6 WPCU
103 #6A CUWELD
104 #8 AL
105 #8 B.STRD
106 #8 CU
107 #8 CUWELD
108 #8 HD
109 #8 SOL
110 #8 WP
111 #8 WPCU
112 #8A CUWELD
113 1 ACSR
114 1 ACSRTW
115 1/0 15kV SpacerCable
116 1/0 4/3 AWAC
117 1/0 5005
118 1/0 AAAC
119 1/0 AAC
120 1/0 ACAR
121 1/0 ACSR
122 1/0 ACSRTW
123 1/0 AER.CAB
124 1/0 AL
125 1/0 ALUMOWELD
126 1/0 AWA
127 1/0 B.STRD
128 1/0 CU
129 1/0 LEAD
130 1/0 OTH
131 1/0 PAA
132 1/0 PILC
133 1/0 PILC-NJ
134 1/0 STEEL
135 1/0 THW
136 1/0 TREE
137 1/0 WP
138 1/0 WPAL
139 1/0 WPCU
140 1000 PECN AL
141 1000 PECN-PEJ AL
142 1000 PILC-PEJ CU
143 1000 TRXLPECN-PEJ CU
144 1000 XLPE AL
145 1000 XLPECN AL
146 1000 XLPECN-PEJ
147 1000 XLPECN-PEJ AL
148 1000 XLPE-PEJ AL
149 1033 ACSR
150 1033 AL
151 1250 RUBBER
152 2/0 AAAC
153 2/0 ACSR
154 2/0 ACSRTW
155 2/0 AL
156 2/0 B.STRD
157 2/0 CU
158 2/0 PECN AL
159 2/0 PECN-PEJ AL
160 2/0 PILC
161 2/0 WP
162 2/0 WPAL
163 2/0 WPCU
164 2/0 XLPE AL
165 2/0 XLPECN-PEJ
166 2/0 XLPECN-PEJ AL
167 2/0 XLPE-PEJ AL
168 250 AAC
169 250 AL
170 250 B.STRD
171 250 CU
172 3 ACSR
173 3 AL
174 3 CU
175 3 WPCU
176 3/0 5/2 AWAC
177 3/0 5005
178 3/0 ACSR
179 3/0 AL
180 3/0 B.STRD
181 3/0 CU
182 3/0 WP
183 336 AAC
184 336 AACTW
185 336 ACAR
186 336 ACSR
187 336 ACSRTW
188 336 AL
189 336 CU
190 336 WPAL
191 336.4 ACSR
192 336.4 PAA
193 350 EPR-PEJ CU
194 350 PECN AL
195 350 PECN-PEJ AL
196 350 XLPE AL
197 350 XLPECN-PEJ
198 350 XLPECN-PEJ AL
199 355 ACAR
200 394.5 5005
201 394.5 BNDL 5005
202 395 AAAC
203 395 ACAR
204 395 ACSR
205 395 AL
206 397 AAAC
207 397 AAC
208 397 ACAR
209 397 ACSR
210 397 ACSRTW
211 397 AL
212 397 AWA
213 397 CU
214 4/0 AAAC
215 4/0 AAC
216 4/0 ACSR
217 4/0 ACSR2
218 4/0 ACSRTW
219 4/0 AER.CAB
220 4/0 AL
221 4/0 B.STRD
222 4/0 BNDL B.STRD
223 4/0 CU
224 4/0 PECN CU
225 4/0 PILC
226 4/0 PILC-PEJ CU
227 4/0 THW
228 4/0 TREE
229 4/0 WP
230 4/0 WPAL
231 4/0 WPCU
232 400K B.STRD
233 500 AL
234 500 CU
235 500 EPR-PEJ CU
236 500 PECN
237 500 PECN CU
238 500 PECN-PEJ CU
239 500 PILC
240 500 PILC-NJ
241 500 PILC-PEJ
242 500 PILC-PEJ CU
243 500 THW
244 500 XLPECN-PEJ
245 500K B.STRD
246 636 AAC
247 636 ACAR
248 636 ACSR
249 636 ACSRTW
250 636 AL
251 636 B.STRD
252 636 CU
253 750 AAAC
254 750 AAC
255 750 ACSR
256 750 AL
257 750 AWA
258 750 B.STRD
259 750 CU
260 750 EPR-PEJ
261 750 EPR-PEJ CU
262 750 PECN-PEJ AL
263 750 XLPE AL
264 750 XLPECN-PEJ
265 750 XLPECN-PEJ AL
266 750 XLPE-PEJ AL
267 795 AAAC
268 795 AAC
269 795 ACSR
270 795 AL

Electric_Medium_Voltage_Fuse_Continuous_Amps

List of valid continuous amps for a fuse
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
3 3 A
7 7 A
10 10 A
15 15 A
20 20 A
25 25 A
30 30 A
40 40 A
50 50 A
65 65 A
80 80 A
100 100 A
125 125 A
150 150 A
175 175 A
180 180 A
200 200 A
225 225 A
250 250 A
300 300 A
350 350 A
400 400 A
450 450 A
500 500 A
550 550 A
600 600 A

Electric_Medium_Voltage_Fuse_Interrupting_Amps

List of valid interrupting amps for a fuse
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
250 250 A
500 500 A
600 600 A
1080 1080 A
8000 8000 A
10000 10000 A
12000 12000 A
16000 16000 A
20000 20000 A
40000 40000 A
60000 60000 A
80000 80000 A

Electric_Medium_Voltage_Fuse_Rating

List of valid Electric Medium Voltage Fuse Ratingsl
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 C
2 E
3 R
4 PT

Electric_Medium_Voltage_Fuse_Type

Medium Voltage fuse types
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Bridged
2 Burndy
3 Bussman
4 Cooper Elf
5 D & W
6 EJO-1
7 Fault Tamer
8 Kearney
9 Kearney 200
10 Kearney QA
11 RTE B
12 S & C
13 S & C SM-4
14 X-Limiter
15 NX
16 CL
17 Kearney A
18 Kearney B

Electric_Medium_Voltage_Generate_Watts

Medium Voltage Generation Watts
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
-1 Idle

Electric_Medium_Voltage_KVAR

Domain of valid kVAR ratings for Medium Voltage Capacitors
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
5000 5 kvar
10000 10 kvar
20000 20 kvar
30000 30 kvar
50000 50 kvar
100000 100 kvar
150000 150 kvar
200000 200 kvar
300000 300 kvar
400000 400 kvar
500000 500 kvar
600000 600 kvar
800000 800 kvar
1200000 1200 kvar
1500000 1500 kvar
1800000 1800 kvar
2400000 2400 kvar
3600000 3600 kvar
900000 900 kvar

Electric_Medium_Voltage_Load_Loss

Valid Load Loss Range for Medium Voltage
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Min Max
0 1000

Electric_Medium_Voltage_Load_Watts

Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Min Max
0 100000

ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL

List of Medium Voltage maximum voltages
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1200 1.2 kV
7200 7.2 kV
12000 12 kV
24000 24 kV
28000 28 kV
36000 36 kV
44000 44 kV
64000 64 kV
72500 72.5 kV
96000 96 kV

Electric_Medium_Voltage_Maximum_Continuous_Current

Medium Voltage maximum continuous current
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
250 250 A
300 300 A
350 350 A
400 400 A
450 450 A
900 900 A
1350 1350 A

Electric_Medium_Voltage_Maximum_Emergency_Current

Medium Voltage maximum emergency current
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Min Max
0 12000

Electric_Medium_Voltage_Maximum_Voltage

The maximum voltage, in kV
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
8000 8 kV
15000 15 kV
25000 25 kV
35000 35 kV
52000 52 kV
72500 72.5 kV

Electric_Medium_Voltage_Nominal_Voltage

List of valid nominal voltages for the distribution system
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
2400 2.4 kV
4160 4.16 kV
4800 4.8 kV
6900 6.9 kV
6930 6.93 kV
7200 7.2 kV
7620 7.62 kV
7970 7.97 kV
8320 8.32 kV
12000 12 kV
12470 12.47 kV
13200 13.2 kV
13800 13.8 kV
14400 14.4 kV
19920 19.92 kV
20780 20.78 kV
22860 22.86 kV
23000 23 kV
24940 24.94 kV
34500 34.5 kV
46000 46 kV
69000 69 kV

Electric_Medium_Voltage_Phase_Attribution

List of valid phase identifiers for the distribution system
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 De-Energized
1 C
2 B
3 BC
4 A
5 AC
6 AB
7 ABC

Electric_Medium_Voltage_Phase_Substitution

Phase Substitution Values for Medium Voltage
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 ABC->000
4 ABC->00A
2 ABC->00B
1 ABC->00C
32 ABC->0A0
36 ABC->0AA
34 ABC->0AB
33 ABC->0AC
16 ABC->0B0
20 ABC->0BA
18 ABC->0BB
17 ABC->0BC
8 ABC->0C0
12 ABC->0CA
10 ABC->0CB
9 ABC->0CC
256 ABC->A00
260 ABC->A0A
258 ABC->A0B
257 ABC->A0C
288 ABC->AA0
292 ABC->AAA
290 ABC->AAB
289 ABC->AAC
272 ABC->AB0
276 ABC->ABA
274 ABC->ABB
273 ABC->ABC
264 ABC->AC0
268 ABC->ACA
266 ABC->ACB
265 ABC->ACC
128 ABC->B00
132 ABC->B0A
130 ABC->B0B
129 ABC->B0C
160 ABC->BA0
164 ABC->BAA
162 ABC->BAB
161 ABC->BAC
144 ABC->BB0
148 ABC->BBA
146 ABC->BBB
145 ABC->BBC
136 ABC->BC0
140 ABC->BCA
138 ABC->BCB
137 ABC->BCC
64 ABC->C00
68 ABC->C0A
66 ABC->C0B
65 ABC->C0C
96 ABC->CA0
100 ABC->CAA
98 ABC->CAB
97 ABC->CAC
80 ABC->CB0
84 ABC->CBA
82 ABC->CBB
81 ABC->CBC
72 ABC->CC0
76 ABC->CCA
74 ABC->CCB
73 ABC->CCC

Electric_Medium_Voltage_Pole_Depth

Medium Voltage in ground depth
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 6

Electric_Medium_Voltage_Pole_Height

Medium Voltage Pole height
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
35 35 Feet
40 40 Feet
45 45 Feet
50 50 Feet
55 55 Feet
60 60 Feet
65 65 Feet
70 70 Feet
75 75 Feet
80 80 Feet
85 85 Feet
90 90 Feet
95 95 Feet

Electric_Medium_Voltage_Pole_Height_metric

Medium Voltage Pole Height in Metric
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
60 6 Meter
65 6.5 Meter
70 7 Meter
75 7.5 Meter
80 8 Meter
85 8.5 Meter
90 9 Meter
95 9.5 Meter
100 10 Meter
105 10.5 Meter
110 11 Meter
115 11.5 Meter
120 12 Meter
125 12.5 Meter
130 13 Meter
135 13.5 Meter
140 14 Meter
145 14.5 Meter
150 15 Meter
160 16 Meter
170 17 Meter
180 18 Meter
190 19 Meter
200 20 Meter
220 22 Meter
240 24 Meter
260 26 Meter
280 28 Meter
300 30 Meter

Electric_Medium_Voltage_Recloser_Continuous_Amps

Medium Voltage Recloser Continuous Amps Ratings
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
100 100 A
200 200 A
280 280 A
400 400 A
560 560 A
600 600 A
630 630 A

Electric_Medium_Voltage_Recloser_Interrupting_Amps

Medium Voltage Recloser Interrupting Amps
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
2000 2 kA
2500 2.5 kA
3000 3 kA
4000 4 kA
6000 6 kA
8000 8 kA
10000 10 kA

Electric_Medium_Voltage_Regulator_VA

Medium Voltage Regulator VA
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
25000 25 kVA
38000 38 kVA
38100 38.1 kVA
50000 50 kVA
57000 57 kVA
57200 57.2 kVA
69000 69 kVA
72000 72 kVA
75000 75 kVA
76000 76 kVA
76200 76.2 kVA
100000 100 kVA
114000 114 kVA
114300 114.3 kVA
124800 124.8 kVA
138000 138 kVA
144000 144 kVA
150000 150 kVA
152000 152 kVA
167000 167 kVA
171600 171.6 kVA
172500 172.5 kVA
200000 200 kVA
207000 207 kVA
216000 216 kVA
219000 219 kVA
228600 228.6 kVA
250000 250 kVA
276000 276 kVA
288000 288 kVA
300000 300 kVA
332000 332 kVA
333000 333 kVA
342900 342.9 kVA
345000 345 kVA
400000 400 kVA
414000 414 kVA
416000 416 kVA
432000 432 kVA
456000 456 kVA
500000 500 kVA
517500 517.5 kVA
518000 518 kVA
552000 552 kVA
576000 576 kVA
600000 600 kVA
621000 621 kVA
657000 657 kVA
667000 667 kVA
690000 690 kVA
700000 700 kVA
720000 720 kVA
750000 750 kVA
828000 828 kVA
833000 833 kVA
863000 863 kVA
864000 864 kVA
996000 996 kVA
999000 999 kVA
1000000 1000 kVA
1035000 1035 kVA
1145000 1145 kVA
1200000 1200 kVA
1242000 1242 kVA
1248000 1248 kVA
1296000 1296 kVA
1500000 1500 kVA
1554000 1554 kVA
1656000 1656 kVA
1728000 1728 kVA
2000000 2000 kVA
2001000 2001 kVA
2070000 2070 kVA
2100000 2100 kVA
2160000 2160 kVA
2499000 2499 kVA
2500000 2500 kVA
2589000 2589 kVA
3000000 3000 kVA
3462000 3462 kVA

Electric_Medium_Voltage_Switch_Continuous_Amps

Medium Voltage Switch Continuous Amps
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
600 600 A
900 900 A
1200 1200 A

Electric_Medium_Voltage_Switch_Interrupting_Amps

Medium Voltage Switch Interrupting Amps
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
16000 16 kA
25000 25 kA
29000 29 kA
31500 31.5 kA
40000 40 kA
50000 50 kA
63000 63 kA

Electric_Medium_Voltage_Transformer_VA

List of volt amps for devices, displayed in kilovolt
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
500 0.5 kVA
1000 1.0 kVA
1500 1.5 kVA
3000 3 kVA
5000 5 kVA
7000 7 kVA
7500 7.5 kVA
10000 10 kVA
15000 15 kVA
20000 20 kVA
25000 25 kVA
30000 30 kVA
37500 37.5 kVA
45000 45 kVA
50000 50 kVA
75000 75 kVA
100000 100 kVA
112500 112.5 kVA
150000 150 kVA
167000 167 kVA
200000 200 kVA
225000 225 kVA
250000 250 kVA
300000 300 kVA
333000 333 kVA
342000 342 kVA
375000 375 kVA
416000 416 kVA
450000 450 kVA
500000 500 kVA
666000 666 kVA
750000 750 kVA
833000 833 kVA
966000 966 kVA
1000000 1000 kVA
1250000 1250 kVA
1500000 1500 kVA
1750000 1750 kVA
2000000 2000 kVA
2500000 2500 kVA
3000000 3000 kVA
3500000 3500 kVA
3750000 3750 kVA
5000000 5000 kVA
7000000 7000 kVA
7500000 7500 kVA
10000000 10000 kVA
12000000 12000 kVA
4000000 4000 kVA
4250000 4250 kVA
4500000 4500 kVA
4750000 4750 kVA

Electric_Medium_Voltage_VAR

List of reactive volt amps for devices, displayed in kilovolts
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
15000 15 kvar
25000 25 kvar
33000 33 kvar
50000 50 kvar
100000 100 kvar
150000 150 kvar
200000 200 kvar
400000 400 kvar
450000 450 kvar
600000 600 kvar
900000 900 kvar
1200000 1200 kvar

Electric_Motor_Assistance_Type

Motor Starting Assistance Types
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Auto Transformer
2 Capacitor
3 Inductor
4 Inductor & Resistor
5 Resistor
6 Star-Delta

Electric_Motor_Type

Motor Type
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Induction
2 Synchronous

Electric_Neutral_Material

List of valid neutral materials for the distribution system
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
506 Steel
515 Aluminum
516 All Aluminum Conductor
517 All Aluminum Steel Reinforced
525 Copper
526 Hard Drawn Copper
527 Soft Drawn Copper
528 Stranded Copper
529 Copper Weld

Electric_Ohms_per_KM

Range domain of valid values for Electric Cable resistance per KM
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 999999

Electric_Operating_Status

Switchable Device Position
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Closed
1 Open
2 Open, Traceable

Electric_PF_Control_Type

Power Factor Control Type
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Current
2 Manual
3 Power Factor
4 VAR
5 Tempature
6 Time
7 Reactive Current

Electric_Phase_Angle_Offset_Range

Phase Offset values 0 - 60
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Min Max
0 180

Electric_Phase_Attribution_All

All Valid Phase Descriptions
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 De-Energized
1 III or C or c
2 II or B, or b
3 III,II or BC or bc
4 I or A,or a
5 I,III or AC or ac
6 I,II or AB or ab
7 I,II,III or ABC or abc

Electric_Phase_Not_Applicable

Domain for Phase attributes on Neutral and Ground
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 N/A
8 N/A, Traceable

Electric_Phase_Shift

Valid Phase Shift angles
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Min Max
-30 30

Electric_Phase_Whole_Degrees

Positive and Negative degrees in whole units
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Min Max
-180 180

Electric_Phase_Whole_Degrees_Positive

Degrees in whole units
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Min Max
0 180

Electric_Pole_Top_Configuration

Pole Top Configuratoin
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Alley Arm
2 Horizonal
3 Vertical
4 Trident
5 Inverted Trident
6 Iverted Alley Arm
7 Staggered

Electric_Power_Factor_Correcting_Type

Type of Power Factor Correcting Equipment
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Shunt
2 Series

Electric_Power_Factor_Range

Power Factor valid value range
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 1

Electric_Regulator_Maximum_Buck_Boost

Minimum and Maximum Regulator Buck percent
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 20

Electric_Regulator_Operation_Type

Regulator Operation Type
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Fixed Tap
2 Regulator Terminal
3 R-X settings
4 Load center

Electric_Remoted_Controlled

List of remote control types
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
2 No
4 All Phases
5 Individual Phase

Electric_RTU_Data_Type

RTU Data collector data format
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Analog
2 Digital

Electric_Short_Percent_Range

Range domain for setting a percentage in whole numbers
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Min Max
0 100

Electric_StaticWire_Material

List of static wire types
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1001 ACSR

Electric_Structure_Boundary_Switchgear_Material

List of valid Electric Switchgear Material
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Stainless Steel
4 Fiberglass
6 Steel
10 Plastic
15 Nickel
16 Brushed Nickel
17 Brushed Stainless Steel
18 Coated Steel
20 Other

Electric_Structure_Junction_High_Voltage_Pole_Material

List of valid Electric High Voltage Pole Material
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
2 Carbon Fiber
3 Composite
4 Fiberglass
5 Monofilament
6 Steel
7 Wood
20 Other

Electric_Structure_Junction_Low_Voltage_Pole_Material

List of valid Electric Low Voltage Pole Material
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
2 Carbon Fiber
3 Composite
4 Fiberglass
5 Monofilament
6 Steel
7 Wood
20 Other

Electric_Structure_Junction_Medium_Voltage_Pole_Material

List of valid Electric Medium Voltage Pole Material
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
2 Carbon Fiber
3 Composite
6 Steel
7 Wood
9 Precast Concrete
20 Other

Electric_Structure_Junction_Pad_Material

List of valid Electric Pad Material
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
4 Fiberglass
20 Other

Electric_Structure_Junction_Pad_Size

List of valid pad sizes
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown

Electric_Structure_Junction_Platform_Material

List of valid Electric Platform Material
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
4 Fiberglass
6 Steel
7 Wood
20 Other

Electric_Structure_Junction_Platform_Size

List of valid platform sizes
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown

Electric_Structure_Pole_Class_High_Voltage

List of valid pole classes
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Class 1
2 Class 2
101 Class H1
102 Class H2
103 Class H3
104 Class H4
105 Class H5
3 Class 3
4 Class 4

Electric_Structure_Pole_Class_Low_Voltage

List of valid pole classes
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
6 Class 6
7 Class 7
8 Class 8
9 Class 9
10 Class 10
1 Class 1
2 Class 2
3 Class 3
4 Class 4
5 Class 5
101 Class H1
102 Class H2
103 Class H3
104 Class H4
105 Class H5
106 Class H6

Electric_Structure_Pole_Class_Medium_Voltage

List of valid pole classes
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Class 1
2 Class 2
3 Class 3
4 Class 4
5 Class 5
6 Class 6
7 Class 7
8 Class 8
9 Class 9
10 Class 10
101 Class H1
102 Class H2
103 Class H3
104 Class H4
105 Class H5
106 Class H6

Electric_Supported_Equipment_Type_All

Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
2 Step Transformers and Regulators
4 Capacitors
6 Step Transformers, Regulators and Capacitors
1 Switchable Devices
3 Switchable devices, Step Transformers and Regulators
5 Switchable Devices and Capacitors
7 Switchable Devices, Step Transformers, Regulators and Capacitors
8 Distribution Transformers
9 Distribution Transformers and Switchable Devices\
10 Distribution Transformers, Step Transformers and Regulators
11 Distribution Transformers, Step Transformers, Regulators and Switchable Devices
12 Distribution Transformers and Capacitors
13 Distribution Transformers, Capacitors and Switchable Devices
14 Distribution Transformers, Capacitors, Step Transformers and Regulators
15 Distribution Transformers, Capacitors, Step Transformers, Regulators and Switchable Devices

Electric_Switch_Breaking_Medium

Switch Arc Breaking Medium
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Air
2 CO2
3 Gas
4 Hybrid
5 Oil
6 Vaccum

Electric_System_Frequency

Valid Frequencies for Phase
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
50 50 Hz
60 60 Hz

Electric_Taps_Range

Valid Taps Range
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Min Max
0 32

Electric_Tap_Change_Percent

Valid Tap Change Percent Rage
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Min Max
-15 15

Electric_Tap_Maximum_Change

Valid Tap Maxium Change Range
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 20

Electric_Temperature_C

Temperature in Celsius
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 0 C
75 75 C
90 90 C
150 150 C
190 190 C
210 210 C
230 230 C

Electric_Temperature_F

Temperature in Fahrenheit
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 32 F
75 167 F
90 194 F
150 302 F
180 356 F
210 410 F
230 446 F

Electric_Transformer_Cooling

Transformer cooling type
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Air Natural (AN)
2 Air Blast
3 Oil Natural/Air Natural (ONAN)
4 Oil Natural/Air Forced (ONAF)
5 Oil Forced/Air Forced (OFAF)
6 Oil Forced/Water Forced (OFWF)

Electric_Transformer_Phase_Shift

Transformer phase shift
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
-180 180 lead
-150 150 lead
-120 120 lead
-60 60 lead
-30 30 lead
0 Unknown
30 30 lag
60 60 lag
120 120 lag
150 150 lag
180 180 lag

Electric_Trip_Count

Number of times a recloser or breaker will trip before locking out
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Min Max
0 5

Electric_Trip_Delay_Range

Trip Delay time
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Min Max
0 10

Electric_Trip_Type

Valid types of tripping
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
10 Trip Only
11 Trip and Lockout

Electric_Voltage_Bandwidth

Voltage Bandwidth Percentage
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Min Max
-5000 5000

Electric_Voltage_Offset

Voltage Offset Range
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Min Max
0 1000

Electric_Winding_Ratio_Long

Transformer and Regulator winding ratios
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
50 50:5
60 60:5
75 75:5
80 80:5
100 100:5
125 125:5
150 150:5
200 200:5
250 250:5
300 300:5
400 400:5
500 500:5
600 600:5
800 800:5
1000 1000:5
1200 1200:5
1500 1500:5
1600 1600:5
2000 2000:5
3000 3000:5
4000 4000:5
6000 6000:5
8000 8000:5
5 5:5
10 10:5
15 15:5
20 20:5
25 25:5

Electric_Winding_Vector_Group

IEC Defined winding vector groups
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Dd0
2 Dd10
3 Dd2
4 Dd4
5 Dd6
6 Dd8
7 Dy1
8 Dy11
9 Dy5
10 Dy7
11 Dz0
12 Dz10
13 Dz2
14 Dz4
15 Dz6
16 Dz8
17 Yd1
18 Yd11
19 Yd5
20 Yd7
21 Yy0
22 Yy6
23 Yy7
24 Yz1
25 Yz11
26 Yz5
27 Yz7

Electric_Wire_Ampacity

Wire Ampacity Values
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
40 6000

Electric_Wire_Diameter_in

Wire diameter AWG size, stored as inches
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
0.0641 14
0.072 13
0.0808 12
0.0907 11
0.1019 10
0.1144 9
0.1285 8
0.1443 7
0.162 6
0.1819 5
0.2043 4
0.2294 3
0.2576 2
0.2893 1
0.3249 0
0.3648 00
0.4096 000
0.46 0000
0.666 366
0.792 477
0.811 500

Electric_Wire_Diameter_metric

Electric Wire Diameter in Metric
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 1.5 mm2
2 2.5 mm2
4 4 mm2
6 6 mm2
10 10 mm2
15 15 mm2
16 16 mm2
18 18 mm2
20 20 mm2
25 25 mm2
29 29 mm2
30 30 mm2
35 35 mm2
41 41 mm2
46 46 mm2
50 50 mm2
70 70 mm2
72 72 mm2
95 95 mm2
99 99 mm2
120 120 mm2
150 150 mm2
185 185 mm2
240 240 mm2
253 253 mm2
279.8 279.8 mm2
300 300 mm2
329 329 mm2
354 354 mm2
380 380 mm2
400 400 mm2
405 405 mm2
430 430 mm2
456 456 mm2
481 481 mm2
500 500 mm2
506 506 mm2
630 630 mm2
800 800 mm2
1000 1000 mm2
1200 1200 mm2
1600 1600 mm2
2000 2000 mm2

Electric_Wire_Diameter_mm

Wire diameter AWG size, stored as mm
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
11.684 0000
10.40384 000
9.26592 00
8.25246 0
7.34822 1
6.54304 2
5.82676 3
5.18922 4

Electric_Wire_FullDiameter

Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 5

Electric_Wire_FullDiameter_metric

Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 100

Electric_Wire_Insulation_Material

Electric Wire Insulation Material Codes
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 CPE
2 CSPE
3 ECTFE Halar
4 EPDM
5 EPR
6 EPRR
7 ETFE
8 FEP
9 Fiberglass
10 HEPR
11 NYLON
12 PE
13 PFA
14 Plenum PVC
15 Polychloroprene
16 PP
17 PTFE
18 PUR
19 PVC
20 PVDF
21 Rubber
22 SBR
23 Silicone
24 SR-PVC
25 TPE
26 TPR
27 XLPE

Electric_Wire_Insulation_Maximum_Voltage

The maximum voltage, in kV, that the insulation will support
Domain Details
Type Split Policy Merge Policy
LONG DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1000 1 kV
2000 2 kV
4000 4 kV
5000 5 kV
8000 8 kV
15000 15 kV
25000 25 kV
35000 35 kV
72500 72.5 kV
145000 145 kV
245000 245 kV
362000 362 kV
420000 420 kV
550000 550 kV

Electric_Wire_Insulation_Thickness

Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 2

Electric_Wire_Insulation_Thickness_metric

Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 100

Electric_Wire_Insulation_Type

Electric Wire Insulation Type
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Bare Wire
2 Cross linked polyethylene
3 Ethylene propylene rubber
4 Paper insulated lead covered
5 Polyethylene
6 PVC
7 Tree retardant cross linked polyethylene

Electric_Wire_kcmil

Wire kcmil sizes
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
250 4000

Electric_Wire_Manufacturer

Manufacturer of wire
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Alcan
2 Alcoa
3 Canada Wire
4 General Cable
5 Kerite
6 Okonite
7 Pirelli
8 Republic Wire
9 Rome
10 Siecor Corporation
11 Southwire Co
9999 Other

Electric_Wire_Metal_Material

The base metal material type of the wire
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
6 Steel
15 Aluminum
25 Copper

Electric_Wire_Rated_Strength

Strength of wire
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
100 50000

Electric_Wire_Rated_Strength_Metric

Strength of wire (kg)
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
50 2000

Electric_Wire_Sheath_Thickness

Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 1000

Electric_Wire_Sheath_Thickness_metric

Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 1000

Electric_Wire_Type

Wire description
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 AAAC
2 AAC
3 AAC/TW
4 ACAR
5 ACCR
6 ACSR
7 ACSR/AW
8 ACSR/TW
9 ACSS
10 ACSS/AW
11 ACSS/TW
12 AL
13 AL EPR
14 ALQPX
15 ALX
16 AX
17 AXLC
18 AXN
19 AXNJ
20 BCU
21 CS
22 CU
23 CU EPR
24 CU PILC
25 CU TPX
26 CUF
27 CUWD
28 CW
29 CWC
30 CXN
31 CXNJ
32 Duplex
33 EPR-PEJ
34 EPR-PEJ CU
35 HDCU
41 HSS
42 PECN AL
43 PECN CU
44 PELPE CU
45 PID AL
46 PID CU
47 PID-PEJ AL
48 PID-PEJ CU
49 PILC CU
50 PILC NJ CU
51 PILC-NJ
52 PILC-PEJ
53 PILC-PEJ CU
54 Quadruplex
55 RHH
56 RHW-2
57 Single
58 SSAC
59 STCU
60 STEL
61 THWW
62 Triplex
63 TRXLPECN-PEJ AL PID
64 TRXLPECN-PEJ CU
65 TRXLPECN-PEJ CU PID
66 UDA
67 UQA
68 USE-2
69 UTA
70 WP
71 WPAL
72 WPCU
73 XLPE AL
74 XLPE CU
75 XLPECN-PEJ
76 XLPECN-PEJ AL
77 XLPE-PEJ AL

Electric_Wire_Weight

Wire Weight
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
20 2000

Electric_Wire_Weight_Metric

Wire Weight (kg)
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
10 1000

Electric_XFR_Type

Transformer Type
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Dry
2 Oil Filled
3 Pumped Oil
4 Air Cooled

HorizontalAlignment

Valid horizontal symbol alignment values.
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Left
1 Center
2 Right
3 Full

Joint_Use_Cable_Owner

List of owners of Cable equipment
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown

Joint_Use_Fiber_Owner

List of owners of Fiber equipment
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown

Joint_Use_Telecom_Owner

List of owners of Telecom equipment
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown

Lifecycle_Status

Valid lifecycle states for the assets.
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Out of Service
1 Proposed
2 In Service
4 Planned Removal

Lifecycle_Status_Combined

Bitwise combination of lifecycle states for subnetwork management
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Out of Service
1 Proposed
2 In Service
3 Proposed and In Service
4 Planned Removal
6 In Service and Planned Removal
7 Maintenance

Spatial_Confidence

Confidence in the accuracy of the spatial data
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 High
2 Medium
3 Low

Spatial_Source

Source of the spatial location
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 As-Built
2 CAD
3 Digitized
4 GPS/GNSS
5 Field Sketch

Structure_Building_Type

Building Types
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Dispatch Center
2 Control Center
3 Service Center

Structure_Duct_Position_Horizontal

Horizontal Duct Position
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Min Max
1 10

Structure_Duct_Position_Vertical

Vertical Duct Position
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Min Max
1 10

Structure_Junction_Communications_Pole_Height

Communications pole heights
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
20 20 Feet
25 25 Feet
30 30 Feet
35 35 Feet
40 40 Feet
45 45 Feet
50 50 Feet
55 55 Feet
60 60 Feet
65 65 Feet
70 70 Feet
75 75 Feet
80 80 Feet
85 85 Feet
90 90 Feet
95 95 Feet

Structure_Junction_Communications_Pole_Height_metric

Comms Height of Pole in Metric
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
60 6 Meter
65 6.5 Meter
70 7 Meter
75 7.5 Meter
80 8 Meter
85 8.5 Meter
90 9 Meter
95 9.5 Meter
100 10 Meter
105 10.5 Meter
110 11 Meter
115 11.5 Meter
120 12 Meter
125 12.5 Meter
130 13 Meter
135 13.5 Meter
140 14 Meter
145 14.5 Meter
150 15 Meter
160 16 Meter
170 17 Meter
180 18 Meter
190 19 Meter
200 20 Meter
220 22 Meter
240 24 Meter
260 26 Meter
280 28 Meter
300 30 Meter

Structure_Pole_Depth

Depth of pole in ground
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 20

Structure_Wall_Count

Number of walls in a vault
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Min Max
3 15

Structure_Wall_Position

The position of the wall in the vault
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 North
2 Northeast
3 East
4 Southeast
5 South
6 Southwest
7 West
8 Northwest

Symbol_Rotation

Valid range of degrees for rotation
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Min Max
0 359

UtilityNetwork_5_AssociationStatus

Indicates how the feature participates in associations.
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 None
1 Container
2 Structure
4 Content
5 Content and Container
6 Content and Structure
8 Attachment
9 Attachment and Container
10 Attachment and Structure
12 Attachment and Content
13 Attachment and Content and Container
14 Attachment and Content and Structure
16 Visible Content
17 Visible Content and Container
18 Visible Content and Structure
24 Visible Content and Attachment
25 Visible Content and Attachment and Container
26 Visible Content and Attachment and Structure
32 Connectivity
33 Connectivity and Container
34 Connectivity and Structure
36 Connectivity and Content
37 Connectivity and Content and Container
38 Connectivity and Content and Structure
40 Connectivity and Attachment
41 Connectivity and Attachment and Container
42 Connectivity and Attachment and Structure
44 Connectivity and Attachment and Content
45 Connectivity and Attachment and Content and Container
46 Connectivity and Attachment and Content and Structure
48 Connectivity and Visible Content
49 Connectivity and Visible Content and Container
50 Connectivity and Visible Content and Structure
56 Connectivity and Visible Content and Attachment
57 Connectivity and Visible Content and Attachment and Container
58 Connectivity and Visible Content and Attachment and Structure

UtilityNetwork_5_FeatureSourceID

The source feature class name in the utility network.
Domain Details
Type Split Policy Merge Policy
SHORT DEFAULT DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Association
2 System Junction
3 System Junction Object
4 Structure Junction
5 Structure Line
6 Structure Boundary
7 Structure Junction Object
8 Structure Edge Object
9 Electric Device
10 Electric Line
11 Electric Assembly
12 Electric Junction
13 Electric Subnet Line
14 Electric Junction Object
15 Electric Edge Object

UtilityNetwork_5_IsConnected

Indicates if the feature is connected to a subnetwork controller.
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 False
1 True
2 Unknown

UtilityNetwork_5_IsContentVisible

Indicates if the content or attachment association is visible for containment associations.
Domain Details
Type Split Policy Merge Policy
SHORT DEFAULT DEFAULT
Domain Values
Code Value Alternate Name Description
0 False
1 True

UtilityNetwork_5_IsDeleted

Indicates if a subnetwork has been marked for deletion.
Domain Details
Type Split Policy Merge Policy
SHORT DEFAULT DEFAULT
Domain Values
Code Value Alternate Name Description
0 False
1 True

UtilityNetwork_5_IsDirty

Indicates if a subnetwork is dirty.
Domain Details
Type Split Policy Merge Policy
SHORT DEFAULT DEFAULT
Domain Values
Code Value Alternate Name Description
0 False
1 True
2 Invalid

UtilityNetwork_5_IsSubnetworkController

Indicates if a device feature is a subnetwork controller.
Domain Details
Type Split Policy Merge Policy
SHORT DEFAULT DEFAULT
Domain Values
Code Value Alternate Name Description
0 False
1 True

UtilityNetwork_5_TerminalNames

The terminal names in the utility network.
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 None
1 Single Terminal
2 DT:Source
3 DT:Load
4 T:Terminal A
5 T:Terminal B
6 T:Terminal C
7 2wXFR:Primary
8 2wXFR:Secondary
9 V:Terminal A
10 V:Terminal B
11 V:Terminal C
12 INV:DC Input
13 INV:AC Output
14 RT:AC Input
15 RT:DC Output
16 CB:Line Side
17 CB:Bus Side
18 Bypass:Regulator Source
19 Bypass:Regulator Load
20 Bypass:Regulator In Bushing
21 Bypass:Regulator Out Bushing
22 VR:In Bushing
23 VR:Out Bushing
24 HVDS:Bus Side
25 HVDS:Line Side
26 HVIS:Terminal A
27 HVIS:Terminal B
28 RT:Measured Power
29 RT:Communications
30 RT:Aux Power
31 SS:S1
32 SS:S2
33 Power
34 Monitor
35 Communications
36 3wXFR:Primary
37 3wXFR:Secondary
38 3wXFR:Tertiary
39 Line Side
40 Load Side
41 CBD:Line Side
42 CBD:Bus Side
43 2wXFRBD:Primary
44 2wXFRBD:Secondary
45 GS:Line Side
46 GS:Ground Side
47 TW:Core
48 TW:Bushing

UtilityNetwork_5_TierName

The tier names in the utility network.
Domain Details
Type Split Policy Merge Policy
SHORT DEFAULT DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Electric Generation
2 Electric Transmission
3 Electric Subtransmission
4 Electric Distribution Primary
5 Electric Distribution
6 Electric Secondary

UtilityNetwork_5_TierTopologyType

The type of topology for each tier.
Domain Details
Type Split Policy Merge Policy
SHORT DEFAULT DEFAULT
Domain Values
Code Value Alternate Name Description
1 Radial
2 Mesh

UtilityNetwork_5_UnknownAssetType

The AssetType domain for the Unknown AssetGroup.
Domain Details
Type Split Policy Merge Policy
SHORT DEFAULT DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown

VerticalAlignment

Valid symbol vertical alignment values.
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Top
1 Center
2 Baseline
3 Bottom

Wire_Aerial_Support_Height

Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown

Wire_Aerial_Support_Height_Metric

Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown

Wire_Aerial_Support_Length

Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
1 100

Wire_Aerial_Support_Length_Metric

Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0.25 100

Wire_Aerial_Support_Material

Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Aluminium
2 Composite
3 Lamenated Wood
4 Fiberglass
5 Monofiliment
6 Steel
7 Wood
20 Other

Wire_Anchor_Guy_Depth

Minimum and maximum anchor guy depth
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 20

Wire_Crossarm_Brace_Count

Number of Braces
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Min Max
0 12

Wire_Crossarm_Count

Number of Crossarms
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Min Max
1 4

Wire_Crossarm_Face_Height

Width of crossarm face
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unkonwn
6 6"
3.5 3 1/2"
3.625 3 5/8"
3.75 3 3/4"
4 4"
4.25 4 1/4"
4.625 4 5/8"
5.25 5 1/4"

Wire_Crossarm_Face_Height_Metric

Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
100 100 mm
125 125 mm
150 150 mm
175 175 mm

Wire_Crossarm_Length

Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
4 4'
6 6'
8 8'
10 10'
12 12'

Wire_Crossarm_Length_Metric

Crossarm Length in Meters
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 0

Wire_Crossarm_Material

Crossarm material
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
4 Fiberglass
6 Steel
7 Wood
20 Other

Wire_Crossarm_MountHeight

Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
15 120

Wire_Crossarm_Mount_Height_Metric

Crossarm Mounting Height Metric
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 0

Wire_Crossarm_Thickness

Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
3.5 3 1/2"
3.625 3 5/8"
3.75 3 3/4"
4 4"
4.25 4 1/4"
4.625 4 5/8"

Wire_Crossarm_Thickness_Metric

Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
100 100 mm
125 125 mm
150 150 mm
175 175 mm
200 200 mm

Wire_Crossarm_Usage_Type

Crossarm usage
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Other
2 Tangent
3 Dead End
4 Double Dead End
5 Device Braced
6 Riser Terminus

Wire_Duct_Bank_Width

Width of the duct bank
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 50

Wire_Duct_Diameter

Diameter of duct
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
0.91 3/4"
1.175 1"
1.52 1 1/4"
1.76 1 1/2"
2.235 2"
2.735 2 1/2"
3.36 3"
3.86 3 1/2"
4.32 4"
5.38 5"
6.435 6"

Wire_Duct_Diameter_mm

Diameter of the duct in millimeters
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
20 20 mm
25 25 mm
32 32 mm
38 38 mm
40 40 mm
50 50 mm
63 63 mm
75 75 mm
90 90 mm
94 94 mm
100 100 mm
105 105 mm
117 117 mm
125 125 mm
137 137 mm
150 150 mm
160 160 mm
225 225 mm

Wire_Number_of_Ducts

Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Min Max
0 64

Wire_Pedestal_Depth

Minimum and maximum pedestal depth
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 5

Wire_Pole_Height_Combined

List of valid heights for all poles
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
25 25 Feet
30 30 Feet
35 35 Feet
40 40 Feet
45 45 Feet
50 50 Feet
55 55 Feet
60 60 Feet
65 65 Feet
70 70 Feet
75 75 Feet
80 80 Feet
85 85 Feet
90 90 Feet
95 95 Feet
100 100 Feet
105 105 Feet
110 110 Feet
115 115 Feet
120 120 Feet
125 125 Feet

Wire_Structure_Cabinet_Design_Type

List of cabinet designs
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
51 Indoor
52 Water Proof
53 Water Tight

Wire_Structure_Guy_Diameter_in

List of diameters of guys in inches
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
6.35 1/4"
7.9629 5/16"
9.525 3/8"
11.1125 7/16"
12.7 1/2"
14.2875 9/16"
25.4 1"

Wire_Structure_Junction_Anchor_Guy_Size

List of anchor guy sizes
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
8 8"
10 10"
12 12"
14 14"

Wire_Structure_Junction_Anchor_Guy_Type

List of anchor guy types
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
41 Single Helix
42 Double Helix
43 Triple Helix
44 Manta Ray
45 Square
46 Disk
47 Rock

Wire_Structure_Junction_Cabinet_Material

List of valid cabinet materials
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Stainless Steel
4 Fiberglass
6 Steel
10 Plastic
15 Nickel
16 Brushed Nickel
17 Brushed Stainless Steel
18 Coated Steel
20 Other

Wire_Structure_Junction_Cabinet_Size

List of cabinet sizes
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown

Wire_Structure_Junction_Combined_Material

Combined list of structure materials
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Stainless Steel
3 Composite
4 Fiberglass
6 Steel
7 Wood
8 Poured Concrete
9 Precast Concrete
10 Plastic
11 Cast Iron
20 Other

Wire_Structure_Junction_Comm_Pole_Material

Communications Pole Material
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
3 Composite
4 Fiberglass
6 Steel
7 Wood
9 Precast Concrete
20 Other

Wire_Structure_Junction_Foundation

Type of foundation
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Other
2 Set Extra Deep In Earth
3 Set Normal With Concrete Backfill
4 Set Normally In Earth
5 Set On Concrete Foundation

Wire_Structure_Junction_Guy_Material

List of valid guy materials
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
6 Steel

Wire_Structure_Junction_Handhole_Material

List of valid electric handhole materials
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Stainless Steel
4 Fiberglass
6 Steel
20 Other

Wire_Structure_Junction_Handhole_Size

List of handhole sizes
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown

Wire_Structure_Junction_Junction_Box_Material

List of valid junction box materials
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Stainless Steel
4 Fiberglass
6 Steel
9 Precast Concrete
20 Other

Wire_Structure_Junction_Junction_Box_Size

List of valid junction box sizes
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown

Wire_Structure_Junction_Maker_Material

List of types of marker materials
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Stainless Steel
3 Composite
4 Fiberglass
6 Steel
7 Wood
8 Poured Concrete
9 Precast Concrete
10 Plastic

Wire_Structure_Junction_Manhole_Size

List of valid manhole sizes
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
24 24"
28 28"
32 32"
36 36"
48 48"
50 50"

Wire_Structure_Junction_Manhole_Type

List of types of manholes
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
61 Deep
62 Normal
63 Shallow

Wire_Structure_Junction_Pedestal_Material

List of valid pedestal materials
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
6 Steel
7 Wood
20 Other

Wire_Structure_Junction_Pole_Class_Combined

Combined list of pole classes
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Class 1
2 Class 2
3 Class 3
4 Class 4
5 Class 5
6 Class 6
7 Class 7
8 Class 8
9 Class 9
10 Class 10
101 Class H1
102 Class H2
103 Class H3
104 Class H4
105 Class H5

Wire_Structure_Junction_Pole_Treatment_Type

List of pole or tower treatment types
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Butt
2 Natural
3 Penta
4 Creosote
5 Chromated Copper Arsenates
6 Chemonite
7 Napthena
8 Cellon
9 Paint
10 Copper Naphthenate
11 Other

Wire_Structure_Junction_Support_Pole_Class

List of valid pole classes
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Class 1
2 Class 2
3 Class 3
4 Class 4
5 Class 5
6 Class 6
7 Class 7
8 Class 8
9 Class 9
10 Class 10
101 Class H1

Wire_Structure_Junction_Support_Pole_Height

Support Pole Heights
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
35 35 Feet
40 40 Feet
45 45 Feet
50 50 Feet
55 55 Feet
60 60 Feet
65 65 Feet
70 70 Feet
75 75 Feet
80 80 Feet
85 85 Feet
90 90 Feet
95 95 Feet

Wire_Structure_Junction_Support_Pole_Height_metric

Wire Support Height of Pole in Metric
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
60 6 Meter
65 6.5 Meter
70 7 Meter
75 7.5 Meter
80 8 Meter
85 8.5 Meter
90 9 Meter
95 9.5 Meter
100 10 Meter
105 10.5 Meter
110 11 Meter
115 11.5 Meter
120 12 Meter
125 12.5 Meter
130 13 Meter
135 13.5 Meter
140 14 Meter
145 14.5 Meter
150 15 Meter
160 16 Meter
170 17 Meter
180 18 Meter
190 19 Meter
200 20 Meter
220 22 Meter
240 24 Meter
260 26 Meter
280 28 Meter
300 30 Meter

Wire_Structure_Junction_Support_Pole_Material

List of support pole materials
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
4 Fiberglass
6 Steel
7 Wood
20 Other

Wire_Structure_Junction_Vault_Cover_Material

Manhole Cover Material
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
4 Fiberglass
6 Steel
8 Poured Concrete
9 Precast Concrete
11 Cast Iron
20 Other

Wire_Structure_Junction_Vault_Material

List of vault materials
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
6 Steel
7 Wood
8 Poured Concrete
9 Precast Concrete
20 Other

Wire_Structure_Junction_Vault_Size

List of vault sizes
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown

Wire_Structure_Line_Aerial_Support_Material

List of materials used for aerial supports
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
4 Fiberglass
6 Steel
20 Other

Wire_Structure_Line_Duct_Bank_Material

List of materials for duct banks
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
3 Composite
4 Fiberglass
8 Poured Concrete
9 Precast Concrete
10 Plastic
20 Other

Wire_Structure_Line_Duct_Material

List of duct materials
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
3 Composite
4 Fiberglass
8 Poured Concrete
9 Precast Concrete
10 Plastic
20 Other

Wire_Structure_Line_Trench_Material

List of valid trench materials
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
11 Open
12 Earth Covered
20 Other

Wire_Structure_Manufacturer

All Electric Structure Manufacturer
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Appalachee
2 Atlantic Wood Treatment
3 Baldwin
4 Baxco
5 Bell Co
6 Bell Timber
7 Brown
8 Cahaba
9 Carsonite
10 CDR
11 Chance Foundations
12 Crown Zellerbach
13 CTC
14 ECB Abbert Inc
15 ECP Utility
16 Escambia
17 Fiber Tech
18 Flight Light
19 Georgia Pacific
20 Gulf Creosote
21 Gulf States
22 Hot Box
23 Howard Industries
24 Huxford
25 International Paper
26 Jensen Precast
27 Josyln
28 Koppers
29 Lakeshore Electric
30 MacLean
31 Midwestern Electric
32 Milbank Electric
33 Miller
34 Osmose
35 P&R Tech
36 PenCell
37 Quazite
38 Republic
39 Schweitzer
40 Seaman Timber
41 Shea Concrete
42 Sherman Concrete
43 Stallworth
44 Swift
45 Thomas Net
46 Utility Concrete
47 Weyerhaeuser
48 William Frick & Company
9999 Other

Wire_Support_Pole_Depth

Support pole buried depth
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 30

Wire_Trench_Width

Depth of trench
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 30

Wire_Vault_Depth

Dept of vault
Domain Details
Type Split Policy Merge Policy
DOUBLE DUPLICATE DEFAULT
Domain Values
Min Max
0 100

Yes_No

Valid Yes, No values
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 Unknown
1 Yes
2 No

Yes_No_Simple

Valid Yes, No values without unknown
Domain Details
Type Split Policy Merge Policy
SHORT DUPLICATE DEFAULT
Domain Values
Code Value Alternate Name Description
0 No
1 Yes